SIGMA MRL E1000
Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Document Revision
(Remark: Any modification of SEB content will be not informed in advance.)
Document Revision
Revision Comment Issued Date Approved Date
00 new document for all previous
versions Yanchunming 2011-08-23 Xuyong 2011-08-23
01
Change the speed from 0.63 to 0.5
Change HWmin(550/630kg) from 1875
to 1900.
Yanchunming 2012-05-30 Xuyong 2012-05-30
02 P22,change ISC function from option
to standard lizhigang 2012-9-29 Xuyong 2012-9-29
03 Add hoistway HW & HD Max lizhigang 2012-10-15 Dongdawei 2012-10-15
04
P14 Enclose panel add
hairline304/SCME /SCME-hairline304
P14 Door jamb add hairline304
P14 Front add hairline304/mirror
P16 Car door add hairline304/mirror
P18 hoistway door add SCME
Change E1000 to SIGMA MRL E1000
lizhigang 2013-1-15 Dongdawei 2013-01-15
05
Add (mirror DL>450KG) to optional
decoration of car ceiling in C-EL1 &
C-EL2
Add mirror to HR02 for handrail type
Add remark for hoistway lighting
Revise the description about car fan &
light power controlling in standard
functions
Revise power supply for SIGMA MRL
E1000
Huzhimin 2013-03-18 Dongdawei 2013-03-18
06 Added the adorning thickness P18 Huzhimin 2013-09-04 Dongdawei 2013-09-04
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 1 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
SIGMA MRL E1000 SEB
Standard Equipment Binder
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 2 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
CONTENTS
1. Description of the Integral Product 3
2. Elevator Integral Components and Illustration 9
3. Performance 22
4. Executive Standards and Codes 22
5. Function Introduction 23
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 3 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
1. Description of the Integral Product
Commercial Name: SIGMA MRL E1000
Original Source of the Product:
SIGMA MRL E1000 series are manufactured by Express Elevator CO. Ltd.
SIGMA MRL E1000 Series Model codes:
P0450G05D-CO P0450G10D-CO -- --
-- P0550G10D-CO P0550G15D-CO P0550G17D-CO
-- P0630G10D-CO P0630G15D-CO P0630G17D-CO
-- P0800G10W-CO P0800G15W-CO P0800G17W-CO
-- P1000G10W-CO P1000G15W-CO P1000G17W-CO
P0250G05D-2S P0250G10D-2S -- --
P0320G05D-2S P0320G10D-2S -- --
P0450G05D-2S P0450G10D-2S -- --
-- P0550G10D-2S P0550G15D-2S P0550G17D-2S
-- P0630G10D-2S P0630G15D-2S P0630G17D-2S
-- P0800G10D-2S P0800G15D-2S P0800G17D-2S
-- P1000G10D-2S P1000G15D-2S P1000G17D-2S
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 4 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
Explanation For The Model Codes:
SIGMA MRL E1000 model code is composed of 11 characters.
Numerical digit1: indicates the type of the elevator (P means passenger lift)
Numerical digit 2-5: means the duty load.
For example, 0630 means that the duty load is 630kg.
1000 means the duty load is 1000kg.
Numerical digit 6: executive code and standards.
G means GB series.
Numerical digit 7& 8: brief mark of rated speed.
06-0.63m/s; 10-1.0m/s; 15-1.5m/s; 17-1.75m/s;
Numerical digit 9: car size. W – wide car; D– deep car.
Numerical digit 10-11: door type.
standard:CO---center opening; 2S---side opeining
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 5 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
For example:
P 1000 G 15 W CO
Center opening
Wide car
Rated Speed 1.5m/s
GB series
Duty load is 1000kg
Passenger lift
SIGMA MRL E1000 Duty Load, Passengers and Car Dimensions
Center Opening
Side Opening
Duty Load
(kg)
DL
Passengers
NBPAS
Car inside dimension (mm)
CARSZ
Width
CW
Depth
CD
450 6 1000 1100
550 7 1100 1300
630 8 1100 1400
800 10 1400 1350
1000 13 1600 1400
Duty Load
(kg)
DL
Passengers
NBPAS
Car inside dimension (mm)
CARSZ
Width
CW
Depth
CD
250 3 800 900
320 4 900 1000
450 6 1000 1100
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 6 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
SIGMA MRL E1000 Rated Speed
Load
(kg)
DL
Passengers
NBPAS
Speed
(m/s)
V
250 3 0.5 1.0 N/A N/A
320 4 0.5 1.0 N/A N/A
450 6 0.5 1.0 N/A N/A
550 7 N/A 1.0 1.5 1.75
630 8 N/A 1.0 1.5 1.75
800 10 N/A 1.0 1.5 1.75
1000 13 N/A 1.0 1.5 1.75
SIGMA MRL E1000 Max. Rise and Max. Stops
Duty Load
(kg)
DL
Speed
(m/s)
V
Maximum extra weight
for local linings
(kg)
MAXWT 0.5 1.0
250-450
30m 30m
100 FCL FCL
10 stops 10 stops
Duty Load
(kg)
DL
Speed
(m/s)
V
Maximum extra
weight for local
linings
(kg)
MAXWT 1.0 1.5 1.75
550-1000
60m 75m 90m
200 FCL FCL FCL
20 stops 24 stops 30 stops
If the decorative weight is over standard, contract engineering is must.
