Congratulations on your purchase of the Lionel TrainMaster SC-2 Switch and
Accessory Controller! With this device you can experience the benefits of TrainMaster Command Control when operating your switches and accessories with your CAB-1 Remote Controller.
The SC-2 listens for and responds to switch (SW), route (RTE), and accessory
(ACC) commands from your CAB-1 Remote Controller and Command Base.
You may choose to operate your SC-2 in its standard configuration or in either of the two alternate modes. The standard configuration controls four switches and four accessories. When operating in the alternate modes, you may control up to six switches, or twelve acces-sory actions.
A CAB-1 Remote Control (6-12868) and a Command Base (6-12911) are required to operate the SC-2. Find them both at your authorized Lionel dealer.
Note!
The following Lionel marks may be used throughout this instruction manual and are protected under law. All rights reserved.
Lionel®, TrainMaster®, Odyssey®, RailSounds™, CrewTalk™, TowerCom™, DynaChuff™, StationSounds™, Pullmor®, ElectroCoupler™, Magne-Traction®, CAB-1 Remote Controller®, PowerMaster®, Lionel ZW®, ZW®, PowerHouse®, TMCC™, Lionelville™
�
Table of contents
Installing the SC-2 on your railroadSC-2 basics 4-5Powering your SC-2 6-7Connecting Lionel switches to the SC-2 8-9Modifying O-27 switches for use with the SC-2 10Connecting hi-rail switch motors to SC-2 11-12
Operating switches with your SC-2Programming the SC-2 switch numbers 13Controlling switches with CAB-1 14Creating routes around your railroad 15-16Activating routes 17Modifying routes 17Clearing Routes 18
Operating accessories with your SC-2Connecting accessories to the SC-2 19Programming SC-2 accessory ID#’s 20Controlling accessories with your CAB-1 21
Advancd opertionsOperating switches only 22Operating accessories only 23Operating output terminal connections 24
TroubleshootingReplacing the fuse 25Answers to questions 26-27
Accessory connectionsRotary beacon/Control tower/Floodlight tower/Icing station 28Water tower 28Lumber mill/Sawmill 29Switch tower 29Diesel fueling station 30Oil derrick 30Lumber loader 31Log loader 31Coal tower 32Whistle shack 32Freight station 33Aircraft pylon 33Oil drum loader 34Bascule bridge 34Uncoupling track 35Lionel Service 36
�
Each SC-2 can control switches and acces-sories through commands from the
CAB-1 Remote Controller and Command Base. All SC-2 outputs are rated for 15 amps and can control most switches and accessories directly. Use the sheet of labels (included) to identify the SC-2 ID#’s on your switches and accessories.
The SC-2 has a built-in antenna to receive signals from the TrainMaster Command Base. Place the SC-2 anywhere near track connected to a Command Base, and it will receive its commands.
There are three sets of terminals on the SC-2. Within each terminal block are an upper and a lower row of three set screws. The center screw of each group is for the transformer Common/Ground/U or Power/A terminal, depending on the application. The left and right set screws are wired to a switch or accessory to activate it. When a terminal is programmed to control a switch, the opera-tion will be momentary. If the terminal is set to operate an accessory then you may select AUX1 for a momentary operation or AUX2 to
toggle the accessory on or off. Refer to Figure 1 on page 5 to identify the arrange-ment of the terminals.
The SC-2 is designed for three operating modes:
1. Control four switches through the left and center terminal blocks. Control two momentary and two on/off accessory func-tions through the right terminal block.
2. Control six switches using all three terminal blocks.
3. Control six momentary and six on/off accessory functions using all three terminal blocks.
To connect a switch or accessory to the SC-2, use a screwdriver to loosen the set screws on the terminal, then insert a stripped wire in the opening directly beneath the set screw and tighten the screw. Refer to Figure 2.
You do not need to remove the screws.
SC-2 basics
Installing the SC-2 on your railroad
Note! The labels printed on the SC-2 near the terminals refer to standard operation only. If you program the SC-2 to operate only switches or only accessories, the action of the terminals will change and will not correspond to the arrangement printed on the circuit board.
Note!
5
SC-2 basics (continued)
Installing the SC-2 on your railroad
ACC3 ACC4
ACC1 ACC2
SW 3
SW 1
Auxiliary or track power7-20V AC
SW 2 SW 4
Acc 1
Acc 2
SC-2
Toggle On/OffMomentary
Figure 1. SC-2 connections
Figure 2. Wire connections
�
Powering your SC-2
Installing the SC-2 on your railroad
There are three ways to power the SC-2. The type of devices connected to the SC-2 deter-
mines which of these options will work with your application. The SC-2 requires 7-20 VAC to operate correctly, and a fixed voltage source is required. When powered correctly, the green light on the SC-2 will illu-minate.
All switches and accessories must be powered by a separate power supply. This power supply must not be used to power the track.
If you use the SC-2 to operate at least one switch, the power can be supplied through the switch itself. No special wiring is needed; however, one of the switches must be properly connected to the Switch #1 terminals at the upper left. These terminals are labeled “1” in Figure 3.
Do not use the wall pack or the separate power terminals on the SC-2 if you are using it to operate switches.
If your SC-2 serves only as an accessory controller (no switches are connected), you must power the controller with the included Lionel AC wall pack or through track power. Do not power the SC-2 with both the wall pack and through track power.
