Can Do Home Inspection
Date:
Visual Property InspectionAnywhere Ave.,
My Town, USA 20000
Prepared for:Client A
20 Nowhere St.Your Town, USA 11111
Inspected by :BOB VAN STRY
Lic.# 1600005960
34 Metzner Rd.,Ronkonkoma, New York 11779
Phone : (631) 467-89001
e-mail : [email protected]
PROPERTY AND SITE ____________________________________________________________________________________________________LIMITATION: Restricted / No Access Debris / Obstruction Snow / Ice Cover Vegetation/Tree/ShrubCONDITIONS: Clear / Sunny Cloudy / Overcast Rain / Snow Approx. Temperature 43 Wet / Swampy / Damp / Dry / Frozen Ground Approx. Hydrant Distance 20 feet._________________________________________________________________________________________________________________BUILDING Approx. 5 Years Old Traditional Cape Cod Colonial Hi-Ranch Dutch Colonial Ranch Bungalow VictorianRural Bi-Level Tri-Level Addition Condo Row / Town Other 2 Story 3 Story
Items like in-ground sprinkler system, above ground pool and components, hot tub and deck wet bar were not checked nor inspected as per our agreement.Visible evidence indicates an acceptable level of construction.No movement is evident.Inspection of the structural components was restricted due interior finishes.
_________________________________________________________________________________________________________________
LANDSCAPING Slopes to House FUNCTIONALRavine Site Erosion Flower Bed Hedge / Shrub Tree / Vine Earth to Wood No Swale Other_________________________________________________________________________________________________________________
DRIVEWAY Slopes to House DAMAGED—NO Paving Stone Gravel Concrete Asphalt Dirt Parking Area None _________________________________________________________________________________________________________________
WALKWAY/PATH Slopes to House DAMAGED—NO Paving Stone Gravel Concrete Asphalt Brick Slate Dirt Other_________________________________________________________________________________________________________________
FRONT PORCH Unsecured DAMAGED—NO Metal Wood Composite Brick Block SlateSpalling Crack Corrosion Rot Settlement Repaint / Stain Weather Seal Caulk
Brick landing and front steps looked ok. Need to remove old stains. Small front deck looked ok._________________________________________________________________________________________________________________
LIGHTING OPERATIONAL—YES None Unsecured Not Tested___________________________________________________________________________________________________RECEPTACLE OPERATIONAL—YES No Cover Damaged GFCI_________________________________________________________________________________________________________________
RAILING Unsecured FUNCTIONAL Metal Wood PVC Incomplete None
Need to add spindles to handrail on steps._________________________________________________________________________________________________________________
2
DECK / PATIO Unsecured Slopes to House DAMAGED—NO Composite Wood Brick Block Concrete Metal Trex Slate Paving Stone Patio Block StoneCrack Settlement Spalling Deterioration Mold Mildew Rot
Back deck looked ok._________________________________________________________________________________________________________________
RAILING Unsecured FUNCTIONALMetal Wood PVC Incomplete None___________________________________________________________________________________________________RETAINING WALL Not Stable Concrete block wall looked ok DAMAGED—NO No Weep Holes Wood Concrete Stone BrickCrack Spalling Deterioration Rot Lean
3
EXTERIOR ______________________________________________________________________________________________________________LIMITATION: Clearance Seasonal Storm Windows Debris / Obstruction Shrub / Tree / Hedge / Vines / Ivy Snow / Ice Cover Restricted / No Access Parged Other ______________________________________________________________________________________________________________
FOUNDATION WALL Not Exposed Limited Exposure FUNCTIONAL Poured Concrete Block Brick StoneExterior Rigid Insulation PWF / Wood Piling / Pier Cracking / Spalling Mildew / Mold
Stain / Rot Frost Heave
Regrading away from foundation is needed in some areas to help keep water away._______________________________________________________________________________________________________________WALL SURFACE No Ground Clearance DAMAGED—NO Aluminum Composite / Concrete Brick / Block Stone Stucco Vinyl Siding Wood Siding Steel / Shingle Split / Loose Repoint Repaint RecaulkCrack / Spalling Mildew / Mold Stain / Rot Blister / Peel
Siding looked ok. Finish siding under back and front deck. Add flashing between deck and siding._______________________________________________________________________________________________________________WINDOWS Inspected with Binoculars DAMAGED—NO Storm Unsecured Repaint Recaulk Weather-strip Mildew / Mold Stain / Rot Poor Trim________________________________________________________________________________________________________________
WINDOW WELL Improper Drainage Well Covers Clean DAMAGED—NO Clean out window wells. Make wells several inches deeper.______________________________________________________________________________________________________________DOORS Binds Damaged DAMAGED—NO Storm Unsecured Repaint Recaulk Weather-strip Mildew / Mold Stain / Rot Split / Dent
__________________________________________________________________________________________LIGHTING OPERATIONAL—YES None Unsecured Not Tested____________________________________________________________________________________________________RECEPTACLE OPERATIONAL—YES No Cover Damaged GFCI
Install GFCI Reverse Polarity No Ground Open Ground____________________________________________________________________________________________________
BASEMENT WALKOUT Covered OPERATIONAL—YES Poor Condition No Railing No Drain Clean Drain Leak
4
Crack / Spalling Mildew / Mold Frost Heave Reparge
Keep drain clear to prevent pooling water from entering the basement.
