DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING
LABORATORY MANUAL
Subject Name: ELECTRICAL ENGINEERING LABSubject Code : 131354Semester : III
7/31/2019 Electrical Engg CSE
3/112
Chennai Institute of Technology
3 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
ELECTRICAL ENGINEERING
LIST OF EXPERIMENTS:
1. Load test on DC Shunt & DC Series motor
2. O.C.C & Load characteristics of DC Shunt and DC Series generator3. Speed control of DC shunt motor (Armature, Field control)4. Load test on single phase transformer5. O.C & S.C Test on a single phase transformer6. Regulation of an alternator by EMF & MMF methods.7. V curves and inverted V curves of synchronous Motor8. Load test on three phase squirrel cage Induction motor9. Speed control of three phase slip ring Induction Motor10. Load test on single phase Induction Motor.11. Study of DC & AC Starters
7/31/2019 Electrical Engg CSE
4/112
Chennai Institute of Technology
4 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
7/31/2019 Electrical Engg CSE
5/112
Chennai Institute of Technology
5 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
Ex.No:DATE:
LOAD TEST ON DC SHUNT MOTOR
AIM:
To conduct a load test on DC shunt motor and to find its efficiency
APPARATUS REQUIRED:
S.No. Apparatus Range Type Quantity
1 Ammeter (0-20)A MC 1
2 Voltmeter (0-300)V MC 1
3 Rheostat 1250, 0.8A Wire Wound 1
4 Tachometer (0-1500) rpm Digital 1
5 Connecting Wires 2.5sq.mm. Copper Few
PRECAUTIONS:
1. DC shunt motor should be started and stopped under no load condition.
2. Field rheostat should be kept in the minimum position.3. Brake drum should be cooled with water when it is under load.
PROCEDURE:
1. Connections are made as per the circuit diagram.
7/31/2019 Electrical Engg CSE
6/112
Chennai Institute of Technology
6 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
TABULAR COLUMN:
S.No.
Voltage
V
(Volts)
Current
I
(Amps)
Spring Balance
Readings(S1 S2)Kg
Speed
N
(rpm)
Torque
T
(Nm)
Output
Power
Pm
(Watts)
Input
Power
Pi
(Watts)
Efficiency
%S1(Kg) S2(Kg)
7/31/2019 Electrical Engg CSE
7/112
Chennai Institute of Technology
7 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
Circumference of the Brake drum = cm.
2. After checking the no load condition, and minimum field rheostat position, DPST switch is closed and starter resistance is gradually
removed.
3. The motor is brought to its rated speed by adjusting the field rheostat.
4. Ammeter, Voltmeter readings, speed and spring balance readings are noted under no load condition.
5. The load is then added to the motor gradually and for each load, voltmeter, ammeter, spring balance readings and speed of the motor arenoted.
The motor is then brought to no load condition and field rheostat to minimum position, then DPST switch is opened
FORMULAE:
CircumferenceR = ------------------- m Torque T = (S1 S2) x R x 9.81 Nm
100 x2 Input Power Pi = VI Watts2NT
Output Power Pm = ------------ Watts60
Output Power
Efficiency % = -------------------- x 100%Input Power
7/31/2019 Electrical Engg CSE
8/112
Chennai Institute of Technology
8 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
MODEL GRAPHS:
MODEL CALCULATION:
SpeedN(rpm)
y
x
Torque T (Nm)
Speed
N(rpm)
TorqueT(Nm)
Efficie
ncy%
N
T
y3 y2 y1
Out ut Power Watts
7/31/2019 Electrical Engg CSE
9/112
Chennai Institute of Technology
9 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
RESULT: Thus the load test on DC shunt motor is conducted and its efficiency is determined.
7/31/2019 Electrical Engg CSE
10/112
Chennai Institute of Technology
10 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
7/31/2019 Electrical Engg CSE
11/112
Chennai Institute of Technology
11 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
7/31/2019 Electrical Engg CSE
12/112
Chennai Institute of Technology
12 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
Ex.No:
DATE: LOAD TEST ON DC SERIES MOTOR
AIM:
To conduct a load test on DC Series Motor and to find its efficiency
APPARATUS REQUIRED:
S.No. Apparatus Range Type Quantity
1 Ammeter (0-20)A MC 1
2 Voltmeter (0-300)V MC 1
3 Tachometer(0-3000)
rpmDigital 1
4 Connecting Wires 2.5sq.mm. Copper Few
PRECAUTIONS:
1. The motor should be started and stopped with load
2. Brake drum should be cooled with water when it is under load.
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. After checking the load condition, DPST switch is closed and starter resistance is gradually removed.
3. For various loads, Voltmeter, Ammeter readings, speed and spring balance readings are noted.
4. After bringing the load to initial position, DPST switch is opened.
TABULAR COLUMN:
7/31/2019 Electrical Engg CSE
13/112
Chennai Institute of Technology
13 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
S.No.
Voltage
V
(Volts)
Current
I
(Amps)
Spring BalanceReadings
(S1 S2)KgSpeed
N
(rpm)
Torque
T
(Nm)
OutputPower
Pm
(Watts)
InputPower
Pi
(Watts)
Efficiency
%S1(Kg) S2(Kg)
Circumference of the Brake drum = cm.
FORMULAE:
7/31/2019 Electrical Engg CSE
14/112
Chennai Institute of Technology
14 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
Circumference
R = ------------------- m100 x2
Torque T = (S1 S2) x R x 9.81 Nm
Input Power Pi = VI Watts
2NTOutput Power Pm = ------------ Watts
60
Output Power
Efficiency % = -------------------- x 100%
Input Power
MODEL GRAPH:
eT
Nm
N
rm
nc%
y3 y2 y1
T
7/31/2019 Electrical Engg CSE
15/112
Chennai Institute of Technology
15 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
MODEL CALCULATION:
7/31/2019 Electrical Engg CSE
16/112
Chennai Institute of Technology
16 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
RESULT: Thus the load test on DC series motor is conducted and its efficiency is determined.