To use the wall pack, simply plug the cord into the socket in the back of the SC-2, then plug the wall pack into the wall.
To use track power, attach a wire to the outside rail or to the #2 terminal on a Lionel Lock-On, and connect it to the top power terminal. This is the Common/Ground/U terminal. Attach another wire to the inside rail (the #1 terminal on a Lionel Lock-On) and connect the powered rail to the bottom terminal. These terminals are labeled “3” in Figure 3. Also, you can use these terminals to attach a separate transformer directly to the SC-2.
To use track power, you must be operating in Command mode so that the track voltage is constant. Varying track voltage will cause erratic operation of the SC-2.
Note! Note!
Note!
7
Installing the SC-2 on your railroadPowering your SC-2 (continued)
ACC3 ACC4
ACC1 ACC2
Track (Command only) or Auxiliary Power
Power/A
Common/Ground/U
Wall Pack Connection
2
1
3
Connect switch here to power from switch power
Figure 3. Powering the SC-2
8
Connecting Lionel switches to the SC-2
Installing the SC-2 on your railroad
Connect three switch wires to the SC-2 terminals. Begin with the ground
(common) for each switch. Listed below are ground terminal locations for some popular Lionel switches. Connect the ground terminal of each switch to the center screws of each terminal block on the SC-2.
HOW TO FIND THE RIGHT POST
If you’re in doubt about which binding post connects to the outside (ground) rail, check it with a meter or continuity tester, available from your local electronics supply store.
• On contemporary Lionel O gauge switches (6-23010 and 6-23011), ground is terminal number 2. Refer to Figure 4.
• On postwar 022 and MPC/early LTI O gauge switches (5132 and 5133), O-31 (14062, 14063) and O-72 (65165, 65166) ground is the center binding post. Refer to Figure 5.
• On many O-27 switches, including the O-42 and O-27 versions sold in the 1950s (1122 and 1122), and during the modern era (5121 and 5122e), ground is closest to the switch motor. See page 10 for special instructions for using O-27 with Command control. Refer to Figure 6.
• On super O switches (where two posts are together and one post is positioned on the side) ground is the side post.
Each of the SC-2’s ground termi-nals are independent of all other ground terminals. You must connect a ground wire for each device to the center set screw on that terminal.
When connecting the left and right terminal wires, make sure the wire throwing the switch “out” (curved) connects to the SC-2’s “Switch Out” terminal (#3). The wire throwing the switch “through” (straight) should connect to the SC-2’s “Switch Through” terminal (#1).
To identify which wire controls which switch function, begin by powering up each switch. Touch each of the two remaining switch wires to its ground terminal and note the action of the switch. Once the functions have been determined, power to the switch should be disconnected until the wiring to the SC-2 is completed.
When a switch is properly connected to the upper left terminals on the SC-2 and switch power is on, the SC-2’s green light should illuminate. This indicates the SC-2 is properly powered.
Note!
Hint!
9
Connecting Lionel switches to the SC-2 (continued)
Installing the SC-2 on your railroad
ACC3 ACC4
ACC1 ACC2
123 A TRACK
AUX.
3
1
2
2
1
3
#1 through (straight)#2 common
#3 out (curved)
SC-2
You can still control your switches manually. The manual controller is connected as shown above. No modification is required to this wiring.
Note
Connect one switch to these terminals to power the SC-2 from switch power
Switch controller (optional)
0-31 switch6-230116-23010
Figure 4. Wiring Lionel O gauge switches
ACC3 ACC4
ACC1 ACC2
U
Accessory Power
Fixed Voltage Plug
Switch controller (optional)
Figure 5. Wiring Lionel O-31 and O-72 gauge switches
10
Installing the SC-2 on your railroadModifying O-27 switches for use with the SC-2
O -27 type switches receive their power from variable track voltage. In order to operate
this type of switch with the SC-2 controller, you need to make the following modifications to allow the switch to operate from a fixed voltage power source.
First, take the top cover off of the switch by removing the screw. This will expose the double coils. Next, find the two wires that are located at the center of the two coils. These wires are contained inside one piece of insula-tion. Gently pull on the insulation to expose the wires. Now, clip the two wires about 1/2˝ from the coils. Using electrical tape, wrap the wire ends that come up from the bottom of the switch. Use the heat from your soldering iron to remove 1/4˝ of the varnish insulation from the remaining wires, then twist the wires together. Using your soldering iron, put a
small amount of solder on the ends of these wires and solder a jumper wire to them. Wrap this connection with electrical tape to keep it from coming in contact with the coil housing.
Before you replace the switch cover, you may need to cut a notch (using a hobby knife) for the wire to come through. You may also route the wire through the holes used to vent any heat generated by the coils on top of the cover. Replace the cover on the switch, then attach the jumper wire to a fixed voltage power source.
You will need to attach a ground wire from this separate power source to the outside rail of your track, or you can attach this ground wire to the “U” post on the PowerMaster.
Your switches can now be operated using the SC-2 Controller.
Control Rails
Ground
Coils and Plunger
Clip Wires Here
Control Rails
Ground
Jumper Wire (Connect to Fixed Voltage Power Source)
To SC-2To SC-2
Figure 6. Wiring Lionel O-27 gauge switches
11
Connecting hi-rail switch motors to SC-2
The SC-2 can control high current switch machines directly through its terminals.