GARAGE / CARPORT
5
_______________________________________________________________________________________________________________TYPE Attached Built-In Detached Single Double Insulated / Heated Attic Access________________________________________________________________________________________________________________DOOR Binds Damaged OPERATIONAL—YES Automatic Sectional Wood Metal Fiberglass Eye Sensors No Safety Stop Stain / Rot Corrosion Door worked ok.________________________________________________________________________________________________________________FLOOR Crack Asphalt Concrete Gravel Dirt Covered Finished Stain / Rot Settlement ________________________________________________________________________________________________________________WALL No Fire Barrier DAMAGED—NO Drywall / Plaster Brick / Block / Stone Wood Stain / Rot House Wall Drywalled Holes in Fire Barrier ________________________________________________________________________________________________________________WINDOW Binds Damaged Blocked Not Tested N/A________________________________________________________________________________________________________________
CEILING No Fire Barrier DAMAGED—NO Drywall / Plaster Crack Wood Stain / Rot Holes In Fire Barrier Attic Hatch Pull Down Stairs________________________________________________________________________________________________________________LIGHTING None Unsecured OPERATIONAL—YES Install GFCI Reverse Polarity No Ground Open Ground________________________________________________________________________________________________________________
CIRCUIT WIRE Concealed Unsecured Improper Not In Conduit FUNCTIONAL
________________________________________________________________________________________________________________
ACCESS DOOR To HOUSE OPERATIONAL—YES Auto Door Close Metal Clad Metal Wood CompositeGas Proof Damaged Stain / Rot Corrosion Adjust Spring Hinges
Adjust springs to keep door closed for fire safety.Add a second handrail to the other wall for added safety because of the width of the steps.
ROOF STRUCTURE
6
_______________________________________________________________________________________________________________INSPECTED BY: Binocular Roof Edge Walk On No Access
LIMITATION Deck / Patio Gravel / Flat Height Steep Slope Rain / Snow / Ice Cover Solar Panel Fragile Other________________________________________________________________________________________________________________MAIN ROOF Flat Gable Valley Hip Shed Other Poor Pitch Est. Age 5 Years________________________________________________________________________________________________________________
GUTTER / DOWNSPOUT Unsecured FUNCTIONAL TYPE Aluminum Galvanized Copper Plastic Incomplete Dent / Split Corrosion Leak Gutter Covers
DRAINAGE Above Ground Below Ground Spill / Roof Extend Leader Redirect Leader Clean
Clean and maintain gutter system regularly to reduce water damages as a result of clogging. House is located in a high vegetation area. Extend all downspouts minimum 6' away from foundation to reduce wall deterioration, potential water entry and subsequent damages.________________________________________________________________________________________________________________
FASCIA / SOFFIT Not Vented DAMAGED—NO Aluminum Wood Vinyl Other Loose Mildew / Mold Stain / Rot Corrosion _______________________________________________________________________________________________________________
COVERING NUMBER OF LAYERS 1 DAMAGED—NO Asphalt Shingle Fiberglass Shingle Concrete / Clay Tile Wood Shingle Wood Shake Tar / Gravel Metal
Nail Exposed / Pop Loose / Missing Broken Crack Patched Mildew / Mold Fungus / Moss Worn
Curl / Claw Stain / Rot Improper Installation
Roof was in good condition.