550 7 1100 1300
630 8 1100 1400
800 10 1200 1500
1000 13 1100 2100
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 7 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
Max. Number of elevators in group control
Elevator
Type
ELVTYPE
Speed
m/s
Number of
elevators in group
control
SIGMA MRL
E1000
0.5
4 1.0
1.5
1.75
The Minimum Rise For Elevator To Reach Rated Speed
Elevator Type
ELVTYPE
Speed
(m/s)
V
The minimum rise
for elevator to
reach rated
speed(m)
SIGMA MRL
E1000
0.5 4
1.0 5
1.5 6
1.75 7
Minimum Floor Height
Elevator Type
ELVTYPE
Door opening
height(mm)
OPH
Single door
(mm)
Minimum distance
between front & rear
door panles
(mm)
SIGMA MRL
E1000 2100 2700 600
Motion Control Type and Drive System
Type
ELVTYPE Model
Load
(kg)
DL
Passengers
NBPAS
Speed
(m/s)
V
SIGMA MRL
E1000
P0250G05D 250 3
0.5
P0250G10D 1.0
P0320G05D 320 4 0.5
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 8 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
P0320G10D 1.0
P0450G05D 450 6
0.5
P0450G10D 1.0
P0550G10D
550 7
1.0
P0550G15D 1.5
P0550G17D 1.75
P0630G10D
630 8
1.0
P0630G15D 1.5
P0630G17D 1.75
P0800G10W/D
800 10
1.0
P0800G15W/D 1.5
P0800G17W/D 1.75
P1000G10W/D
1000 13
1.0
P1000G15W/D 1.5
P1000G17W/D 1.75
Power Supply for SIGMA MRL E1000
Main Power(VAC)
3 phase
Light power(VAC)
1 phase Frequency(Hz)
Standard Voltage 380±7% 220±7% 50/60
Optional Voltage
380±7% 230±7% 50/60
415±7% 240±7% 50/60
400±7% 220±7% 50/60
400±7% 230±7% 50/60
400±7% 240±7% 50/60
208±7% 110±7% 50/60
220±7% 110±7% 50/60
208±7% 120±7% 50/60
Arrangement of Machine Room
Machine location: without machine room
Machine type: gearless machine
Roping factor: 2:1
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 9 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
2. Elevator Integral Components and Illustration
Equipments In Machine Room
1. Controller
SIGMA MRL E1000 controller is EXP-MCS-5
2.EXP-GM VTR Machine, Motor, Coder
3. Machine standand beam
Welded channel steel & “H” steel are used for SIGMA MRL E1000, including isolation pad &
installation parts.
4. Governor
According to speed and rise, the following types of governor are selected for SIGMA MRL E1000.
Model
Load
(kg)
DL
Speed
(m/s)
V
Machine
Rated
rotate
Speed
(rpm/min.)
Roping
Ratio
Sheave
Diameter
(mm)
Groove Undercut
Kinds
Deflection
Pulley
Motor
Power
(kW)
P0250G05D 250
0.5
KDS
58
2:1
330 3
U
Without
1.1
P0250G10D 1.0 116 330 3 2.2
P0320G05D 320
0.5 58 330 3 1.1
P0320G10D 1.0 116 330 3 2.2
P0450G05D 450
0.5 58 330 4 1.5
P0450G10D 1.0 116 330 4 3.0
P0550G10D
550
1.0
GTW8
96 400
4
Without
4.5
P0550G15D 1.5 144 400 6.8
P0550G17D 1.75 167 400 7.9
P0630G10D
630
1.0 96 400
4
4.5
P0630G15D 1.5 144 400 6.8
P0630G17D 1.75 167 400 7.9
P0800G10W/D
800
1.0 96 400
4
5.5
P0800G15W/D 1.5 144 400 8.3
P0800G17W/D 1.75 167 400 9.6
P1000G10W/D
1000
1.0 96 400
5
6.7
P1000G15W/D 1.5 144 400 10
P1000G17W/D 1.75 167 400 11.7
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 10 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
The detailed information is shown in the following form:
Load
(kg)
DL
Rope Dia
(mm)
250~1000 6.3
5. Rope Fastening
SIGMA MRL E1000 has hitch plates that are mounted in the overhead. The rope fastening
type is wedge-shape, so that it is convenient for installation and the rope length can be
adjusted.