7/31/2019 Electrical Engg CSE
17/112
Chennai Institute of Technology
17 Faculty name: G.Keerthi Vijayadhasan Dept:EEE
7/31/2019 Electrical Engg CSE
18/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
19/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
Ex.No:
DATE:OPEN CIRCUIT AND LOAD CHARACTERISTICS OF SELF EXCITED
DC SHUNT GENERATOR
AIM:
To obtain open circuit characteristics of self excited DC shunt generator and to find its critical resistance
APPARATUS REQUIRED:
S.No. Apparatus Range Type Quantity
1 Ammeter (0-1)A MC 1
2 Voltmeter (0-300)V MC 1
3 Rheostats 1250, 0.8A Wire Wound 2
4 SPST Switch - - 1
5 Tachometer (0-1500)rpm Digital 1
6 Connecting Wires 2.5sq.mm. Copper Few
PRECAUTIONS:
1. The field rheostat of motor should be in minimum resistance position at the time of starting and stopping the machine.
2. The field rheostat of generator should be in maximum resistance position at the time of starting and stopping the machine.
3. SPST switch is kept open during starting and stopping.
7/31/2019 Electrical Engg CSE
20/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
TABULAR COLUMN:
S.N
o.
Field
Current
If (Amps)
Armature
Voltage
Eo (Volts)
MODEL GRAPH:
Eo
If
Critical Resistance = Eo / IfOhmsEo(Volts)
If(Amps)
7/31/2019 Electrical Engg CSE
21/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
For open circuit:
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. After checking minimum position of motor field rheostat, maximum position of generator field rheostat, DPST switch is closed and
starting resistance is gradually removed.
3. By adjusting the field rheostat, the motor is brought to rated speed.
4. Voltmeter and ammeter readings are taken when the SPST switch is kept open.
5. After closing the SPST switch, by varying the generator field rheostat, voltmeter and ammeter readings are taken.
6. After bringing the generator rheostat to maximum position, field rheostat of motor to minimum position, SPST switch is opened and
DPST switch is opened.
For load test:
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. After checking minimum position of DC shunt motor field rheostat and maximum position of DC shunt generator field rheostat, DPST
switch is closed and starting resistance is gradually removed.
3. Under no load condition, Ammeter and Voltmeter readings are noted, after bringing the voltage to rated voltage by adjusting the field
rheostat of generator.
4. Load is varied gradually and for each load, voltmeter and ammeter readings are noted.5. Then the generator is unloaded and the field rheostat of DC shunt generator is brought to maximum position and the field rheostat of
DC shunt motor to minimum position, DPST switch is opened.
7/31/2019 Electrical Engg CSE
22/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
DETERMINATION OF ARMATURE RESISTANCE:
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. Supply is given by closing the DPST switch.
3. Readings of Ammeter and Voltmeter are noted.
4. Armature resistance in Ohms is calculated as Ra = (Vx1.5) /I
D
P
S
T
S
W
I
T
C
H
+
-
-+
(0-300)VMC
(0-20)A
MC
Fuse
Fuse
A1
A2
27A
27A
LOAD
5 KW, 230V
G
A
V220V
DC
Supply
+
-
7/31/2019 Electrical Engg CSE
23/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
TABULAR COLUMN:
S.No. Voltage
V (Volts)
Current
I (Amps)
Armature Resistance
Ra (Ohms)
TABULAR COLUMN:
S.No.
Field
CurrentIf (Amps)
Load
CurrentIL (Amps)
Terminal
Voltage(V) Volts
Ia = IL + If
(Amps) Eg =V + Ia Ra
(Volts)
7/31/2019 Electrical Engg CSE
24/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
FORMULAE:
Eg = V + Ia Ra (Volts)
Ia = IL + If (Amps)
Eg : Generated emf in Volts
V : Terminal Voltage in Volts
Ia : Armature Current in Amps
IL : Line Current in Amps
If : Field Current in Amps
Ra : Armature Resistance in Ohms
7/31/2019 Electrical Engg CSE
25/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
MODEL GRAPH:
MODEL CALCULATION:
VL,E
Volts
If, IL (Amps)
V Vs IL
(Ext Char)
E Vs IL
(Int Char)
7/31/2019 Electrical Engg CSE
26/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
RESULT:
Thus the open circuit and load characteristic of self excited DC shunt generator is obtained.
7/31/2019 Electrical Engg CSE
27/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
28/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
Ex.No:
DATE:
OPEN CIRCUIT CHARACTERISTICS OF SEPARATELY EXCITED DC SHUNT GENERATOR
AIM:
To obtain open circuit characteristics of separately excited DC shunt generator.
APPARATUS REQUIRED:
S.No. Apparatus Range Type Quantity
1 Ammeter (0-1)A MC 1
2 Voltmeter (0-300)V MC 1
3 Rheostats 1250, 0.8A Wire Wound 2
4 Tachometer (0-1500)rpm Digital 1
5 Connecting Wires 2.5sq.mm. Copper Few
PRECAUTIONS:
1. The field rheostat of motor should be in minimum resistance position at the time of starting and stopping the machine.
2. The field rheostat of generator should be in maximum resistance position at the time of starting and stopping the machine.
7/31/2019 Electrical Engg CSE
29/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
Eo(Volts)
If(Amps)
TABULAR COLUMN:
MODEL GRAPH:
S.No.Field Current
If (Amps)
Armature Voltage
Eo (Volts)
7/31/2019 Electrical Engg CSE
30/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
For open circuit:
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. After checking minimum position of motor field rheostat, maximum position of generator field rheostat,
DPST switch is closed and starting resistance is gradually removed.
