Decoration Panel Provided with Filter Auto Cleaning Function
Self Cleaning decoration panel
OPERATION MANUAL
BYCQ140D7GW1
Proper Use for Effective Energy Savings•Thankyouforpurchasingtheself-cleanpanel.•Thismanualdescribessafetyconsiderationwhichshouldbeobservedduringtheuseoftheproduct.Read this manual carefully and be sure you understand the information provided before attempting to use the product. Keepthismanualwhereitisreadilyaccessibleafterreadingitthrough.Ifanotheruseroperatestheproductinthefuture,besuretohandoverthismanualtothenewuser.
•Thisoperationmanualisdedicatedtothedecorationpanelprovidedwithafilterautocleaningfunction.Readthismanualalongwiththeoperationmanualprovidedwiththewiredremotecontroller.
Operationmanual BYCQ140D7GW1 Selfcleaningdecorationpanel 4P310442-1B–10.20131
ContentsSafetyPrecautions ................................................................................... 2
NamesandFunctions .............................................................................. 5
FilterAutoCleaning .................................................................................. 8
DustCollectionfromDustBox ............................................................... 13
UsefulInformation .................................................................................. 17
BYCQ140D7GW1 OperationmanualSelfcleaningdecorationpanel4P310442-1B–10.2013 2
TheoriginalinstructionsarewritteninEnglish.Allotherlanguagesaretranslationsoftheoriginalinstructions.Togainfulladvantageoftheairconditioner’sfunctionsandtoavoidmalfunctionduetomishandling,werecommendthatyoureadthisinstructionmanualcarefullybeforeuse.Thisairconditionerisclassifiedunder"appliancesnotaccessibletothegeneralpublic".
• Theprecautionsdescribedhereinareclassifiedas WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail.
WARNING........ Failuretofollowtheseinstructionsproperlymayresultinpersonalinjuryorlossoflife.
CAUTION......... Failuretoobservetheseinstructionsproperlymayresultinpropertydamageorpersonalinjury,whichmaybeseriousdependingonthecircumstances.
• After reading, keep this manual in a convenient place so that you can refer to it whenever necessary. If the equipment is transferred to a new user, be sure also to hand over the manual.
WARNINGBe aware that prolonged, direct exposure to cool or warm air from the air conditioner, or to air that is too cool or too warm can be harmful to your physical condition and health.When the air conditioner is malfunctioning (giving off a burning odour, etc.) turn off power to the unit and contact your local dealer.Continuedoperationundersuchcircumstancesmayresultinafailure,electricshocksorfirehazards.Consult your local dealer about installation work.Doingtheworkyourselfmayresultinwaterleakage,electricshocksorfirehazards.Consultyourlocaldealerregardingmodification,repair and maintenance of the air conditioner.Improperworkmanshipmayresultinwaterleakage,electricshocksorfirehazards.Do not place objects, including rods, your fingers,etc.,intheairinletoroutlet.Injurymayresultduetocontactwiththeairconditioner’shighspeedfanblades.Bewareoffireincaseofrefrigerantleakage.Iftheairconditionerisnotoperatingcorrectly,i.e.notgeneratingcoolorwarmair,refrigerantleakagecouldbethecause.Consultyourdealerfor
assistance.Therefrigerantwithintheairconditionerissafeandnormallydoesnotleak.However,intheeventofaleakage,contactwithanakedburner,heaterorcookermayresultingenerationofnoxiousgas.Donotlongerusetheairconditioneruntilaqualifiedservicepersonconfirmsthattheleakagehasbeenrepaired.Consult your local dealer regarding what to do in case of refrigerant leakage.Whentheairconditioneristobeinstalledinasmallroom,itisnecessarytotakepropermeasuressothattheamountofanyleakedrefrigerantdoesnotexceedtheconcentrationlimitintheeventofaleakage.Otherwise,thismayleadtoanaccidentduetooxygendepletion.Contact professional personnel about attachment of accessories and be sure to use onlyaccessoriesspecifiedbythemanufacturer.Ifadefectresultsfromyourownworkmanship,itmayresultinwaterleaks,electricshockorfire.Consult your local dealer regarding relocation and reinstallation of the air conditioner.Improperinstallationworkmayresultinleakage,electricshocksorfirehazards.Be sure to use fuses with the correct ampere reading.Donotuseimproperfuses,copperorotherwiresasasubstitute,asthismayresultinelectricshock,fire,injuryordamagetotheunit.Be sure to earth the unit.Donotearththeunittoautilitypipe,lightningconductorortelephoneearthlead.Imperfectearthingmayresultinelectricshocksorfire.Ahighsurgecurrentfromlightningorothersourcesmaycausedamagetotheairconditioner.Be sure to install an earth leakage breaker.Failuretoinstallanearthleakagebreakermayresultinelectricshocksorfire.Consult the dealer if the air conditioner submerges owing to a natural disaster, such as afloodortyphoon.Donotoperatetheairconditionerinthatcase,orotherwiseamalfunction,electricshock,orfiremayresult.Do not start or stop operating the air conditioner with the power supply breaker turned ON or OFF.Otherwise,fireorwaterleakagemayresult.Furthermore,thefanwillrotateabruptlyifpowerfailurecompensationisenabled,whichmayresultininjury.