LIFE EXPECTANCY Typical Middle End ExceededAnticipate regular maintenance to the roofing surface, gutters and related accessories to provide intended drainage function and reduce the potential for leaks to develop. Gutter clogs and loose or damaged components can lead to leaks that can cause major, sometimes costly damage to both structural and finish materials in the home.________________________________________________________________________________________________________________
ACCESSORY Unsecured DAMAGED—NO Air Vent Exhaust Vent Vent Stack Turbine Electric Mast Solar Panel Skylight Dish Antenna________________________________________________________________________________________________________________FLASHING Not Checked / Concealed DAMAGED—NO Chimney Dormer Drip Edge Flat Roof Skylight Roof to Wall Stack Valley Roll RoofingAluminum Galvanized Copper / Lead Rubber Gap Loose Crack Deterioration Corrosion Tarred PatchedReseal Recaulk Improper Replace When Re-Roofing ________________________________________________________________________________________________________________
CHIMNEY / VENT Leaning DAMAGED—NO Fireplace Boiler Gas Insert Other Block Stone Metal Wood Stucco Chase
7
Crack Spalling Deterioration Corrosion Loose Abandoned No Wind Cap Metal Liner Required
Fireplace and boiler chimney were in a wood frame chase with metal flue pipes inside. Exterior of chase looked ok. Chimney looked ok on outside where I could see it. ________________________________________________________________________________________________________________CHIMNEY CAP None DAMAGED—NO Concrete Masonry Metal OtherCrack Spalling Deterioration Corrosion LooseSmall areas I could see looked ok.________________________________________________________________________________________________________________
VISIBLE FLUE LINER None NOT VISIBLE Brick Block Clay Concrete Metal Metal Insert Rain CapDeterioration Corrosion Loose Crack Spalling Improper Advise Cleaning / SweepingContact a qualified technician to inspect the interior flue pipe- liner prior to purchasing the home. Clean and maintain chimney flues to promote safe and efficient operation of heating appliances and fireplaces. This should be done annually or as prescribed by the chimney technician as obstructions can occur._________________________________________________________________________________________________________________
ATTIC ___________________________________________________________________________________________________________LIMITATION: No Access Sealed Stored Items Looked In Entered Hatch Pull Down Insulated________________________________________________________________________________________________________________
8
STRUCTURE Truss Rafter DAMAGED—NO Warped Stain Rot Sag Loose Split
Attic area looked ok.________________________________________________________________________________________________________________
SHEATHING Condensation DAMAGED—NO Composite Thermal Board Plywood BoardFelt Paper Mildew Mold Sag Loose Stain Rot Delaminated________________________________________________________________________________________________________________INSULATION Estimate Depth 6-8” FUNCTIONAL Radiant Barrier Concealed Finished None Vapor Barrier Fiberglass Mineral Cellulose FoamWood Shavings Rigid Plastic Other Batt Blown Loose Sprayed Required
Insulation looked good.________________________________________________________________________________________________________________
VENTILATION None FUNCTIONAL Soffit Gable End Turbine Mechanical Baffles Roof Ridge Blocked Required________________________________________________________________________________________________________________
EXHAUST DUCT Concealed DAMAGED—NO
Not Insulated Into Attic Plastic Flex Metal________________________________________________________________________________________________________________
ELECTRICAL Concealed DAMAGED—NO Abandoned Knob & Tube Open Slice Frayed Open Junction Boxes Unsecured
ELECTRICAL SERVICE / PANEL ________________________________________________________________________________________________________________For all electrical deficiencies noted below consult a qualified Licensed electrician to review and provide repairs, improvements and upgrades as needed. These recommendations can impact safety in the home and should be addressed._______________________________________________________________________________________________________________
9
SERVICE ENTRANCE Underground Overhead No Conduit No Drip Loop 120-Volt 120/240 Volt Unsecured Frayed Service Line
ENTRANCE CABLE Concealed Aluminum CopperMAIN DISCONNECT Switch / Cartridge Fuse BreakerDISCONNECT RATING 200 Amps Have Electrician Evaluate________________________________________________________________________________________________________________DISTRIBUTION PANEL Not Opened DAMAGED—NO LOCATION BASEMENT Non Standard InstallationObstructed Unsecured Corrosion Obsolete
PANEL RATING 200 Amps Room for Expansion
FUSE Breaker Glass / Screw Cartridge Time Delay GFCI / AFCI Breaker Blown / Broken Over-FusedPanel looked ok.
________________________________________________________________________________________________________________
CIRCUIT WIRE Improper DAMAGED—NO Aluminum Copper Copper Clad OtherNon-Metallic Sheathed Armoured Cable Knob & Tube Double Tapping Spliced Corrosion Scorched
GROUNDING Concealed Ground Rod Water MainImproper Connection / Installation Corrosion Unsecured
The integrity of the electrical system ground cannot be verified by a visual inspection.
BONDING Concealed Water Pipe Gas PipeImproper Connection / Installation Corrosion UnsercuredProvide bonding to gas lines to complete ground system._________________________________________________________________________________________________________________
BASEMENT / STRUCTURE
_______________________________________________________________________________________________________________LIMITATION Finished Clutter Obstruction Dry Weather / Drought Dry GroundVISUAL INSPECTION LIMITATIONS (basement)Inspection of the interior of the basement was limited or restricted due to the existing living conditions of the sellers. Storage of personal belongings, general debris and an excessively cluttered interior limited access to many areas restricting a complete unencumbered visual inspection. Inspection of the finished basement areas
10
was based on accessible and visible areas that the inspector could safely enter, observe and report on.________________________________________________________________________________________________________________FLOOR Crack Concrete Dirt DAMAGED—NO Carpet Ceramic Vinyl Wood Laminate 9” Tile
Basement structure conditions determined by representative amount as viewed in furnace area. Approximately 5% of components visible.
