® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
GRX-CI-PRG Control Interfaces
369363 Rev. B 1 06.02.11
GRX-CI-PRG Programming Control Interface
Description
•IntegratesaGRAFIKEye®lightingcontrolsystemwithaPCorotherdigitalequipmentthatsupportsRS232andTCP/IPcommunication.
•ProvidesabasicserialstringcommandsetthatallowsaPCtomonitorandcontrollighting.
•Built-inastronomictimeclockprovidesabilitytoschedulelightingevents.Example:Lobbylightsturnontoscene1at7:30a.m.or10minutesaftersunrise.
•EnablesuseofaPCtosetupGRX-3500andGRX-4500controlunits.
•Comeswitheasy-to-use,“point-and-click”Windows®-compatibleLIAISONTMsoftwareforschedulingtheastronomictimeclockandusingtheprogrammerInterface.
•FunctionalityisselectedusingDIPswitches.•OperateswithorwithoutaPCconnected.•MaybeprogrammedtocontrolanycombinationofonetoeightGRAFIKEye®3000or4000seriescontrolunits.
•GRX-3100,GRX-4100,andGXI-3100controlunitsmayutilizetheastronomictimeclockfunctionoftheGRX-CI-PRG.
•GRX-3500,GRX-4500,andGXI-3500controlunitsmayutilizeallfunctionsoftheGRX-CI-PRG.
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
GRX-CI-PRG Control Interfaces
369363 Rev. B 2 06.02.11
Specifications
Standards
•CaliforniaEnergyCommission(CEC)Listed
Power
•IECPELV/NEC®Class2•OperatingVoltage:12V 125mA
24V 65mA
Environment
•32to104°F(0to40°C).•Relativehumiditylessthan90%non-condensing.
Basic Command Set
•Monitoring:Sceneselectionandscenestatusupdates.
•Control:Sceneselection,scenelockout,sequencing,zonelockout,zoneraise/lower.
Astronomic Timeclock
•Allowslightingchangestooccurautomaticallybasedontimeofdayand/ordayofweek/month,aswellasrelativetosunriseandsunset.
•Supportsfourscheduleswith60lightingeventsperscheduleandoneSuperSequence.
•Allowsusertostart,pause,andstopschedulesfromaPCoraWallstation.
•Providescommandstosetandmonitorthetimeclock’stime,date,anddayofweek,andreportsunriseandsunset.
•Ifalossofpoweroccurs,theprogrammedschedulesandthetimeofdaywillberetainedforaminimumof10years.
Programmer Interface
PermitscompletesetupofthefollowingonGRX-3500,GRX-4500,orGXI-3500controlunitsviaanIBM®-compatiblePC:
•Scenes,includinglightlevelsin1%incrementsandfadetimes.
•Loadtypesettings.•Tamper-proofprotectionofscenes.•Assignmentofcommunicationbetweencontrolunitsandwallstations.
•Dimmerpanelzoneandloadassignment
AllowsaWindows®-compatiblePCtoqueryGRX-3500,GRX-4500,andGXI-3500controlunitsfortheirsetup,includingtypeofcontrolunitandnumberofzones.
LIAISONTM Software
•ControloverTCP/IPrequiresLIAISONTMversion4.0orlater.
•AllowsuseofaPCtocreatetimeclockschedulesforallGRX-3000,GRX-4000,andGXI-3000seriescontrolunits.
•AllowsuseofaPCtocreatesetupsforGRX-3500,GRX-4500,andGXI-3500controlunits.
•ProvidesdownloadingofschedulesandsetupstoGRX-CI-PRGinterfaceandcontrolunits.
•WorksonanyPCoperatingwithWindows®95Windows®NT4.0,XP,orlater(excludingWindows®VistaandWindows®7).
•SuppliedbyLutron.Updatesareavailableonlineatwww.lutron.com
System Communications and Capacity
•IECPELV/NEC®Class2wiringconnectsGRX-CI-PRGinterfacetocontrolunitsandothercomponents.