Safety Precautions
Operationmanual BYCQ140D7GW1 Selfcleaningdecorationpanel 4P310442-1B–10.20133
Do not use the product in the atmosphere contaminated with oil vapor, such as cooking oil or machine oil vapor.Oilvapormaycausecrackdamage,electricshocks,orfire.Do not use the product in places with excessive oily smoke, such as cooking rooms, or in places withflammablegas,corrosivegas,ormetaldust.Usingtheproductinsuchplacesmaycausefireorproductfailures.Donotuseflammablematerials(e.g.,hairsprayor insecticide) near the product. Do not clean the product with organic solvents such as paint thinner.Theuseoforganicsolventsmaycausecrackdamagetotheproduct,electricshocks,orfire.Be sure to use a dedicated power supply for the air conditioner.Theuseofanyotherpowersupplymaycauseheatgeneration,fire,orproductfailures.
CAUTIONDo not use the air conditioner for purposes other than those for which it is intended.Donotusetheairconditionerforcoolingprecisioninstruments,food,plants,animalsorworksofartasthismayadverselyaffecttheperformance,qualityand/orlongevityoftheobjectconcerned.Do not remove the outdoor unit’s fan guard.Theguardprotectsagainsttheunit’shighspeedfan,whichmaycauseinjury.Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units.Undercertainconditions,condensationonthemainunitorrefrigerantpipes,airfilterdirtordrainblockagemaycausedripping,resultinginfoulingorfailureoftheobjectconcerned.To avoid oxygen depletion, ensure that the room is adequately ventilated if equipment such as a burner is used together with the air conditioner.After prolonged use, check the unit stand and its mounts for damage.Ifleftinadamagedcondition,theunitmayfallandcauseinjury.Donotplaceflammablespraysoroperatespraycontainers near the unit as this may result in fire.Before cleaning, be sure to stop unit operation, turn the breaker off or remove the power cord.Otherwise,anelectricshockandinjurymayresult.
To avoid electric shocks, do not operate with wet hands.Do not place appliances that produce naked flamesinplacesexposedtotheairflowfromtheunit as this may impair combustion of the burner.Do not place heaters directly below the unit, as resulting heat can cause deformation.Be sure that children, plants or animals are not exposeddirectlytoairflowfromtheunit,asadverse effects may ensue.Do not wash the air conditioner or the remote controller with water, as this may result in electricshocksorfire.Donotplacewatercontainers(flowervases,etc.) on the unit, as this may result in electric shocksorfire.Do not install the air conditioner at any place wherethereisadangerofflammablegasleakage.Intheeventofagasleakage,build-upofgasneartheairconditionermayresultinfirehazards.Donotputflammablecontainers,suchasspraycans, within 1 m from the blow-off mouth.Thecontainersmayexplodebecausethewarmairoutputoftheindoororoutdoorunitwillaffectthem.Arrange the drain to ensure complete drainage.Ifproperdrainagefromtheoutdoordrainpipedoesnotoccurduringairconditioneroperation,therecouldbeablockageduetodirtanddebrisbuild-upinthepipe.Thismayresultinawaterleakagefromtheindoorunit.Underthesecircumstances,stopairconditioneroperationandconsultyourdealerforassistance.Do not allow a child to mount on the outdoor unit or avoid placing any object on it.Fallingortumblingmayresultininjury.Do not block air inlets nor outlets.Impairedairflowmayresultininsufficientperformanceortrouble.The appliance is not intended for use by unattendedyoungchildrenorinfirmpersons.Impairmentofbodilyfunctionsandharmtohealthmayresult.Children should be supervised to ensure that they do not play with the unit or its remote controller.Accidentaloperationbyachildmayresultinimpairmentofbodilyfunctionsandharmhealth.
Safety Precautions
BYCQ140D7GW1 OperationmanualSelfcleaningdecorationpanel4P310442-1B–10.2013 4
Do not let children play on or around the outdoor unit.Iftheytouchtheunitcarelessly,injurymaybecaused.Consult your dealer regarding cleaning the inside of the air conditioner.Impropercleaningmaycausebreakageofplasticparts,waterleakageandotherdamageaswellaselectricshocks.To avoid injury, do not touch the air inlet or aluminiumfinsoftheunit.Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit.Leavesareahotbedforsmallanimalswhichcanentertheunit.Onceintheunit,suchanimalscancausemalfunctions,smokeorfirewhenmakingcontactwithelectricalparts.Never touch the internal parts of the controller.Donotremovethefrontpanel.Touchingcertaininternalpartswillcauseelectricshocksanddamagetotheunit.Pleaseconsultyourdealeraboutcheckingandadjustmentofinternalparts.Do not leave the remote controller wherever there is a risk of wetting.Ifwatergetsintotheremotecontrollerthereisariskofelectricalleakageanddamagetoelectroniccomponents.Watchyourstepsatthetimeofairfiltercleaningor inspection.High-placeworkisrequired,towhichutmostattentionmustbepaid.Ifthescaffoldisunstable,youmayfallortoppledown,thuscausinginjury.