________________________________________________________________________________________________________________
WALL Concrete Block Brick Stone PWF / Wood DAMAGED—NO Mildew / Mold Moisture Stains Effervescence Crack Concealed
Seal minor settlement cracks in the wall.__________________________________________________________________________________________CEILING Stain Unfinished DAMAGED—NO Drywall Plaster Wood Fixed Tile Drop Down Tile Insulated Uninsulated________________________________________________________________________________________________________________
WINDOW Binds Not Tested NOT TESTED Single / Double Hung Casement Awning Sliding Fixed Bay / BowThermal Aluminum Metal Vinyl / Vinyl Clad WoodDamaged Mildew / Mold Stain / Rot Repaint Recaulk _________________________________________________________________________________________DOOR Binds Damaged OPERATIONAL—YES Pocket Hinged Wood CompositeBasement exterior door looked good._______________________________________________________________________________________________________________
LIGHTING Minimal Unsecured OPERATIONAL—YES _______________________________________________________________________________________________________________
RECEPTACLE Damaged No Cover Unsecured OPERATIONAL—YES Reverse Polarity Install GFCI No Ground Open Ground_______________________________________________________________________________________________________________
CIRCUIT WIRE Concealed Unsecured Improper DAMAGED—NO _______________________________________________________________________________________________________________HEAT SOURCE None Thermostat Electric Air Register Convector Radiator Radiant_______________________________________________________________________________________________________________BASEMENT STAIRWAY Unsecured DAMAGED—NO Carpet Vinyl Wood Worn Trip Hazard Low Headroom_______________________________________________________________________________________________________________
RAILING Unsecured DAMAGED—NO Metal Wood Incomplete None_______________________________________________________________________________________________________________
FLOOR JOIST Concealed DAMAGED—NO Unsecured Split Notched Stain Rot OtherInsulation installed between floor joists. Joists were manufactured I beams._______________________________________________________________________________________________________________
BRIDGING Concealed None DAMAGED—NO
11
Continuous X-Metal X-Wood Solid Wood _________________________________________________________________________________________SILL PLATE Concealed DAMAGED—NO Moisture Gasket Termite Shield Mildew / Mold Stain / Rot No Anchors_______________________________________________________________________________________________________________
BEAM Unsecured Concealed DAMAGED—NO Laminate Metal Wood Sag Notched / Bored Insufficient End Bearing
There is suppose to be a space between the main beam and the concrete wall. This is to help keep the
end of the beam from rotting. Normally it is about ½ inch. ______________________________________________________________________________________________________________POST On Slab Unsecured Concealed DAMAGED—NO Adjustable Brick Block Concrete Metal Wood ________________________________________________________________________________________________________________
BEARING WALL DAMAGED—NO Should be a space between the beam and foundation wall to help prevent rot at end of beam. ________________________________________________________________________________________________________________
COLD ROOM Improper Door NONEConcrete Brick Block Stone Parged Earth Floor Mildew / Mold Stain / Damp Crack________________________________________________________________________________________________________________
CRAWL SPACE No Access Limited Access NONE Vapor Barrier Insulated Insulation Upside Down Entered Looked InCrack Mildew / Mold Stain / Rot Damp Water Stains Sump PumpEarth Floor Concrete Moisture Barrier Required
PIPES / DUCTS Unsecured Leak Insulated UninsulatedVENTILATION Mechanical Blocked Required ________________________________________________________________________________________________________________
HEATING/COOLING/VENTILATION _______________________________________________________________________________________________________________DATA PLATE: Not Legible Model Weil McLain Btu Input N/A Est. Age 5 yrsLIMITATIONS: Clean-Out Does Not Open Oil / Propane Tank Not Visible System Operating in Heat / AC System Shut-Off / Inoperative Piping / Ducts Concealed Weather / Temperature________________________________________________________________________________________________________________SMOKE DETECTORS Basement 1st Floor 2nd Floor 3rd Floor Other
CO DETECTORS Basement 1st Floor 2nd Floor 3rd Floor Other
12
Recommend installing new Carbon Monoxide and Smoke detectors in the home where recommended or required by manufacturer or local regulations. Provide regular testing and maintenance to ensure proper operation. It is common for manufacturers to recommend replacing CO detectors every 5-7 years and smoke alarms every 7-10 years and manufacturer recommendations should be used as a guide.
________________________________________________________________________________________________________________
THERMOSTAT / HUMIDISTAT Unsecured OPERATIONAL—YES
LOCATION First and second floor, Garage and masterbedroom Programmable ___________________________________________________________________________________________________FUEL SOURCE Gas Oil Wood / Pellet Electric
HEAT TYPE Convertor Forced Air Radiator
BURNER TYPE Conventional Mid-Efficiency High-Efficiency________________________________________________________________________________________________________________
HEATING SYSTEM Advise Service / Repair Contract OPERATIONAL—YES
AIR REQUIREMENTS Internal External Inadequate
VENTING Flue Sidewall Metal PlasticImproper Rises Unsecured Corrosion SootLIFE EXPECTANCY Typical Middle End Exceeded
This is a gas fired, cast iron unit, 4 zone hybrid hot air heating system.System was working well at time of inspection.Advise Annual Preventive maintenance agreement from a local contactor._________________________________________________________________________________________________________________HOT WATER (w) / STEAM (s) DAMAGED—NO BOILER CASE (w) Deterioration Corrosion Leak OK
Pumps looked ok.
