OTP-MZ Myriad Ductless MultizoneHeat Pump
Operating mode •Coolingandheating.
Nominal capacity •24000BTU/hroutdoorunitconnectedtotwo12000BTU/hrindoorunits.
Voltage •240/208V,60Hz,1-phase.
Indoor unit •Highwallinstallation,dualsideconnection.•Plastichousing,standardwhite. •4-speedcross-flowfan(turbo,high,mediumandlow). •Smartpreheating.•Washablefilters.
Outdoor unit •Variablespeedrotarycompressor(INVERTER),withoverloadprotection. •Electronicexpansionvalveforprecisecontrolofrefrigerantflow. •Condenserfinscoveredinabluehydrophiliccoatingforimprovedcorrosionresistance.
•Largediameterquietaxial-flowfanformoreefficientheatexchange. •Coolingmodeoperatingambienttemperature:-5to48°C(23to118.4°F).
•Heatingmodeoperatingambienttemperature:-15to27°C(5to80.6°F).
• Installationonepoxy/polyesterpowdercoatedadjustablesteelwallbracket(optional).
Refrigerant •R410Arefrigerant,pre-chargedfor98ft.(30m)totallengthofconnectionpiping.
Connection piping •Minimumpipinglengthof10ft.(3m). •Flaredconnections.
Control •Twowirelessremotesincluded. •Settemperature:16to30°C(61to86°F). •Modes:AUTO,COOL,DRY,FANandHEAT. •SLEEPmode. •Timer. •Auto-Cleanfunction(X-Fan). •Horizontaldeflectoradjustment.•Temperaturedisplayformat(°Cor°F). •Smartdefrosting,startsonlywhenrequired. •Autorestartincaseofpowershortage.
Warranty Note: All heat pump systems must be installed and registered by a certified Ouellet installer to be covered by the basic warranty. •5-yearbasicwarrantyonparts(labournotincluded). Soldseparately: •Extendedwarrantyfromthe1stto5thyear,partsandlabour. •Extendedwarrantyfromthe1stto10thyear,partsandlabourwithsystemreplacementifthecompressorfails.
Application •Diningroom-kitchen,livingroom,familyroom,commercialbuilding,officebuilding,condo,restaurant.
Features
Indoor Units
16 SEEROutdoor Unit
R410A
To Order:
OTP-B12000D-I OTP-B12000D-I OTP-MZ24000D-E IndoorUnit IndoorUnit OutdoorUnit
Note that each unit is individually wrapped.
OTP-B12000D-I OTP-B12000D-I
OTP-MZ24000D-E
+ + = OTP-MZ
OTP-MZ
Option
Models
Product # Description
OTP-WB3 Adjustablewallbracketforoutdoorunit
Product #12x OTP-B12000D-I
1x OTP-MZ24000D-E
Technical Performance
SEER - 15
HSPF - 8.2
Energy Star - No
Indoor Unit
Cooling capacity W (BTU/hr) 3517(12000)
Heating capacity W (BTU/hr) 3810(13000)
Dehumidication pt/hr (l/hr) 2.96(2.8)
Air flow volume T/H/M/L2 cfm 335/277/253/218
Sound level T/H/M/L2 dB (A) 44/39/36/33
Fan motor power output W 20
Fan motor RLA A 0.2
Deflector stepper motor power output W 2
Weight lb (kg) 22(10)
Outdoor Unit
Cooling capacityNominal W (BTU/hr) 7620(26000)
Min.–max. W (BTU/hr) 2198-9671(7500-33000)
Heating capacityNominal W (BTU/hr) 8499(29000)
Min.–max. W (BTU/hr) 2198-10257(7500-35000)
Used cooling power inputNominal W 3050
Min.–max. W 650–4500
Used heating power inputNominal W 2800
Min.–max. W 980–3950
Air flow volume H/M/L cfm 1942/1707/1413
Sound level dB (A) 58
Compressor power output W 2200
Compressor LRA A 45
Compressor RLA A 9.4
Fan motor power output W 60
Fan motor RLA A 0.59
Refrigerant volume (R410A) oz (g) 77.6(2200)
Weight lb (kg) 134(61)
Connection Piping
Pre-charge length ft. (m) 98(30)
Additional refrigerant charge oz/ft. (g/m) 0.2(18.6)
Liquid pipe outer diameter in. 1/4
Gas pipe outer diameter in. 3/8
Maximum height difference ft. (m) 33(10)
Maximum total length ft. (m) 230(70)
Drain pipe inner diameter in. 5/8
1 2 indoor units and 1 outdoor unit. Note that each unit is individually wrapped.2 Cross-Flow Fan Speeds: (T) Turbo / (H) High / (M) Medium / (L) Low.
OTP-MZ
Indoor UnitL H D A B C
in. mm in. mm in. mm in. mm in. mm in. mm
OTP-B12000D-I 331/4 846 103/4 274 7 178 51/8 130 211/4 541 63/4 173
Outdoor UnitL H D A B
in. mm in. mm in. mm in. mm in. mm
OTP-MZ24000D-E 371/4 945 275/8 701 155/8 396 22 559 141/2 368
Adjustable Wall Bracket
L H D Maximum Capacity
in. mm in. mm in. mm lb kg
OTP-WB3 297/8 759 153/4 400 241/4 616 500 227
Front View
Indoor Unit
Outdoor Unit
Side View Top View
A
B
L
H
D
Front View Back ViewSide View
L
A B C
D
H
Adjustable Wall Bracket for Outdoor Unit
L
H
D
Top Related