The elegance of a tile easy to lay Large format - Bold-profile tile � 12,7/m2
gallo-romane
44 cm
28 cm
For any projects developed within the context of an HQE®
approach, an Environmental and Health Declaration Sheet for this tile is available on request.
* Usual fitting tolerance stated apply from actual average gauges and widths checked on delivery as per DTU.
3 Neat interlocks3 Recognised levelness3Outstanding finishes
GallO-ROmaNeOverall dimensions in cm
The firing process of the clay may produce slight differences in colour. To obtain a roof with a homogeneous appearance, we recommend mixing tiles from different pallets. The printing processes do not necessarily guarantee a faithful reproduction of colours. Ask to see them in situ.These values are given for information purpose only and are likely to change.
Type Clay roof tile,Double lock and double lapping, interlocking for low pitch roofs
Number of tiles per m2 ≈ 12,7Unit weight ≈ 3,4 kgWeight per m2 ≈ 43,2 kgOverall length ≈ 44 cmOverall width ≈ 28 cmlinear cover ≈ 21,7 cmTheorical gauge ≈ 36,3 cmlongitudinal fitting tolerance ± 0,5 cm*Transversal fitting tolerance ± 0,2 cm*linear meter of battens/m2 2,8 mllaying laid with straight joints right to leftProduct standard NF eN 1304application standard NF P 31-202 [DTU 40.21]
aT n° 5/02 - 1602 dated July 2002 Silicon product an addendum is required for sealsNumber of tioles per pallet 240Weight per pallet 820 kg
prescription recommendation
gUarantee
technical characteristicsThe tile will be in Terracotta, from the large-format bold-profile tile family, double lock and double lapping, more or less 12,7 per square meter, type Gallo-Romane from Monier or similar. Its game of usual assembly shall be 1 cm in longitudinal and 0,4 cm in transversal. It shall be laid straight joints from right to left, on battens according to the standard of NF application NF P 31-202 [DTU 40.21], (Technical Advice n°5/02 - 1602 from July 2002). Its installation shall be carried out using all parts specially designed for dry mortarless laying of ridges and edges as specified in the DTU.
color key
This tile has been developedand tested in the windtunnel at the MonierTechnical Center.
30YEARS
FROSTRESISTANCE
30 YEARS
FROSTRESISTANCE
CLAY TILESClass 1 watertightness
freezing resistance trials carried outaccording to NF EN 539-2
www.marque-nf.com
CONCRETE ROOF TILESwww.marque-nf.com
CONCRETE ROOF TILESwww.marque-nf.com
MCLAY TILES
Class 1 watertightnessfreezing resistance trials carried out
according to NF EN 539-2www.marque-nf.com
CLAY TILESClass 1 watertightness
freezing resistance trials carried outaccording to NF EN 539-2
www.marque-nf.com
MFP
Red (1B) Ochre (1D) Antique Brown(6L) Silvacane Littoral (6A) Silvacane Xahara (6B)
Valmagne Copper (6C) Valmagne Beige (6E) Earth Brown (3F) Atlantic Mixed Shades (3X)
Black (3G)
new
The wide range of Gallo-Romane fittings offers choice of three verge finishes:• round verge,• cloaked verge,• bardelis verge.Verges direction is determined by placing them facing the pitch.a neoprene washer is used for fastening.
monier recommends laying dry with ventilated weather stripping in a roll. This system enables the ridge and hip to adapt to the nature movements of the roof. The ridge courses are made by cutting the tiles closest to the ridge board. all ridges and hips must be fastened with a clip or a screw. The dry ridge/hip is quick to lay, provides good ventilation, and makes future work easier.
the main FeatUres
Interlockingridge/hip tile 33
Interlocking end hip 33
3 way apex
(1) Related to the surface area projected horizontally (2) except for Spirtech® type breathing roof underlays.
Typeof attic
Total ventilationsection (1)
S = 1/5 000
S = 1/3 000
S1 = 1/5 000 S2 = 1/3 000 (2)
S1 = 1/5 000S2 = 1/3 000 (2)
The underside of the tile and their support must be ventilated. This ensures overall correct behaviour of roofing components over time. The use of ventilation tiles is recommended at the upper and lower parts of the roof. The total of ventilation openings must be distributed equally between lower part of the roof slope and near the ridge. Humid or foul air outlets from the ventilation or extraction of living areas by forced mechanical ventilation or other systems, must be routed out of attic spaces. For further information on these two points, please refer to the DTU in force.Preferably, exhaust tiles are to be located at the top of the slope.
