iManager M2000 Performance Management
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page3
Objectives
Upon completion of this course, you will be able to:
Know the function of performance management in
M2000
Operate performance management via M2000
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page4
Contents
1. Performance Management Basic
2. Performance Management Preferences
3. Performance Database Capacity Parameters
4. Measurement Management
5. User-Defined Counter Management
6. Query Performance Result
7. Other Functions
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page5
Measurement not set
Discard
Overall Procedure of PM
Performance Data
Mediation Analysis M2000 Server
Measurement Counter
Measurement Object
Northbound Export
Northbound Export
Display Results
Export Results to Server
Threshold Check
Threshold Alarm
Generated
Threshold Exceeded?
Measurement Period Reaches
NEs
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page7
Measurement not set
Discard
Procedure of Supplementary Data Collection
Performance Data
Mediation Analysis M2000 Server
Measurement Counter
Measurement Object
Display Results
Threshold Alarm
Generated
Results Missing ?
Measurement Period Reaches
NEs
Synchronized Performance
Data
Normal Procedure
Synchronization Procedure
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page8
Three factors of PM Counter WHAT
Normal counter : default counter + extended counter
User-defined counter
Object WHO
Physical concept ( Board/Cabinet ) Logical concept ( BSC, Cell, TRX )
Period WHEN
5 Minutes, 15 Minutes, 30 Minutes, 60 Minutes, 24 Hours
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page9
Three factors of PM
Object(Logical concept)
Period Counter
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page10
Performance Measurement Counter Hierarchical structure of performance counters
Function subset m
Function subset 1
Function set 1
……
…Function set n
Counter 1
Counter j
Counter 1
Counter k
PERFORMANCE
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page11
Performance Measurement Counter
Function set
Function subset
Counter
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page12
Contents
1. Performance Management Basic
2. Performance Management Preferences
3. Performance Database Capacity Parameters
4. Measurement Management
5. User-Defined Counter Management
6. Query Performance Result
7. Other Functions
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page13
PM Preferences
or
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page14
Contents
1. Performance Management Basic
2. Performance Management Preferences
3. Performance Database Capacity Parameters
4. Measurement Management
5. User-Defined Counter Management
6. Query Performance Result
7. Other Functions
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page15
Performance Database Capacity Parameters
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page16
Performance Database Capacity Parameters
M2000 Server
Display Results
exports the performance data whose storage duration expires
File1.csv or File1.zipFile2.csv or File2.zip
…
Performance Database
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page17
Contents
1. Performance Management Basic
2. Performance Management Preferences
3. Performance Database Capacity Parameters
4. Measurement Management
5. User-Defined Counter Management
6. Query Performance Result
7. Other Functions
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page18
Procedure for Performance Query
Measurement Settings
Query Result
•Counter
•Object
•Period
•By new condition
•By template
Step 1
Step 2
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page19
Measurement Setting
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page20
Measurement SettingPeriod Count
erObject
The system automatically issues measurement tasks to the new objects or new NEs
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page21
Contents
1. Performance Management Basic
2. Performance Management Preferences
3. Performance Database Capacity Parameters
4. Measurement Management
5. Customer Counter Management
6. Query Performance Result
7. Other Functions
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page22
Customer Counter According to the existent measurement counters, to define a
user-required measurement counter by using the arithmetic.
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page23
Customer Counter
The existent user-defined
counters
Enter the dialog box in next page
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page24
Customer Counter
Put the constant in parenthesis
The candidate original counters
For example: (Counter1+Counter2)*{100}/(Counter3+Counter4+Counter6)
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page25
Contents
1. Performance Management Basic
2. Performance Management Preferences
3. Performance Database Capacity Parameters
4. Measurement Management
5. User-Defined Counter Management
6. Query Performance Result
7. Other Functions
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page26
Query Performance Results
Two kinds of query mode
By new conditions
By template
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page27
Query by New Conditions
This is a user-defined counter
Grey means this counter is not available
Introduce it in the next page
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page28
Query by New Conditions
Some counters can be queried by ‘Busy
Hour’
After condition setting, we can save it as query
template
If some objects were deleted, the history results can be queried by this
way
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page29
Query by Template
The existent template list
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page30
Contents
1. Performance Management Basic
2. Performance Management Preferences
3. Performance Database Capacity Parameters
4. Measurement Management
5. User-Defined Counter Management
6. Query Performance Result
7. Other Functions
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page31
Other Functions
Abnormal status processing
Browse measurement status
Query missing result
Manage integrity
Synchronize result
Additional functions
Performance counter threshold management
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page32
Browse Measurement Status
Legend
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page33
Querying Missing Result During the M2000 running,
measurement results may be
missing due to many
reasons, such as the
disconnection of NEs from
the M2000 within a period of
time. If measurement results
are lost, you can synchronize
the measurement results to
obtain the missing results.
