EX PRODUCTS
With this catalogue, Tramontina is proud to introduce
its newest business line: solutions for installations
in explosive atmospheres and non-classified
industrial areas, which are sold under the
Tramontina Ex label.
Tramontina is responsible for all stages of production
of Ex products: the planning, manufacturing, assembly
and delivery of products ready for installation. Control
and approval - both under the company’s Engineering
Department - are essential for meeting the technical
requirements of these stages of production.
Division Ex products combine safety, design,
outstanding finish, high quality and the technological
excellence of TRAMONTINA Eletrik S.A., - the industrial
unit of the group specialized in the manufacture of high
and low voltage electrical products.
Notable items from the Division Ex family of
products - products for explosive atmospheres:
• Conduit outlets and junction boxes CAEx and control
stations CPEx are injected with copper-free aluminum
and have excellent coating.
• Conduit outlets and junction boxes CBEx are flexible
for the positioning of threaded entries and mounting
the terminals.
• Control panels CCEx make it easy to attend to
demand as the Certification of these products permit
assembling different electrical and electronic equipment.
• Pilot and control stations ACEx are made of stainless
steel for greater mechanical and corrosion resistance.
• Plugs BUEx are noteworthy as they can be produced
in stainless steel, copper-free aluminum, naval brass or
galvanized steel.
• Plug and Outlets DXN, with Ex de protection, have
excellent mechanical and electrical resistance, with the
parts easily assembled as needed.
THE COMPANY
At its ten factories, Tramontina produces 18,000
different items. These items include cookware,
tableware, knives, stainless steel household utensils,
cooktops, range hoods, sinks and containers, electrical
material for household and industrial use, tables
and chairs in wood and plastic, as well as tools for
agriculture, construction and gardening, and highly-
specialized manual tools. To successfully distribute its
products, Tramontina invests in production, logistics and
marketing technology, which enables the company’s
label to be present in over 120 countries.
Tramontina also values social responsibility and
respect for the environment because it believes that
caring for our planet is a way of ensuring a good quality
of life for everyone.
More important than the fact that Tramontina’s
“capital” is Brazilian, is the importance of its human
capital. That is why Tramontina counts on the
professional and personal growth of its team, totaling
6 thousand employees.
However, a company can accomplish all of the above
only with the support of its partners. For this reason,
a primary objective is to focus on our clients and
customers. Tramontina has always been recognized
for its high quality. Always respectful and well-
respected. Always trusting and trustworthy. This is the
type of relationship that Tramontina believes in.
TRAMONTINA ELETRIK S.A., FOUNDED IN
1976, OCCUPIES 24,000 SQUARE METERS
OF SPACE TODAY. LOCATED IN CARLOS
BARBOSA, IN THE STATE OF RIO GRANDE
DO SUL, ITS 400 EMPLOYEES MANUFACTURE
SWITCHES, ELECTRICAL OUTLETS, DUCTS,
EXTENSIONS, JUNCTION BOXES, ACCESSORIES
FOR ELECTRICAL DUCTS, WEATHER PROOF
APPARATUS, TECHNICAL PARTS, PARTS FOR
ELECTRICAL POWER TRANSMISSION GRIDS.
Certification ISO 9001:2008
ISO 9001 certification was received in 1985.
The objective is to standardize the processes
for the manufacture of TRAMONTINA Eletrik’s
products. Standardization will result in better
quality products that satisfy customers,
employees, suppliers and the general public.
Product Certification
The product certification guarantees the
consumer that regulations for safety, reliability,
basic features, protecting the user’s health and
protecting the environment are met.
CERTIFICATIONS
LEVEL 1DIVISIONS
LEVEL 2 FAMILIES
LEVEL 3LINES
TRAMONTINA ELETRIK S.A
JOINT BOXES
FAMILY
CAEx Line
CBEx Line
CCEx Line
CPEx Line
CEEx Line
ACCESSORIES AND
CONEXIONS FAMILY
Pilot and Control Stations - ACEx
Plugs - BUEx
Press Cables - PCEx
Thread Adaptors - ADEx
Breather Drain - DREx
PLUGS AND
OUTLETS FAMILY
Plugs and Socket-Outlets - DXN
MANUFACTURING PROGRAM
ELETRICAL
DIVISIONBUILDING DIVISION
TECHNO PARTE
DIVISIONEX DIVISION
STREAMING FAMILY
Markers Line
Corona Rings Line
Suspension Clamps Line
Shield Wire Strain Clamps Line
Compression Dead-end
Clamps Line
Parallel Connector Line
Compresssion Joint Splice Line
Repair Sleeves Compression Line
Compression Dies Line
DISTRIBUITION FAMILY
Shield Wire Strain Clamps Line
Electrical Connectors Line
Anti-Oxide Compound Line
Nut and Whaser Line
Secundary Frame and Pole Belt
Line
Pole Gains Line
Isolator Pins Line
Arrester and Cutout
Brackets Line
Wire Rope Thimbles Line
Polymers Line
Preform Line
AUTOMOTIVE FAMILY
ASSOCIATED FAMILY
MISCELLANEOUS
FAMILY
SWITCHES FAMILY
IzyFlat Line
Giz Line
Liz Line
LizCor Line
Lux2 Line
LizFlex Line
Tablet Line
Trii Line
Lux Line
Priscus Line
EXTENSIONS FAMILY
Extensions Line
Multiple Extensions Line
Multiple Outlets Line
Phone Extensions Line
CONDUIT BOXES
FAMILY
Fixed Boxes Line
Multiples Boxes Line
Double and Triple Boxes Line
Floor Boxes Line
Pass Trough Line
Model American Line
Plastibox Line
ACCESSORIES FOR
ELECTRICAL DUCTS FAMILY
Straight Connectors
Curved Connectors
Press Cable Connectors
Pushing and Washers
Clamps
WEATHER-PROOF
DEVICES FAMILY
Shielded Devices
Signaling Devices
Inlay Devices
Devices for Visible Installations
Conduit Boxes
INLAY PLASTIC BOXES
FAMILY
Inlay Plastic Boxes
Clamps
Flexible Conduit
Adhesive Tapes
Spiral Tube
Connectors
MISCELLANEOUS
FAMILY
Exhibitors Line
COPPER PRODUCTS
FAMILY
Ground Rods
Terminal Compression
Compression Splice Sleeves
Grouding connectors
TECHNICAL FEATURES 06
1. Products for Hazardous Areas
CAEx 13
Explosion Proof Conduit Outlets and Juction Boxes
CBEx 17
Explosion Proof Conduit Outlets and Juction Boxes
CCEx 21
Explosion Proof Conduit Outlets Boxes and Panels
CPEx 29
Explosion Proof Control Station
ACESSORIES AND CONEXIONS 33
Explosion Proof Pilot And Control Stations [ACEx],
Plugs [BUEx], Thread Adaptors [ADEx]
and Breather Drain [DREx] for Explosive Atmosphere
CEEx 43
Increased Safety and Intrinsic Safety Junction Boxes
PCEx 51
Explosion-proof and Increased Safety Cable Glands
DXN 58
Plugs And Socket-Outlets for Explosive Atmospheres
2. Products for Non-Hazardous Areas
CONDUIT BOXES 65
CONDUIT ACCESSORIES 81
WEATHER-PROOF PRODUCTS 87
INDEX
6
EXPLOSIVE ATMOSPHERES
1. BASIC PROPERTIES OF FLAMMABLE SUBSTANCES
To study the classification of areas it is fundamental to
learn about the four properties of flammable substances
[gas, vapor, liquid or combustible dust]:
• Relative Density
The density of a gas or a vapor relative to the density
of air. Gas or vapor with relative density less than
1 [lighter] rises. Gas or vapor with relative density
greater than 1 [heavier] falls.
