EVA-07S Single-phase AC charging equipment
User Manual
Lakes Court, Lancaster Business Park, Newborough Road,Needwood, Burton Upon Trent, Staffordshire DE13 9PD
www.projectev.co.uk
Project EV
Menu
1. Product overview....................1
2. Features...........................1
3. Specification........................2
4. Operation..........................3
5. .......6
7. Troubleshooting.....................18
8. Packaging list.......................19
9. Annex.............................20
System Parameter setting.......
6. Installation.........................11
Safe and Reliable
Reliable electrical and anti-thief protection, The IP65 degree allows for water and
dust proof and normal operation in harsh environment.
System Integration
Integrate all functions, such as charging control, HMI, safety protection, metering
into one system, simple structure but reliable operation.
Easy to useuser-friendly HMI, simple and easy to operate.
Compact design
I The compact design makes it suitable for area with limited usable land, either wall
or poll mounted.
Multiple communication types
Imultiple communication ports including Ethernet port, WiFi, 3/4G to provide reliable
connection to backend server.
Metering and Billing
Integrated metering and billing system to provide precise metering and billing
function.
Resistant to moisture, mildew, salt-mist and rust
The comprehensive protection to harsh environment makes it capable to operate in
moisture and salt-mist condition.
1.Product overview
EV series product is a charging apparatus with user-friendly HMI and functions of
charging control, metering and communication. etc. specially designed for charging
EV batteries.
A
2.Features
Exquisite appearance
exquisite and simple exterior design
1 2
Model EVA-07S
Dimension(mm) 510*355*360(L*W*H)
Weight(kg) 8.5
Display LCD
Housing material Stainless steel &Tempered glass
Input
Nominal Voltage AC 230V
Nominal Current 32A
Output
Nominal Voltage AC 230V
Nominal Current 32A
IP Protection degree IP65
Operating temperature -20℃~+65℃
Humidity 5%~95%
Altitude ≤2000m
Frequency 50 Hz ±1Hz
Communication Ethernet, 3/4G ,WIFI
Payment RFID/APP
Standby power <8W
Standard IEC62196-2;IEC61851
Mounting type Wall or Poll mounted
Certificate CE
Protection features
Overvoltage 287.5V
Undervoltage 184V
Overcurrent 40A
Short-circuit Yes
Leakage current Type A 30mA + 6mA DC
Over temperature Yes
Lightning protection Type II
3.Specification
4
Standby status
The charging equipment will enter standby status after powering on, the following
interface will appear on the LCD,
Swipe card to start charging
Plug the charging gun into the vehicle inlet and swipe the card, the charging
equipment will freeze the credit of the card after recognizing it, the credit will be
unblocked after the charging. At the meantime, the charging equipment will show
the following interface with card ID and balance displayed.
3
4.Operation
Switch on the power to power cable, the Red and Green status indicator will flash to
initiate and start the control circuit. The charging equipment will successfully start
and be ready to use after the LED turns off.
At standby status, users can swipe card to check credit balance
This interface is same with the interface of balance checking at standby status..
During the charging
There will be electricity consumption, time and money spent showing on the display.The Green status indicator will lit continuously during the charging.
Swipe card again to stop charging
Re-swipe with the same card, the charging equipment will bill according to the
electricity consumption and release the locked charging gun, the billing interface will
appear on the display.
5 6
Charging complete without re-swiping card
Charging complete will change the display to the following interface indicating user
to swipe card to bill. The card will be frozen if leaving without re-swiping. The frozen
card can only be unlocked at this specific charging equipment by swiping or at
backend office where the card was issued.
Notification interface
The following notification interface will come out at fault status or when the
emergency button is pushed. Fault code will appear along with the Red status
indicator.
DANGER
Notice: The charging equipment will only return to normal operation on condition of the
following faults when, The grid voltage falls below upper limit by 5V at over voltage fault; The grid voltage rises above lower limit by 5V at under voltage fault; The casing temperature falls below upper limit by 5oC at over temperature fault. High temperature fault will result in half output power. Over temperature fault will
stop the charging.
5.System Parameter setting
Image Meaning
XX 00
XX 01
XX 10
XX 11
00XX
The network connection is via LAN cable(LAN/WAN)
The network connection is via WiFi
Reserved for future use
Case C, cabled version charger
The network connection is via 4G
DIP coding
The DIP switch has 4 bit, the farthest right bit is bit0. Position On corresponds to 1,
Off means 0.
DIP coding definition
Definition for last 2 bits
Definition for first 2bits
01XX
10XX
11XX
Case B, socket version charger
Reserved for future use
Reserved for future use
Introduction
There is an internal web server inside each charger, You can access the internal web
server via web browser on a PC that is connected to the charger using a network
cable for parameter setting.