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page34
Querying Missing Result
The missing informationor
or
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page35
Managing Integrity
Integrity management includes two parts
Integrity monitor
Querying the integrity of current results
Integrity query
Querying the integrity of historical results
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page36
Integrity Monitor
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page37
Integrity Monitor
A maximum of 5 measurement periods, 10 NEs, and
10 function subsets are allowed.
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page38
Integrity Query
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page39
Integrity Query
A maximum of 5 measurement periods, 10 NEs, and
10 function subsets are allowed.
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page40
Synchronizing Measurement Results To obtain the missing measurement results by synchronizing
measurement results. (via the dialog box in this page or next page)
way1
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page41
Synchronizing Measurement Results
way2
way3
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page42
Synchronizing Measurement Results
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page43
Performance Counter Threshold Benefits
Monitor the actual measurement result of the counters. When
the value of the measurement result exceeds that threshold
set by the user, the system generates an alarm.
Types:
Simple threshold
The threshold defined for a single counter
Combined threshold
The threshold defined for the value obtained by logic or
arithmetic operations of multiple counter values.
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page44
Simple Threshold
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page45
Threshold Alarm
Minor Alarm
Critical Alarm
Critical Alarm Cleared
Minor Alarm Cleared
110
100
90
45
40
35
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10 t11t12
Higher the value, worse
the circumstance
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page46
Threshold Alarm
Minor Alarm
Critical Alarm
Critical Alarm Cleared
Minor Alarm Cleared110
100
90
45
40
35
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10
Lower the value, worse
the circumstance
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page47
Combined Threshold
Set the formulas as the next
page
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page48
Combined Threshold
Logic combinatio
n
“Counter name” is changed according to the “Fileter by Counter Type”
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page49
Question and Practice
1. Please save a traffic statistic result and satisfy the following
condition:
2. Use the template function to get a traffic statistic result and
satisfy the condition listed above.
Object BSC6900_67 or others (according to the practical condition)
Counter all counters in Call measurement/KPI measurement per cell
Time busy hours in the morning & afternoon & evening
Day the last two days
Period 15 Minutes / 60 Minutes / 24 Hours
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page50
3. Use the “Customer Counter” function to define two counter as
following Function Set: MR Measurement
Function Subset: Uplink-and-Downlink Balance Measurement per TRX
Counter A:
Name1: Downlink Worse Formula information1:
Counter B: Name2: Uplink Worse Formula information2:
Question and Practice
S462A:Number of MRs (Uplink-and-Downlink Balance Level = 1)+S462B:Number of MRs (Uplink-and-Downlink Balance Level = 2)+S462C:Number of MRs (Uplink-and-Downlink Balance Level = 3)
S462A +S462B+S462C+S462D+S462E+S462F+S462G+S462H+S462I+S462J+S462K×100 %
S462I:Number of MRs (Uplink-and-Downlink Balance Level = 9)+S462J:Number of MRs (Uplink-and-Downlink Balance Level = 10)+S462K:Number of MRs (Uplink-and-Downlink Balance Level = 11)
S462A +S462B+S462C+S462D+S462E+S462F+S462G+S462H+S462I+S462J+S462K×100 %
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page51
Question and Practice
Object BSC6900_67 or others (according to the practical
condition)
Threshold name K3041:TCH Congestion Rate (Overflow)
Time information 15 Minutes / 60 Minutes / 24 Hours
Activation Date All date in Jan. and Aug.
Period 60 Minutes
Threshold type Simple
Direction Increasing
Function subset Call Measurement / KPI Measurement per Cell
Counter name K3041:TCH Congestion Rate (Overflow)
Threshold Critical: 5 Major: 2 Minor: 1 Warning: 0.5
Hysteresis 0.5 0.5 0.2 0.2
4. Set a threshold to a counter as following and query its
alarm
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page52
Question and Practice
Object BSC6900_67 or others (according to the practical
condition)
Threshold name Downlink Worse and Uplink Worse
Time information 15 Minutes / 60 Minutes / 24 Hours
Activation Date All date in Jan. and Aug.
Period 60 Minutes
Threshold type Combined
Alarm level Critical
Function subset Please look for the counter——”Downlink Worse” and
“Uplink Worse” defined before?Counter name
Triggering Downlink Worse>90% or Uplink Worse>90%
Recovering Downlink Worse>20% and Uplink Worse>20%
5. Set a threshold to a counter as following and query its
alarm
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page53
Summary
The function of performance management
The operation of performance management
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page54
Thank youwww.huawei.com
Top Related