Dimensions in cm - lc : linear cover
Note : for better performance, the through tiles must be laid as much as possible near ridges.
These values are given for information purpose only and are likely to change.
VeRGeS
4 ± 0,5
Interlockingridge/hip tile 33
Ridge board
Universal ridgeboard support
Top-course tile
HiP / RiDGe
aeRaTiON, VeNTilaTiON aND illUmiNaTiON
33,728
3/4 gauge tile
36,8
33,7
3/4 gaugedouble tile
34,5
36,8
44
33
Double tile Verge “Saintongeaise” Round verge(right and left)
46 14
11,5Working
width : 9,5
Bardelis verge(right and left)
46
17,5
18 Working height : 15
Cloaked verge(right and left)
18,2
16,2
Screw 70Screw 50
46
Pose à joints droits
Round and proud verges
multipleof lc
multipleof lc
27 27,5
25 25,5
15,5
Cloaked verges
4,59,5
Pose à joints droits
Round and proud verges
multipleof lc
multipleof lc
27 27,5
25 25,5
15,5
Cloaked verges
4,59,5
Top-course tile28
44
Half gauge top-coursetile = 17,5
28
25,5
50
19,2
25
Round ridgeof 50
40,3 22,5
Working width : 14,6Working height : 5
Interlocking ridge/hip tile 33 (3/ml)
33
44
36,8Top-course double tile Half gauge double
top-course tile = 17,5
36,8
25,534,5
Workinglength int : 20,5
54
30
1321
3 way apex(available 4 way apex)
46,5
Interlockinghip tile 40 (2,3/ml)
24,2
Working longth : 16,5Working height : 5,5
Interlocking end hip 40
48,5
24,2 22
Interlocking end hip 33
45
31,5
19,57,5
End ridgefor proud verge
7,5
12
End ridgefor rounded verge
31
29
7,2
31,2
34,2
End ridgefor cloaked verge
WAKAFLEX® (28 or 56 cm)
FIGAROLL® PLUS(28/32 cm)
Hook A for tile and double tile
Clip D pour faîtière de 33
Half-roundridge tile of 50 (2/ml)
Lantern(Ø 120 mm)
44
28Ventilation tile with grid
(opening 21 cm2)
Lantern(Ø 175 mm)
Through tile (Ø 175 mm)
44
49
Through tile (Ø 120 mm)
44
28
Glass tile
28
44
Dimensions in cm
laying straight bond
Valley aND eaVeS
UNDeR-ROOF
layiNG TileS iN a SqUaRe layOUTFor violent winds, mONieR recommends going beyond the DTU recommendation and therefore fastening all tiles.(1) The wind zones considered are those designated by the snow and wind loads code (NV 65) and the sites by the reference building code recommendations. (2) One tile fastened in every five tiles laid. On verges and eaves, all tiles must be fastened.Use of europanneton® FCR inox recommended by monier.
miNimUm SlOPe zONe
miNimUm PiTCH TaBle iN %
France is divided into 3 zones where minimum slope calculations apply (in conjunction with wind-rain)Note : If in doubt regarding which zone applies, please refer to the definition of the zones below.
zONe iThe entire inland territory of the country and the mediterranean coast, at altitudes below 200 m.
zONe ii- The atlantic coast extending 20 km inland, from lorient to the Spanish border. - a strip ranging 20 to 40 km from the coast, from lorient to the Belgian border. - altitudes between 200 m and 500 m
zONe iii- atlantic, english Channel and North Sea coasts extending 20 km inland, from lorient to the Belgian border. - altitudes above 500 m and below 900 m.
Pitches zones 1 and 2(1) zones 1 and 2(1) : exposed site(1)
in % Protected and normal sites(1) zones 3 and 4 : all sites Verges Running Verges Running and eaves portion and eaves portion p ≤ 100 all free all 1/5(2)
100 < p ≤175 all 1/5(2) all 1/5(2)
p > 175 all all all all
all tiles on the eaves must be fastened. Please refer to the DTU in force :• Tranchiclip for cut tiles.• europanneton® FCR inox • CliP e for eaves.monier proposes a range of preformed valleys. laying of an eaves comb prevents rodent and bird intrusion. it is placed at the rake bottom, along the valley. The dimension De mentionned by monier is given as an example. This dimension will vary according to several parameters : cant height, gauge, roof pitch and overhang d, and may be adjusted to achieve the required overlap. The interlocking part (water flow) must to be taken into account when defining dimensions De and d.