• Flash Point
The minimum temperature at which a liquid gives off
sufficient vapor to form an ignitable mixture.
• Ignition temperature
The lowest temperature at which a flammable
substance will spontaneously ignite in a normal
atmosphere without an external source of ignition.
• Flammable Limits
Also called Explosive Limits.
Lower Explosive Limit [LEL]: low concentration of
flammable substance and / or too much oxygen
[lean mixture].
Upper Explosive Limit [UEL]: high concentration of
flammable substance and / or low oxygen [rich mixture].
The range between these two limits is known as
Flammable Range: the explosive atmosphere can only
occur between these limits.
2. EXPLOSIVE ATMOSPHERE
An explosive atmosphere occurs when the mixture of
oxygen [air] with flammable substances is such that an
ignition source [spark, electrical spark or hot surface]
can cause an explosion. The explosion will only occur
with these three elements in the proper proportions.
HYDROGEN
LIQUEFIED
PETROLEUM
GAS
H2
D <1GLP
D >1
RELATIVE DENSITY
AR=1
H2
Upper Explosive Limit [UEL]
Flammable Limits
Lower Explosive Limit [LEL]
OXYGEN
EXPLOSION
FLAMMABLE
SUBSTANCE
IGNITION
SOURCE
7
3. HAZARDOUS AREAS
Hazardous areas are places where there is a possibility
of formation of explosive atmospheres due to the
presence of flammable substances.
4. HAZARDOUS AREA CLASSIFICATION
The classification of hazardous areas is a study that has
the purpose of identifying the areas where there is the
possibility of a potentially explosive atmosphere to form,
evaluating the properties of the flammable substances,
equipment features, ventilation and temperature of the
environment, among others.
4.1 Zone Classification
The concept of Zone Classification refers to the
frequency and duration of the presence of an explosive
atmosphere in the area.
a] Areas with the presence of Gas or Vapor
Zone 0: area in which an explosive atmosphere is
present continuously or for long periods or frequently.
Zone 1: area in which an explosive atmosphere is likely
to occur during normal operation.
Zone 2: area in which an explosive atmosphere is not
likely to occur during normal operation, but if it does
occur, it will persist for a short period only.
b] Areas with the presence of Combustible
Fuel
Zone 20: an area in which an explosive atmosphere is
present continuously or for long periods or frequently.
Zone 21: area in which an explosive atmosphere is likely
to occur during normal operation.
Zone 22: area in which an explosive atmosphere is not
likely to occur during normal operation, but if it does
occur, it will persist for a short period only.
Typically, the industry considers the following durations of
flammable substances emissions:
Zones 2 and 22: 0 to 10 hours/year.
Zones 1 and 21: 10 to 1.000 hours/year.
Zones 0 and 20: above 1.000 hours/year.
Note: The year has 8760 hours.
4.2 Group Classification
A system of classifying equipment according to its use.
Equipment for explosive atmospheres is divided into
three groups:
Group I: Equipment intended for use in the Mining
Industry
Group II: Equipment intended for use in places with
potentially explosive atmospheres of gas or vapor
[surface industries]. Group II is subdivided into three
groups according to the characteristics of gases:
IIA: represents Propane.
IIB: represents Ethylene.
IIC: represents Hydrogen and Acetylene.
IIA equipment is only used for IIA areas. IIB equipment
can be used for both IIA and IIB areas. Equipment
marked IIC or II can be used for IIA, IIB and IIC areas.
Group III: Equipment intended for use in places with
an explosive dust atmosphere. Group III is subdivided
into three groups according to the characteristics of
combustible dust:
IIIA: combustible fibers.
IIIB: non-conductive dusts.
IIIC: conductive dusts.
IIIA equipment can only be used for IIIA areas. IIIB
equipment can be used for both IIIA and IIIB areas.
Equipment marked IIIC or III can be used for IIIA, IIIB
and IIIC areas.
COMPARATION BETWEEN NORMS NBR/IEC AND NEC
NBR/IEC NEC FLAMMABLE SUBSTANCE
ZONE 0 AND 1 DIVISION 1
ZONE 2 DIVISION 2
I GASES OF MINES Metano [GRISU]
II A D Propane, Ethane, Kerosene.
II B C Cyclopropane, Ethylene
II CA Acetylene
B Hydrogen
GA
S G
RO
UP
CLA
SSE
I
SUR
FAC
E IN
DU
STRY
8
EXPLOSIVE ATMOSPHERES
5. MAXIMUM SURFACE TEMPERATURE
The highest temperature any part of or the entire
surface of an electrical device can reach under normal
and fault conditions.
The equipment’s temperature classification should be
lower than the ignition temperature of combustible
substances.
6. TEMPERATURE CLASSES
System of classifying equipment according to the
maximum surface temperature.NORM NBR IEC NORM NEC
Class
Maximum Surface
Temperature [ºC]
Class
Maximum Surface Temperature
ºF
T1 450 T1 450 842
T2 300
T2 300 572
T2A 280 536
T2B 260 500
T2C 230 446
T2D 215 419
T3 200
T3 200 392
T3A 180 356
T3B 165 329
T3C 160 320
T4 135T4 135 275
T4A 120 248
T5 100 T5 100 212
T6 85 T6 85 185
Flammable Substance
Ignition Temperature
Temperature Class of the Equipment
Maximum Surface
Temperature
Hydrogen 560 ºC T1 a T6 450°C
Acetylene 305 º C T2 a T6 300°C
Gasoline 280 ºC T3 a T6 200°C
Diethyl Ether 185 ºC T4 a T6 135°C
Carbon Disulfide 102 º C T5 a T6 100°C
Carbon Sulphide 90 ºC T6 85°C
9
7. TYPES OF PROTECTION
ProtectionTypes of
ProtectionZone
ClassificationSymbol Description
NBR IEC
Standard
ExplosionProof
dZones
1 and 2
Type of protection in which the parts which can ignite an explosive atmo-sphere are placed in an enclosure which can withstand the pressure de-veloped during an internal explosion of an explosive mixture and which prevents the transmission of the explosion to the explosive atmospheres
surrounding the enclosure.
60079-1
IncreasedSafety
eZones
1 and 2
Type of protection in which measures are applied so as to prevent with a higher degree of safety the possibility of excessive temperatures and of the occurrence of arcs or sparks in the interior and on the external parts of electrical apparatus, which does not produce them in normal service.
60079-7
Non-sparking n Zone 2A type of protection applied to electrical apparatus such that, in normal
operation, it is not capable of igniting a surrounding explosive gas atmo-sphere and a fault capable of causing ignition is not likely to occur.
60079-15
Intrinsically Safe
ia
ib
ic
Zone 0
Zone 1
Zone 2
Type of protection based on restricting the electrical energy within the equipment and interconnecting wiring exposed to explosive gas
atmospheres to a level below that which can cause ignition by sparking or heating.