The interface of the internal web browser is as below, hereinafter it is refered to as
parameter setting page.
7 8
The default IP address of the charger is 192.168.1.5. To access the parameter setting
page, you need to
1.First connect the charger to a computer via a network cable.
3.Open the web browser and type in http://192.168.1.5:8080 in the web browser
and click enter(8080 is port number), then the parameter setting page will come out.
2.Set the computer’s IP address to 192.168.1.x(x can be any value between 1 and
255 except for 5).
4.If you cannot get into the parameter setting page after several attempts, the
charger’s IP may have been set to other value, you can reset the charger to factory
setting and try again, the charger’s IP will be restored to 192.168.1.5 after the
factory reset.
Long press the below marked reset button until the charger reboots, then it will be
restored to factory setting.Please note that after factory setting, you need to reset charger ID, which can be
found on the label sticker on the left hand side of the charger.
10
Some key parameters:
Firmware Version Num: the charger’s firmware version
Charge ID(MaxLen 20): the charger’s ID, which can also be found on the label
sticker on the left hand side of the charger.Charger IP: the charger’s IP address, used to access the parameter setting pageDefault Gateway, Subnet Mask, Charger DNS only need to be set when the
charger uses network cable for server connection
Language Set(1,2,3): Set language of LCD
Max Current Set(7~32A): Set the maximum charging current
Charge Mode(Default 1:APP/RFID, 2:RFID, 3:Plug&Charge): Charger’s charging
mode. In Mode1, charger can start or stop by APP or RFID card;In mode2, charging start/stop can only be controlled by swiping RFID card; In mode3, Charging will start automatically after connecting car to the charger.
Server URL: Set the domain name or IP address of the server to be connected. The
domain name of Growatt server is “ws://charge.growatt.com:80/ocpp/ws”; IP
address is “ws://47.254.157.66:80/ocpp/ws”.WIFI SSID and WIFI Key are used for WiFi connection. Charging Rate: Set charging fee per unit of electricityDayTime, NightTime, Day-Price and Night-Price is used to set peak and off-peak
tarrif and period. If Charging Rate has been set, these peak and off-peak setting will
be invalid.
LCD Time: Set the charger’s time. If the charger has server connection, the time will
be synchronized with the server automatically.Max Limit Power, MeterValue Interval and PowerLimit Option is used to set
power adjustment function.Allow ChargingTime: Once set, charging can only be carried out within this period
unless the forced on/off button is pressed.4G Account, 4G Password and 4G APN is used for 4G connection..
9
Reset button of 7kW charger
Some key parameters:
12
Step2: hit the M8 interior expansion bolts into the drilled holes
Step3: unfold the packaging and take out all items
Step4: Mount and fix the bracket onto the wall,
7
Step 1: Drill on the wall according to the dimension below
6.Installation
11
13
Step6: The complete installation will be as below
6.1.Mounting on pole
Step1. Drill on the ground for pole standing,
Step2: Hit the expansion bolts into the drilled holes as shown below,
14
Step5: Hang the charging equipment on the mounting bracket
Step3. Take all the items out,
Step4. Mount the pole onto the expansion bolts in the ground and fix with the nuts,
Step5. Mount the cable holder,
15 16
Step6. Fix the charging equipment onto the top of the pole from the bottom and fix with the hex head screws. Then the installation is completed.
7.Simple troubleshooting
If fault happens, please first check the following table for simple troubleshooting. If
the fault is out of the list or the fault still persists after troubleshooting. Please
contact your seller for further assistance. Unqualified personnel are not allowed to
open the charging equipment or repair it!
Fault Countermeasures
Fault indicator lit Check if emergency button is pushed
No power Check if there is power going into the charging equipment;Check if the RCBO is tripped inside the charging equipment
Check if emergency button is pushed downNo output current
17 18
Fault code
Fault code Fault description
100Emergency button is pressed or broken.
No.
1
7
105
106
Over voltage
Under voltage
2
3
4
5
6
108
109
110
111
1000
Over current
Over temperature
RCD leakage protection
Rs485 fault
Other errors8
19
8.Packaging list
No. Name UnitQty Remark
1
2
3
4
pcs
pcs
pcs
pcs
1
1
1
1
Charging equipment
User manual
QC certificate
9.Annex
8.1 Electrical diagram
Fig8-1. 3-phase AC charging equipment main circuit
AC SPD
AC KM
INPUT
OUTPUTAC ChargeGun
Cable holder
DANGER
Notice:
1.Wiring and installation must be carried out by qualified personnel, phase
sequence cannot be connected incorrectly!
2.The PE wire should be grounded firmly!
3.No live working! The incoming power should be cut off before opening the
charging equipment.
4.Unqualified person is not allowed to open or repair!
20
Top Related