6. Switches
SIGMA supplies the switches including main power switch, car lighting switch, hoistway
lighting switch and breaker with creepage protection. Different specifications can be chosen
according to the different working current.
7. Headroom wiring
SIGMA MRL E1000 headroom wirings are supplied by Express, which include the wiring
connection:
Main power switch------Controller
Lighting switches------Controller
Controller------Motor brake
Controller------Coder
Controller------Speed governor
Controller------Handwheel switch
8. Safety Marks
Every unit of SIGMA MRL E1000 elevator provides a set of safety marks in order to comply
with SIGMA WWJSSS standard.
9. Others
The hooks, lightings, ventilation, daylight and temperature-control devices in hoistway and
steel used for pre-installation are prepared by customers.
Hoistway Equipment
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 11 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
1. Guide Rail
The guide rail complies with ISO standard and Chinese construction professional standard.
The specification of guide rails used are shown in the form as below:
Load
(kg)
DL
Speed
(m/s)
V
Guide rail Model CWT Rail
Arrangement Car side
(linear density kg/m)
Counterweight side
(linear density kg/m)
250
0.5/1.0
T82 TK3A
Side
arrangement
320 T82 TK3A
450 T82 TK3A
550
1.0/1.5/1.75
T89 TK3A
630 T89 TK3A
800 T89 TK3A
1000 T89 TK3A
Note: CAR rail is solid type, CWT rail is hollow type.
2. Rail Brackets
The rail brackets of SIGMA MRL E1000 are welded rail brackets and are adjusted by cutting
at jobsite. The rail brackets can be adjusted according to the hoistway size.The rail bracket
spacing is 2000mm.
3. Guide Rail Stand
SIGMA MRL E1000 rail stand is bending plate.
4. Buffer
Please refer to SIGMA MRL E1000 technical specification table for the detail specifications
of buffer.
Speed
(m/s)
V
Buffer
Type
0.5 Polyurethane
Buffer
1.0 Polyurethane
Buffer
1.5 Oil Buffer
1.75 Oil Buffer
5. Buffer Stand
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 12 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
SIGMA MRL E1000 provides buffer stands according to pit depth. It uses bending plate
structure. Please refer to layout drawing for the pit depth.
6. Governor Tension Device
If the maximum rise is below or equal to 60m, the governor rope tension weight is 30kg. If
the maximum rise is above 60m and below or equal to 90m, the tension weight is 48kg.
7. Cunterweight
Load
(kg)
DL
Speed
(m/s)
V
DBG(mm)
Filler Sheave
Diamete
r
(mm)
Guide
Rail
Type
CWT Width
(mm) Weight
(kg)
Width
(mm)
250 0.5/
1.0 600 23 190 330
Slide
Guide
330 320
450
550 1.0/
1.5/
1.75
1000 48 208 400 208 630
800
1000
Note: Above is based on standard filler, but iron filler could be applied as deviation.
8. Pit Material
The pit material consists of pit lighting, emergency stop switch, hoistway lighting switch. All
the wirings adopt AMP quick-assembly connectors.
9. Traction Rope & Governor Rope
Traction rope use 10mm steel wire rope.(When DL<=450kg, the rope is 8mm)
governor rope use 6.3mm steel wire rope.
10. Hoistway lighting
Lamps are provided along the hoistway with a spacing of 7m.
Two lamps have to be placed at 0.5m above top of hoistway and 0.5m above pit respectively
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 13 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
The lighting switch is set in the controller and pit respectively.
Remark : If lighting power isn’t 220VAC, factory supply hoistway lamp wire, local should
provide hoistway lamps & lamps holders.
11. Compensation Chain
The immersion plastics chain is used for SIGMA MRL E1000.
Car
1. Car Frame
SIGMA MRL E1000 car frame is shaped with bending sheet and bolts assembled. It includes
platform support frame. The platform support frame can be used as installation platform
when installation.