60079-11
Oil Immersion
oZones
1 and 2
Type of protection in which the electrical apparatus or parts of the elec-trical apparatus are immersed in a protective liquid in such a way that an explosive atmosphere (gas or vapor), which may be above the protective
liquid or outside the enclosure, cannot be ignited.
60079-6
Sand Filling qZones
1 and 2
e of protection where electrical parts capable of igniting an explosive at-mosphere (gas or vapor) are fixed in position and completely surrounded by filling material (glass or quartz powder) to prevent the ignition of an
external explosive atmosphere.
60079-5
Encapsulation
ma
mb
mc
Zone 0
Zone 1
Zone 2
Type of protection in which the parts which can ignite an explosive atmosphere are enclosed in a resin sufficiently resistant to the environ-mental influences in such a way that this explosive atmosphere cannot
be ignited by either sparking or heating which may occur within the encapsulation.
60079-18
Pressurizedpx, py
pz
Zone 1
Zone 2
This type of protection prevents the surrounding atmosphere from entering an enclosure by maintaining a positive pressure within the unit.
Clean air or inert gas is used to maintain a higher pressure than the surrounding atmosphere.
60079-2
Special sZones
0, 1 and 2Type of protection developed for specific conditions, which have a new
type of protection that has not been standardized yet.
Set of specific protective measures applied to a piece
of equipment to prevent possible ignition of the
surrounding atmosphere.
10
EXPLOSIVE ATMOSPHERES
8. EQUIPMENT PROTECTION LEVEL - EPL
The equipment protection level [EPL] is a system
has been introduced to indicate the inherent risk of
ingnition the equipment, independent of the protection
type that is used.
The first letter [Uppercase] of the EPL, refers to the
local of equipment instalation, whilw the second letter
[lowercase] refers to the nivel protection.
Relation between Zones, EPL and Types of Protection
for Flammable Gases
Relation between Zones, EPL and Types of Protection
for Combustible Dusts
First Letter Place of Installation
M Mines
G Gas
D Combustible Dust
Second Letter Level of Protection
a Very high
b High
c Elevated
Zone EPL Type of Protection Marking EX
0 Ga
Intrinsic Safety ia
Encapsulation ma
Special Protecion a sa
1 Gb
Explosion Proof d
Increased Safety e
Intrinsic Safety ib
Encapsulation m, mb
Immersion Oil o
Pressurized p, px, py
Immersion Sand q
Special Protection b sb
2 Gc
Intrinsic Safety ic
Encapsulation mc
Non-incendive n, nA
Restricted Breathing nR
Energy LImiting nL
Sparking Equipment nC
Pressurized pz
Special Protection c sc
Zone EPL Type of Protection Marking EX
20 Da
Intrinsic Safety iD
Encapsulation mD
Dust ta
21 Db
Intrinsic Safety iD
Encapsulation mD
Dust tb
Pressurized pD
22 Dc
Intrinsic Safety iD
Encapsulation mD
Dust tc
Pressurized pD
11
EX
d
e
i
m
n
o
p
q
s
I MiningT1
T2
T3
T4
T5
T6
MMa
MbMining
II
II A
II B
II C
Gas or vapor
G
Ga
Gb
Gc
Gas or vapor
III
III A
III B
III C
Dust Fuel
D
Da
Db
Dc
Dust Fuel
9. MARKING OF EQUIPMENT FOR EXPLOSIVE ATMOSPHERES
Marking 2006-2010.
[INMETRO (Brazilian National Institute of
Metrology, Standardization and Industrial
Quality) Directive no. 83/2006].
Example of marking:
Explosion proof equipment for group IIC with
temperature class T6:
Ex d IIB T5 Gb
Explosive
Atmospheres
Type of
ProtectionGroup
Temperature
Class
Level
of protection
12
Firs
t C
hara
cteri
stic
Num
era
l:
Deg
rees
of
pro
tect
ion a
gain
st i
ng
ress
of
soli
d b
od
ies.
0 Not protected – IP 00 IP 01 IP 02
1
Protected against solid foreign objects of 50mm diameter and greater Sphere ø50mm
IP 10 IP 11 IP 12 IP 13
2
Protected against solid foreign objects of 12.5mm diameter and greater
Sphere ø12.5mm+ test finger
IP 20 IP 21 IP 22 IP 23
3
Protected against solid foreign objects of 2.5mm diameter and greater
Hard wire ø2.5mm
IP 30 IP 31 IP 32 IP 33 IP 34
4
Protected against solid foreign objects of 1mm diameter and greater
Hard wireø1mm
IP 40 IP 41 IP 42 IP 43 IP 44 IP 45 IP 46
5 Dust-protectedDust circulation
chamber
IP 54 IP 55 IP 56
6 Dust tightDust circulation
chamber
IP 65 IP 66 IP 67 IP 68
10. DEGREE OF PROTECTION
It is the level of protection defined by an enclosure
against access to hazardous parts, against ingress of
solid foreign objects and / or water.
The NBR IEC 60529 standard describes the classification
of degrees of protection provided by housing for
electrical equipment with rated voltages not exceeding
72.5 kV.
Designation to indicate the degree of protection consists
of the letters “IP” followed by two digits [characteristic
numerals] that indicate compliance with the conditions
in the table below:
• The first numeral indicates the degree of
protection provided by enclosures in relation to people
and the equipment inside, representing the level of
protection against ingress of solid foreign objects.
• The second numeral indicates protection of
equipment against harmful ingress of water.
Example application of the degree of protection. IP 6 6
Index
Protection againstdust penetration
Protection of against sea waves
DEGREE OF PROTECTION - IP
Standard NBR IEC 60529
Second characteristic numeral: Degrees of protection against ingress of water
0 1 2 3 4 5 6 7 8
Not protected
Protected against dripping
water (verti-cally falling
drops)
Protected against drip-ping water
[angle up to 15°]
Protected against spraying
water[angle up to
60°]
Protected against
splashing water
[angle up to360º]
Protected against
water jets
Protected against
ocean waves or powerful water jets
Protected against
immersion
Protected against
submersion
–
Dripping water Dripping water Superior spray360º rotary
sprayerNozzle ø6, 3mm flow 12.5 l/min
Nozzleø12,5 mm
flow 100 l/min1-meter deep
container
According to agreement between
customer and manufacturer
EXPLOSIVE ATMOSPHERES
CAEx
EXPLOSION PROOF CONDUIT OUTLETS AND JUNCTION BOXESEXPLOSION PROOF CONDUIT OUTLETS AND JUNCTION BOXES
14
CAEx
TECHNICAL FEATURES
• Box with Ex d protection [explosion proof] for use in
explosive atmospheres.
• Conduit outlets and junction boxes injected with
copper-free aluminum alloy are corrosion resistant.
• Threaded entry points from 1/2 “ to 2” NPT.
• Cover threaded to the body.
• Electrostatic powder coating finish in gray Munsell N6.5
polyester.
• O-ring type gasket seal installed on the cover.
• Stainless steel stud bolt to lock the cover.
• Screws, grounding connectors and non-rotating stainless
steel plate.
• Box can be used with terminals [junction box].