3. By adjusting the field rheostat, the motor is brought to rated speed.
4. By varying the generator field rheostat, voltmeter and ammeter readings are taken.
5. After bringing the generator rheostat to maximum position, field rheostat of motor to minimum position, DPST switch is opened.
For load test:
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. After checking minimum position of DC shunt motor field rheostat and maximum position of DC shunt generator field rheostat, DPST
switch is closed and starting resistance is gradually removed.
3. Under no load condition, Ammeter and Voltmeter readings are noted, after bringing the voltage to rated voltage by adjusting the field
rheostat of generator.
4. Load is varied gradually and for each load, voltmeter and ammeter readings are noted.
5. Then the generator is unloaded and the field rheostat of DC shunt generator is brought to maximum position and the field rheostat of
DC shunt motor to minimum position, DPST switch is opened.
7/31/2019 Electrical Engg CSE
31/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
DETERMINATION OF ARMATURE RESISTANCE:
MODEL GRAPH:
D
P
S
T
S
WI
TC
H
+
-
-+
(0-300)V
MC
(0-20)A
MC
Fuse
Fuse
A1
A2
27A
27A
LOAD
5 KW, 230V
G
A
V220V
DC
Supply
+
-
V
L,E
Volts
If, IL (Amps)
V Vs IL
(Ext Char)
E Vs IL
(Int Char)
7/31/2019 Electrical Engg CSE
32/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. Supply is given by closing the DPST switch.
3. Readings of Ammeter and Voltmeter are noted.
4. Armature resistance in Ohms is calculated as Ra = (Vx1.5) /I
FORMULAE:
Eg = V + Ia Ra (Volts)Ia = IL + If (Amps)
Eg : Generated emf in Volts
V : Terminal Voltage in Volts
Ia : Armature Current in Amps
IL : Line Current in Amps
If : Field Current in Amps
Ra
: Armature Resistance in Ohms
7/31/2019 Electrical Engg CSE
33/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
TABULAR COLUMN:
S.No. Voltage
V (Volts)
Current
I (Amps)
Armature Resistance
Ra (Ohms)
TABULAR COLUMN:
S.No.
Field
CurrentIf (Amps)
Load
CurrentIL (Amps)
Terminal
Voltage(V) Volts
Ia = IL + If
(Amps) Eg =V + Ia Ra(Volts)
7/31/2019 Electrical Engg CSE
34/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
RESULT:
Thus the open circuit and load characteristics of separately excited DC shunt generator are obtained.
7/31/2019 Electrical Engg CSE
35/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
36/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
Ex.No: SPEED CONTROL OF DC SHUNT MOTOR
DATE:
AIM:
To obtain speed control of DC shunt motor by
a. Varying armature voltage with field current constant.
b. Varying field current with armature voltage constant
APPARATUS REQUIRED:
S.No. Apparatus Range Type Quantity
1 Ammeter (0-20) A MC 1
2 Voltmeter (0-300) V MC 1
3 Rheostats 1250, 0.8A50, 3.5A
WireWound
Each 1
4 Tachometer (0-3000) rpm Digital 1
5 Connecting Wires 2.5sq.mm. Copper Few
PRECAUTIONS:
1. Field Rheostat should be kept in the minimum resistance position at the time of starting and stopping the motor.
2. Armature Rheostat should be kept in the maximum resistance position at the time of starting and stopping the motor.
7/31/2019 Electrical Engg CSE
37/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
TABULAR COLUMN:
(i) Armature Voltage Control:
S.No.
If1 = If2 = If3 =
Armature
Voltage
Va ( Volts)
Speed
N (rpm)
Armature
Voltage
Va ( Volts)
Speed
N (rpm)
Armature
Voltage
Va ( Volts)
Speed
N (rpm)
(ii) Field Control:
S.No.
Va1 = Va2 = Va3 =
Field
Current
If (A)
Speed
N (rpm)
Field
Current
If (A)
Speed
N (rpm)
Field
Current
If (A)
Speed
N (rpm)
7/31/2019 Electrical Engg CSE
38/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. After checking the maximum position of armature rheostat and minimum position of field rheostat, DPST switch is closed
(i) Armature Control:
1. Field current is fixed to various values and for each fixed value, by varying the armature rheostat, speed is noted for various voltages
across the armature.(ii)Field Control:
1. Armature voltage is fixed to various values and for each fixed value, by adjusting the field rheostat, speed is noted for various field
currents.
2. Bringing field rheostat to minimum position and armature rheostat to maximum position DPST switch is opened.
7/31/2019 Electrical Engg CSE
39/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
MODEL GRAPHS:
SpeedN(rpm)
SpeedN(rpm)
If(Amps)Va (Volts)
If1
If3
If2
Va3
Va1
Va2
7/31/2019 Electrical Engg CSE
40/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
RESULT:
Thus the speed control of DC Shunt Motor is obtained using Armature and Field control methods.
7/31/2019 Electrical Engg CSE
41/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
42/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
Ex.No:
DATE: LOAD TEST ON A SINGLE PHASE TRANSFORMER
AIM:
To conduct a load test on single phase transformer to find its efficiency and percentage regulation
APPARATUS REQUIRED:
S.No. Apparatus Range Type Quantity
1 Ammeter(0-10)A
(0-5) A
MI
MI
1
1
2 Voltmeter(0-150)V
(0-300) V
MI
MI
1
1
3 Wattmeter(300V, 5A)
(150V, 5A)
Upf
Upf
1
1
4 Auto Transformer 1, (0-260)V - 1
5 Resistive Load 5KW, 230V - 1
6 Connecting Wires 2.5sq.mm Copper Few
7/31/2019 Electrical Engg CSE
43/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
TABULAR COLUMN:
Load
Primary Secondary Input
Power
W1 x
MF
Output
Power
W2 x
MF
Efficiency
%
%
RegulationV1(V)
I1
(A)
W1
(W)
V2(V)
I2
(A)
W2
(W)
7/31/2019 Electrical Engg CSE
44/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
PRECAUTIONS:
1. Auto Transformer should be in minimum position.
2. The AC supply is given and removed from the transformer under no load condition.
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. After checking the no load condition, minimum position of auto transformer and DPST switch is closed.