CIRCULATING PUMP (w) Inoperative Corrosion Noisy OKAQUASTAT (w) Missing Corrosion Unsecured OK
13
BACK FLOW PREVENTOR Missing Corrosion Leak OKPRESSURE REDUCER (w) Missing Corrosion Leak OKEXPANSION TANK Location OK Drain Tank Open Closed Diaphragm Waterlogged Unsecured Corrosion LeakPIPING (w/s) Deterioration Corrosion Leak OKPRESSURE RELIEF VALVE Missing Corrosion Leak OKSITE GLASS (s) Missing Corrosion Low Water N/ALOW WATER CUTOFF (s) Missing Corrosion Leak N/APRESSURE CONTROLLER (s) Missing Corrosion Leak N/A________________________________________________________________________________________________________________
GAS BURNER Not Checked OPERATIONAL—YES
BURNER Corrosion Advise Adjustment
IGNITION Electronic Pilot & ThermocoupleHEAT SHIELD Missing Corrosion Soot
PROPANE TANK / PIPING Unsecured Corrosion Kink Leak ________________________________________________________________________________________________________________MOTOR / BLOWER Direct Drive Noisy Other
3 Air handlers. They worked ok.FAN BELT Loose / Worn Misalign Other
FILTERS Electronic Disposable Permanent Dirty Missing Inoperable Undersized DamagedDUCT / JOINT / HOUSING Unsecured Corrosion Kink Leak Uninsulated
Fixed pinched duct in basement ceiling.Return air filters should be changed monthly during cooling season. Budget to have ductwork cleaned every two years. _______________________________________________________________________________________________________________AC / HEAT PUMP Not Checked Evaporative Central Geo-Thermo Air Through Wall Damaged Fins Corrosion Noisy Loose Unsecured Not Level DirtyTEMP. DIFFERENTIAL Supply Air Return Air
14
FUEL SOURCE Unknown Electric Gas
CONDENSATION LINE Improper Drain Corrosion Leak
REFRIGERANT LINE Unsecured Not Insulated Leak ► Outdoor temperature prevented testing of the a/c system.► Testing A/C unit during low outdoor temperatures can cause system failure. Determine function prior to closing or cooling season.Three A/C zones.One air handler in basement, two in the attic space. Units looked ok.________________________________________________________________________________________________________________
PLUMBING COMPONENTS
_______________________________________________________________________________________________________________LIMITATION Finished Basement Private / Water Shut Off Private System Other________________________________________________________________________________________________________________
PUBLIC SUPPLY Concealed FUNCTIONAL Lead Galvanized Plastic Copper
Main water shutoff valve.SHUT-OFF VALVE Location BASEMENT –By air handler
15
Not Tested Corrosion Leak
Water flow was acceptable at time of inspection.________________________________________________________________________________________________________________
PRIVATE SUPPLY Concealed N/ASHUT-OFF VALVE LocationNot Tested Corrosion LeakWELL PUMP Submersible Jet Other Short Cycle Corrosion Leak Advise Well Water Quality / Recovery TestSTORAGE TANK No Air Valve Corrosion LeakWATER PRESSURE Low Typical HighWATER QUALITY Discoloration Debris Odor Test Declined Advise Water Quality Test________________________________________________________________________________________________________________HOSS BIBB Not Checked Water Supply Off FUNCTIONAL Frost Free Anti-Siphon Shut Off Valve Recaulk Unsecured Corrosion Leak________________________________________________________________________________________________________________
DISTRIBUTION PIPING Concealed DAMAGED—NO Lead Galvanized Plastic Copper Dissimilar Metals Unsecured Corrosion Leak
Water pipes were insulated and looked ok.CROSS CONNECTION Kitchen Laundry Hose Bibb________________________________________________________________________________________________________________
WASTE DRAINAGE Concealed DAMAGED—NO Galvanized / Steel Cast Iron Plastic CopperOdor Unsecured Corrosion Leak Advise Cesspool Tank Checked / PumpedFLOOR DRAIN None Backed-Up No Water No Trap
House is connected to property cesspool tank, located in front yard. Condition of buried lines and cesspool not covered by our agreement.________________________________________________________________________________________________________________
SEWAGE PUMP Not Checked Improperly Sealed Cover No Cover FUNCTIONAL ________________________________________________________________________________________________________________
VENT STACK / PIPING Concealed DAMAGED—NO Galvanized / Steel Cast Iron Plastic CopperUndersized Unsecured Corrosion Leak
MAIN CLEANOUT Concealed DAMAGED—NO
Improper Plug LOCATION BASEMENT WALL_______________________________________________________________________________________________________________HOT WATER TANK Hybrid Heating DAMAGED—NO Power-Vented Own Rent Est. Capacity 50 Gas / Propane Oil Wood / Coal ElectricDirty Rusty Odor Unsecured Corrosion Leak LIFE EXPECTANCY Typical Middle End ExceededRELIEF VALVE No Test Lever Corrosion Leak Other OKDISCHARGE TUBE Undersized Discharge Missing OKBrand: Weil McLainAGE: 5 yearsStorage Tank Unit appears in sound condition________________________________________________________________________________________________________________
16
WASHER Make NONE INSTALLED OPERATIONAL—YES
DRYER Make NONE INSTALLED OPERATIONAL—YES
DRYER VENT Unsecured INSTALLED—YES With Other Exhaust To Crawlspace To Attic To Exterior Plastic Duct
Clean exhaust vent periodically, depending on use, but at least every 2 years, or when installing your dryer in a new location. Disconnect vent from the dryer and clean one section at a time until you reach the exhaust hood. To clean out lint, use the hose attachment on your vacuum, or a pole or wire with a feather duster or rag attached. Be sure the flapper on the outside end of vent moves freely. When cleaning is complete, be sure to follow the Installation Instructions supplied with your dryer for final product check." ________________________________________________________________________________________________________________