TO ORDER
• Example 1: Explosion proof Conduit Box in copper-free
aluminum, type C, thread 3/4” NPT.
By reference number: 56501/002
By item description: CAEx-2C
• Example 2: Explosion proof Junction Box in copper-free
aluminum, type T, thread 1” NPT, with 2.5mm² terminals.
By reference number:
56503/003 + 6x2.5mm² + 56702/001
By item description:
CAEx-3T + 6x2.5mm² + SUPORTE
Injected boxes present an excellent finishing.
EXPLOSION PROOF CONDUIT OUTLETS AND JUNCTION BOXES
PROTECTION: Ex d
ZONES: 1 and 2
GROUPS: IIC
TEMPERATURE: T6
EPL: Gb
DEGREE OF PROTECTION: IP 66
CERTIFICATES OF CONFORMITY:
CEPEL 11.2080 and CEPEL 12.2164
APPLICABLE STANDARDS:
ABNT NBR IEC 60079-0
ABNT NBR IEC 60079-1
ABNT NBR IEC 60529
15
CA
Ex
DIMENSIONS [mm]
REFERENCE DESCRIPTION D E F
56702/001Fixing support of the boxes CAEx of 1/2”, 3/4” and 1”
76 102 114
56702/002Fixing support of the boxes CAEx of 1.1/4”, 1.1/2” and 2”
120 160 176
FIXING SUPPORT OF THE BOX
DIMENSIONS [mm]
REFERENCE DESCRIPTION Ø THREAD Ø A B C WEIGHT [Kg] VOLUME [dm3] MODEL - TYPE
56500/001 CAEx-1E 1/2" NPT 88 66 100 0,40 0,22
E
56500/002 CAEx-2E 3/4" NPT 88 66 100 0,40 0,22
56500/003 CAEx-3E 1" NPT 88 73 100 0,45 0,25
56500/004 CAEx-4E 1.1/4" NPT 138 111 150 1,65 0,93
56500/005 CAEx-5E 1.1/2" NPT 138 111 150 1,65 0,93
56500/006 CAEx-6E 2" NPT 138 111 150 1,65 0,93
56501/001 CAEx-1C 1/2" NPT 88 66 100 0,40 0,22
C
56501/002 CAEx-2C 3/4" NPT 88 66 100 0,40 0,22
56501/003 CAEx-3C 1" NPT 88 73 100 0,45 0,25
56501/004 CAEx-4C 1.1/4" NPT 138 111 150 1,65 0,93
56501/005 CAEx-5C 1.1/2" NPT 138 111 150 1,65 0,93
56501/006 CAEx-6C 2" NPT 138 111 150 1,65 0,93
56502/001 CAEx-1L 1/2" NPT 88 66 100 0,40 0,22
L
56502/002 CAEx-2L 3/4" NPT 88 66 100 0,40 0,22
56502/003 CAEx-3L 1" NPT 88 73 100 0,45 0,25
56502/004 CAEx-4L 1.1/4" NPT 138 111 150 1,65 0,93
56502/005 CAEx-5L 1.1/2" NPT 138 111 150 1,65 0,93
56502/006 CAEx-6L 2" NPT 138 111 150 1,65 0,93
56503/001 CAEx-1T 1/2" NPT 88 66 100 0,40 0,22
T
56503/002 CAEx-2T 3/4" NPT 88 66 100 0,40 0,22
56503/003 CAEx-3T 1" NPT 88 73 100 0,45 0,25
56503/004 CAEx-4T 1.1/4" NPT 138 111 150 1,65 0,93
56503/005 CAEx-5T 1.1/2" NPT 138 111 150 1,65 0,93
56503/006 CAEx-6T 2" NPT 138 111 150 1,65 0,93
56504/001 CAEx-1X 1/2" NPT 88 66 100 0,40 0,22
X
56504/002 CAEx-2X 3/4" NPT 88 66 100 0,40 0,22
56504/003 CAEx-3X 1" NPT 88 73 100 0,45 0,25
56504/004 CAEx-4X 1.1/4" NPT 138 111 150 1,65 0,93
56504/005 CAEx-5X 1.1/2" NPT 138 111 150 1,65 0,93
56504/006 CAEx-6X 2" NPT 138 111 150 1,65 0,93
Superior ViewInferior View
Lateral View
CAEx Boxes
TECHNICAL FEATURES
16
CAEx
BORNES: SECTION AND QUANTITY [MAXIMUM]
TYPE BOX GAUGE VOLUME [cm3] 1,5 mm2 2,5 mm2 4 mm2 6 mm2 10 mm2 16 mm2 25 mm2 35 mm2
1/2”200
6 6 4 - - - - -3/4”
1” 230
1 1/4”
1150 9 9 9 6 4 4 4 31 1/2”
2”
MAXIMUM CURRENT BY TERMINAL [A] 10 12,5 20 24 30 48 75 105
MAXIMUM DENSITY OF CURRENT BY TERMINAL [A/MM²]
6,6 5 5 4 3 3 3 3
RATED VOLTAGE [V] 750
Superior View
Cut Lateral View
JUNCTION BOXES [WITH TERMINALS]
TABLE A
CBEx
EXPLOSION PROOF CONDUIT OUTLETS AND JUNCTION BOXESEXPLOSION PROOF CONDUIT OUTLETS AND JUNCTION BOXES
18
CBEx
TECHNICAL FEATURES
• Box with Ex d protection [explosion proof] for use in
explosive atmospheres.
• Conduit outlets and junction boxes made of copper-free
aluminum alloy are corrosion resistant.
• Threaded entry points from 1/2 “ to 4” NPT. Position
of mounting holes made according to customer
specifications.
• Cover threaded to the body.
• Electrostatic powder coating finish in grey Munsell N6.5
polyester.
• Type O-ring gasket sealing installed on the cover.
• Inner plate made of aluminum alloy or galvanized steel.
• Stainless steel stud lug to lock the cover.
• Ground screws and non-rotating stainless steel plate.
• Box can be used with terminals [junction box].
EXPLOSION PROOF CONDUIT OUTLETS AND JUNCTION BOXES
TO ORDER
• Example 1: Explosion proof conduit Box in copper-free
aluminum, CBEx-1model, with three 3/4” NPT threaded
entry points.
By reference number: 56510/000 + 3x3/4” NPT
By item description: CBEx-1 + 3x3/4” NPT
• Example 2: Explosion proof junction box in copper-free
aluminum, CBEx-3 model, with four 1” NPT threaded
entry points and eight terminals 10mm².