•OneGRX-CI-PRGInterfaceperGRAFIKEye®3000or4000orGXI-3000system.Automaticallyoccupieswallstationaddress16.
•50ft(15m)maximumfromGRX-CI-PRGInterfacetoPCorotherRS232source.
•328ft(100m)maximumfromGRX-CI-PRGInterfacetoPCorotherEthernetsource.
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
GRX-CI-PRG Control Interfaces
369363 Rev. B 3 06.02.11
Functions
DIP Switch Function
When set to ON
When set to OFF
1 ZoneLockRetain Ifpowergoesout,lockedzonesstaylockedwhenpowerreturns.
Powercyclingunlockslockedzones.
2 SceneLockRetain Ifpowergoesout,lockedscenesstaylockedwhenpowerreturns.
Powercyclingunlockslockedscenes.
3 SequenceRetain Ifpowergoesout,sequencingresumeswhenpowerreturns.
Powercyclingstopssequencing.
4 SequencingSceneRange Sequencingloopsthroughscenes5to16.
Sequencingloopsthroughscenes1to4.
5 NotUsed DonotsettoOn. Factorypreset;donotchange.
6 ButtonFeedback Interfacereportscontrolunitandwallstationbuttonpresses.
Noreportingonbuttonpresses.
7 SceneStatus Interfacereportsscenechanges. Noreportingonscenechanges.
8 AstronomicTimeclockSchedules
Enablesinternaltimeclock. Disablesinternaltimeclock.
1 2 3 4 5 6 7 8
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
GRX-CI-PRG Control Interfaces
369363 Rev. B 4 06.02.11
Dimensions2.47in
(62.7mm)
3.75in(95.3mm)
4.26in(108.2mm)
5.26in(133.6mm)
1.06in(26.9mm)
Mountingholes
Mounting
1.Mountthecontrolinterfacedirectlyonawall,asshownintheMountingDiagram,usingscrews(notincluded).Whenmounting,providesufficientspaceforconnectingcables.
TheunitcanalsobeplacedintheLUT-19AV-1UAVrackusingthescrewsprovidedwiththeunit.TheLUT-19AV-1Uwillholduptofourunits.
Ifconduitisdesiredforwiring,theLUT-5x10-ENCcanbeusedtomountoneunit.
2.Strip4in(10mm)ofinsulationfromwires.Eachdatalinkterminalwillacceptuptotwo18AWG(1.0mm2)wires.
3.ConnectwiringasshownintheWiringDiagram(nextpage).LED1lightscontinuously(Power)andLED7blinksrapidly(DataLinkRX)whentheIECPELV/NEC®Class2DataLinkisinstalledcorrectly.
LUT-19AV-1U
WireStripLength
4in(10mm)
5.26
4.263.75
2.50
1.06
ControlInterface
Wall
Mounting Diagrams
LUT-5x10-ENC
0.25(6.4)
0.34(8.6)dia.
0.18(4.6)dia.
0.18(4.6)dia.
#6or#8(M3orM4)screwrecommended(notincluded)
Mounting Hole DetailDimensions:in(mm)
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
GRX-CI-PRG Control Interfaces
369363 Rev. B 5 06.02.11
RS232 Link Wiring
1 2 3 4 5 6 71 2 3 4 5 6 7 8
RJ45jack:Ethernetlink(toPCorA/Vequipment)
Ethernetlink/
activity
Ethernetspeed
DataLink(tocontrolunits,processors,andwallstations)
DIPswitches
CAT5Cable:maximum328ft(100m)
ToPCorAVequipment.ForEthernetlink,useaCAT5cabletoconnecttoauxiliaryequipment.TheEthernetlinkLEDwilllightcontinuouslywhenlinkispresentandwillflashwhenthereislinkactivity.AdditionalEthernetnetworkequipmentandcablesprovidedbyothers.
