1
MPPC Test Setup
Alam Toro S.
2
Objective
• Characterize main variables in ideal conditions• To provide a setup to characterize multiple
devices• To provide a Closed Volume with controlled
temperature
3
Main Idea
Closed Volume
Electronic Readout
Main Support
4
MPPC, Plates and Pipe
Direct Contact Plate
Fixing Plate
Hole for Screw
HAMAMATSU MPPC
5
MPPC, Plates and Pipe
Direct Contact Plate
Fixing Plate HolesCooling Pipe
6
Contact Board•Electronic Readout inject
heat inside the volume•Unknown Changes in
Amplifier Gain due to change in temperature
•For this reason we put the electronic readout outside the closed volme
7
4 MPPC Assembly
Electric Contact due to Pressure
One single Plate and one single
pipe for 4 MPPC
Electric contact outside the main volume
8
Main SupportSupport for 16 MPPC
9
Main Support
MPPC inset
Fiber hole
Fiber end
10
16 MPPC Assembly
Cooling Pipe
11
16 MPPC Assembly
12
16 MPPC Assembly
Electronic Board Connected outside the volume
13
END