Follow Figures 7 and 8 for proper installation. Do not use the SC-2 to control any device that draws more than 15 Amps when operating. The
controller can also be used with DC type switch machines according to the wiring diagram below. Additional parts are required for these machines and are available through any elec-tronics supply house.
Installing the SC-2 on your railroad
ACC3 ACC4
ACC1 ACC2
High current solenoid switch motors (NJ International) less than 15 amps.
A
U
NJ1 switch motor
The SC-2 can be powered from your switch power supply if one switch is connected to the upper left terminal posts on the SC-2.
Note!
Figure 7. Wiring NJ1 switches
12
Connecting hi-rail switch motors to SC-2 (continued)
Installing the SC-2 on your railroad
ACC3 ACC4
ACC1 ACC2
DC-type Hookup
switch motor
transformer (12 VAC)
A
USwitch Motor
1N4001, 2, 3 or 4
470ς
1N4001, 2, 3, or 4
Wallpack (required)
Note!
Parts needed for each DC-type switch motor:2-1N4001, 1N4002, 1N4003, or 1N4004 diodes1-470Ω 2-watt resistorAvailable from Newark Electronics or Radio Shack(To find the nearest Newark Electronics Sales Office, call 1-800-463-9275.)
You must hold down the AUX1 and AUX2 buttons until the switch has fully thrown.
Figure 8. Wiring DC-type switches
If you reprogram your SC-2 switch or accessory ID#s, your routes may not function
properly. We recommend that you clear and reprogram all routes. See page 18.
Program switch ID#’s 1, 2, 3, and 4
Command Base plugged in
Switch/turnout power ON
SC-2 ON
Slide SC-2 RUN/PROG switch to PROG
Press SW
Press 1 (the switch number)
Press SET
SC-2’s red light illuminates for-two seconds
You have assigned ID# 1 to the first switch connected to the SC-2. The next switch ID#’s (2, �, and �) are automatically assigned
Slide your SC-2 RUN/PROG switch to RUN; repeat these steps for other SC-2s installed on your railroad
The next SC-2 programmed will be Switch #5 or higher
Example
Note!
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW
AC
CR
TE
TR
EN
G
WS
TL
/ H
RN
BE
LL
DIR B
OO
ST
AU
X 1
CO
UP
LER
BR
AK
E
AU
X 2
CO
UP
LER
HA
LT
12
3
45
6
78
9
0
SET
1�
Programming the SC-2 switch numbers
Every switch needs an ID#. Take the time now to label your switches and
the terminals they connect to on the SC-2. Start numbering with #1 on the first SC-2 at the upper left corner. Follow the numbering scheme shown in Figure 1 on page 5.
SC-2 switch numbers are consecutive. Only program the first switch position on each SC-2. The next switch ID#s are programmed automatically by the SC-2.
For example, if you program the first switch connected to your SC-2 as switch #1, the switch numbers on that SC-2 become 1, 2, 3, and 4 (1 through 6 if programmed to control switches only). If you program the first switch connected to your SC-2 as switch #9, the numbers become 9, 10, 11, and 12 (9 through 14 if programmed to control switches only). See page 22 for instructions to program the SC-2 in switch
only mode.
Choose switch numbers between 1 and 99 (99 switches total). ID# 0 is reserved for clearing
the settings.
To program the switch numbers, be sure the Command Base and SC-2 are both powered up. Slide the SC-2 RUN/PROG switch (see Figure 9) to PROG. Press SW, the switch ID#, then SET. The SC-2’s red light will turn on for two seconds. Now slide the RUN/PROG switch back to RUN.
Note!
Note!
fig 8 page 11 SC-1 switch to program
PROG / RUN
Operating switches with your SC-2
Figure 9. RUN/PROG switch
Controlling switches with CAB-1
N ow that you've programmed the switch numbers, you can throw
the switches using the CAB-1 Remote Controller.
To operate another switch, you can just enter the ID# and select OUT or THROUGH without pressing SW again. This "short-hand" continues to work until you press another top-row address button (ENG, TR, ACC, RTE).
If the switch operates but throws to the wrong position, swap the wires connected to the outer set screws of the SC-2 termi-nals for that switch.
Operating switches with your SC-2
1�
Throw switch #1 OUT
Press SW
Press 1
Press OUT
Switch #1 is now curved, or OUT
Throw Switch #12 THROUGH
Press SW
Press 12
Press THROUGH
Switch #12 is now straight, or THROUGH
Example
Example
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
Note!
Note!
15
Creating routes around your railroad
Here’s a common scenario: to travel from the main line to the yard, you must
travel on a certain route. In Figure 10, for example, Switch #2 is THROUGH (straight),
Switch #4 is OUT (curved), and Switch #14 is THROUGH. With TrainMaster Command, you can throw all those switches with a single command—RTE.
Always check your RTE programming. Throw switches opposite the RTE direction, then press RTE and the ID#. Your route should immediately throw. To avoid overloading your power supply, switches in a route will operate in consecutive order, one at a time.
You can add more switches to a route at any time.
Any switch can be part of any route. A route may consist of any number of switches, although each switch may only be used once in the same route. Any switch can be included in any number of routes, creating a wealth of possibili-ties. Discover new pathways around your railroad with RTE. Routes are remem-bered forever—or until you clear them.