3. Ammeter, Voltmeter and Wattmeter readings on both primary side and secondary side are noted.
4. The load is increased and for each load, Voltmeter, Ammeter and Wattmeter readings on both primary and secondary sides are
noted.
5. Again no load condition is obtained and DPST switch is opened.
FORMULAE:
Output Power = W2 x Multiplication factor
Input Power = W1 x Multiplication factor
Output PowerEfficiency % = -------------------- x 100%
Input PowerVNL - VFL (Secondary)
Regulation R % = ------------------------------ x 100%VNL
7/31/2019 Electrical Engg CSE
45/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
MODEL GRAPHS:
MODEL CALCULATION:
Efficienc
%
RegulationR%
R
Output Power (Watts)
7/31/2019 Electrical Engg CSE
46/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
RESULT:
Thus the load test on single phase transformer is conducted to determine its efficiency.
7/31/2019 Electrical Engg CSE
47/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
48/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
Ex.No:
DATE:
OPEN CIRCUIT & SHORT CIRCUIT TEST ON A SINGLE PHASE TRANSFORMER
AIM:
To predetermine the efficiency and regulation of a transformer by conducting open circuit test and short circuit test and to draw
equivalent circuit
APPARATUS REQUIRED:
S.No. Apparatus Range Type Quantity
1 Ammeter(0-2)A
(0-5) A
MI
MI
1
1
2 Voltmeter (0-150)V MI 2
3 Wattmeter(150V, 5A)
(150V, 5A)
LPF
UPF
1
1
4 Connecting Wires 2.5sq.mm Copper Few
PRECAUTIONS:
1. Auto Transformer should be in minimum voltage position at the time of closing & opening DPST Switch.
7/31/2019 Electrical Engg CSE
49/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
50/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
PROCEDURE:
OPEN CIRCUIT TEST:
1. Connections are made as per the circuit diagram.
2. After checking the minimum position of Autotransformer, DPST switch is closed.
3. Auto transformer variac is adjusted get the rated primary voltage.
4. Voltmeter, Ammeter and Wattmeter readings on primary side are noted.
5. Auto transformer is again brought to minimum position and DPST switch is opened.
SHORT CIRCUIT TEST:
1. Connections are made as per the circuit diagram.
2. After checking the minimum position of Autotransformer, DPST switch is closed.
3. Auto transformer variac is adjusted get the rated primary current.
4. Voltmeter, Ammeter and Wattmeter readings on primary side are noted.
5. Auto transformer is again brought to minimum position and DPST switch is opened.
7/31/2019 Electrical Engg CSE
51/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
TABULAR COLUMN:
SHORT CIRCUIT TEST:
Vs/c
(Volts)
Is/c
(Amps)
Ws/c
(Watts)
TABULAR COLUMN:
OPEN CIRCUIT TEST:
Vo/c
(Volts)
Io/c
(Amps)
Wo/c
(Watts)
7/31/2019 Electrical Engg CSE
52/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
FORMULAE:
Core loss: Wo = VoIo cos o
Wo Wo
cos o = ------- o = cos-1 -------
Vo Io Vo Io
I = Io cos o (Amps) I = Io sin o (Amps)
Percentage Efficiency: for all loads and p.f.Output Power (X) x KVA rating x 1000 x cos
Efficiency % = -------------------- = ------------------------------------------------Input Power Output power + losses
V0
Ro = ------- I
V0
Xo = ------- I
Wsc
Ro2 = ------- Isc
2
Vsc
Zo2 = ------- Isc
Xo2 = (Zo2 - Ro22)1/2
R02
Ro1 = ------- K
2
X02
Xo1 = ------- K
2
V2
K= ------- = 2
V1
7/31/2019 Electrical Engg CSE
53/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
EQUIVALENT CIRCUIT:
MODEL GRAPHS:
ZL = ZL/K2
Efficienc
%
Output power (Watts)
Xo1Ro1
Ro Xo
Vo
Io
ISCo
R
N
L
O
A
D
w
%
%
Percentage Regulation:
7/31/2019 Electrical Engg CSE
54/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
Percentage Regulation:
(X) x Isc (Ro2 cos Xo2sin ) x 100
R% = --------------------------------------
V2
(X) x KVA rating x 1000 x cos
Where X is the load and it is 1 for full load, for half load, load, load etc.. and the power factor is, upf, o.8 p.f lag and 0.8 p.f lead
RESULT:
Thus the efficiency and regulation of a transformer is predetermined by conducting open circuit test and short circuit test and the
equivalent circuit is drawn.
.
+ = lagging
- = leading
7/31/2019 Electrical Engg CSE
55/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
56/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
EX.NO:
DATE: REGULATION OF 3PHASE ALTERNATOR BY EMF AND MMF METHODS
AIM:
To predetermine the regulation of 3-phase alternator by EMF and MMF methods and also draw the vector diagrams.
APPARATURS REQUIRED:
SL.NO Name of the Apparatus Type Range Quantity
1 Ammeter MC 0 1/2 A 1
2 Ammeter MI 0 5/10 A 1
3 Voltmeter MC 0 10 V 1
4 Voltmeter MI 0 600 V 1
5 Rheostat Wire
wound
250 , 1.5 A 1
6 Rheostat Wire
wound
1200, 0.8 A 1
7 Tachometer Digital --- 1
8 TPST knife switch -- -- 1
REGULATION OF 3-PHASE ALTERNATOR BY EMF AND MMF METHODS
7/31/2019 Electrical Engg CSE
57/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
REGULATION OF 3 PHASE ALTERNATOR BY EMF AND MMF METHODS
TABULAR COLUMNS: OPEN CIRCUIT TEST:
S.No.