By reference number:
56512/000 + 4x1” NPT + 8x10mm2
By item description:
CBEx-3 + 4x1” NPT + 8x10mm²
PROTECTION: Ex d
ZONES: 1 and 2
GROUPS: IIC
TEMPERATURE: T6
EPL: Gb
DEGREE OF PROTECTION: IP 66
CERTIFICATES OF CONFORMITY:
CEPEL 12.2089 and CEPEL 12.2184
APPLICABLE STANDARDS:
ABNT NBR IEC 60079-0
ABNT NBR IEC 60079-1
ABNT NBR IEC 60529
19
CB
Ex
DIMENSIONS
REFERENCE BOX MODEL A B C D ø E F G H IVOLUME
[dm3]WEIGHT
[kg]
56510/000 CBEx-1 161 161 184 136 8 133 132 132 103 1,72 3,25
56511/000 CBEx-2 184 184 204 158 8 142 152 152 112 2,46 4,65
56512/000 CBEx-3 239 239 265 202 10 173 200 200 134 5,35 9,30
56513/000 CBEx-4 309 309 338 275 12 224 267 267 183 13,25 17,40
Superior View
BOXES WITH ENTRIES THREADED
Cut Lateral View
Cut Lateral View
BOX MODEL
USEFUL SURFACE MAXIMUM NUMBER OF HOLES ALLOWED ON EACH SIDE
F1 F2 cm2 1/2” 3/4” 1” 1.1/4” 1.1/2” 2” 2.1/2” 3” 4”SCREW / THREAD,
COVER AND BODY
CBEx-1 118 70 83 4 3 2 1 - - - - - M 130 X 2
CBEx-2 135 74 100 5 3 2 1 1 - - - - M 150 X 2
CBEx-3 185 90 167 9 6 3 2 1 1 - - - M 200 X 2
CBEx-4 250 132 330 18 11 7 4 3 2 1 1 1 M 270 X 3
TECHNICAL FEATURES
Note:
MINIMUM DISTANCE BETWEEN CENTERS “X”
SIZES 1/2” 3/4” 1” 1.1/4” 1.1/2” 2” 2.1/2” 3” 4”
1/2” 47 53 63 72 75 89 96 106 123
3/4” 53 57 69 77 80 94 100 110 126
1” 63 69 74 83 86 99 106 117 134
1.1/4” 72 77 83 92 95 106 113 126 140
1.1/2” 75 80 86 95 103 114 121 134 146
2” 89 94 99 106 114 125 132 145 157
2.1/2” 96 100 106 113 121 132 148 156 172
3” 106 110 117 126 134 145 156 174 189
4” 123 126 134 140 146 157 172 189 214
F2
F1
x x
x
20
CBEx
BOX MODELDIMENSIONS
J L M
CBEx-1 120 120 106
CBEx-2 141 141 126
CBEx-3 188 188 175
CBEx-4 256 256 248
Superior View
TERMINAL SECTION AND QUANTITY [MAXIMUM]
BOX MODELVOLUME
[dm3]1,5 mm2 2,5 mm2 4 mm2 6 mm2 10 mm2 16 mm2 25 mm2 35 mm2 70 mm2
CBEx-1 1,80 12 12 12 10 8 5 - - -
CBEx-2 2,59 20 20 16 12 10 8 4 4 4
CBEx-3 5,47 28 28 24 18 14 12 8 8 6
CBEx-4 13,74 45 45 36 28 22 18 12 12 9
MAXIMUM CURRENT BY TERMINAL [A] 10 12,5 20 24 30 48 75 105 175
MAXIMUM DENSITY OF CURRENT BY TERMINAL [A/MM²]
6,6 5 5 4 3 3 3 3 2,5
RATED VOLTAGE [V] 750 V
JUNCTION BOX [WITH TERMINALS]
Note:
TABLE A
CCEx
EXPLOSION PROOF CONDUIT OUTLETS BOXES AND PANELSEXPLOSION PROOF CONDUIT OUTLETS BOXES AND PANELS
CCEx
22
EXPLOSION PROOF CONDUIT OUTLETS BOXES AND PANELS
TECHNICAL FEATURES
• Box with Ex d protection [explosion proof] for use in
explosive atmospheres.
• Panels made of copper-free aluminum alloy are corrosion
resistant.
• Threaded entries from 1/2“ to 2” NPT. Position
of mounting holes made according to customer
specifications.
• Cover secured to the body with stainless steel screws
with hexagon socket.
• Electrostatic powder coating finish in grey Munsell N6.5
polyester.
• Type O-ring gasket sealing installed on the box.
• Inner plate made of aluminum or galvanized steel.
• Stainless steel screws, ground connections and hinges.
• Lugs for wall mounting.
• Possibility to provide panels with analog / digital
instruments, PLCs (Programmable Logic Controller),
Fuses, Relays, Contactors, Switches, Timers, Capacitors,
Transformers, Terminals / Connectors, Circuit Breakers,
Switch-Disconnectors, Frequency Inverters, Soft-Starter,
Buses, Pilot and control stations, among others, according
to customer’s design.
TO ORDER
1. Conduit Boxes: Box model + quantities, gauges and
positions of the entries threaded.
Example:
Model: CCEx-3B
Entries: 2 entries 3/4” NPT position BH
2. Panels send or request the project to Tramontina.
Steel stainless screw
Cover
Conexion grounding cover
Conexion grouding interior
Terminal tread
Hinge
Plate to fix the components
Oring (sealing)
Interstice (GAP)
Body box
Conexiongrounding external
Fixing support
PROTECTION: Ex d
ZONES: 1 and 2
GROUPS: IIB
TEMPERATURE: T6 or T5
EPL: Gb
DEGREE OF PROTECTION: IP 66
APPLICABLE STANDARDS:
ABNT NBR IEC 60079-0
ABNT NBR IEC 60079-1
ABNT NBR IEC 60529
23
CC
Ex
EXTERNALDIMENSIONS [mm]
INTERNAL DIMENSIONS [mm]
SUPPORTFIXATION [mm]
PLATE [mm]
MODEL A B C D E F G H I J L WEIGHT [Kg]VOLUME
[dm3]