Operationmanual BYCQ140D7GW1 Selfcleaningdecorationpanel 4P310442-1B–10.20135
Indicator (green/red) Swing flap
Dust collection inletSuction grille
Decoration panel
Decoration corner cover
Indicator (green/red)
EL. COMPO. BOX of panel Dust box
fixing knobs (in two points)
Air filter
Dust box
Filter drive motor
S-shaped pipe
Brush drive motor
Brush unit
Decoration corner cover
Filter fixing knobs (in five points)
Brush unit fixing screw
• Theillustrationshowsthedecorationpanelprovidedwithfilterautocleaningfunctionontheconditionthatthesuctiongrilleisremoved.
IndicatorThedisplaycolorsandconditionsoftheindicatortellthefollowingcontents.
Indicatorcolor State Contents
GreenLit Theproductisinair-conditioningoperation(*)
Flashing Theproductisperformingfilterautocleaning(*)
Red
Flashingatlongintervals
Timetocollectthedustinthedustbox(withthedustdetectedbythedustsensor)
Seepage13.
Flashingatshortintervals
Thedustboxisfull,andfilterautocleaningisunavailable.
Theoccurrenceofmalfunctioningduringfilterautocleaning.
*Theproductisfactorysetnottoindicatetheseitems.
NOTEDonotusetheproductinthefollowingplaces.Oil,cigarettetar,andsteamwillresultinstickydustonthefilter,whichmaynotbecleanedproperly.Furthermore,stickydustmaycausemalfunctions.• Placeswithoilysmoke........................................ Restaurants,factories,etc.• Placeswithexcessivecigarettesmoke............... Smokingroom,etc.• Placeswithexcessivemoistureorsteam............ Restaurants,factories,etc.
*Theproductmaynotbeusedundercertainconditionsbesidesthespecificexamplesmentionedabove.ContactyourDaikindealerfordetails.
Names and Functions
BYCQ140D7GW1 OperationmanualSelfcleaningdecorationpanel4P310442-1B–10.2013 6
1. Operation mode selector button• Pressthisbuttontoselecttheoperationmodeofyourpreference.*Availablemodesvarywiththeconnectingmodel.
2. Fanspeed/Airflowdirectionbutton• UsedtoindicatetheAirVolume/Airflowdirectionsettingscreen.*AvailablefanspeedandAirflowdirectionvarywiththeconnectingmodel.
(Fordetails,refertooperationmanualofthecontroller)
3. Menu/Enter button• Usedtoindicatethemainmenu.• Usedtoenterthesettingitemselected.
4. Up button (Be sure to press the part with the symbol )• Usedtoraisethesettemperature.• Thenextitemsontheuppersidewillbehighlighted.(Thehighlighteditemswillbescrolledcontinuouslywhenthebuttoniskeptpressed.)
• Usedtochangetheitemselected.
5. Down button (Be sure to press the part with the symbol )• Usedtolowerthesettemperature.• Thenextitemsonthelowersidewillbehighlighted.(Thehighlighteditemswillbescrolledcontinuouslywhenthebuttoniskeptpressed.)
• Usedtochangetheitemselected.
2.Fanspeed/Airflowdirectionsettingbutton
3. Menu/Enter button 8. On/Off button
10. Cancel button
9. Operation lamp
11. LCD (with backlight)
4. Up button 5. Down button 6. Right button 7. Left button
1. Operation mode selector button
Functions other than basic operation items (i.e., On/Off, Operation mode selector, Fan speed control, and temperature settings) are set from the menu screen.
NOTE• Do not install the remote controller in places exposed to direct sunlight.
Otherwise, the LCD may become discolored and nothing may be displayed.• Do not pull or twist the remote controller cord.
Otherwise, the remote controller may error.• Do not press the buttons on the remote controller with objects with sharp ends.
Otherwise, the remote controller may receive damage or error.
Operationmanual BYCQ140D7GW1 Selfcleaningdecorationpanel 4P310442-1B–10.20137
6. Right button (Be sure to press the part with the symbol )• Usedtohighlightthenextitemsontheright-handside.
• Eachscreenisscrolledintheright-handdirection.• Homeleavesettingsareenabledwiththisbuttonkeptpressedforatleastfourseconds.
7. Left button (Be sure to press the part with the symbol )• Usedtohighlightthenextitemsontheleft-handside.
• Eachscreenisscrolledintheleft-handdirection.• Homeleavesettingsareenabledwiththisbuttonkeptpressedforatleastfourseconds.
8. On/Off button• Pressthisbuttonandsystemwillstart.• Pressthisbuttonagainandsystemwillstop.
9. Operation lamp (Green)• Thislamplightsupduringoperation.• Thislampblinksifaerroroccurs.
10. Cancel button• Usedtoreturntothepreviousscreen.
11. LCD (with backlight)• Thebacklightwillbelightforapproximately30secondsbypressinganyoperationbutton.OperatebuttonsexcludingtheOn/Offbuttonwhilethebacklightislit.
• Iftworemotecontrollersareusedtocontrolasingleindoorunit,thebacklightoftheremotecontrolleroperatedearlierthantheotheronewillbelit.(Thebacklightsofthetworemotecontrollerswillnotbelitsimultaneously.)
1. "Filter auto cleaning" display• Displayedwhiletheproductisperformingfilterautocleaning.
2. MessageThefollowingmessagewillappear."Error:PushMenuButton.""Warning:PushMenuButton."• Displayediftheerrororwarningisdetected.(Seepage18).
Themessages"Collectdust."and"Warning:PushMenuButton."willappearalternately.• Displayedwhenthetimetocollectthedustinthedustboxhascome.(Seepage13).