Field Current (If) Open Circuit Line
Voltage (VoL)
Open circuit Phase
Voltage (Voph)
Amps Volts Volts
THEORY:
7/31/2019 Electrical Engg CSE
58/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
The regulation of a 3-phase alternator may be predetermined by conducting the Open Circuit (OC) and the Sort Circuit (SC) tests.
The methods employed for determination of regulation are EMF or synchronous impedance method, MMF or Ampere Turns method and
the ZPF or Potier triangle method. In this experiment, the EMF and MMF methods are used. The OC and SC graphs are plotted from the
two tests. The synchronous impedance is found from the OC test. The regulation is then determined at different power factors by
calculations using vector diagrams. The EMF method is also called pessimistic method as the value of regulation obtained is much more
than the actual value. The MMF method is also called optimistic method as the value of regulation obtained is much less than the actual
value. In the MMF method the armature leakage reactance is treated as an additional armature reaction. In both methods the OC and SC
test data are utilized.
PRECAUTIONS:
(i) The motor field rheostat should be kept in the minimum resistance position.
(ii) The alternator field potential divider should be kept in the minimum voltage position.
(iii) Initially all switches are in open position.FORMULAE:
1. Armature Resistance Ra =
2. Synchronous Impedance Zs = O.C. voltage
S.C. current
3. Synchronous Reactance Xs = Zs2 Ra2
4. Open circuit voltage for lagging p.f = (Vcos + IaRa)2 + (Vsin + IaXs)2
5. Open circuit voltage for leading p.f. = (Vcos + IaRa)2 + (Vsin IaXs)2
6. SHORT CIRCUIT TEST:
7/31/2019 Electrical Engg CSE
59/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
S.No. Field Current (If)
Short Circuit Current
(120% to 150% of rated
current) (ISC)
Amps Amps
7/31/2019 Electrical Engg CSE
60/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7. Open circuit voltage for unity p.f = (V + IaRa)2 + ( IaXs)2
8. Percentage regulation = Eo V x 100
V
EXP.NO: REGULATION OF 3-PHASE ALTERNATOR BY EMF AND MMF METHODS
7/31/2019 Electrical Engg CSE
61/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
TABULAR COLUMNS
EMF METHOD:
SL.NO. Power
factor
Eph (V) % Regulation
Lag Lead Lag Lead
MODEL CALCULATION:
7/31/2019 Electrical Engg CSE
62/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
MMF METHOD:
7/31/2019 Electrical Engg CSE
63/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
MODEL CALCULATION:
SL.NO
.
P.F Vph
(V)
If1
(A)
If2
(A)
Ifr
(A)
Eph (V) % Regulation
Lag Lead Lag Lead Lag Lead
7/31/2019 Electrical Engg CSE
64/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
RESULT:
Thus the regulation of 3-phase alternator has been predetermined by the EMF and MMF methods.
Ci i Di
7/31/2019 Electrical Engg CSE
65/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
Circuit Diagram
7/31/2019 Electrical Engg CSE
66/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
EXP.NO: V AND INVERTED V CURVES OF THREE PHASE SYNCHRONOUS MOTOR
AIM:
To draw the V-Curves and inverted v-curves of the given three phase synchronous motor by constant output.
APPARATUS REQUIRED:
S. No. Name of the Equipment Range Type Qty
THEORY:Refer book and write
PRECAUTIONS:
1. The field rheostat of motor should be in minimum resistance position initially.
2. The field rheostat of alternator should be in maximum resistance position while starting.
7/31/2019 Electrical Engg CSE
67/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
NAME PLATE DETAILS:
PROCEDURE:
7/31/2019 Electrical Engg CSE
68/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
OC Test:
1. Connections are made as per the circuit diagram2. DPST I is closed and the motor is started using a 3 point starter3. The field rheostat of motor is adjusted to give rated speed of alternator.4. DPST 2 is closed and the field rheostat of alternator is adjusted to get
various voltages and corresponding field currents are noted. This procedure isrepeated up to rated field current.
SC Test:1. Connections are made as per the circuit diagram.2. DPST I is closed and the motor is started using a 3 point starter.3. The field rheostat of motor is adjusted to get rated speed of the alternator.4. The field rheostat of alternator is adjusted to get rated current in the armature
of alternator.5. This value of Isc and the corresponding If are noted.6. The field rheostat of alternator is brought back to maximum resistance
Position and the field rheostat of the motor is brought back to minimum
Resistance position.7. Open the DPSTS.
Determination of Ra:1. Connections are made as per the circuit diagram2. DPSTS is closed and the rheostat is adjusted3. For various values of voltages the value of current is noted4. The rheostat is brought back to maximum position
5. DPSTS is opened.
TABULATION:Open Circuit Test
7/31/2019 Electrical Engg CSE
69/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
S.No. No load voltageV0No Load Field CurrentIf
Short Circuit Test:
S.No. Rated I(A) If (A)
SDetermination of Ra:
S.No.Armature Voltage Va Armature Current Ia
Armature ResistanceRa
V A
MODEL CALCULATION:
FORMULAE USED
7/31/2019 Electrical Engg CSE
70/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
FORMULAE USED:
Ra= Rdc* 1.3
Zs= Vph/Isc
Xs= ((Zs2-Ra
2)
=tan-1(Xs/Ra)
Iphcos= P/3VL
SYNCHRONOUS REACTANCE:
OCC and SC characteristic are drawn as shown. The field current OA gives the rated voltage per phase RV. The same field current RAgiven as armature current OB on short circuit.