Note!
Operating switches with your SC-2
Figure 10. Switches in a route
Creating routes around your railroad (continued)
Assign switches #2 (THROUGH),
#4 (OUT) and #14 (THROUGH) to Route #1You do not have to program a route in sequential order. Any switch can be added to any route at any time.
Establish the route; press RTE
Press 1 (the route number)
Press 2 (the switch number)
Press THROUGH
Press SET
SC-2’s red light illuminates for two seconds.
Address the route; press RTE
Press 1 (the route number)
The SC-2 will operate previously programmed switch #2 briefly.Switch #2 is in the “through” direc-tion on Route #1.
Press � (the switch number)
Press OUT
Press SET
SC-2’s red light illuminates for two seconds.
Address the route; press RTE
Press 1 (the route number)
The SC-2 will operate previously programmed switch #2 and 4 briefly. Switch #4 is in the “out” direction on Route #1.
Press 1� (the switch number)
Press THROUGH
Press Set
SC-2’s red light illuminates for two seconds
Example
RTE
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW
AC
CR
TE
TR
EN
G
WS
TL
/ H
RN
BE
LL
DIR B
OO
ST
AU
X 1
CO
UP
LER
BR
AK
E
AU
X 2
CO
UP
LER
HA
LT
12
3
45
6
78
9
0
SET
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW
AC
CR
TE
TR
EN
G
WS
TL
/ H
RN
BE
LL
DIR B
OO
ST
AU
X 1
CO
UP
LER
BR
AK
E
AU
X 2
CO
UP
LER
HA
LT
12
3
45
6
78
9
0
SET
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
You may find it helpful before program-ming routes to make a list of all your
switches and their settings for each route. Refer to this list when programming and to identify routes later.
When a route is activated, there will be a delay between the activa-tion of each switch.
The SC-2 can control a maximum of nine
routes. When assigning a route ID#, choose a number between 1 and 9. Refer to the example below to create a route.
All SC-2’s must be on with the RUN/PROG switches in the RUN position during all route programming. The route will activate every time RTE and the ID# is pressed during program-
RTE
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW
AC
CR
TE
TR
EN
G
WS
TL
/ H
RN
BE
LL
DIR B
OO
ST
AU
X 1
CO
UP
LER
BR
AK
E
AU
X 2
CO
UP
LER
HA
LT
12
3
45
6
78
9
0
SET
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
RTE
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
Operating switches with your SC-2
Note!
Note!
Note!
You cannot remove an individual switch from RTE; you must clear the entire route and start again.
If you make an error during RTE programming, do not press SET. You must start over—press RTE, Route #, the switch number, its position, and then press SET.
1�
Select any route you’ve programmed by pressing RTE and entering the RTE
ID#. Make sure you press and hold the ID# button for one full second. This ensures the command is issued to every SC-2 on your railroad.
When you are pressing the ID# button, some of the switches may not actually throw until you’ve released the button. Switches activate at different times once you’ve selected the route —this keeps your system (and your railroad’s power supplies) from overloading due to simultaneous activation.
Be sure to let one route operate completely before selecting another. This will ensure trouble-free operation of the SC-2’s.
Unlike switch control, there is no “shorthand” for route control. Each time you wish to activate a route you must first press the RTE key. This must be done even if the last command issued was a route activation.
17
Operating switches with your SC-2
Activating routes
After a route is programmed, you may reprogram an individual switch setting
by following the steps on page 16. The existing switch direction assignment (AUX1 or AUX2) will be reassigned.
You cannot delete individual switches from a route assign-ment. You must clear the entire route and reprogram.
Modifying routes
activate Route #1
Press RTE
Press 1 for one full second
Route #1 has been selected: Switch #2 is THROUGH, Switch #� is OUT, and Switch #1� is THROUGH
Example
RTE
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
Note!
Note!
Operating switches with your SC-2
18
Clear Route #1 (erase all switch assignments)
Be sure the SC-2 RUN/PROG switch is set to RUN.
Press RTE
Press 1 (the Route ID #)
The RTE will activate.
Press SET-Hold for 2 seconds.
The red LED on the SC-2 will blink on and off for two seconds to indicate the route is cleared.
Route #1 is now ready for new switch assignments.
Example
RTE
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
Clearing routes
SW
AC
CR
TE
TR
EN
G
WS
TL
/ H
RN
BE
LL
DIR B
OO
ST
AU
X 1
CO
UP
LER
BR
AK
E
AU
X 2
CO
UP
LER
HA
LT
12
3
45
6
78
9
0
SET
To clear a route, press RTE, the RTE ID#, then press and hold
SET for two seconds. The route will operate one time then the route will be cleared from the SC-2. The red LED on the SC-2 will blink on and off for two seconds to indicate the route is cleared. Check that the route has been cleared by setting some switches for that route in the opposite direction then pressing RTE, then the RTE ID#. No switches should operate.
19
Operating accessories with your SC-2
Most Lionel accessories can be controlled by an SC-2. Start by
sequentially numbering the accessory termi-nals with the adhesive labels (included). Refer to Figure 11 for proper numbering order. Each accessory ID# can be used for either momentary or on/off functions. For any given accessory number, press AUX1 for Momentary operation of loaders and similar products or press AUX2 to toggle the acces-sory functions such as lights. Turn to pages 28-35 for wiring examples.