"Setclockfrommenu"• Displayedtoinformthattheclockneedssettingsagain.(Seepage10)
• Theproductwillnotstartfilterautocleaningatthedesignatedperiodunlesssettingsaremadeagain.
Liquid Crystal Display• Therearetwodisplaytypes,i.e.,standardanddetaileddisplays.Thestandarddisplayisbydefaultset.
• Togotothedetaileddisplay,selectthedetaileddisplayinthemainmenu.Fordetails,refertotheoperationmanualprovidedwiththewiredremotecontroller.
• EachofthefollowingscreensexplainsthestateoftheLCDdisplayregardingfilterautocleaningfunction.ForthecontentsoftheLCDdisplayswhiletheproductisnotinfilterautocleaningoperation,refertotheoperationmanualprovidedwiththewiredremotecontroller.
Standard display Detailed display
Auto
Collect dust
2. Message 1. "Filter auto cleaning" display
Set toCool
Heat28°C
20°C
Room
20°C
AutoCoolHeat
28°C
20°C
Setback
Fri 11:03
Collect dust
2. Message 1. "Filter auto cleaning" display
Names and Functions
BYCQ140D7GW1 OperationmanualSelfcleaningdecorationpanel4P310442-1B–10.2013 8
Operation Method
Operation screen displayDescribes screens that will be displayed on the remote controller in operation.
Operation procedureExplains a button operation procedure for the remote controller. Operate the buttons according to the procedure.
Operation button displayDisplays the positions of buttons to be operated.
Remote Controller Functions
1Return Setting
Main MenuQuick StartVentilationEnergy Saving OptionsScheduleFilter Auto CleanMaintenance Information
1/2
Return Setting
09:00–12:00
Filter Auto Clean
Filter Auto Clean
• Press buttons to select the Filter Auto Clean on the main menu screen. Press Menu/Enter button to display the Filter auto clean settings screen.
Filter Auto Clean SettingThisproductperformsfilterautocleaningonceaday.Theair-conditioningoperationoftheproductwillcometoastopwhiletheproductisperformingfilterautocleaning.Specifythedesiredperiodfromeightperiods.
NOTE• Thecorrectclocksettingsarenecessary.• Theproductwillperformfilterautocleaningfrom00:00to03:00(asfactorydefault)iftheperiodforfilterautocleaningisnotspecified.
• Theproductwillperformfilterautocleaningatnon-prescribedtimeifclocksettingsarenotmade.
�Method of Specifying Start Time
Operation Method
1 Setting
Main MenuQuick StartVentilationEnergy Saving OptionsScheduleFilter Auto CleanMaintenance Information
1/2
Return
• Displaythemainmenuscreen.• Press buttonstoselecttheFilterAutoCleanonthemainmenuscreenandpressMenu/Enterbutton.
2 Return Setting
Clock setting is not carried out. Do you want to set?
Filter Auto Clean
Yes No
Date & TimeYear 2011Month 01Day 01Thursday
12:00Return Setting
*Clocksettingsarerequiredtosetthestarttimeoffilterautocleaning.
• Iftheclockhasnotbeenset,ascreenliketheoneontheleftwillappear.Press buttonstoselectYesandpressMenu/Enterbutton.Setthecurrentyear,month,day,andtime.(See"Clock&Calendar"onpage10)
Filter Auto Cleaning
Operationmanual BYCQ140D7GW1 Selfcleaningdecorationpanel 4P310442-1B–10.20139
3 Return Setting
Filter Auto CleanFilter Auto Clean
0:00– 3:00
• Theperiodwillchangewhenever buttonsarepressedintheClocksettingscreenforfilterautocleaning.00:00–03:00,03:00–06:00,06:00–09:00,09:00–12:00,12:00–15:00,15:00–18:00,18:00–21:00,21:00–00:00.Selectthedesiredperiodfromtheonesdisplayed.
• PressMenu/Enterbutton.Thesettingsconfirmationscreenwillappear.
4 Return Setting
Save the settings?Filter Auto Clean
Yes No
• Press buttontoselectYesonthesettingsconfirmationscreen.PressMenu/Enterbuttontosetthefilterautocleanandreturntothebasicscreen.
NOTEThefilterautocleanfunctiontakesaround10minutes.Executionofthecleaningfunction,alwaysduringthescheduledtimeslotof3hours,willstartassoonaspossibleconsideringthefollowingconditions:• duringthefirsthourthecleaningfunctionwillonlybeperformedduringthermostatOFFintervalsorwhentheunitisnotoperating;
• duringthesecondhoursameconditionasduringfirsthourorwhencoolingorheatingdemandisratherlow;
• duringthethirdhourtheunitforcesexecutionofthecleaningfunction,evenwhentheunitisoperating.Aftercompletionofthecleaningfunction,theunitwillstartnormaloperationagain.
Theunitwilltrytoperformthecleaningfunctionduringthenextscheduledtimeslotof3hoursincaseitwasnotexecuted.Iftheunit,incaseofVRV,couldnotperformthecleaningfunctionafterelapseof2consecutivescheduledtimeslotsof3hours,errorcodeAH09displaysontheremotecontroller(see“NOTE”onpage18).Theerrorcoderemainsdisplayedaslongasthefunctionisnotcompleted,buttheunitcanoperatenormallyatalltimes.Skyairunitsdonotdisplaythaterrorcode.