CCEx-1C 200 200 150 135 135 115 130 190 8 125 125 5,0 2,0
CCEx-2C 300 300 170 230 230 135 215 277 8 220 220 11,4 7,0
CCEx-3C 400 400 200 325 325 160 305 377 8 310 310 22,5 17,0
CCEx-1 310 210 160 240 140 125 225 190 8 230 130 8,0 4,3
CCEx-2B350 250
200280 180
165265 227 8 270 170
11,8 8,4
CCEx-2 250 215 13,5 11,0
CCEx-3B450 350
200375 275
160355 327 8 360 260
22,0 16,4
CCEx-3 250 210 25,0 21,6
CCEx-4B550 350
200475 275
155455 327 8 460 260
27,0 21,0
CCEx-4 250 205 30,5 27,2
CCEx-5B650 450
250565 365
200545 428 10 550 350
54,0 41,0
CCEx-5 300 250 58,5 52,0
CCEx-6B700 500
250610 410
190595 478 10 580 380
70,0 50,0
CCEx-6 300 240 77,0 62,0
CCEx-7B850 600
300740 490
225719 575 10 720 460
135,0 85,5
CCEx-7 350 275 145,0 97,0
CCEx-8B1100 600
300990 490
225979 575 10 900 470
172,0 115,0
CCEx-8 350 275 185,0 130,0
Superior View Box
Cut Lateral view box and Cover
Plate
Inferior View Box
TECHNICAL FEATURES
CCEx
24
LARGER SIDE
LOWER SIDE
MAXIMUM QUANTITY OF ENTRIES OF LARGER SIDEAREA FOR DRILLING
MODEL 1/2” 3/4” 1” 1.1/4” 1.1/2” 2” 2.1/2” 3” 4” a c
CCEx-1C 5 3 2 1 1 - - - - 115 80
CCEx-2C 8 7 3 2 2 1 1 - - 200 100
CCEx-3C 18 10 8 3 3 2 1 1 - 300 125
CCEx-1 10 7 3 2 2 1 1 - - 210 100
CCEx-2B 15 8 6 4 3 2 1 1 - 250 135
CCEx-2 20 12 9 6 5 3 2 1 - 250 185
CCEx-3B 21 12 10 6 3 3 2 1 - 340 135
CCEx-3 28 18 10 8 6 4 2 1 1 340 180
CCEx-4B 27 16 12 8 4 4 2 1 1 440 130
CCEx-4 36 24 18 10 8 5 3 2 1 440 180
CCEx-5B 44 27 14 12 10 4 4 2 1 530 170
CCEx-5 55 36 21 12 10 8 5 3 2 530 220
CCEx-6B 48 30 16 12 10 5 4 2 1 570 160
CCEx-6 60 40 24 12 12 8 5 3 2 570 210
CCEx-7B 60 36 30 16 14 9 5 4 2 690 190
CCEx-7 75 48 27 23 14 11 8 4 3 690 240
CCEx-8B 80 48 39 20 18 12 6 5 3 920 190
CCEx-8 100 64 39 30 18 14 10 5 4 920 240
MAXIMUM QUANTITY OF ENTRIES OF LOWER SIDEAREA FOR DRILLING
MODEL 1/2” 3/4” 1” 1.1/4” 1.1/2” 2” 2.1/2” 3” 4” b c
CCEx-1C 5 3 2 1 1 - - - - 115 80
CCEx-2C 8 7 3 2 2 1 1 - - 200 100
CCEx-3C 18 10 8 3 3 2 1 1 - 300 125
CCEx-1 4 4 2 1 1 - - - - 110 100
CCEx-2B 9 6 4 3 2 1 1 - - 150 135
CCEx-2 12 9 6 4 3 2 1 - - 150 185
CCEx-3B 15 8 6 4 2 2 1 1 - 240 135
CCEx-3 20 12 9 6 4 3 2 1 - 240 180
CCEx-4B 15 8 6 4 3 2 1 1 - 250 130
CCEx-4 20 12 9 6 5 3 2 1 - 250 180
CCEx-5B 28 18 10 8 5 3 2 1 1 330 170
CCEx-5 35 24 15 8 6 5 3 2 1 330 220
CCEx-6B 32 21 10 8 6 3 2 2 1 370 160
CCEx-6 40 28 15 8 8 5 3 2 1 370 210
CCEx-7B 36 24 18 10 8 5 3 2 1 440 190
CCEx-7 45 32 18 15 8 7 5 3 2 440 240
CCEx-8B 36 24 18 10 8 5 3 2 1 440 190
CCEx-8 45 32 18 15 8 7 5 3 2 440 240
BOXES WITH THREADED ENTRIES
Larger Side View
Smaller Side View
Note: for other configurations, please contact TRAMONTINA.
Note: for other configurations, please contact TRAMONTINA.
25
CC
Ex
MINIMUM DISTANCE BETWEEN CENTERS “X”
GAUGE 1/2” 3/4” 1” 1.1/4” 1.1/2” 2” 2.1/2” 3” 4”
1/2” 47 53 63 72 75 89 96 106 123
3/4” 53 57 69 77 80 94 100 110 126
1” 63 69 74 83 86 99 106 117 134
1.1/4” 72 77 83 92 95 106 113 126 140
1.1/2” 75 80 86 95 103 114 121 134 146
2” 89 94 99 106 114 125 132 145 157
2.1/2” 96 100 106 113 121 132 148 156 172
3” 106 110 117 126 134 145 156 174 189
4” 123 126 134 140 146 157 172 189 214
MAXIMUM QUANTITY OF HOLES
AREA FORDRILLING [mm]
MODEL a b
CCEx-1C 4 115 115
CCEx-2C 9 200 200
CCEx-3C 16 300 300
CCEx-1 8 210 110
CCEx-2B12 250 150
CCEx-2
CCEx-3B20 340 240
CCEx-3
CCEx-4B24 440 250
CCEx-4
CCEx-5B40 530 330
CCEx-5
CCEx-6B54 570 370
CCEx-6
CCEx-7B70 690 440
CCEx-7
CCEx-8B80 920 440
CCEx-8
COVERS WITH THREADED ENTRIES
Top View
Positions of threaded entries
CCEx
26
TEMPERED GLASS COVERS
SQUARE /RECTANGULAR DISPLAY SIZE
ROUND DISPLAY
SIZE
MODEL A x B [mm]MAXIMUMQUANTITY
Ø [mm]
CCEx-1C 96 x 96 - -CCEx-2C 160 x 160 1 90
CCEx-3C 220 x 2202 901 140
CCEx-1 150 x 80 - -CCEx-2BCCEx-2 200 x 150 1 90
CCEx-3BCCEx-3 200 x 150 2 90
CCEx-4BCCEx-4 300 x 200
2 901 140
CCEx-5BCCEx-5 300 x 200
2 901 140
CCEx-6BCCEx-6 300 x 200
2 901 1401 180
CCEx-7BCCEx-7 300 x 200
3 902 1402 180
CCEx-8BCCEx-8 300 x 200
3 902 1402 180
Cover with square display / Rectangular
Cover with round display
Note: for other configurations, please contact TRAMONTINA.