TUB / FAUCET Unsecured N/A Plastic Other Slow Drain Corrosion Leak________________________________________________________________________________________________________________
TRAP /DRAIN AMAGED—Unsecured N/A Improper Trap Slow Drain Corrosion Leak
________________________________________________________________________________________________________________
GAS FIREPLACE
_______________________________________________________________________________________________________________TYPE Built-In Free Standing Gas Insert Wood Insert Metal Liner Firebrick External Air Supply________________________________________________________________________________________________________________
FIREPLACE FRONT Soot Stain DAMAGED—NO Brick Ceramic Marble Stone_______________________________________________________________________________________________________________HEARTH Raised None DAMAGED—N/A ________________________________________________________________________________________________________________
DOOR / SCREEN None FUNCTIONAL---N/A Binds Glass Metal Mesh
Poor Fit Unsecured Corrosion CrackDoor is seal closed on gas unit.________________________________________________________________________________________________________________
FIREBOX Fan Not Checked DAMAGED—NO
Draw of the fireplace was not tested and could not be determined at the inspection. ________________________________________________________________________________________________________________DAMPER None OPERATIONAL—YES Sticks Unsecured Corrosion Creosote________________________________________________________________________________________________________________
GAS INSERT Fan Not Tested OPERATIONAL—YES ________________________________________________________________________________________________________________
WOOD / PELLET STOVE Not Tested N/ASoot Suspect Installation Certification Not Apparent ________________________________________________________________________________________________________________CHIMNEY FLUE Not Checked NOT VISIBLE Soot Unsecured Improper Advise Inspection / Sweeping
17
2.5 BATHROOMS _______________________________________________________________________________________________________________LOCATIONS Basement 1st Floor 2nd Floor 3rd Floor Other________________________________________________________________________________________________________________WATER FLOW Normal Suspect Low________________________________________________________________________________________________________________
FLOOR Worn Crack Stain DAMAGED—NOCarpet Vinyl Wood Laminate Ceramic________________________________________________________________________________________________________________
WALL Patched Unfinished DAMAGED—NO Drywall / Plaster Brick / Block / Stone Wood Wallpaper Ceramic________________________________________________________________________________________________________________
CEILING Patched Unfinished DAMAGED—NO Drywall / Plaster Drop In Tile Fixed Tile Wood________________________________________________________________________________________________________________
WINDOW Binds Damaged DAMAGED—NO Single / Double Hung Casement Awning Sliding Fixed Bay / BowThermo Aluminum Metal Vinyl Vinyl Clad WoodDamaged Mildew / Mold Stain Rot Repaint________________________________________________________________________________________________________________DOOR Binds Damaged OPERATIONAL—YES Pocket Bi-Fold Hinged Wood Composite________________________________________________________________________________________________________________
LIGHTING None Unsecured OPERATIONAL—YES ________________________________________________________________________________________________________________
RECEPTACLE Damaged No Cover OPERATIONAL—YES Reverse Polarity Install GFCI Receptacle No Ground Open Ground________________________________________________________________________________________________________________EXHAUST FAN OPERATIONAL—YES ________________________________________________________________________________________________________________
SINK Worn Chipped Scratch DAMAGED—NO _______________________________________________________________________________________________________________
18
FAUCET No Shut-Off DAMAGED—NO _______________________________________________________________________________________________________________TRAP / DRAIN Unsecured DAMAGED—NO Improper Trap S-Trap Slow Drain Corrosion Leak Patched_______________________________________________________________________________________________________________VANITY Worn Unsecured DAMAGED—NO Laminate Plywood Wood Metal_______________________________________________________________________________________________________________COUNTER Worn Unsecured DAMAGED—NO Solid Surface Marble Granite Laminate CeramicRegrout Recaulk Mildew Stain Scratch _______________________________________________________________________________________________________________TOILET No Shut-Off DAMAGED—NO Tank Loose Unsecured Crack Leak _______________________________________________________________________________________________________________TUB / ENCLOSURE Unsecured DAMAGED—NO Ceramic Cult./Marble Fiberglass PlasticRegrout Recaulk Mildew Stain Crack Worn Stopper Not Working
Seal tile with a good tile sealer to help keep water from getting through the tile and grout joints._______________________________________________________________________________________________________________JETTED TUB Worked Ok DAMAGED—NO GFCI Protected Motor Access No Motor Access Corrosion Leak
Motor access was in laundry room ceiling._______________________________________________________________________________________________________________FAUCET / SHOWER HEAD Not Tested DAMAGED—NO Sticks Clogged Unsecured Corrosion Leak________________________________________________________________________________________________________________