Crosshead Hitch
Safety Block is assembled at foot of frame. It is manufactured according to SIGMA
Specification.
Guide shoe, select sliding guide.
The balance weight to be used if required.
2. Platform
The platform of SIGMA MRL E1000 is shown in the below figure.
The enclosure is assembled at the side of platform with pop nut and bolts. The car threshold
is made of aluminum alloy with dust holes left. The thickness of floor decoration is 3mm, and
the process of standard floor decoration is sticking wood board on floor sheet and then
sticking floor hide (FL01M, FL02M, FL03M, FL04M, FL05M, FL06M, FL07M, FL08M). There
are no floor tile and wooden plate in the optional decoration, The thickness of floor
decoration is 30mm.
SIGMA MRL E1000 uses mechanical three points weighting device with micro-action switch.
3. Top of car Protection
Protection rails
The middle pole is at the position of half height.
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 14 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
4. Enclosure Panel, SCME-hairline443,SCME Ceiling, Car Door, Header, Hanger, and Door
Operator
Components Standard Option
Enclosure
panel
Bending shaped
Welded steel stiffener at back, painted surface
With visible ventilation hole at the bottom of front
panel
Hairline 443/Hairline304/
SCME-hairline443/SCME
[EST002] ;[EST003] ;[EST004] ;[
EST005] ;[EST006] ;[EST007] ;[
EST008] ;[EST009] ;[EST010] ;[
EST011] ;[EST012] ;[EST013] ;[
EST014] ;[EST015]
NOTE :
Only open type is CO ,
SCME /SCME-hairline443 can
choose
8 colors to select:
P-001, P-002, P-003, P-004, P-005, P-006, P-007,
P-010
SCME
–hairline443 --------
NOTE:
When choose SCME
–hairline443 type, front
panel must be hairline443
SCME -------
NOTE:
When choose SCME type, front
panel must be mirror
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 15 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
Door jamb The color of ordinary steel door jamb is same with
enclosure panel. Hairline 443/hairline304
Front panel Same color with enclosure panel.
Without second COP cutout.
Hairline443/hairline304/mirror
NOTE: Mirror only use when
choose SCME type, otherwise
Mirror can’t choose
Height of car Inside height = 2300mm Inside height =2400mm
Ventilation Install a cross-flowing blower on top of car.
Standard disposition is one set. -----
Lighting C-ES1 type ceiling with lamps for lighting.. -----
Emergency lighting device is standard equipment. -----
Car roof
C-ES1 type ceiling without suspend ceiling, sprayed
& painted (8 colors available are same as enclosure
wall)
C-EL1(Mirror DL>450KG) type
with decorative ceiling
C-EL2(Mirror DL>450KG) type
with decorative ceiling.
Emergency
exit ----- With emergency exit
Handrail -----
HR-04 stainless steel mirror
single tube
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 16 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
-----
HR-02 stainless steel mirror
double tube
Car door
protective
device
2D light curtain -----
Car door Steel painted, same as enclosure
Hairline443/Hairline304/MIrror
NOTE:
1:When choose SCME
–hairline443 type,Car door must
be Hairline443
2:When choose SCME type,Car
door must be Mirror, otherwise
Mirror can’t choose
Header and
hanger
Structural lintel with door operator pre-mounted.
Hanger is assembled on header. -----
Door operator Use manufacturer’s variable frequency door
operator. -----
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 17 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
5.Car and Hall Signal Fixtures
Components Standard
Hall Call
HB/HPI
VIL-EM1C
Car operation panel
COP
CBM-EM1C
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 18 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
Position Reference system
Model & speed
(m/s)
Functio
n
Material Type Location
1.0&1.5&1.75
Control system
PRS
FLS
Sensor On crosshead of car
Limit switch On brackets supported by the guide
rails
Limit switch cam On brackets supported by the car
frame uprights
Hoistway door system
Components & funciton Standard Option
Door panel
Ordinary painting sheet Hair
Hairline443/Hairline304/SCME
[EST002] ;[EST003] ;[EST004] ;[E
ST005] ;[EST006] ;
[EST007] ;[EST008] ;[EST009] ;[E
ST010] ;[EST011]
;[EST012] ;[EST013] ;[EST014] ;[E
ST015]
NOTE : Only open type is CO , SCME
can choose
Painted color:
P-001, P-002, P-003, P-004, P-005,
P-006, P-007, P-010
Door panel fire protection
request Non-fireproofing Fire-proofing door
Entrance frame
Ordinary painting sheet
Hair Hair-line stainless steel Painted color:
P-001, P-002, P-003, P-004, P-005,
P-006, P-007, P-010
Sill Aluminum alloy sill ----
Landing adorning thickness
Standard adorning thickness Optional
≤80mm 80<Landing adorning thickness≤150mm
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 19 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
Layout Feature and Hoistway Dimension
Feature Limitation Use for
Machine location Without machine room
Roping factor 2:1
CWT location Side All models
Door service Only front door
Floor height Min. 2700 mm
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 20 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
Dimension of hoistway
HW
HD
Load
(kg)
DL
Car
spec.