Filter Auto CleaningTheproducthasthefollowingthreeoperationmodes,anyoneofwhichcanbesetforfilterautocleaning.
Operation mode Description
Clock setting
Availability for designating timetostartfilterauto
cleaning
Scheduledtimeroperation
Performsfilterautocleaningduringthedesignatedperiodselectedfromeightperiods.
00:00-to-03:00operation
Performsfilterautocleaningduringthefactory-setperiodoftime(00:00to03:00).
Autocontroloperation
Performsfilterautocleaningaccordingtothecontrolreference. or
Filter Auto Cleaning
BYCQ140D7GW1 OperationmanualSelfcleaningdecorationpanel4P310442-1B–10.2013 10
PREPARATION• Todesignateaperiodforfilterautocleaning,avoidselectingtheperiodsoftimewhentheproductisinairconditioningoperationasmuchaspossible.Iftheperiodforfilterautocleaningoverlapswiththatfortheairconditioningoperationoftheproduct,theproductmaystopairconditioningforciblyandstartfilterautocleaning.
• Ifthemessage"Set clock from menu"appears,makeclocksettingsagainsothatthefilterautocleaningwillbeperformedduringthedesignatedperiod.
NOTE*Theproductwillbesettoautocontroloperationmodeunlessclocksettingsaremadeagainiftheclockisresetforsomereason(e.g.,nopowerissuppliedtotheproductfor48hoursorlonger).• Theproductmaygeneratealittlenoisewhenthefilterrotatesorthedustisscrapedwiththebrush.• Thefanrotatesautomaticallyduringfilterautocleaning.
Clock & Calendar
�Setting the clock
Operation Method
1 Cool Set to
Cool 28°C
Basicscreen
• PressMenu/Enterbutton.
2 Return Setting
Main MenuQuick StartVentilationEnergy Saving OptionsScheduleFilter Auto CleanMaintenance Information
1/2
Mainmenuscreen
• Themainmenuscreenwillappear.
3 Return Setting
Main MenuConfigurationCurrent SettingsClock & CalendarLanguage
2/2 • Press buttonstoselectClock&Calendaronthemainmenuscreen.PressMenu/Enterbuttontodisplaytheclocksettingsscreen.
4 Date & TimeYear 2011Month 01Day 01Thursday
12:00Return Setting
• Select"Year"with buttons.Inputtheyearwith buttons.Holdingdownthebuttoncausesthenumbertochangecontinuously.
Operationmanual BYCQ140D7GW1 Selfcleaningdecorationpanel 4P310442-1B–10.201311
5 Date & TimeYear 2011Month 10Day 01Thursday
12:00Return Setting
• Select"Month"with buttons.Inputthemonthwith buttons.Holdingdownthebuttoncausesthenumbertochangecontinuously.
6 Date & TimeYear 2011Month 10Day 07Thursday
12:00Return Setting
• Select"Day"with buttons.Inputthedaywith buttons.Holdingdownthebuttoncausesthenumbertochangecontinuously.Daysoftheweekchangeautomatically.
7 Date & TimeYear 2011Month 10Day 07Thursday
12:00Return Setting
• Select"Hour"with buttons.Inputthehourwith buttons.Holdingdownthebuttoncausesthenumbertochangecontinuously.
8 Date & TimeYear 2011Month 10Day 07Thursday
12:21Return Setting
• Select"Minute"with buttons.Inputtheminutewith buttons.Holdingdownthebuttoncausesthenumbertochangecontinuously.
• PressMenu/Enterbutton.Thesettingsconfirmationscreenwillappear.
9 Save the settings?Date & Time
Yes No
Return Setting
• Press buttontoselectYesonthesettingsconfirmationscreen.PressMenu/Enterbuttontosettheclockandreturntothebasicscreen.
*Whilemakingfilterautocleaningsettings,thedisplaywillreturntothescreenfordesignatingaperiodforfilterautoclean.(Seepage9.)
Filter Auto Cleaning
BYCQ140D7GW1 OperationmanualSelfcleaningdecorationpanel4P310442-1B–10.2013 12
Current Settings
�Manipulating the current settings
Operation Method
1 Return Setting
Main MenuConfigurationCurrent SettingsClock & CalendarLanguage
2/2 • Displaythemainmenuscreen.(Seepage10).• Press buttonstoselectCurrentSettingsonthemainmenuscreenandpressMenu/Enterbutton.
2 Return Setting
Current SettingsVentilation rate LowVentilation mode AutoSchedule DisableDisplay Mode StandardDisplay Item OutsideFilter auto clean 00-03
• Alistshowingthecurrentsettingstatuswillappear.Press buttonstogotothenextitem.
• PressingCancelbuttontakesyoubacktothemainmenuscreen.
Ventilationrate DisplaymodeVentilationmode DisplayitemSchedule FilterautocleanQuickstart
Displayitems
*Displayitemsmaydifferdependingonthemodel.Onlytheitemsthatcanbesetaredisplayed.Refertothedisplayed"Filterautoclean"settingsforthepresentsetconditionoffilterautocleaning.Example:Aperiodfrom00:00to03:00issetforfilterautocleaning.