SHOWER / ENCLOSURE Unsecured DAMAGED—NO Ceramic Cult./Marble Fiberglass PlasticRegrout Recaulk Mildew Stain Crack Worn
FAUCET / SHOWER HEAD Not Tested DAMAGED—NO Sticks Clogged Unsecured Corrosion Leak
Seal tile with a good tile sealer to help keep water from getting through the tile and grout joints________________________________________________________________________________________________________________HEAT SOURCE None Thermostat Electric Air Register Convector / Radiator Radiant
19
KITCHEN _________________________________________________________________________________________________________________LOCATIONS Basement 1st Floor 2nd Floor 3rd Floor Other_________________________________________________________________________________________________________________FLOOR Worn Crack Stain DAMAGED—NO Carpet Vinyl Wood Laminate Ceramic________________________________________________________________________________________________________________
WALL Patched Unfinished DAMAGED—NO Drywall / Plaster Brick / Block / Stone Wood Wallpaper Ceramic________________________________________________________________________________________________________________
CEILING Patched Unfinished DAMAGED—NO Drywall / Plaster Drop In Tile Fixed Tile Wood________________________________________________________________________________________________________________
WINDOW Binds Damaged DAMAGED—NO Single / Double Hung Casement Awning Sliding Fixed Bay / BowThermo Aluminum Metal Vinyl Vinyl Clad WoodDamaged Mildew / Mold Stain Rot Repaint________________________________________________________________________________________________________________PATIO DOOR Binds Damaged OPERATIONAL Metal / Vinyl Wood Hinged Sliding ________________________________________________________________________________________________________________LIGHTING None Unsecured OPERATIONAL—YES
RECEPTACLE Damaged No Cover OPERATIONAL—YES Reverse Polarity Install GFCI Receptacle No Ground Open Ground________________________________________________________________________________________________________________
SINK Worn Chipped Scratch DAMAGED—NO _______________________________________________________________________________________________________________FAUCET No Shut-Off DAMAGED—NO _______________________________________________________________________________________________________________TRAP / DRAIN Unsecured DAMAGED—NO Improper Trap S-Trap Slow Drain Corrosion Leak Patched________________________________________________________________________________________________________________
COUNTER Unsecured DAMAGED—NO Ceramic Marble / Granite Laminate Solid SurfaceRegrout / Recaulk Mildew / Stain Scratch Worn
CABINETS Unsecured Worn DAMAGED—NO Plywood Wood Laminate MetalMissing / Loose Hardware Mildew / Stain Scratch Other
20
_________________________________________________________________________________________________________________
RANGE HOOD Cooktop Exhaust DAMAGED—NO Corrosion No Exhaust No Light Noisy
EXHAUST VENT Unsecured Ductless Concealed OPERATIONAL—YES With Other Exhaust To Attic Improper To ExteriorFILTER None Unsecured Damaged Greasy_________________________________________________________________________________________________________________MAJOR APPLIANCES (Built In)DISHWASHER OPERATIONAL—YES STOVE / OVEN / RANGE OPERATIONAL—YES REFRIGERATOR OPERATIONAL—YES MICROWAVE N/A Tested On / Off Did Not Check All Functions / Full Cycle_________________________________________________________________________________________________________________HEAT SOURCE None Thermostat Electric Air Register Convector / Radiator Radiant
FOYER / HALLWAY / STAIRWAY
________________________________________________________________________________________________________________FLOOR Worn Crack Stain DAMAGED—NO Carpet Vinyl Wood Laminate Ceramic________________________________________________________________________________________________________________
WALL Patched Unfinished DAMAGED—NO Drywall / Plaster Brick / Block / Stone Wood Wallpaper Ceramic________________________________________________________________________________________________________________
CEILING Patched Unfinished DAMAGED—NO Drywall / Plaster Drop In Tile Fixed Tile Wood________________________________________________________________________________________________________________
WINDOW Binds Damaged DAMAGED—NO Single / Double Hung Casement Awning Sliding Fixed Bay / BowThermo Aluminum Metal Vinyl Vinyl Clad WoodDamaged Mildew / Mold Stain Rot Repaint________________________________________________________________________________________________________________LIGHTING None Unsecured OPERATIONAL—YES
CEILING FAN None Unsecured N/A
RECEPTACLE Damaged No Cover N/A Reverse Polarity Install GFCI Receptacle No Ground Open Ground________________________________________________________________________________________________________________CLOSET / DOOR Binds Damaged DAMAGED—NO Light Pocket / Bi-Fold Hinged Sliding________________________________________________________________________________________________________________
STAIRWAY Unsecured DAMAGED—NO Carpet Vinyl Wood Worn Trip Hazard
RAILING Unsecured DAMAGED—NO Metal Wood Incomplete None_______________________________________________________________________________________________________________FRONT DOOR Damaged DAMAGED—NO Binds Metal Clad Wood Dead BoltReplace Sill / Trim Weather Seal Split / Dent Worn
SIDELIGHT Loose Crack / Stain DAMAGED—NO _______________________________________________________________________________________________________________
21
INTERIOR ROOM(S)
INTERIOR GENERAL COMMENTS