Keep in mind that accessories need to be externally powered. If the SC-2 will only operate accessories then you must either power the SC-2 through the track auxiliary power connection terminals or by a wall pack. Operating accessories may be powered by PowerMasters. This gives you keypad control over their voltage levels. See your Command Control instruction manual for details.
Connecting accessories to the SC-2
ACC3 ACC4
ACC1 ACC2
ACC2
ACC3ACC4
Accessory 2 momentary
Accessory 2 on/offCommon
Accessory 1 on/off
Accessory 1 momentary
Common
Figure 11. Accessory terminals
Note! Refer to pages 28-35 for accessory wiring diagrams.
20
Programming SC-2 accessory ID#’s
J ust like switches, accessories need ID#’s. To program the
ID#’s follow the example to the left.
Accessory ID#’s on the SC-2 are consecutive. When you program the first of the accessory terminals, you also program all remaining accessory terminals.
Choose accessory ID#’s between 1 and 99 (maximum accessory number is 99). Do not use 0 as an ID#. This is reserved for clearing the settings.
Program accessory (ACC) ID#’s 1 and 2
Command Base plugged in
SC-2 ON
Slide SC-2 RUN/PROG switch to PROG
Press ACC
Press 1 (the accessory number)
Press SET
SC-2’s red light illuminates for two seconds
You have assigned a ID# 1 to the first acces-sory connected to the SC-2. The next acces-sory is automatically assigned ID# 2.
Slide your SC-2 RUN/PROG switch to RUN; repeat these steps for other SC-2s installed on your railroad.
The next SC-2 programmed will be Accessory #� or higher.
Example
Note!
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW
AC
CR
TE
TR
EN
G
WS
TL
/ H
RN
BE
LL
DIR B
OO
ST
AU
X 1
CO
UP
LER
BR
AK
E
AU
X 2
CO
UP
LER
HA
LT
12
3
45
6
78
9
0
SET
Operating accessories with your SC-2fig 8 page 11 SC-1 switch to program
PROG / RUN
21
Controlling accessories with your CAB-1
N ow that you’ve programmed accessory numbers, you can
activate the accessories using the CAB-1 Remote Controller.
You may wish to create a list of your accessories, their ID#’s, and whether AUX1 or AUX2 should be used to control them. Use this list while you learn to use the SC-2 to help you operate your accessories correctly.
When the SC-2 is powered up, it will resume the last operating state for each accessory. In other words, if an accessory is on when power is switched off, the next time power is turned on, that accessory will be switched on.
Operating accessories
Turn the Command Base onTurn on auxiliary power. Now the SC-2 should be on.
Press ACC
Press 1
Press AUX2 to illuminate a building
Press AUX2 again to extinguish the light
Press ACC
Press 2
Press and hold AUX1 to activate an animated acces-sory Releasing AUX1 turns off the accessory
Once an ACC and its ID# is selected, you may then select AUX1 and AUX2 any number of times. These buttons will function until another top row address button (SW ACC RTE TR or ENG) is pressed.
Operating accessories with your SC-2
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
Note!
Example
Operating switches only
22
The SC-2 allows you to program it to operate one type of device only. For
example, you may choose to connect all your switches to one SC-2 and all your accessories to a second SC-2.
If you plan to use this SC-2 to control switches only, you may wire up to six switches to the controller, making use of all of the terminals. Wire the switches as described on pages 8-12. Once all connections have been made, turn on the power to your switches. The SC-2’s green light should come on to indicate it is powered. Now the unit must be programmed to control six switches. Follow the example to set the SC-2 for switch only mode.
If you decide to reprogram an SC-2 from standard mode to accessory only mode, all route assignments on that SC-2 will be cleared.
Switch only operationPlug in Command Base.
Turn on switch power. Now the SC-2 should be on.
Slide the PROG/RUN switch on the SC-2 to PROG.
press ACC
press 0 (for no accessories)
press set
The SC-2’s red light will illuminate for two seconds.
press SW
press 1 (the switch number)
press set
The SC-2’s red light will illuminate for two seconds.
Slide the PROG/RUN switch on the SC-2 to RUN.
You have now assigned the number 1 to the first switch connected to the SC-2. The next switch numbers 2 through � are automatically assigned. Repeat this process for all other SC-2s on your railroad.
The next SC-2 controlled switches programmed must be programmed as ID# 7 or higher.
Example
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW
AC
CR
TE
TR
EN
G
WS
TL
/ H
RN
BE
LL
DIR B
OO
ST
AU
X 1
CO
UP
LER
BR
AK
E
AU
X 2
CO
UP
LER
HA
LT
12
3
45
6
78
9
0
SET
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW
AC
CR
TE
TR
EN
G
WS
TL
/ H
RN
BE
LL
DIR B
OO
ST
AU
X 1
CO
UP
LER
BR
AK
E
AU
X 2
CO
UP
LER
HA
LT
12
3
45
6
78
9
0
SET
Note!
Advanced operation
Operating accessories only
2�
Accessory only operationPlug in Command Base.
Turn on accessory power or plug in the wall pack. Now the SC-2 should be on.
Slide the PROG/RUN switch on the SC-2 to PROG.
press SW
press 0 (for no switches)
press set
The SC-2’s red light will illuminate for two seconds.
press ACC
press 1 (the accessory number)
press set
The SC-2’s red light will illuminate for two seconds.