Filterautoclean00-33
Operationmanual BYCQ140D7GW1 Selfcleaningdecorationpanel 4P310442-1B–10.201313
Dust Collection from Dust BoxDust Collection Sign Display
Timeforcollectingdustfromthedustboxwillappearwhenthetimecomes.Promptlycollectthedustwhenthesignisconfirmed.*Thedustcollectionsignwillappearatintervalsofapproximatelyhalfayeartooneyear.Theintervalsmaybecomeshorteriftheproductisusedinplaceswithexcessivedust.
Thedustcollectionsignwillappearinastepwisemanneraccordingtothequantityofdustinthedustbox.
Place of display Collection sign 1 Collection sign 2 Collection sign 3 Collection sign 4
Remotecontroller
LCD Themessages"Collectdust"and"PressMenuButton"willappearalternately.
"AH"(errorsign)willappear
Operationlamp Noindication Theoperationlampwillflash.
DecorativecornercoverIndicator(red) Noindication
Theindicatorwillflashatlongintervals.
Theindicatorwillflashatshortintervals.
PREPARATION• Promptlycollectthedustinthedustboxoncompletionofconfirmingthedustcollectionsign.
NOTE• Controltosuspendtheairconditioningoperationoftheproductwillworkiftheairconditioningoperationoftheproductiscontinuedwithoutdustcollection.Furthermore,thedustwillfallandamalfunctionmayresult.Therefore,besuretoperformdustcollectionwithavacuumcleaner.
BYCQ140D7GW1 OperationmanualSelfcleaningdecorationpanel4P310442-1B–10.2013 14
Dust Collection with Vacuum Cleaner
1 Vacuumthedustinthedustboxoncompletionofconfirmingthedustcollectionsign.NOTE• Dustcollectionwithavacuumcleanerisnotpossibleduringfilterautocleaning.Makesurethat" "isnotdisplayedontheremotecontrollerscreenbeforedustcollection.*Theindicatorwillflashgreeniftheindicatorissettodisplay.(Seepage5).
2 Connecttheprovidedconnectionpipeandattachmenttomatchthevacuumcleanerpipe.Inserttheconnectionpipeandattachmentintothevacuumcleanerpipe.
Vacuum cleaner pipe Vacuum cleaner pipe Connection pipeConnection pipe
Attachment
Vacuum cleaner pipe with an inner diameter of 32 to 38 mm in diameter.
Vacuum cleaner pipe with an inner diameter of 38 to 42 mm in diameter.
Whenstoringtheconnectionpipe,usetheprovidedhook-and-loopfastenerstripandtakethefollowingprocedure.
Example 11.Peelthereleasepaperoffthedouble-sticktapeonthebackofthefastenerstrip,andpastethefastenerstripontoaflatsurfaceintheplaceofstorage.
2.Pressthefastenerstripoftheconnectionpipeontothefastenerstrippastedinstep1.
Flat surface in the place of storage
Connection pipe
Hook-and-loop fastener strips
Example 2Windthehook-and-loopfastenersontheconnectionpipearoundavacuumcleanerhoseorpipetostoretheconnectionpipe.
Connection pipe
Vacuum cleaner hose or pipe
Hook-and-loop fastener strips
NOTE• Theattachmentcannotbeconnectedtoavacuumcleanerpipewithoutaround-shapedleadingend(e.g.,astand-typeorhandheld-typevacuumcleaner)orapipethathasaholemidwaytocauseairleakage.ConsultyourDaikindealeriftheattachmentcannotbeconnectedtoyourvacuumcleaner.
• Useavacuumcleanerwithaminimumsuckingworkrateof300W.• Donotuseavacuumcleanerfullofdustandlowinsuctionpower.*Theuseoftheabovevacuumcleanermayresultinadustcollectionfailure.
Operationmanual BYCQ140D7GW1 Selfcleaningdecorationpanel 4P310442-1B–10.201315
3 Inserttheleadingendoftheconnectionpipeintothedustcollectioninletofthesuctiongrillefromrightunder.Thenpressfittheleadingendontointernalairinletuntiltheleadingendsnaps.
Dust collection inlet Connection pipe
Rises approximately 10 mm
Internal cross section of dust collection inlet
Air inlet
4 Whiletheleadingendoftheconnectionpipecloselycomeincontact,turnonthevacuumcleanerwiththesuctionpowersettomaximumandvacuumthedust.
5 Iftheindicatoronthedecorativecornercoverisflashingred,theindicatorwillbeturnedofforlitgreenoncompletionofdustcollection.
*Itmaytakeamaximumof30secondsfortheindicatorflashingredtobeturnedofforlitgreen.
Dust Collection from Dust Box
BYCQ140D7GW1 OperationmanualSelfcleaningdecorationpanel4P310442-1B–10.2013 16
Resetting Dust Collection Sign
Operation Method
1 Auto28°C
20°C
Zbierz kurz
UstawChł.Grz.
Basicscreen
• Whenthetimeforcollectingdustfromthedustboxcomes,thedustcollectionmessages"Collectdust."and"PressMenuButton."willappearalternatelyonthelowerpartofthebasicscreen.
• Atthetimeofthisstate,presstheMenu/Enterbuttononthebasicscreen.