12or24V tooutlet(withoptionaltransformer).Donotwireterminal2onDataLinkwhenusingoptionaltransformer.TopowerseparatelyfromtheDataLink,orderthefollowingLutrontransformermodelnumbers:120V :T120-15DC-9-BL240V :TE240-15DC-9-BL240V (UK):TU240-15DC-9-BL
RS232Cable:maximum50ft(15m)
COM
TxD
RxD
ToPCorAVequipment:UseastandardDB9maletoDB9femalecable,orfollowthechartbelow.
RS232PinConnectWiring
TypicalPCor PinonRS232Interface A/Vequipment 9-pincableCommon Com 5Transmit TxD 3Receive RxD 2
LED1:PowerLED2:EthernetlinkLED3:UnusedLED4:RS232linkTXLED5:RS232linkRXLED6:DatalinkTXLED7:DatalinkRX
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
GRX-CI-PRG Control Interfaces
369363 Rev. B 6 06.02.11
IEC PELV/NEC® Class 2 Terminal Connections•Installinaccordancewithallapplicableregulations.•Donotconnectlinevoltage/mainspowertodevice.•ThiscontrolcanuseIECPELV/NEC®Class2wiringmethods.Checkwithyourlocalelectricalinspectorforcompliancewithnationalandlocalcodesandwiringpractices.
•Makedaisy-chainconnectionstotheIECPELV/NEC®Class2datalinkterminalsontheendofthecontrolinterface.
•DonotuseT-taps.Runallwiresinandoutoftheterminalblock.•Eachterminalacceptsuptotwo18AWG(1.0mm2)wires.
ZONE 6ZONE 4
HOT/LIVESSA
CU WIRE ONLY
ZONE 2ZONE 3ZONE 5
NEUTRAL
ZONE 1
CLASS 21 2 3 4
USAClass 2IECPELV
4 3 2 1
Toadditionalwallstations/controlinterfaces(16maximum;3poweredfromoneGRAFIKEye® controlunitwithoutexternal12V powersupply;GRX-CI-PRGcountsastwodevicestowardthemaximumofthreeconnectedtooneGRAFIKEye®3000controlunitwhennotusingoptionaltransformer)
Control Interface Wiring: GRX-3000 or GXI-3000 Control Unit
RearViewofGRAFIKEye®ControlUnit(GRX-3106shown)
UseLutronCableGRX-CBL-346Sorequivalent
DataLink
DataLink:
4:MUX
3:MUX
Oneshielded,twistedpair18AWG(1.0mm2)fordatalink(terminals3and4)
IECPELV/NEC®Class2Powerwiring:
2:12V Power1:Common
Two18AWG(1.0mm2)conductorsforCommon(terminal1)and12V (terminal2)
4 3 2 1
IECPELV/NEC®Class2Powerwiring:
1:Common2:24V Power
(2)18AWG(1.0mm2)pigtails,6in(15mm)maximumlengthDonotwirePin2whenusingoptionaltransformer.
D:Drain/Shield
(2)12AWG(2.5mm2)
(2)12AWG(2.5mm2)
DataLink:(1)shielded,twistedpair18AWG(1.0mm2)
4:MUX
3:MUX
Control Interface Wiring: GRX-4000 Control Unit
Note:12AWG(2.5mm2)conductorsforCommon(terminal1)and24V power(terminal2)willnotfitinterminals;use18AWG(1.0mm2)pigtails(<6in/15mm).
Note: Donotconnectdrain/shieldtoground(earth)orwallstation/controlinterfaces.Connectthebaredrainwiresandcutofftheoutsideshield.
UseLutronCableGRX-CBL-46L
ToOutlet(withoptionaltransformer).DonotwirePin2whenusingtransformer.
B: G: 1A: C: D: E: F: H: 2I: 3J: 4K: 5L: 6