Slide the PROG/RUN switch on the SC-2 to RUN.
You have now assigned the number 1 to the first accessory connected to the SC-2. The next accessory numbers 2 through � are automatically assigned. Repeat this process for all other SC-2s on your railroad.
The next SC-2 controlled acces-sories programmed must be programmed as ID# 7 or higher.
Example
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW
AC
CR
TE
TR
EN
G
WS
TL
/ H
RN
BE
LL
DIR B
OO
ST
AU
X 1
CO
UP
LER
BR
AK
E
AU
X 2
CO
UP
LER
HA
LT
12
3
45
6
78
9
0
SET
SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0SW ACC RTE TR ENG
WSTL / HRN
BELL
DIR
BOOST
AUX 1
COUPLER BRAKE
AUX 2
COUPLER
HALT
1 2 3
4 5 6
7 8 9
0
SW
AC
CR
TE
TR
EN
G
WS
TL
/ H
RN
BE
LL
DIR B
OO
ST
AU
X 1
CO
UP
LER
BR
AK
E
AU
X 2
CO
UP
LER
HA
LT
12
3
45
6
78
9
0
SET
If you plan to use this SC-2 to control accessories only, you may wire twelve accessories functions to the controller, making use of all of the terminals. This mode gives you six momentary and six on/off controls. Wire the accessories as described on page 19. When the SC-2 is wired to operate accessories only, a wall pack may be used, or the SC-2 must be wired to the track or an auxiliary power supply. Once all connections have been made, plug the power cord from the wall pack into the SC-2 and plug in the wall pack or turn on track power. The SC-2’s green light should come on to indicate it is powered. Now the unit must be programmed to control twelve accessories (six Momentary and six toggle on /off functions). Follow the example to set the SC-2 for accessory only mode.
If you decide to reprogram an SC-2 from standard or switch only mode to accessory only mode, all route assign-ments on that SC-2 will be cleared.
Note!
Advanced operation
Advanced operationOperating output terminal connections
Use Table 2 below as a guide for programming and connecting the SC-2 in its various operating modes.
ACC3
ACC4
ACC1
ACC2
Uppe
r Row
Left
Term
inal
Cent
er
Term
inal
Righ
t Te
rmin
al
Low
er R
ow
Op
erat
ing
Left
Ter
min
al
Cent
er T
erm
inal
Ri
ght T
erm
inal
Pr
ogra
mm
ing
M
ode
Bloc
k Bl
ock
Bloc
k Re
quir
ed
Scre
ws
Scre
ws
Scre
ws
Left
Ce
nter
Rig
ht
Left
Ce
nter
Rig
ht
Left
Ce
nter
Rig
ht
ACC1
AUX
1 C
OM1
ACC
1 AU
X2
ACC3
AUX
1 C
OM3
ACC
3 AU
X2
ACC5
AUX
1 C
OM5
ACC
5 AU
X2
SW 0
set
ACC2
AUX
1 C
OM2
ACC
2 AU
X2
ACC4
AUX
1 C
OM4
ACC
4 AU
X2
ACC6
AUX
1 C
OM6
ACC
6 AU
X2
ACC
# se
t
SW1
COM
1
SW
1 SW
3
CO
M3
SW3
SW5
COM
5 S
W5
ACC
0 se
t
SW2
COM
2
SW
2 SW
4
CO
M4
SW4
SW6
COM
6 S
W6
SW #
set
SW
1
CO
M1
SW1
SW3
COM
3
SW
3 AC
C1 A
UX1
COM
1 A
CC1
AUX2
SW
# s
et
SW2
COM
2
SW
2 SW
4
CO
M4
SW4
ACC2
AUX
1 C
OM2
ACC
2 AU
X2
ACC
# se
t
Uppe
r Row
Low
er R
ow
Uppe
r Row
Low
er R
ow
Uppe
r Row
Low
er R
ow
Acc. Only Switches Only
� Switches 2 Acc.
Table 2. Output terminal connections
2�
25
TroubleshootingReplacing the fuse
The controller is protected by an internal fuse. If your SC-2 stops operating, first
check your wiring to be certain you have not wired the SC-2 incorrectly. Also, be certain that no wires have come loose or are broken. Check that your switches are powered. If a wall pack is being used, check that it is firmly plugged into the back of the SC-2. If the green light on the SC-2 is still out, then the fuse probably needs to be replaced.
To replace the fuse in the SC-2, discon-nect the power from the controller, and turn off all power to your railroad. Next, remove the four screws in the corners of
the plastic case (see Figure 12). Carefully remove the bottom cover from the SC-2. DO NOT TOUCH ANY OF THE ELECTRICAL COMPONENTS INSIDE. THEY ARE STATIC SENSITIVE AND COULD BE DAMAGED. The fuse is located near the power plug on the back side of the case. Carefully pull the fuse out of its holder (a fuse puller is recom-mended).
Replace the fuse with a 2 X 5mm barrel type 1.5 Amp fast acting fuse. These are available from automotive and electronic suppliers.
Press the fuse into its holder, then replace the plastic base and the four screws.