27
CC
Ex
BOXES [WITH TERMINALS]
MODEL
TERMINAL2,5 mm2
TERMINAL4 mm2
TERMINAL6 mm2
TERMINAL10 mm2
TERMINAL16 mm2
TERMINAL25 mm2
TREADTERMINAL IN EACHTREAD
TREADTERMINAL IN EACHTREAD
TREADTERMINAL IN EACHTREAD
TREADTERMINAL IN EACHTREAD
TREADTERMINAL IN EACHTREAD
TREADTERMINAL IN EACHTREAD
CCEx-1C 1 12 1 12 1 10 1 8 1 8 1 6CCEx-2C 1 22 1 22 1 18 1 12 1 12 1 8CCEx-3C 2 30 2 30 1 24 1 26 1 26 1 12CCEx-1 1 28 1 26 1 21 1 17 1 14 1 12CCEx-2B 2 38 2 35 2 28 2 23 2 21 1 18CCEx-2 2 38 2 35 2 28 2 23 2 21 1 18CCEx-3B 3 48 3 38 3 30 3 29 2 25 2 21CCEx-3 3 48 3 38 3 30 3 29 2 25 2 21CCEx-4B 3 70 3 65 3 50 3 35 3 25 2 25CCEx-4 3 70 3 65 3 50 3 35 3 25 2 25CCEx-5B 3 80 3 70 3 60 3 50 3 40 2 30CCEx-5 3 80 3 70 3 60 3 50 3 40 2 30CCEx-6B 3 90 3 80 3 70 3 54 3 42 2 34CCEx-6 3 90 3 80 3 70 3 54 3 42 2 34CCEx-7B 4 120 4 100 4 80 4 60 4 50 3 40CCEx-7 4 120 4 100 4 80 4 60 4 50 3 40CCEx-8B 4 150 4 120 4 120 4 85 4 70 3 65CCEx-8 4 150 4 120 4 120 4 85 4 70 3 65
12.5 20 24 30 48 75
5 5 4 3 3 3
750 750 750 750 750 750
MODELO
TERMINAL35 mm2
TERMINAL70 mm2
TERMINAL95 mm2
TERMINAL120 mm2
TERMINAL185 mm2
TERMINAL240 mm2
TREADTERMINAL IN EACH TREAD
TREADTERMINAL IN EACH TREAD
TREADTERMINAL IN EACH TREAD
TREADTERMINAL IN EACH TREAD
TREADTERMINAL IN EACH TREAD
TREADTERMINAL IN EACH TREAD
CCEx-1C - - 1 - 1 - 1 - 1 - 1 -
CCEx-2C 1 6 1 - 1 - 1 - 1 - 1 -
CCEx-3C 1 8 1 4 1 4 1 4 1 - 1 -
CCEx-1 1 10 1 3 1 10 1 - 1 - 1 -
CCEx-2B 1 14 1 6 1 14 1 4 1 3 1 3
CCEx-2 1 14 1 6 1 14 1 4 1 3 1 3
CCEx-3B 2 18 1 13 1 18 1 6 1 6 1 6
CCEx-3 2 18 1 13 1 18 1 6 1 6 1 6
CCEx-4B 2 20 1 20 1 20 1 10 1 8 1 8
CCEx-4 2 20 1 20 1 20 1 10 1 8 1 8
CCEx-5B 2 28 1 28 1 22 1 10 1 10 1 8
CCEx-5 2 28 1 28 1 22 1 10 1 10 1 8
CCEx-6B 2 30 1 30 1 25 1 12 1 12 1 9
CCEx-6 2 30 1 30 1 25 1 12 1 12 1 9
CCEx-7B 3 35 1 35 1 30 1 15 1 15 1 10
CCEx-7 3 35 1 35 1 30 1 15 1 15 1 10
CCEx-8B 3 55 1 55 1 42 1 24 1 20 1 12
CCEx-8 3 55 1 55 1 42 1 24 1 20 1 12
105 175 190 240 315 400
3 2.5 2.5 2 2 1,65
750 750 750 750 750 750
Note:
CCEx
28
Cut Superior View Cut Lateral View
CCEx PANELS
CPEx
EXPLOSION PROOF CONTROL STATIONS EXPLOSION PROOF CONTROL STATIONS
CPEx
30
TECHNICAL FEATURES
• Box with Ex d protection [explosion proof] for use in
explosive atmospheres.
• Control stations injected with copper-free aluminum alloy
are corrosion resistant.
• Threaded entries from 3/4“ or 1” NPT.
• Cover secured to the body with stainless steel screws with
hexagon socket.
• Electrostatic powder coating finish in grey Munsell N6.5
polyester.
• Type O-ring gasket sealing installed on the cover.
• Ground screws and non-rotating stainless steel plate.
• 3 options: simple, double and triple boxes.
• Custom built pilot and control stations.
EXPLOSION PROOF CONTROL STATIONS
Injected boxes feature an excellent finish.
PROTECTION: Ex d
ZONES: 1 and 2
GROUPS: IIB
TEMPERATURE: T6
EPL: Gb
DEGREE OF PROTECTION: IP 66
CERTIFICATES OF CONFORMITY: CEPEL 12.2143
APPLICABLE STANDARDS:
ABNT NBR IEC 60079-0
ABNT NBR IEC 60079-1
ABNT NBR IEC 60529
31
CPEx
CPEx-1
CPEx-2
CPEx-3
Superior View
Superior View
Superior View
Inferior View
Inferior View
Inferior View
Lateral View
Lateral View
Lateral View
3
3
3
Box CPEX-1
Box CPEx-2
Box CPEx-3
TECHNICAL FEATURES
CPEx
32
Box reference number
Example 1:
Example 2:
Note:
Control station reference number
+
MODEL HUB SIZE REF.
CPEx-1
2 x 3/4”NPT CPEx11
2 x 1”NPT CPEx12
CPEx-2
2 x 3/4”NPT CPEx21
2 x 1”NPT CPEx22
CPEx-3
2 x 3/4”NPT CPEx31
2 x 1”NPT CPEx32
PARTS REF. FINAL REF.
CPEx-2 box with two 3/4” NPT entries CPEx21
CPEx21 + PSVD10 + PSVM01Green push button NA
PSVM01
PARTS REF. FINAL REF.
CPEx-3 box with two 1” NPT entries CPEx32
CPEx32 + ILVM22 + PSVD10 + PEG11ILVM22
Green push button NA
PEG11
MODEL REF.
PS ...
Push Button - PEP ...
Push Button - PEG ...
Push Button - PEC ...
with ledIL ...
TO ORDER
EXPLOSION PROOF PILOT AND CONTROL STATIONS, PLUGS, THREAD ADAPTORS AND BREATHER DRAIN
FOR EXPLOSIVE ATMOSPHEREFOR EXPLOSIVE ATMOSPHERE
Acessories and Conexions
34
ACEx
TECHNICAL FEATURES
• Explosion proof pilot and control stations Ex d for use in
explosive atmospheres.
• Body and axle manufactured in steel stainless.
Handspilce manufactured in aluminum alloy.
• Possibility to supply the drives with thread M22 or M30.
EXPLOSION PROOF PILOT AND CONTROL STATIONS
ACEx
PROTECTION: Ex d
ZONES: 1 and 2
GROUPS: IIC
EPL: Gb
DEGREE OF PROTECTION: IP 66
CERTIFICATES OF CONFORMITY: CEPEL 12.2142
APPLICABLE STANDARDS:
ABNT NBR IEC 60079-0
ABNT NBR IEC 60079-1
ABNT NBR IEC 60529
35
AC
Ex
PS - EXPLOSION PROOF PUSH BUTTON
Ex d IIC Gb IP66
Thread M22x1.5or
Thread M30x1.5
Exploded View
COLOR REF.
Yellow AM
Blue AZ
White
Green
VM
CONTACT SCHEME REF.
1NA
3
4
10
1NF
1
2
01
3
4
1
2
11
2NA
3
4
3
4
20
2NF
1
2
1
2
02
PS
Example:
PARTS REF. FINAL REF.
Single Pushbutton PS
PSVM01VM
01
+
TECHNICAL FEATURES
TO ORDER
Push Button Reference + Cover Color Reference + Contact Block Reference
+
TECHNICAL FEATURES
Use: Ex d.
Can be ordered in stainless steel 316L.
2 2
36
ACExPE - EXPLOSION PROOF EMERGENCY PUSH BUTTONS
PEP
push button
PEG
button
CONTACT SCHEME REF.
1NA
3
4
10
1NF
1
2
01
3
4
1
2
11
2NA
3
4
3
4
20
2NF
1
2
1
2
02
PEPPEGPEC
Example:
PARTS REF. FINAL REF.
PEGPEG11
11
PEC
Push Button
Thread M22x1.5or
Thread M30x1.5
Exploded View
Ex d IIC Gb IP66
TO ORDER
Push button Reference + Contact Block Reference
+
TECHINICAL FEATURES
Use: Ex d.
Suitable for Boxes CCEx and CPEx Tramontina Ex.
Can be ordered in stainless steel 316L.
2 2
37
AC
Ex
IL - EXPLOSION PROOF PILOT LIGHT [LED]
Ex d IIC Gb IP66
IL
Exploded View
VOLTAGE REF.
