Sensor Mounting Location
Sensor Settings
OPTEX X-Zone T Quick Setup GuideFor detailed information, please refer to the installation manual supplied with each sensorand notes please refer to the X-Zone T Connection Matrix.
2”
1/4”
Header
Align with center of clear door openingUse supplied Mounting Template. Place template so that it is in the center of the clear door opening and so that the bottom of the tem-plate is between 1/4” and 2” from the bottom edge of the header.
Drill (2) 1/8” holes and (1) 5/16” hole as indi-cated on the template. Remove template from header. Remove the cover from the sensor. Fasten the sensor securely to the header using the supplied screws (do not over-torque screws or sensor body may distort).
Remove the cover and unfold the label.
Ensure sensors are properly set to factory defaults as shown and described below.
NOTE: If uni-directional motion detection is desired, move dipswitches 9 UP.
1. Dipswitch settings
Refer to instruction manual for details on all dipswitch settings.
2. AIR Area Width
Set shutters to Wide Position
3. AIR (Presence) and Microwave Angle Adjustments 4. Microwave Sensitivity 5. Walk TestAIR Angle Adjust
Set Red Ring at –2 degrees(Arrow at Approx. 10 o’ clock)
Set to 10 o’clock (two dots at top)
Microwave Angle AdjustSet center Philips adjuster to 38 degrees
(Blue Dots are at 2 o’ clock)
Power up sensors and wait 10 seconds to test presence area. Perform walk test procedure to verify substantial compliance with ANSI A156.10 section 8.
18730 Wilmington Ave, Unit 100Rancho Dominguez, CA 90220Ph 310 214-8644Fax 310 898-1098Toll free 800 877-6656www.ot-inc.com
OPTEX Technologies Inc.
8510 McAlpine Park Dr.Suite 108Charlotte, NC 28211
OPTEX Technical Support (800) 877-6656 East Coast: Perry Watkins, Ext. 220 Central U.S.: Jason Kirn, Ext. 201Support: Refugio Guadaljara, Ext. 202
WARNING: To comply with ANSI A156.10, if the reveal on the door (mounting surface of sensor to face of sliding panel) is great-er than 2½”, turn the AIR adjuster (Red Ring) CCW (Shallow) until the door recycles on the closing cycle. Then refer to step 2 under troubleshooting to properly adjust the AIR angle.
Troubleshooting
1. Operation LED turns solid Orange then door reopens (Microwave Motion Detecting Door)
2. Operation LED turns Flashing Red, then door reopens (Row 2 Presence Detecting Door)
a. Reduce sensitivity: turn sensitivity po-tentiometer CCW.
b. Adjust Microwave angle towards deep (Clockwise) slightly.
a. Move AIR angle adjustment (Red Ring) slightly Clockwise until ghosting stops.
NOTE: When changing the AIR angle, sensor may go into detection and hold door open. In this case, reset sensor by moving any dip-switch, then move it back.
Door reopens on closing cycle:
Wiri
ng D
iagr
am
Doo
r Con
trol
ler
Not
e: F
or O
EM
man
ufac
ture
r sp
ecifi
c co
nnec
tions
, ref
er to
the
X-Z
one
T C
onne
ctio
n M
atrix
.
24 V
DC
0 V
DC
GN
D
Inte
rior A
ctiv
atio
n
GN
D
Pre
senc
e 1
+24
VD
C
-0 V
DC
(Tes
t Out
put/M
onito
red)
24 V
DC
0 V
DC
GN
D
Ext
erio
r Act
ivat
ion
GN
D
Pre
senc
e 2
Pow
er S
uppl
y 1
Act
ivat
ion
Out
put
2
Pre
senc
e O
utpu
t 3
Test
Inpu
t 4
Pow
er S
uppl
y 1
Act
ivat
ion
Out
put
2
Pre
senc
e O
utpu
t 3
Test
Inpu
t 4
Gra
yG
ray
Gra
yG
ray
Whi
te
Whi
teYe
llow
Yello
w
Yello
w/B
lack
Yello
w/B
lack
Whi
te/B
lack
Whi
te/B
lack
Red
(+)
Bla
ck(-)
Red
(+)
Bla
ck(-)
Inte
rior S
enso
r
Exte
rior S
enso
r
Not
es:
1. D
ipsw
itch
14 m
ust b
e se
t ON
(UP
) for
sim
ulta
neou
s ou
tput
.2.
With
Dip
switc
h 15
ON
(UP
) the
BLU
EZO
NE
(Row
1) w
ill b
e ac
tive.
3.
Whe
n in
stal
ling
two
or m
ore
sens
ors
in c
lose
pro
xim
ity to
eac
h ot
her,
vary
the
frequ
ency
set
tings
for e
ach
sens
or (d
ipsw
itche
s 5
& 6
). 4.
Dip
switc
h 11
Act
ivat
ion
outp
ut s
tand
by m
ode
rela
y lo
gic,
"N.O
. OFF
" or "
N.C
. ON
".5.
Dip
switc
h 12
Saf
ety
outp
ut s
tand
by m
ode
rela
y lo
gic,
"N.O
. OFF
" or "
N.C
. ON
".6.
Red
& B
lack
wire
s (T
est I
nput
) are
onl
y us
ed w
hen
the
cont
rol b
ox h
as m
onito
ring
capa
bilit
y.
Top Related