These data are applicable to slopes whose horizontal projection does not exceed 12 m. Building code recommendations.
MONIER reserves the right to change the technical characteristics of its range.
ShelteredNormalexposed
zonesSites
zone i192128
zone ii212332
zone iii232634
zone i222430
zone ii242733
zone iii263137
zone i232736
zone ii263039
zone iii303443
up to 6,50 m 6,50 m to 9,50 m 9,50 m to 12 m
Rake length (ground plan)miNimUm aCCePTaBle PiTCHeS aND OVeRlaP iN % (WiTH UNDeRlay)
the main FeatUres the regUlations
This d
ocum
entat
ion, w
hich w
as pu
blishe
d in 0
8/201
6, sup
ersed
es all
previo
us issu
es; it
is a no
n-con
tractu
al do
cumen
t that
may b
e revi
sed at
any t
ime.
Prod
uction
: DTP
: Cen
taure
- Pho
tos: P
. zan
dvliet
- 3D
draw
ings: B
uster
Studio
- X
d
DFDL
DE
LR
Profilo Valley Eave comb(L 1 m - H 75 mm)
Eave tile
44
13
28
lR = Rake length DF = Ridge batten distance = 4 ± 0,5 cmDl = Battening distanceDe = eaves batten distance = 34 cm d = eaves overhang = 8 cm
Tranchiclip
Clip E for eaves
49
Ornementalclay cockerel
24,5Pine-cone finial
(available in 44,5 cm)
37
18
ORNameNTS57,5
Fleur de Lysfinial
18
miNimUm aCCePTaBle PiTCHeS aND OVeRlaP iN % (NO UNDeRlay)
ShelteredNormalexposed
zonesSites
zone i222533
zone ii242737
zone iii273040
zone i262835
zone ii283239
zone iii303643
zone i273242
zone ii303545
zone iii354050
up to 6,50 m 6,50 m to 9,50 m 9,50 m to 12 mRake length (ground plan)
To prevent ingress of powder snow, the DTU recommends the use of an underlay. This use is also advocated by SNEST in order to catch and lead down to the gutter any small amounts of water as well as to protect against the ingress of dust or soot.
DeFiNiTiON OF SiTeS aCCORDiNG TO THe DTUSiTeS
Scheltered
Normal
exposed
DeFiNiTiON Low ground, entirely surrounded by hills which protect it against all wind directions. Site partially bounded by hills in the direction of the most violent winds that provide protection against winds in this direction only.
Plain or plateau with slight vertical intervals, whether extensive or not (valleys, undulations).
Near the sea: inland to a distance of 5 km; the tops of cliffs, islands or narrow peninsulas, estuaries or sheltered bays and ria. Inland: narrow valleys into which the wind is channelled, isolated and high mountains (for example: Mont-Aigoual and Mont-Ventoux) and certain mountain passes.
This breakdown into three zones should not be confused with the breakdown into Snow and Wind regions given in the NV (Snow and Wind) rules.
SPAN-FLEX® 200
SPAN-FLEX®
300SPAN-ALU
300VAPOTECH BBC
300CLIMA COMFORT
RENOCLIMA COMFORT
SUN
ECOTECH®
200SPIRTECH®
110SPIRTECH®
200SPIRTECH®
300SPIRTECH®
200 BBCSPIRTECH® 300 BBC
SPIRTECH SUN200 BBC
head office: 23-25, avenue du docteur lannelongue - 75014 parist : 01 40 84 67 00 - F : 01 40 84 67 01 www.monier.fr
Fabienne alexandre - export manager - 23-25, avenue du Docteur lannelongue - 75014 Parist : 00 33 1 40 84 66 98 - e : [email protected] perrot - Trade export assistant - B.P. 4 - 16270 Roumazières - France t : 00 33 5 45 71 88 92 - F : 00 33 5 45 71 88 93 - e : [email protected]
Top Related