12
24
48
11
22
Example:
PARTS REF. FINAL REF.
IL
ILVD22Lens Color Green
22
COLOR SCHEME REF.
Yellow
X1
X2
AM
Blue AZ
White
Green
VM
TO ORDER
Pushbutton Reference + Lens Color Reference + Contact Block Reference
+ +
TECHINICAL FEATURES
Use:
Can be ordered in stainless steel 316L.
2 2
Thread M22x1.5or
Thread M30x1.5
38
TECHINICAL FEATURES
Use:
Can be ordered in stainless steel 316L.
ACExAG - EXPLOSION PROOF CIRCUIT BREAKER ACTUATOR
AGGAGMAGP
XXX [3 digits]
Example 1: Example 2:
PARTS REF. FINAL REF.
AGMAGM050
050
PARTS REF. FINAL REF.
AGPAGP220
220
AGGEx d IIC Gb IP66
Rosca M22x1,5
Vista Explodida
AGMEx d IIC Gb IP66
Rosca M22x1,5
Vista Explodida
AGPEx d IIC Gb IP66
Rosca M22x1,5
Vista Explodida
[3 digits with at least 30 mm]
TO ORDER
Device Reference + “L” Length Reference
+
39
BU
Ex
TECHINICAL FEATURES
• Plugs with Ex d protection [explosion proof] for use in
explosive atmospheres.
• Sizes of 1/2” to 4”, NPT thread.
• Used to close unused threaded entries of explosion proof
enclosures and boxes.
• Made of copper-free aluminum alloy.
• Can be ordered in naval brass, galvanized steel or
stainless steel 304.
EXPLOSION PROOF PLUGS
TO ORDER
• Example 1: Explosion proof plug made of copper-free
aluminum; thread 3/4”NPT.
By reference number: 56700/002
• Example 2: Explosion proof plug made of stainless steel
304, thread 1”NPT.
By reference number: 56700/013
• Example 3: Explosion proof plug made of naval brass,
thread 2”NPT.
By reference number: 56700/026
• Example 4: Explosion proof plug made of galvanized
steel, thread 3”NPT.
By reference number: 56700/038
BUEx
PROTECTION: Ex d
ZONES: 1 and 2
GROUPS: IIC
EPL: Gb
DEGREE OF PROTECTION: IP 66
CERTIFICATES OF CONFORMITY: CEPEL 11.2081X
APPLICABLE STANDARDS:
ABNT NBR IEC 60079-0
ABNT NBR IEC 60079-1
ABNT NBR IEC 60529
40
BUExNPT PLUGS
Frontal View
Corte Vista Lateral
REF. MODEL Ø THREAD A [mm] B [mm] RAW MATERIAL
56700/001 BUEx-1 1/2”NPT 12 17,5
56700/002 BUEx-2 3/4”NPT 12 17,5
56700/003 BUEx-3 1”NPT 12 18,0
56700/004 BUEx-4 1.1/4”NPT 12 18,5
56700/005 BUEx-5 1.1/2”NPT 12 18,5
56700/006 BUEx-6 2”NPT 24 19,0
56700/007 BUEx-7 2.1/2”NPT 24 28,5
56700/008 BUEx-8 3”NPT 24 30,6
56700/009 BUEx-10 4”NPT 24 32,6
56700/011 BUEx-1 1/2”NPT 12 17,5
Steel Stainless 304
56700/012 BUEx-2 3/4”NPT 12 17,5
56700/013 BUEx-3 1”NPT 12 18,0
56700/014 BUEx-4 1.1/4”NPT 12 18,5
56700/015 BUEx-5 1.1/2”NPT 12 18,5
56700/016 BUEx-6 2”NPT 24 19,0
56700/017 BUEx-7 2.1/2”NPT 24 28,5
56700/018 BUEx-8 3”NPT 24 30,6
56700/019 BUEx-10 4”NPT 24 32,6
56700/021 BUEx-1 1/2”NPT 12 17,5
56700/022 BUEx-2 3/4”NPT 12 17,5
56700/023 BUEx-3 1”NPT 12 18,0
56700/024 BUEx-4 1.1/4”NPT 12 18,5
56700/025 BUEx-5 1.1/2”NPT 12 18,5
56700/026 BUEx-6 2”NPT 24 19,0
56700/027 BUEx-7 2.1/2”NPT 24 28,5
56700/028 BUEx-8 3”NPT 24 30,6
56700/029 BUEx-10 4”NPT 24 32,6
56700/031 BUEx-1 1/2”NPT 12 17,5
56700/032 BUEx-2 3/4”NPT 12 17,5
56700/033 BUEx-3 1”NPT 12 18,0
56700/034 BUEx-4 1.1/4”NPT 12 18,5
56700/035 BUEx-5 1.1/2”NPT 12 18,5
56700/036 BUEx-6 2”NPT 24 19,0
56700/037 BUEx-7 2.1/2”NPT 24 28,5
56700/038 BUEx-8 3”NPT 24 30,6
56700/039 BUEx-10 4”NPT 24 32,6
Lateral View
41
AD
Ex
EXPLOSION PROOF THREAD ADAPTORS WITH INCREASED SAFETY
ADEx
TECHINICAL FEATURES
• Thread adapters with Ex d protection [explosion proof],
Ex e [increased safety] and Ex tb [combustible dust].
• Made of nickel-plated brass. Can be ordered in brass,
aluminum alloy, stainless steel and galvanized steel.
• Models of adapters with NPT threads of ½” to 3” and
metric from M16 to M85 [contact Tramontina for options
and availability].
• Adapters used to join electrical ducts and / or housings
of different diameters.
Reduction glove
Reduction bushing
Niple
PROTECTION: Ex d; Ex e; Ex tb
ZONES: 1 and 2; 21 and 22
GROUPS: IIC; IIIC
EPL: Gb; Db
DEGREE OF PROTECTION: IP 65
CERTIFICATES OF CONFORMITY: DNV 12.0066
APPLICABLE STANDARDS:
ABNT NBR IEC 60079-0
ABNT NBR IEC 60079-1
ABNT NBR IEC 60079-7
ABNT NBR IEC 60079-31
42
DREx
BREATHER DRAIN WITH INCREASED SAFETY
TECHINICAL FEATURES
• Breather Drain with Ex d protection [explosion proof]
and Ex tb [combustible dust].
• Made of nickel-plated brass. Can be ordered in brass and
stainless steel.
• NPT Threads of 3/8” and 1/2” and metric threads of M16
and M20.
• Used in housings installed in environments with high
humidity or large temperature variations and which have
condensation problems.
PROTECTION: Ex e; Ex tb
ZONES: 1 and 2; 21 and 22
GROUPS: IIC; IIIC
EPL: Gb; Db
DEGREE OF PROTECTION: IP 65
CERTIFICATES OF CONFORMITY: DNV 12.0067 U
APPLICABLE STANDARDS:
ABNT NBR IEC 60079-0
ABNT NBR IEC 60079-7
ABNT NBR IEC 60079-31
TRAMONTINA ELETRIK S.A. Rodovia RSC 470, Km 230 - CEP 95185-000 - Carlos Barbosa /RS - Brasil - Phone: + 55 [54] 3461.8200 - [email protected]
www.tramontina.com