Therefore Synchronous Impedance, ZS=OV/OBTherefore Synchronous Reactance, XS=ZS2 RS2
CONSTANT INPUT POWER LINE:
Let P be the constant total input to the synchronous motor. Therefore constant input power per phase equals P/3.
Therefore Vph*Iph*cos=P/3Iph* cos=P/3Vph
Since P & V are constant Iph*cos is also a constant.The reference OV1 is drawn to represent V as shown in the figure.The vector OR is equal to Vph/ZS is drawn lagging OV1 by an angle
S N % E it tiE0
(RQ)If
(RG)Ia
(OT)cos
7/31/2019 Electrical Engg CSE
71/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
S.No. % Excitation (RQ) (RG) (OT)=SOT
V A A
MODEL GRAPH:
V Curves.
Where = tan-1(XS/Rac) OS is made equal to Iphcos. At a line STU is drawn perpendicular to the reference vector OV1. This linerepresents the constant input power line.
7/31/2019 Electrical Engg CSE
72/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
CONSTANT EXCITATION CIRCLES:
OR=Vph/Zph represents 100% excitation with R as centre and OR as radius a circle is drawn. This circle is known as 100% excitationcircle. Similarly constant excitation circle cuts the constant input power line at T.
Now OT=Armature Current per phase Ia
Angle SOT = Power factor angle
Similarly other excitation circles determine the armature current and the PF angle at different excitation. The results are tabulated asshown.
Inverted V Curves
7/31/2019 Electrical Engg CSE
73/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
74/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
RESULT:
Thus V-curves and inverted V curves of synchronous motor were drawn.
7/31/2019 Electrical Engg CSE
75/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
76/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
EX.NO:
7/31/2019 Electrical Engg CSE
77/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
DATE: LOAD TEST ON 3-PHASE SQUIRREL CAGE INDUCTION MOTOR
AIM:
To draw the performance characteristics of 3-phase squirrel cage induction motor by conducting load test.
APPARATUS REQUIRED:
FUSE RATING;
125% of rated current______A = ____A
THEORY:
A 3-phase induction motor consists of stator and rotor with the other associated parts. In the stator, a 3-phase winding is provided.
The windings of the three phase are displaced in space by 120.A 3-phase current is fed to the 3-phase winding. These windings produce a
resultant magnetic flux and it rotates in space like a solid magnetic poles being rotated magnetically.
S.No Name of apparatus Range Type Qty.
1. Ammeter (0-5)A MI 1
2. Voltmeter (0-600)V MI 1
3. Wattmeter (600V,5A) UPF 2
4. Tachometer Digital 1
5. 3- autotransformer 1
7/31/2019 Electrical Engg CSE
78/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
PRECAUTIONS:
1. TPST switch is kept open initially.
2 A t t f i k t t i lt iti
7/31/2019 Electrical Engg CSE
79/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
2. Autotransformer is kept at min. voltage position.
3. There must be no load when starting the load.
PROCEDURE:
1. Connections are given as per circuit diagram.
2. 3- induction motor is started with DOL starter.
3. If the pointer of one of the wattmeter readings reverses, interchange the current coil terminals and take the reading as negative.
3. The no load readings are taken.
4. The motor is loaded step by step till we get the rated current and the readings of the voltmeter, ammeter, wattmeter, spring balance are
noted.
FORMULAE USED:
1) % slip= (Ns-N/Ns)*100
2) Input Power = (W1+W2)watts
3) Output Power = 2NT/60 watts
4) Torque = 9.81*(S1-S2)*R N-m
5) % efficiency = (o/p power/i/p power)* 100
GRAPHS:
7/31/2019 Electrical Engg CSE
80/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
1) Output Power vs. Efficiency
2) Output Power vs. Torque
3) Output Power vs. Speed
4) Output Power vs. %s
MODEL CALCULATION:
7/31/2019 Electrical Engg CSE
81/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
RESULT:
Thus the performance characteristic of a 3- squirrel cage induction motor by conducting load test has been drawn.
7/31/2019 Electrical Engg CSE
82/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
EX.NO:
DATE: LOAD TEST ON 3-PHASE SLIP RING INDUCTION MOTOR
7/31/2019 Electrical Engg CSE
83/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
O S O 3 S S G UC O O O
AIM:
To conduct a direct load test on a 3-phase slip ring induction motor and to draw its performance characteristics
APPARATUS REQUIRED:
FUSE RATING-
FOR- STATOR- 125% 0f 7.5A = 10A
FOR ROTOR 125% of 11A = 15A
THEORY:
Slip ring induction motor is also called as phase wound motor. The motor is wound for as many poles as the no. of stator poles and always
wound 3- even while the stator is wound two-phase. The other three windings are brought out and connected to three insulated slip-rings
mounted on the shaft with brushes resting on them. These three brushes are further externally connected to a three phase star connected
rheostat. This makes possible the introduction of an additional resistance in the rotor circuit during starting period for increasing starting
torque of the motor.
S.NO NAME OF APPARATUS RANGE TYPE QTY.
1
Ammeter
(0-10)A MI 1
2 Voltmeter (0-600)V MI 1
3 Wattmeter (600V,10A) UPF 2
4 Tachometer Digital 1
7/31/2019 Electrical Engg CSE
84/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
PRECAUTIONS:
7/31/2019 Electrical Engg CSE
85/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
1. TPST switch is kept open initially.
2. The external resistance in the rotor circuit should be kept at max. value.
PROCEDURE:
1. Connections are given as per circuit diagram.
2. After observing precautions motor is started on no load.
3. As speed increases, the external resistance is gradually cut out.
4. The no-load readings are taken.
5. If the pointer in one of the wattmeter reverses, interchange the current coil terminals and take the reading as negative.
