Goal : • Setup and monitor “chambers” with
resolution of < 200 m• Demonstrate System RedundancyTest Setup :• 1 SLM Line• 1 Transfer Line • 1 Transfer Plate• Analog Sensors (Temp, Proximity)Analysis :• 5000+ Events Taken• 1500+ Events Reconstructed
Conclusions are not final … … but we are
close !
Test of EMU ISR SystemJune-Sept 2000 at CERN ISR Tunnel
Assumptions :• Sensors et2, et3, and es10 are known• Transfer Plate definition is defined• Rotations of sensors are known within error limits of photogrammetry
Prototype Test SetupJune-Sept 2000 at CERN ISR Tunnel
Title:
Creator:ROOT Version2.24/04Preview:This EPS picture was not savedwith a preview included in it.Comment:This EPS picture will print to aPostScript printer, but not toother types of printers.
SLM Line (Laser 302) Results of COCOA Reconstruction for July/August and September Runs Using es10 as the Final Reference Sensor
Title:
Creator:ROOT Version2.24/04Preview:This EPS picture was not savedwith a preview included in it.Comment:This EPS picture will print to aPostScript printer, but not toother types of printers.
SLM Line (Laser 303) Results of COCOA Reconstruction for
July/August and September Runs Using es10 as the Final
Reference Sensor
COCOA Reconstruction Results(ISR Test Results – es10 Reference)
Title:
Creator:ROOT Version2.24/04Preview:This EPS picture was not savedwith a preview included in it.Comment:This EPS picture will print to aPostScript printer, but not toother types of printers.
Title:
Creator:ROOT Version2.24/04Preview:This EPS picture was not savedwith a preview included in it.Comment:This EPS picture will print to aPostScript printer, but not toother types of printers.
SLM Line (Laser 302) Results of COCOA Reconstruction for July/August and September Runs Using es9 as the Final Reference Sensor
SLM Line (Laser 303) Results of COCOA Reconstruction for July/August and September Runs Using es9 as the Final Reference Sensor
COCOA Reconstruction Results(ISR Test Results – es9 Reconstruction)
Title:
Creator:ROOT Version2.24/04Preview:This EPS picture was not savedwith a preview included in it.Comment:This EPS picture will print to aPostScript printer, but not toother types of printers.
Title:
Creator:ROOT Version2.24/04Preview:This EPS picture was not savedwith a preview included in it.Comment:This EPS picture will print to aPostScript printer, but not toother types of printers.
Sample September Laser 302 Results (1 sensor)
Sample September Laser 303 Results (1 sensor)
COCOA Reconstruction Results(ISR Test Results – es9 Reconstruction)
Note :• Large survey errors
• 60 m local 120 m global• ~ 220 m Systematic Errors• < 15 m Statistical Errors
General Conclusions : • 4 CCD measurements on
reference Sensors are critical• Reconstruction is roughly
independent of laser choice (within error)
• Reconstruction is independent of laser motions
COCOA Reconstruction ResultsGeneral Remarks
Distribution of raw CCD means in es4 during the July/August Run. Jump of 30 pixels = 420m
Title:
Creator:ROOT Version2.24/04Preview:This EPS picture was not savedwith a preview included in it.Comment:This EPS picture will print to aPostScript printer, but not toother types of printers.
Distribution of COCOA Reconstructed location of es4 in the ISR hall during the July/August Run. (y = 10 m, z = 8 m)
Conclusion : Shift in Laser not seen in Reconstruction
30 pixels
COCOA Reconstruction Results(Laser Independence)
COCOA Reconstruction ResultsThoughts on COCOA
• Comparison of COCOA Results to ‘Hand Calculations’– We have verified operation in simple
EMU type systems to < 100 m– We cannot verify in ISR EMU system
to <400 m (rotations, calibration errors, transfer plate errors)
• Evidence of COCOA Accuracy– Prediction of et3 dowel location direct
from PG agrees within 10 m from CERN PG group determination
– Prediction of et1-es1 separation on Transfer Plate within 30 m of CMM determination (full EMU simulation)
• Concerns– Convergence of fit to local minima
(false solutions)– Degenerate rotations possible
COCOA Reconstruction ResultsThe Bottom Line (March 2001)
• We can demonstrate reconstruction of sensor positions within 220 m of CERN PG
• We can make redundant measurements
• Real CMS Data Can Be Better Than March 2001 Results– 3 CCDs only on Reference Sensors
(4 CCDs improve results)– Calibration Errors larger than expected,
no calibration prior to installation (better results with better calibration)
– More Constraints on COCOA Fits (Calibrated X-Hair Laser, Inclinometer
Data on Transfer Plate)
Extra Slides
Title:
Creator:ROOT Version2.24/04Preview:This EPS picture was not savedwith a preview included in it.Comment:This EPS picture will print to aPostScript printer, but not toother types of printers.
Sample September Laser 302 Results (1 sensor)
Sample September Laser 303 Results (1 sensor)
COCOA Reconstruction Results (ISR Test Results)
FLAP takes raw data and finds centroid of chargedistribution in each CCD
Laser Instability : CDD centroids were found to‘jump’. Problem can be traced to laser diode.
COCOA Reconstruction Results(Laser Independence)
FLAP Fitting RoutinesCCD Peaks in es9 from laser 302 …
CCD Peaks in es9 from laser 303 taken immediately after laser 302 data…
Top Related