Fuse 4 screws
Figure 12. Fuse replacement
Troubleshooting
Everything is connected but nothing happens.1. Check all wiring to switches. Check that the switches are powered and a switch is connected to
the SW 1 position. 2. If using a wall pack, check that it is connected to the SC-2 and plugged into a powered wall
outlet.3. If you are powering the SC-2 from the track, be sure track power is on and connections to the
track are secure. PowerMasters should be switched to Command mode and switched on by pressing TR, ID#, then BOOST.
4. Check the fuse in the SC-2 and replace if bad. 5. Use a test light to check for power. The SC-2 requires 7-20 V AC to operate properly.6. If the SC-2’s green light still does not illuminate, contact your Lionel Authorized Service Station
for assistance.
The SC-2’s red light does not blink when I send commands from the CAB-1 Remote Controller.1. The SC-2’s red light will only blink when you enter a RTE, SW or ACC command with an ID# of
one of the devices connected to that SC-2.2. Check to be sure the Command Base is plugged in and that its red light blinks when a command
is issued from a CAB-1 Remote Controller. The Command Base must receive the signal from the CAB-1 in order for the command to be passed to the SC-2. See your TrainMaster Owner’s Manual for additional information.
3. Try repositioning the SC-2 closer to the track or Command Base. The communications signal from the Command Base may be impeded by structural or electrical elements in the area. Be sure the SC-2 is not sitting on a metal surface.
4. Ensure that the Command Base is properly connected to the track or track power supply. See your TrainMaster Owner’s Manual for additional information.
5. Turn off all other electronic devices in the area. They may interfere with the Command Base communication signal.
When I operate a switch, it throws the opposite direction.Reverse the wires from the switch attached to the outer (left and right) set screws of the SC-2
terminal block, or at the switch.
When I operate an accessory it operates continuously when it should shut off.
Accessories connected to the SC-2 will respond to the AUX2 ON/OFF command when connected to the right and center set screws of a terminal block. For momentary control, connect to the left side of the terminal block and use the AUX1 momentary command.
When I operate an accessory it operates briefly then stops.Accessories connected to the SC-2 will respond to the momentary AUX1 command, when
connected to the left and center set screws of a terminal block. For on /off operation, connect to the right and center set screws and use the AUX 2 on/off command.
2�
Answers to questions
I connected my SC-2, but I can’t get the switches to throw.1. You must program the SC-2 with switch ID numbers before you can use the SC-2 to operate
switches.2. Verify the switches are connected properly and the SC-2’s green light is on.
I connected my SC-2, but I can’t get the accessories to operate.1. You must program the SC-2 with accessory ID numbers before you can use the SC-2 to operate
accessories.2. Verify that the accessories are connected properly and the SC-2’s green light is on.3. Accessories connected to the left side of a terminal block will only respond to AUX1 momentary
commands. AUX2 on/off commands only control accessories connected to the right side of a terminal block.
I programmed my switches and accessories on the SC-2 but now I can’t remember their ID#’s!1. Place numbered “flags” or stickers at each switch and accessory. This will help you learn their
numbers; later, you can remove them. You may also choose to draw a layout diagram and label ID#’s there. Small localized diagrams positioned around a large layout may also help.
2. Switch and accessory ID#’s are consecutive for each SC-2. Try activating each ID number in order and watch to see what device operates.
3. ID#’s may be reprogrammed at any time. If you can’t easily determine which switch and acces-sory numbers have been used, you may reprogram ALL the SC-2s with new numbers. Be sure to label all switches and accessories. You will have to clear and reprogram all route assignments too with this method.
I incorrectly entered some information when programming a RTE. What should I do?
Making errors during route programming is no big deal. Just remember that as long as you don’t press SET, you haven’t programmed anything. Start over at the RTE command for that switch: RTE, route ID#, switch number, the direction you want to throw (AUX1 or AUX2), and finally, SET. Pressing SET commits the command string to memory. If you pressed SET already, read on.
I added a switch to a route that I don’t really want. How can I remove it?You must clear the entire route and reprogram it. Press RTE, route ID#, SET. This erases all switch
assignments in that route.
Only one switch will operate from the SC-2.Check the connections to all other switches wired to the SC-2. Unlike the previous version of
this device, the SC-1, the common terminals on the terminal strips are not tied together. You must connect a common lead to each terminal on the SC-2.
Can I operate switch machines and devices by other manufacturers with the SC-2?
The SC-2 can control any low voltage momentary or ON/OFF device through its terminals as long as the current does not exceed 15 Amps.
27
TroubleshootingAnswers to questions (continued)
Water Tower (�0/1�8)
Accessory connectionsRefer to the following illustrations as you
connect your accessories. Though many of these illustrations show connections to the ACC2 terminals, you may use any available ACC terminal and its adjacent common terminal.
You must connect a common lead for each accessory connected to your SC-2. The common termi-nals on the terminal blocks are not internally connected.
ACC2 ACC2
ACC1 ACC1
Rotary Beacon (�9�/�9�/�-128�1); Control Tower (192/�-12878); Floodlight Tower (195/�95/�-12759/�-1288�); Icing Station (�52/�-128�7/�-1�158);
ACC2 ACC2
ACC1 ACC1
Power Supply
A
U
Control with AUX2
Power Supply
A
U
Control with AUX1
Note!