6. The meter readings are then noted for various load conditions.
FORMULAE USED:
1. Torque= (S1-S2)*9.81*100 N-m
2. O/P Power= 2NT/60 watts
3. I /P Power = (W1+W2) watts
4. % = (o/p power/ i/p power)*1005. %s = (Ns-N)/Ns*100
GRAPHS:
1. O/P power vs Speed
7/31/2019 Electrical Engg CSE
86/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
2. O/P power vs Torque
3. O/P Power vs
4. O/P Power vs slip
5. Torque vs Speed
6. Torque vs Slip
RESULT:
The load test on 3- slip ring induction motor was conducted and the performance characteristics curves were plotted.
7/31/2019 Electrical Engg CSE
87/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
EX.NO.
DATE: NO LOAD AND BLOCKED ROTOR TEST ON 3- PHASE INDUCTION MOTOR
7/31/2019 Electrical Engg CSE
88/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
AIM:
To conduct the no load & blocked rotor test on 3- phase induction motor & to draw the equivalent circuit of
3- Phase squirrel cage induction motor.
APPARATUS REQUIRED:-
S.NONAME OF
APPARATUSRANGE TYPE QTY
1. Voltmeter(0-600)V
(0-150)V
MI
MI
01
01
2. Ammeter (0-10)A MI 01
3. Wattmeter(600V,5A)
(150V,10A)
UPF
LPF
01
01
4. Connecting wire As required
FUSE RATING :-
125/100 * 7.5 A 10A
THEORY :-
7/31/2019 Electrical Engg CSE
89/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
A 3-phase induction motor consists of stator, rotor & other associated parts. In the stator
,a 3- phase winding (provided) are displaced in space by 120. A3- phase current is fed to the winding so that a resultant rotating magnetic
flux is generated. The rotor starts rotating due to the induction effect produced due the relative velocity between the rotor Winding & the
rotating flux.
PRECAUTIONS :-
NO LOAD TEST
(1). Initially TPST switch is kept open.
(2). Autotransformer must be kept at minimum potential position.
(3). The machine must be started at no load.
BLOCKED ROTOR TEST -
(1). initially the TPST switch is kept open.
(2). Autotransformer must be kept at minimum potential position.
(3). The machine should be started on full load.
PROCEDURE :-
NO LOAD TEST -
(1). Connections are given as per the circuit diagram.
(2). Precautions are observed and motor is started on the no load.
(3) Autotransformer is varied to have rated voltage applied
7/31/2019 Electrical Engg CSE
90/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
(3). Autotransformer is varied to have rated voltage applied.
(4). The meter readings are then tabulated.
BLOCKED ROTOR TEST :-
(1). Connections are given as per circuit diagram.
(2). Precautions are observed and motor is started on full load or blocked rotor position.
(3). Autotransformer is varied to have rated current flowing in motor.(4). The meter readings are then tabulated
FORMULA USED-
FOR NO LOAD TEST-
Wsc = 3 Vo IoCOS watts
Iw = Io cos amps
Ro= V0/ Iw
Xo= Vo/Iu
FOR BLOCKED ROTOR TEST-
Wsc =3I2*Ro watts
Ro1 = Wsc/3(Isc)2
Zo1 = Vsc/Isc Xo1 = Zo1^2-Ro1^2
7/31/2019 Electrical Engg CSE
91/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
TABULAR COLUMNS
NO LOAD TEST:
S.No Voltage Current Wattmeter readings (W1) W1 x mf1 Wattmeter readings (W2) W2 x mf2
7/31/2019 Electrical Engg CSE
92/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
S.No VoltageVoc Volts
CurrentIoc Amps
Wattmeter readings (W1) W1 x mf1 Wattmeter readings (W2) W2 x mf2Observed Reading Actual Reading Observed Reading Actual Reading
1
Voc= open circuit voltage
Ioc = open circuit current
BLOCKED ROTOR TEST:
S.No VoltageVoc Volts
CurrentIoc Amps
Wattmeter readings (W1) W1 x mf1 Wattmeter readings (W2) W2 x mf2Observed Reading Actual Reading Observed Reading Actual Reading
1
Vsc = short circuit voltage
Isc = short circuit current
RESULT:
Thus we determine the equivalent circuit of IM by using no load and blocked rotor test.
7/31/2019 Electrical Engg CSE
93/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
EXP.NO: SPEED CONTROL OF THREE PHASE SLIP RING INDUCTION MOTOR
AIM:
To conduct the speed control test on three phase slip ring induction motor.
APPARATUS REQUIRED:
7/31/2019 Electrical Engg CSE
94/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
S.No Name of the Equipment Range Type Quantity
1 Voltmeter (0-600)V MI 1
2 Ammeter (0-1)A MI 1
3 Connecting wires Required
THEORYThese motors are practically started with full line voltage applied across the stator terminals, the value of starting current is adjusted by introducing the
variable resistance in the rotor circuit. The controlling resistance is in the resistance being gradually cut out of the rotor circuit, as the motor attains rated
speed. It has been already shown that by decreasing rotor resistance, the motor attains rated speed and at the same time the starting torque is also
increased due to improvement in power factor.
PROCEDURE
1. Connections are made as per the circuit diagram.
2. Note down the resistance in each phase using Multimeter.
3. Switch ON the A.C power supply.4. Then the speed of the motor is taken for cach resistance per phase.
5. The graph was drawn between resistance and speed.
TABULAR COLUMN:
7/31/2019 Electrical Engg CSE
95/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
speed
Resistance Vs Speed
Resistance
7/31/2019 Electrical Engg CSE
96/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
RESULT
Thus the speed control of three phase slip ring induction motor was performed and the characteristics curves were drawn.