2 Return Setting
Dust Collection Method • Anillustrationofvacuumingdustfromthedustcollectioninletwillappear.(See"DustCollectionwithVacuumCleaner"onpage14)
• Afterunderstandingthemethodofdustcollection,presstheMenu/Enterbuttonatthetimeofthisstate.
3 Return Setting
Was dust collected?Dust Collection Method
Yes No
Cool Set toCool 28°C
• Aftervacuumingthedustinthedustbox,press buttonsonthecollectionconfirmationscreenandselectYes.
• PresstheMenu/Enterbuttontoresetthedustcollectionsign.• Themessages"Collectdust."and"PressMenuButton."appearingalternatelyonthebasicscreenwilldisappear.
*Ifthedustinthedustboxisnotvacuumedatallorproperly,thedustcollectionsignwillappearsoon.
Operationmanual BYCQ140D7GW1 Selfcleaningdecorationpanel 4P310442-1B–10.201317
TroubleshootingThefollowingsymptomsarenotsignsofmalfunctions.
Symptom Probable cause
Slight clicking noise is generated.
The" "isdisplayedortheindicatoronthepanelisflashinggreen(*).
Thedrivingsoundoftheairfilter.
Scorching noise is generated. Thedrivingsoundofthebrush.
The fan automatically turns. Theproductisperformingfilterautocleaningandtransferringdust.
Theswingflapautomaticallymoves.
Theproductblowsoutairhorizontallyduringfilterautocleaning.
The air conditioning operation of the product stops temporarily. Thedustboxisfull,andfilterautocleaningisunavailable.
*Thefactorysettingswillnotallowtheindicatortoflashgreen.
Checkbeforerequestingservicing.
Symptom Probable cause Remedy
Duststickstotheairfilter(dustfalls).
Theroomhasalargequantityofdusttemporarilyasaresultofthecleaningoftheroom.
Stoptheoperationoftheairconditioneruntilthecleaningoftheroomisfinished.
Thedustboxisfull. Vacuumthedust.(Seepage14).
The display "AH" will appear on screen of the remote controller and the operation lamp will flash.
Thedustboxisfull. Vacuumthedust.(Seepage14).
The dust collection sign appears soon after the dust is vacuumed.
Isthevacuumcleanernotfullwithdust?
Collectthedustfromthevacuumcleaner.
The product does not run according to the timer settings.
Arethesettingsintheremotecontrollerwrong?
Makesettingsintheremotecontrolleragain.
Iftheproductisstillnotingoodconditionaftercheckingtheabove,contactyourDaikindealer.Thecustomermustnotattempttorepairtheproduct.
Useful Information
BYCQ140D7GW1 OperationmanualSelfcleaningdecorationpanel4P310442-1B–10.2013 18
�Contact your Daikin dealer in the following cases
• When the air conditioner is malfunctioning (e.g., giving off a burning odor), stop the air conditioner and turn off power.Continuedoperationundersuchcircumstancesmayresultinfailure,electricshocks,orfire.ContactyourDaikindealer.
SymptomMeasures to be taken before requesting
servicing
The fuse blows out or safety devices, such as the power circuit breaker and earth leakage circuit breaker trip often. Donotturnontheproduct.
The operation of the buttons on the remote controller is inaccurate. Turnofftheproduct.
There are other malfunctions or faults. Stoptheoperationoftheproduct.
Cool
Return Setting
Set toCool 28°C
Error : Press Menu Button
Either one of the following messagesflashesonthebasicscreen of the remote controller.
"Error: Push Menu Button."*Theoperationindicatorwillblink.
"Warning: Push Menu Button."*Theoperationindicatorwillnotblink.
Checkthemalfunctioncodes.(Seebelow)
Error code Display
Operation Method
1 Cool
Return Setting
Set toCool 28°C
Error : Press Menu Button
• Ifanerroroccurs,eitheroneofthefollowingitemswillblinkinthebasicscreen."Error:PushMenuButton."*Theoperationindicatorwillblink.
"Warning:PushMenuButton."*Theoperationindicatorwillnotblink.
• PressMenu/Enterbutton.
Operation lamp
2 Return
Error code:A1
Indoor Model –––/000Outdoor Model –––/000
Contact Info0123–4567–8900
• Theerrorcodeblinksandthecontactaddressandmodelnamewillappear.
• NotifyyourDaikindealeroftheErrorcodeandModelname.
NOTE
Insomecase,AH09canbedisplayedontheremotecontroller.Thiserrorcodemeansthatthecleaningoperationcouldnotbeperformedduetooverlappingoperationtiming(coolingorheating)andthecleaningschedule.Thiscanbeavoidedbysettingthecleaningfunctionoutofthenormaloperationschedule.(E.g.,normaloperationstopsat23:59andcleaningstartsat00:00).
Operationmanual BYCQ140D7GW1 Selfcleaningdecorationpanel 4P310442-1B–10.201319
Useful InformationAfter-sale Service
• Do not disassemble, modify, or repair the unit.Doingsomayresultinelectricshocksorfire.ContactyourDaikindealer.
• Do not relocate or reinstall by yourself.Improperinstallationmayresultinelectricshocksorfire.ContactyourDaikindealer.