28
29
Accessory connectionsLumber Mill/Sawmill (���/�-1287�)
Switch Tower (��5)
ACC2 ACC2
ACC1 ACC1
right rear corner of sawmill
ACC2 ACC2
ACC1 ACC1
lights
motor
Example:ACC2 AUX2 turns on lightsACC2 AUX1 (hold) activates tower while button is pressed. ACC2 AUX 2 turns lights off.
Control with AUX1
Control lights with ACC2 AUX2 mechanism with ACC2 AUX1
Power Supply
A U
Power Supply
A
U
ACC2 ACC2
ACC1 ACC1
�0
Accessory connectionsDiesel Fueling Station (�15/�-12877/�-1�15�)
lamp
Oil Derrick (��5/�-12902/�-1�15�)
ACC2 ACC2
ACC1 ACC1
mechanism
Control lights with ACC2 AUX2mechanism with ACC2 AUX1
Power Supply
A
U
Power Supply
A
U
Control with AUX2
�1
Accessory connectionsLumber Loader (���)
ACC2 ACC2
ACC1 ACC1
A
B
C
Control with AUX2 ACC2 AUX2 lampsACC2 AUX1 load
Power Supply
A
U
Log Loader (1��/�-12915)
ACC3 ACC4
ACC1 ACC2
Unlo
ad
Driv
e
Lam
ps
ACC1 AUX1 UnloadACC2 AUX1 DriveACC2 AUX2 Lamps
Power Supply
A
U
Whistle Shack (125/�-127�7/�-1290� diesel horn variant)
ACC3 ACC4
ACC1 ACC2
Control with AUX1 Power Supply
A
U
�2
Accessory connectionsCoal Tower
ACC2 ACC2
ACC1 ACC1
Control load with ACC2 AUX2 Control unload with ACC2 AUX1
Black UWhite unloadRed load
Power Supply
U
A
Aircraft Plyon (�-1�101)
ACC2 ACC2
ACC1 ACC1
Power Supply
U
A
Control with AUX2
��
Accessory connectionsFreight Station (�5�/�-1�152)
ACC2 ACC2
ACC1 ACC1
Clights
mechanism
Mechanism with ACC2 AUX 1Light ACC2 AUX2
Power Supply
A
A
B
C
U
Oil Drum Loader (�-22997)
ACC2 ACC2
ACC1 ACC1
Power Supply
A
Control lights with ACC2 AUX2
Control motor with ACC2 AUX1
motor
light
��
Accessory connections
Bascule Bridge
ACC2 ACC2
ACC1 ACC1
Power Supply
U
A
U
A
Control with AUX1
�5
Accessory connectionsUncoupling Track (�-�51�9)
ACC2 ACC2
ACC1 ACC1
Control with AUX1 Power Supply
A
U
Limited Warranty/Lionel Service
T his Lionel product, including all mechanical and electrical components, moving parts, motors and structural
components, except for light bulbs, is warranted to the original consumer-purchaser, for one year against original defects in materials or workmanship when purchased through an authorized Lionel merchant.
This warranty does NOT cover normal wear and tear, light bulbs, defects appearing in the course of commercial use, or damage resulting from abuse or misuse of the product by the purchaser. Transfer of this product by the original consumer-purchaser to another person voids this warranty. Modification of this product voids this warranty.
Any warranted product which is defective in original materials or workmanship and is delivered by the original consumer-purchaser to Lionel L.L.C. or an authorized Lionel L.L.C. Service Center, together with proof of original purchase will, at the option of Lionel L.L.C., be repaired or replaced, without charge for parts or labor. In the event the defective product cannot be repaired, and a replacement is not available, a refund of the original purchase price will be granted. Any products on which warranty service is sought must be sent freight or postage prepaid, as transportation and shipping charges are not covered by the warranty.
In no event shall Lionel L.L.C. be liable for incidental or consequential damages.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply to you.
This limited warranty gives you specific legal rights, and you may have other rights which vary from state to state.
Instructions for Obtaining ServiceIf service for this Lionel L.L.C. product is
required, bring the item, along with your dated sales receipt and completed warranty information to the nearest Authorized Lionel Service Center.
Your nearest Lionel Service Center can be found by calling 1-800-4-Lionel, or by accessing our Website at www.lionel.com.
If you prefer to send your product back to Lionel L.L.C. for repair in Michigan, you must first call 586-949-4100 or FAX 586-949-5429, or write to Customer Service, P.O. Box 748, New Baltimore, MI 48047-0748, stating what the item is, when it was purchased and what seems to be the problem. You will be sent a return authorization letter and label to ensure your merchandise will be properly handled upon receipt.
Once you have received your return authorization and label, make sure that the item is packed to prevent damage during shipping and handling. We suggest that you use the product’s original packaging. This shipment must be prepaid and we recommend that it be insured.
Please make sure you have followed all of the above instructions carefully before returning any merchandise for service. You may choose to have your product repaired by one of our Authorized Lionel Service Centers after its warranty has expired. A reasonable service fee will be charged.
Warranty InformationPlease complete the information below and
keep it, along with your dated sales receipt. You must present this and your dated sales receipt when requesting warranty service.
Name ____________________________
Address ___________________________
Place of Purchase ____________________
Date of Purchase_____________________
Product Number _____________________
Product Description ___________________
©2003 LIONEL L.L.C., CHESTERFIELD, MI 48051-2493UNITED STATES OF AMERICA
PRINTED IN CHINA
Top Related