Download - GenReady Load Center and Transfer Switch Load Center.pdfFront Cover & Door. 43.25. Generator Utility. Transfer Operator. Neutral Equipment Ground. Bonding Connection. 14.875 14.38

Transcript
Page 1: GenReady Load Center and Transfer Switch Load Center.pdfFront Cover & Door. 43.25. Generator Utility. Transfer Operator. Neutral Equipment Ground. Bonding Connection. 14.875 14.38

• 200amp

• 40circuitcapacitywiththeuseoftandembreakers

• MultilistedforusewithSiemens,SquareDandGE1”breakers

• Dimensionsarethesameasastandard42-spacemainloadcenter

• UtilizesstandardSiemenscomponents

• Protectupto18circuits,upto30withtheuseoftandembreakers

• 10circuitsavailablefornon-protectedloads

• Circuitscaneasilybeshiftedfromprotectedtonon-protectedandviceversa

• ETLlistedforserviceequipmentandconsumersafety

• ModelsavailablewithorwithoutEZTransferOperator™factoryinstalled

• Singlepanelsarecompatiblewithgeneratorsratedupto125Amps/30kW

• MultipleGenReadyloadcenterscanbesupportedwithasinglegenerator

• FlushMountNEMA1EnclosureorNEMA3REnclosure

GENREADY™ LOAD CENTER FEATURES

DESCRIPTIONThe GenReady load center is a hybrid panel that operates as a normal load center and also allows for seamless integration of standby generators. It is available in a NEMA 1 configuration for indoor installations, or in a NEMA 3R configuration for outdoor applications. For installation flexibility, it is multi-listed for use with multiple breaker manufacturers.

EZ TRANSFER™ OPERATOR FEATURES• FactoryinstalledontheGenReadyAdvancedmodel.CanbeeasilyinstalledinthefieldontheGenReadyBasicwithavailablekit

• Allowsformanualorautomaticoperation

Please Note: The GenReady Panel is designed to be directly compatible with any Generac manufactured product. Use of another manufacturer’s generator may require the purchase and installation of additional sensing and control components.

Model 005448-2 (NEMA 1 Basic)Model 005449-2 (NEMA 1 Advanced)Model 005453-2 (NEMA 3R Basic)Model 005454-2 (NEMA 3R Advanced)Model 005447-0 (EZ Transfer Operator™)

GENERAC® TRANSFER SWITCH™

GenReady® Load Center and Transfer Switch

®

Page 2: GenReady Load Center and Transfer Switch Load Center.pdfFront Cover & Door. 43.25. Generator Utility. Transfer Operator. Neutral Equipment Ground. Bonding Connection. 14.875 14.38

PRODUCT OPTIONS

NEMA1GenReadyBasicLoadCenter

Model Number 5448

NEMA1GenReadyAdvancedLoadCenterwithEZ

TransferOperator™Model Number 5449

NEMA3RGenReadyAdvancedLoadCenterwithEZ

TransferOperator™Model Number 5454

EZTransferOperator™FieldInstallationKit

Model Number 5447

Includes:

•125ACircuitBreaker

•125ALowerPanelCircuitSwitch

•200AMainCircuitBreaker

IncludesGenReadyBasicplus:

•EZTransferOperator™

•125ALowerPanel,GeneratorCircuitSwitch

•15ADoublePoleBreakerforSensingCircuit

•Plusallothercomponentsfoundinthefieldinstallationkit.

IncludesGenReadyBasicplus:

•EZTransferOperator™

•125ALowerPanel,GeneratorCircuitSwitch

•15ADoublePoleBreakerforSensingCircuit

•Plusallothercomponentsfoundinthefieldinstallationkit.

TransferOperatorFieldInstallationKitIncludes:

•TransferOperator

•15ADoublePoleBreakerforGeneratorSensingCircuit

•125ALowerPanel,GeneratorCircuitSwitch

•HoldDownBracket

•InterlockBar

•MountingHardware

•Decals

•InstallationGuide

GenReady™ Load Center and Transfer Switch

Page 3: GenReady Load Center and Transfer Switch Load Center.pdfFront Cover & Door. 43.25. Generator Utility. Transfer Operator. Neutral Equipment Ground. Bonding Connection. 14.875 14.38

UNIT DIMENSIONS

14.38

42

Outside Dimensions of Enclosure Shell

15.63

4

Front Cover&

Door

43.25

Generator

Utility

Transfer Operator

Neutral

EquipmentGround

Bonding Connection

14.875

14.38

42

Outside Dimensions of Enclosure Shell

4.5

5

NEMA 1 NEMA 3R

GenReady™ Load Center and Transfer Switch

Page 4: GenReady Load Center and Transfer Switch Load Center.pdfFront Cover & Door. 43.25. Generator Utility. Transfer Operator. Neutral Equipment Ground. Bonding Connection. 14.875 14.38

SPECIFICATIONSEnclosure............................................................................ NEMAType1,orNEMA3R,galvanizedG90steelw/polyesterpowdercoat

MainBreaker.......................................................................................................................................................................... 200Amp

GeneratorSwitch.................................................................................................................................................................... 125Amp

Mainbreakerwiresize........................................................................................................................................#1to300mcmCu-Al

Generatorswitchwiresize..............................................................................................................................#2to1/0Cu,1/0-2/0Al

NeutralLug.................................................................................................................................................................. #6to300mcm

GroundLug.............................................................................................................................................................................#14-2/0

Maximumnumberofcircuits

(standard1"breakers/tandembreakers)

Protectedcircuits...................................................................................................................................................................... 18/30

Non-protectedcircuits...............................................................................................................................................................10/NA

Totalcircuits.............................................................................................................................................................................. 28/40

WithstandratingMainbus(amps)............................................................................................................................................... 10,000

MeetsNECwirebendingspace......................................................................................................................................................... Yes

ETLlisted.......................................................................................................................................................................................... Yes

SeismicallyqualifiedtomeetUBCcode............................................................................................................................................. Yes

Weight–GenReadyBasicw/oEZtransferoperator

(GenReadyAdvancedwithEZtransferoperator)..........................................................................................................45.5lbs.(49lbs.)

Operatingtemperaturerange......................................................................................................................................... -20ºFto140ºF

GeneracPowerSystems,Inc.•S45W29290HWY.59,Waukesha,WI53189•generac.com©2011GeneracPowerSystems,Inc.Allrightsreserved.Allspecificationsaresubjecttochangewithoutnotice.Bulletin0175200SBY-H/PrintedinU.S.A.05/17/11

GenReadyBasic GenReadyAdvanced GenReadyComplete

TheGenReadyloadcenterisinstalledwith-outtheEZTransferOperator™.Itreplacesthehome’smainloadcenter.Thisoptionwillsavethehomeownerthousandsinupgradecostswhenageneratorisinstalled.

TheGenReadyloadcenterisinstalledwiththeEZTransferOperator™.Allfuelandelec-tricallines(contractorsupplied)areinstalledtotheplannedgeneratorsitealongwiththegeneratorpad(ifrequired).Thehomeiscompletelywiredandreadyfortheadditionofageneratorinthefuture.

EverythingincludedintheGenReadyAdvancedlevelisinstalledalongwithanautomaticstandbygenerator.Thehome’sselectedcircuitswillbebackedupbygen-eratorpowerwhenevertheutilityislost.

INSTALLATION OPTIONS

TheNEMA3RGenReadyinstallationissimilarbutissuitableforoutdoorinstallations.

®

GenReady™ Load Center and Transfer Switch