• Bewareoffireincaseofrefrigerantleakage.Iftheairconditionerisnotoperatingcorrectly,i.e.notgeneratingcoolorwarmair,refrigerantleakagecouldbethecause.ContactyourDaikindealerforassistance.Therefrigerantwithintheairconditionerissafeandnormallydoesnotleak.However,intheeventofaleakage,contactwithanakedburner,heaterorcookermayresultingenerationofnoxiousgas.Donotlongerusetheairconditioneruntilaqualifiedservicepersonconfirmsthattheleakagehasbeenrepaired.
�Advise the repairer of the following items• Modelname• Dateofinstallation• Failureconditions:Aspreciseaspossible.• Youraddress,name,andtelephonenumber
�Repairs after Expiration of Cost-free Guarantee Repair PeriodContactyourDaikindealer.Daikinwillconductpaidrepairsiftheproductisrepairablewithitsfunctionsmaintained.
�Stock Period of Performance Spare PartsPerformancesparepartsarecomponentsthatarerequiredtomaintainthefunctionoftheproduct.Daikinhasastockofperformancesparepartsfortheairconditionerfornineyearsafterthestoppageofproducingtheairconditioner.
�Recommendation for Maintenance Inspection ContractTheinterioroftheairconditionerwillbecomedirtywithitsperformancedegradediftheairconditionerisusedforseveralseasons.Aspecializedtechniqueisneededfortheoverhaulingorinternalcleaningoftheproductapartfromusualmaintenancework.Therefore,Daikinrecommendsapaidmaintenanceinspectioncontract.However,thisproductperformsfilterautocleaning.Therefore,thecustomer’severydaycareoftheproductisnotnecessary.Therewillbeanadverseinfluenceontheproduct,suchasthecloggingofthefilter,dependingontheenvironmentalandoperatingconditionsoftheproduct.Therefore,Daikinrecommendsmaintenanceinspectionsatthefollowinginspectionintervals.
BYCQ140D7GW1 OperationmanualSelfcleaningdecorationpanel4P310442-1B–10.2013 20
�Rough Standards for Inspection and Maintenance Frequencies[Keepinmindthatthemaintenancefrequenciesdonotindicateguaranteedoperatingperiodsoftheparts.]
Table1appliessubjecttothefollowingoperatingconditions.(1)Theproductisundernormalusagewithoutbeingoperatedandstoppedfrequentlyatshortintervals.
(Theproductundernormalusagereferstotheoperatingconditionoftheproductstartedandstoppedamaximumofsixtimesanhour,thefrequencyofwhichvariesmoreorlessdependingonthemodel.)
(2)Theproductisdeemedtooperate10hoursadayand2,500hoursayear.
• Table1InspectionandMaintenanceFrequencies
Main part nameInspection
periodMaintenance frequency [replacement or repair]
Motor(forlouver,filter,brush,anddamper)
1year
20,000hours
Brushunit 3year
Dustbox 8year
FlexiblehoseandS-shapedpipe 8year
LEDindicator 5year
PCB 25,000hours
Note:1.Thistableshowsmainparts.Fordetails,refertothemaintenanceinspectioncontract.2.Themaintenancefrequencyofeachpartindicatesaroughperiodrequireduntilthemaintenanceofthepartbecomesnecessary.Makeuseofthetableforappropriatemaintenancedesigning(e.g.,thebudgetingofmaintenanceinspectioncost).Furthermore,theinspectionandmaintenancefrequenciesmaybeshorterthanthosespecifiedinthetable,dependingonthecontentofthemaintenanceinspectioncontract.
3.TheproductrequiresregularinspectioniftheproductisusedinbuildingstowhichtheLawforMaintenanceofSanitationinBuildingsapplies.
4.Themaintenanceandreplacementfrequenciesofeachpartmustbeshortenedundertoughoperatingconditions(e.g.,longeroperatinghoursandhighlyfrequentON/OFFtimes)andoperatingenvironments(e.g.,environmentswithhigh-temperature,high-humidity,excessivelydusty,andoilyatmospheres).
Fordetails,contactyourDaikindealer.
�Rough Standards for Part Replacement Frequency[Keepinmindthatthereplacementfrequencydoesnotindicatetheguaranteedoperatingperiodofthepart.]
• Table2.Replacementfrequency
Main part name Inspection period Replacement frequency
Filter 1year 5year
Note:1.Thistableshowsmainparts.Fordetails,refertothemaintenanceinspectioncontract.2.Thereplacementfrequencyindicatesaroughperiodrequireduntilthereplacementofthepartbecomesnecessary.Makeuseofthetableforappropriatemaintenancedesigning(e.g.,thebudgetingofpartreplacementcost).
3.Regularinspectionisrequired,dependingontheinstallationenvironment.Fordetails,contactyourDaikindealer.Furthermore,theoverhaulingorinternalcleaningoftheproductconductedbyrepairersotherthanthoseauthorizedbyDaikinmaynotbewithinthescopeofDaikin’sproductguaranteeterm.
Operationmanual BYCQ140D7GW1 Selfcleaningdecorationpanel 4P310442-1B–10.201321
�RelocationContactyourDaikindealerbecausethesamerequiresaspecializedtechniqueinthecaseofrelocatingandreinstallingtheairconditionerforsomereason,e.g.,themovementofthesite.
�InquiryContactyourDaikindealerforafter-saleservices.
Useful Information
Copyright2012Daikin
4P310442-1B10.2013
*4P310442-1 B 0000000S*