The interior consisting of the bedrooms, living and dining rooms, and other common spaces were similar in make up and materials and all comments will be listed in this section. Specific conditions and remarks will identify the individual room in question (ie; Bedroom, Living Room ) and noted conditions should such exist at the time of the inspection. The comments are intended to give an overview and highlight areas that may require maintenance, improvements, repairs or updating:_________________________________________________________________________________________________________________FLOOR Worn Crack Stain DAMAGED—NO Carpet Vinyl Wood Laminate Ceramic________________________________________________________________________________________________________________
WALL Patched Unfinished DAMAGED—NO Drywall / Plaster Brick / Block / Stone Wood Wallpaper Ceramic________________________________________________________________________________________________________________
CEILING Patched Unfinished DAMAGED—NO Drywall / Plaster Drop In Tile Fixed Tile Wood________________________________________________________________________________________________________________
WINDOW Binds Damaged DAMAGED—NO Single / Double Hung Casement Awning Sliding Fixed Bay / BowThermo Aluminum Metal Vinyl Vinyl Clad WoodDamaged Mildew / Mold Stain Rot Repaint________________________________________________________________________________________________________________
DOORS Binds Damaged DAMAGED—NO Pocket Bi-Fold Hinged Wood Composite________________________________________________________________________________________________________________PATIO DOORS Binds Damaged DAMAGED—NO Metal / Vinyl Wood Hinged Sliding________________________________________________________________________________________________________________CLOSET DOORS Binds Damaged DAMAGED—NO Metal / Vinyl Wood Hinged Sliding________________________________________________________________________________________________________________LIGHTING None Unsecured OK DAMAGED—NO
CEILING FAN None Unsecured OK DAMAGED—NO RECEPTACLE Damaged No Cover OK DAMAGED—NO Reverse Polarity Install GFCI Receptacle No Ground Open Ground_________________________________________________________________________________________________________________
FRONT DOOR Damaged DAMAGED—NO Binds Metal Clad Wood Dead BoltReplace Sill / Trim Weather Seal Split / Dent Worn
SIDELIGHT Loose Crack / Stain DAMAGED—NO _________________________________________________________________________________________________________________HEAT SOURCE None Thermostat Electric Air Register Convector / Radiator Radiant
22
ADDITIONAL COMMENTS
____________________________________________________________________________________
General Comments
This inspection is performed to the Standards of Practice of New York State and is visual in nature, and does not address building code compliance issues which are the purview of municipal building inspectors.
Overall House was in good condition.Main areas of concern were:
Some future regrading will be needed as earth settles around the foundation. Add spindles to handrail on front steps. Clean window wells and make deeper. Add second handrail on wall for garage steps. Fix pinched duct in ceiling in basement. May need fresh air vent for fireplace. Add space between main beam and concrete wall.
LimitationsChimney - The interior of chimneys and their flue liners are not visible on our visual inspection. You are advised to obtain the services of a qualified chimney sweeper or other qualified personnel to perform a complete inspection and tune up of your heating appliances prior to use.
Circuit Sizing - The Inspector is required to address the compatibility of conductors and overcurrent devices. In some instances, general trade procedures include over-sizing overcurrent devices to guard against nuisance (e.g. air conditioning units, dryers). The Inspector is not required to evaluate such general trade procedures, but to inform you of incompatibility.
23
____________________________________________________________________________________________________
Supplementary Comments
Not all receptacles/outlets tested.Not all windows or doors may have been checked.
Wallpaper and/or fresh paint might conceal cracks, stains and possible leaks.
Stucco, siding or shingle exterior makes it difficult to assess the complete structure of the house.
Decks, obstructions and weather can limit accessibility and/or conceal deficiencies around the outside of the house.
It is very important that water & runoff drain away from foundations to minimize chance of water leakage into the basement, as cracks in foundation walls are common. Make sure the ground, patios and walkways slope away from the house for the first six feet.
Seal, caulk, repoint and/or repair cracks / gaps around the house (i.e. windows, sills, bricks & siding).
It is important that water from eve troughs drains well away from house - at least 6 feet away from wall. Also it is usually better to reposition downspouts to drain water above ground and away from house, then cap drains.
Make sure that eaves troughs remain fastened securely, gutters are kept clean seasonally from leaves & debris and leaks are sealed. Also, ensure that tree branches are not rubbing against eve troughs and roof.
Ensure roof flashing remains fastened, lays flat and gaps / cracks are caulked & sealed promptly to prevent leaks.
Monitor the roof and attic on a seasonal basis for leaks and (wind) damage. Repair as soon as possible.
Monitor siding and/or shingle exterior regularly for looseness, (wind) damage and repair and/or fasten as necessary.
Basement walls were checked visually and with moisture sensor. Dampness was not detected at this time.
Ensure that any cracks / gaps in bathroom or kitchen ceramic tiles are grouted, caulked and sealed to prevent leaks.
24
Keep humidity low to prevent condensation, stains, mildew forming on windows & walls (<25% = -20 C; <40% = 0 C)
Ceramic floor tiles, especially larger ones, can crack unexpectantly or become loose - repair as required.
25
Top Related