MSUM Institution Profile
• 140 acres• 39 buildings,
1.8 million sq. ft.• 7,500 students• 790 employees• Operating budget:
$80 million
Campus Systems
Variable Air Volume
Constant Volume
Multi-zone Dual Duct Residential Furnace
22 60 19 2 43
Campus AHUs
Honeywell Security Johnson Controls Security
113 card readers 135 card readers
Campus Security (door locks)
Campus VAVsHoneywell VAVs Johnson Controls VAVs
CB 53 vav, 21ftr HAG 77 vav
CMU 72 vav Wellness 28 vav
FF 42 vav
Kise 12 vav
Lom 16 uh, 37 ftr, 77 vav
MAC ftr, 66 vav
MUR 17 vav
Campus Systems
The Problem• Poor energy efficiency across campus– Most systems operated 14-18 hours per day– Energy consumption (2008): 163 kBTU/sq. ft.
• Restricted budget• Redundant, time consuming data entry
The Opportunity
• Event Management System– Dean Evans EMS®
• Low classroom use– Average of 17% campus-wide
• Opportunity to link to HVAC
The Solution
1• Update systems to direct digital control
2• Integrate Systems with Honeywell EBI®
3• Implement demand-limiting load shedding
4• Implement Events2HVAC™
1. Direct Digital Control
• Pneumatic Control– Assumes AHU Control on/off– No remote control of Zone– Some “night setback” control air pressure
• Early DDC (30-40 years old)– Major systems only Chillers, AHUs, Pumps, Boilers– No communication between different manufacturers
• Modern DDC supports open protocol• Zone Control for individual rooms
2. Honeywell EBI®
• Integrate various legacy and vendor systems to open protocols and data formats
• 3rd Parties can consume data for enterprise reporting
• 3rd parties can integrate systems for energy efficiency– Events2HVAC– Demand Limiting – Load Shedding
3. Demand-Limiting Load Shedding
• Predicts demand peaks• Sheds loads to control demand peaks• Lowers energy usage on high demand days• Lowers energy rates
4. Events2HVAC™
• Links event schedules to HVAC• Saves energy in unoccupied rooms• Eliminates redundant data entry• Adjusts dynamically to changing schedules
Events2HVAC™ How to Set it Up
• Know what / how your current HVAC system is set up
• Know what you want to control• Determine Building Hours & Building
Occupancy Hours• Add “HVAC” as a Building• Start Adding “Rooms” to drive operations
How Does it Change Scheduling?
• HVAC only runs on “Booked” status• Ballroom “event preset”• Creating “building occupancy” in addition to
setting building hours• Added reservations to maintain
Negative Side Effects
• Extra Reservations & Bookings to make• Scheduling of Rooms for deep cleaning • Load shedding is not always pleasant• 2 hour sync time frame• Hard to control humidity / heat in side rooms• Intricacies of certain buildings / spaces
Positive Side Effects
• Reduced GMW labor on campus for cleaning• Increase in room requests, decrease in “room
crashing”• Doors can be tied into the system• Easy to extend the HVAC run time
• $$$ SAVINGS!