Download - DORO LUCENT Headrest System  · DORO LUCENT® Headrest System The DORO LUCENT® Headrest System is the cranial stabilization system of choice for all procedures applying X-Ray, DSA

Transcript

www.pmisurgical.com DORO LUCENT® Headrest System

DORO LUCENT® Headrest System

The DORO LUCENT® Headrest System is the cranial stabilization system of choice for all procedures applying X-Ray, DSA and iCT imaging. The system is highly adaptable to the surgeon’s needs and meets the demands of today’s intraoperative imaging procedures.

The system features the proven, completely metal free DORO® Skull Clamp Radiolucent with its beneficial Quick-Rail® inter faces for easy attachment of navigation tracking devices, retractor systems and other accessories.

The DORO LUCENT® Base Unit features a completely new and stre-amlined design. With a clear focus on stability, usability, cleanability and radiolucency, this base unit provides a solid foundation for all X-Ray, DSA and iCT imaging supported procedures.

DORO LUCENT® Headrest System, item no. 1101.020

Rigid fixationof the patient with the provenDORO® Skull Clamp Radiolucent. Item no. 3034-00

Quick-Rail®on both sides for secure and easy attachment of DORO® Navigation Adaptors or Retractor Systems.

DORO LUNA® Retractor System DORO COBRA® Flexible Rotary Arms

DORO LUCENT®

Navigation AdaptorsStryker®, Medtronic, Brainlab

Secure and easy attachmentof DORO® Navigation Adaptors or Retractor Systems with Quick-Rail® technology on both sides.

DORO LUCENT®

Disposable Skull Pinreduces imaging artifacts to a minimum. Item no. 1106.003 (3 pins)Item no. 1106.103 (9 pins)

Designed for cleaningThe base unit can be disassembled and machine washed.

Compatibilitywith all common OR tables.

Optimized for iCTimaging procedures.

Maximized stabilitythrough formfitting design.

Combined lockingof Transitional- and Sliding Member.

Depending on the surgical needs, aluminum and radiolucent parts can be exchanged against each other.

Configuration ACervical spine Applications

Configuration BCranial and cervical spine applications with CT, DSA, Fluoroscopy

Configuration CCranial applications with C-Arms,DSA, Fluoroscopy

Optimized for imagingLong reach into gantry.

Mix & Match

www.pmisurgical.com

Headquarters Germanypro med instruments GmbH | Bötzinger Straße 38 | 79111 Freiburg, Germany Phone +49 761 384 222 10 | E-mail [email protected]

US Subsidiarypro med instruments, Inc. | 4529 S.E. 16th Place, Suite 101 | Cape Coral, FL 33904 Toll Free 877 225 4086 | E-mail [email protected]

Version 02 © 2018 pro med instruments GmbH, Freiburg, Germany. All rights reserved.

The information has been compiled with utmost care. Errors can, however, not be excluded. Errors do not entitle to any legal claims. We reserve the right to modify the products at any time.

Alternative set ups

Set up with DORO LUCENT® Horseshoe Headrest ENTItem no. 1101.007 (adult)Item no. 1101.008 (pediatric)

Set up with DORO® Horseshoe RS Headrest RadiolucentItem no. 3036-70 (adult)Item no. 3035-70 (pediatric)

Set up with DORO® Swivel Horseshoe Headrest RadiolucentItem no. 3036-00 (adult)Item no. 3035-00 (pediatric)

The DORO LUCENT® Headrest System comes in a DORO LUCENT® Storage Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . Item no. 1101.030

Content:DORO LUCENT® Base Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Item no. 1101.021DORO LUCENT® Locking Transitional Member . . . . . . . . . . . . . . Item no. 1101.031DORO LUCENT® Transitional Member . . . . . . . . . . . . . . . . . . . . . Item no. 1101.026DORO® Swivel Adaptor Radiolucent. . . . . . . . . . . . . . . . . . . . . . . . Item no. 3033-00DORO® Skull Clamp Radiolucent . . . . . . . . . . . . . . . . . . . . . . . . . . Item no. 3034-00DORO LUCENT® Disposable Skull Pins, Adult . . . . . . . . . . . . . . . . Item no. 1106.003

DORO LUCENT® Headrest System Item no. 1101.020