Circuit Diagram
7/31/2019 Electrical Engg CSE
97/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
NAME PLATE DETAILS
EXP.NO: Load test on single phase induction motor
AIM: To determine the efficiency of single phase capacitor start-capacitor run induction motor & to draw its performancecharacteristics.
APPARATUS REQUIRED:
7/31/2019 Electrical Engg CSE
98/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
APPARATUS REQUIRED:
S.No Name Type Range Quantity
Precautions:
1. Check for correct fuse ratings.2. Loose connections should be avoided.3. There should not be any load on the brake drum initially.
Theory:
Refer book : A text book of Electrical Technology (Volume II) B L Theraja & A K Theraja
Procedure:
Connections are made as per the circuit diagram. Supply is given to the motor by closing the DPST switch and motor is startedusing auto transformer. The no load readings of ammeter, voltmeter, wattmeter and tachometer are noted. The motor is loaded graduallyand the readings of ammeter, voltmeter, wattmeter, and spring balance, tachometer are noted and tabulated till the load current is 90% ofits rated value. Then load on the motor is released and motor is switched off.
Formulae used:
1. R = r + (t/2) (m)2. Torque (T) = 9.81 * (S1~S2) * R (Nm)
Tabulation:
1. Circumference of the brake drum = m2. Radius of the brake drum (r) = m
3. Thickness of the belt (t) = m
7/31/2019 Electrical Engg CSE
99/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
S.No
LineVoltage (V)volt
LineCurrent
(I) inampere
Inputpower
inwatt
SpringBalance
Readings inkg
Torque
(T) inNm
Speed rpm
%Slip
Outputpowerin watt
%Efficien
cy
S1 S2 S1~S2
3 . Input Power = W1 watt (wattmeter reading)4. Output power = 2NT / 60 (watt)5. %Slip = (Ns N) / Ns * 100
6. %Efficiency = (output power / Input power) * 100
7/31/2019 Electrical Engg CSE
100/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
Model Graph:
7/31/2019 Electrical Engg CSE
101/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
102/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
Result:Thus the load test on single phase induction motor is conducted and its performance characteristics were drawn.
7/31/2019 Electrical Engg CSE
103/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
104/112
7/31/2019 Electrical Engg CSE
105/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
106/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
STUDY OF THREE PHASE INDUCTION MOTOR STARTERS(B) AIM:To study about the AC motor starter.
THREE PHASE INDUCTION MOTOR STARTERS:1. AUTO TRANSFORMERS:It is also known as autotransformers or compensator It consists of an autotransformers with necessary switches or three phase
7/31/2019 Electrical Engg CSE
107/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
It is also known as autotransformers or compensator. It consists of an autotransformers with necessary switches or three phasetransformers reduced voltage is applied to the motor when the motor pick up 80%. So, that the transformer is out-out and full voltage isgiven to the motor most of the autotransformer are provided with 3 sets of tops so as to reduce the voltage to 85, 60 up to 50% of the linevoltage. Again the autotransformer starter may also be provided with stop overload protection and interlocks. The completer scheme of thestarter also included.(a) Interlocks to ensure reduced voltage starting.
(b) Protection against over load etc..,2. STAR DELTA STARTER:The three phase induction motor to be started with the help of the star delta starter must hae its six terminals of the stator winding available.(A1 A2), (B1 B2), (C1 C2). Thus for a 415v across each phase of the stator winding during running.The stator winding is connected instar during starting. Thus for a 415v each winding phase gets 415/_3 = 230V. The starting current is thus reduced in the same proportion (1: _3) and the starting torque isreduce to 1 : 1/_3 compared with the values with full starting. Thus a reduced voltage is applied to the motor during starting.After the motorstarts and attains speed. The connections are changed to delta with the help of the stator and the motor operations at full voltage andhence runs under normal conditions. The star delta starters has the reconnecting arrangement and in addition it has the following features.1. An interlock to prevent direct switching to delta position.2. A push button (or) knob to stop from running condition. After operating this, the switch isbrought to the OFF position.3. An over load protection
7/31/2019 Electrical Engg CSE
108/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
.
This method is used in the case of the motor which one built t run normally with a delta connected starter winding. It consists of two wayswitch connect the motor in star for starting and then delta for normal running. The star connected applied voltage by a factor of 1/_3 andhence the torque developedbecause 1/_3 of that of which would have been developed if the motor war directly connected in the delta. The three types of star delta
starters are:1. Hand Operated2. Semi Automatic
7/31/2019 Electrical Engg CSE
109/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
3. Fully Automatic3. DIRECT ON LINE STARTER (or) D.O.L. STARTER:When fully voltage is supplied across the starters of indction motor, lot of current in drawn by the winding. This is because at the time ofstarting the induction motor are started using direct on line starter on heavy starting curent will flow through the winding such as heavystarting current of short duration may not cause to the motor. Since the construction of induction motor are rugged. More over it takes time
for temperature rise to endanger the utilization of motor windings. But this heavy impression current will cause large voltage drop with thelinear during the period of motor A direct alternate method at starting of induction motor is application up to starting of induction motor. TheON push button is pressed coil A becomes energized and if open contacts are closed when OFF button push button is pressed in a will getenergized and main contacts of the conductor open when themotor starts, in case of overload on the motor the contact of over load may be opened and sub sequently the motor will stop. In case ofover load the overload relay also opens the circuit of the coil and the contactor opens. In case of a supply failure while the motor is running,the coil is deenergized and the motor is isolated from the supply lines. After the supply is resumed the operator has to operate the startpush button for running the motor
7/31/2019 Electrical Engg CSE
110/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
111/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
7/31/2019 Electrical Engg CSE
112/112
Department of EEE, Chennai Institute of Engineering, Kundrathur
RESULT:Thus the DC and AC Motor starters were studied.