BI 2
9.08
.03
Sci2
006
YXLON. The reason why 1
YXLON International
Industrial Computed Tomography
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 2
CT - applications
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 3
Computed Tomography (Line Detector)
CT - principles
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 4
0
2000
4000
6000
8000
10000
12000
Detektorkanäle
Zähl
rate
absorption profile
sinogram reconstructed image
CT - principles
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 5
volume data
stack of 2D images
CT - principles
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 6
Computed Tomography (Flat Panel)
CT - principles
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 7
volume data
set of projections
CT - principles
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 8
PU foam
Al foam
Al foam/steel compound
CT - applicationsVizualization Vizualization / NDT // NDT /
geometrical measurementgeometrical measurement
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 9
NDTNDTAluminum casting
CT - applications
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 10
Visualization Visualization tool for
injection moulding
CT - applications
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 11
Geometrical measurement
cylinder/crank case
CT - applications
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 12
VisualizationVisualizationSandstone sculpture(Cathedral of Mainz)
CT - applications
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 13
NDTNDTcasting defect in
cylinder/crank case
CT - applications
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 14
NDTNDTheater plug
CT - applications
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 15
CT - applications
NDTNDTwelding seam
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 16
CT - applications
Vizualization Vizualization / NDT/ NDTceramic sphere
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 17
CT - applications
Vizualization Vizualization / NDT/ NDTcylinder head
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 18
CT - applications
Vizualization Vizualization / NDT/ NDTmounted device
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 19
CT - applications
Vizualization Vizualization / NDT // NDT /geometrical measurementgeometrical measurement
truck tire
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 20
- defect analysis
- position control
- geometrical measuring
2D images orvolume data surface reconstruction
(CAD model)
CAD modelnominal/actual comparison
- nominal/actual comparison
- rapid prototyping
- FE simulations
polygon extraction(STL model)
CT - applications
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 21
nominal/nominal/actual actual value comparisonvalue comparison
CT - applications
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 22
solidification solidification simulationsimulation
CT - applications
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 23
Reverse EngineeringReverse EngineeringReproduction of a cylinder head (1937 model)
CT - applications
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 24
CT - systems
General General remarksremarksresolution vs. object size
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 25
225 kV Minifocus X-ray source(available with Microfocus)
< 220 mm Ø< 500 mm height< 15 kg
Line detector array < 50μm pitch< 1% contrast resolution(available with Flat-Panel)
SmallSmall for objects with
CT - systems
4-axis high accuracy manipulator (+/- 10 µm)
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 26
CT - systems
160 ... 450 kV X-ray source
Line detector array120 μm / 0.5% or Flat-Panel400 µm / 1 %
< 335 mm Ø< 500 mm height< 30 kg
CompactCompact for objects with
5-axis high load manipulator (+/- 50 µm)
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 27
< 525 / 900 mm Ø< 1,000 mm height< 150 kg
Line detector array 100 μm pitch0.1% contrast resolution
CT - systems
450 kV X-ray source225 kV Minifocus
MediumMedium for objects with
5-axis high load manipulator (+/- 50 µm)
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 28
450 kV X-ray source
Line detector array(100 μm / 0.1%) and Flat-Panel(400 µm / 1 %)
CT - systems
< 525 / 900 mm Ø< 1,200 mm height< 50 kg
MediumMedium for objects with
6-axis high accuracy manipulator (+/- 25 µm)
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 29
2.5 MeV linear accelerator
< 800 / 1300 mm Ø< 1,500 mm height< 350 kg
CT - systems
Line detector array600 μm pitch (250 µm available)0.5% contrast resolution
LargeLarge for objects with
5-axis high load manipulator (+/- 50 µm)
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 30
DetectorDetector--Capabilities Capabilities for geometrical measurement
CT - systems
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 31
Line detector array170 kVAluminum
CT - systems
ComparisonComparisonlow energy appl.
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 32
CT - systems
ComparisonComparisonlow energy appl.
Flat Panel170 kVAluminum
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 33
CT - systems
ComparisonComparisondynamic range
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 34
CT - systems
ComparisonComparisonhigh energy appl.
Line detector array450 kVAluminum
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 35
CT - systems
ComparisonComparisonhigh energy appl.
Flat Panel450 kVAluminum
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 36
Computed Tomography (3D-CT)
CT - principles
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 37
CT - systems
ComparisonComparisonLDA vs. Flat Panel
speedspatial resolution
contrast resolutiondetectability
VisualizationNDT
geometrical measurementreverse engineering
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 38
CT - systems
CapabilitiesCapabilities
YXLON-CT-systems are used withLDA (2D-CT) or FlatPanel(3D-CT) or both combinedMicro-, Mini-, Macro-X-ray sourcesRadioisotopes, Linear acceleratorson-top-equipment
YXLON-CT-systems are usable for any material (as long as absorbing) any object (as long as penetrable)any application (as far as thinkable)
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 39
FeaturesFeatures
CT - systems
YXLON-CT-systems are optimized forhigh performance (speed, resolution)high throughput (in-line reconstruction)high accuracy (manipulation)high reliability (industrial design, remote service)
YXLON-CT-systems includeeasy-to-use operator interface3D-visualizationimage analysis & measurement toolsopen interfaces
BI 2
9.08
.03
Sci2
006
YXLON. The reason why 40
YXLON International X-Ray GmbH
www.yxlon.com
Top Related