HW
Min. size
(mm)
HW
Max. size
(mm)
HD
Min. size
(mm)
HD
Max. size
(mm)
Opening
type
Door opening size
(width*depth) mm
250 Deep car 1450 1770 1300 1650 2S 700X2100
320 Deep car 1550 1870 1350 1700 2S 700X2100
450 Deep car 1650 1970 1450 1800 CO 700X2100
450 Deep car 1650 1970 1450 1800 2S 800X2100
550 Deep car 1900 2180 1700 2200 CO 800X2100
550 Deep car 1850 2180 1750 2250 2S 800X2100
630 Deep car 1900 2180 1800 2300 CO 800X2100
630 Deep car 1850 2180 1850 2350 2S 900X2100
800 Wide car 2150 2480 1750 2250 CO 800X2100
800 Deep car 1950 2280 1950 2450 2S 900X2100
1000 Wide car 2350 2680 1800 2300 CO 900X2100
1000 Deep car 1850 2180 2550 3050 2S 900X2100
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 21 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
Dimension of vertical profile
R = rise,unit: m
K: Overhead
S: Pit depth
Load
(kg)
DL
Speed
(m/s)
V
CH size
(mm)
K min. size
(mm)
S min. size
(mm)
250~450kg 0.5~1.0 2300 3800
1250 2400 3900
550~1000kg
1.0 2300 3800
1350 2400 3900
1.5 2300 3950
1500 2400 4050
1.75 2300 4000
1500 2400 4100
Note: Please contact with our factory, if the size of ”CH size” don’t contain in this table.
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 22 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
3. Performance
SIGMA MRL E1000 Performance
Speed tolerance ±5%
Car vertical vibration 25 mg
car horizontal
vibration15 mg
one meter from sound source
one meter from ground
Max. door noise <=65 dB(A)
Leveling accuracy ± 5 mm
<=55 dB(A) (fans off)
<=70 dB(A)
In center of car and 1 meter high
from ground of car
Standard
Peak value to peak value,
measured with PMT instrument
Instrument or test method
Noise in machine
room(max.)
Max. noise in car
4. Executive Standards and Codes
GB 7588-2003
The SIGMA Worldwide Job-site Safety Standard ( WWJSSS )
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 23 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
5. Function Introduction
S for Standard ,O for Optional
Fundtion
code Function name
Usefulne
ss Function introduction Notes
FCL Full collective
operation S
All registered car & hall calls will be answered in the
sequence by which the elvator cars approaches the
landings. The travel direction of car will be determined by
the first registered car or hall call.
Top of car
inspection &
machine room
inspection
S
Inspection operation switches, inspection buttons &
emergency stop device are provided at car top &
machine room. Car top inspection has priority over
machine room inspection. When inspection mode is
started, only inspection operation is allowed.
ECU Emergency car
light S
When the normal lighting power fails, the emergency
lingting works.
CHT
Separate Car and
Hall Call Door
Times
S The time of door retaining open for answering hall call
and car call can be adjusted separately.
LNS Load non stop S
When a car is loaded to a presetted percentage of its
rated load, it is considered as “full”,.the car will bypass
further hall calls. The hall calls will be registered and will
be anwered on next trip (single),or by another car(group).
ARD Automatic return
to main floor S
Main stop may be set according to real need of buildings
for single elevator. Car will automatically return to main
stop if no call is registered during presetted time, and
door remains close before answering futher hall call.
Main stop is usually at busy-traffic floors or ground floor.
Fan manual &
light automatic
switching
S
The car fan is controlled by COP switch and the light
power is controlled by software according to running
status of the elevator
Faulty automatic
detection S The system will automatically detect faulty
DTP
Door closing
overtime
protection
S
When the door can’t close properly within persetted time
due to mechanical barriers or other reasons, elevators
will not in operation if no door-closed signal is detected
after door repeats closing for three times.
OLD Overload warning S When the car is overloaded, the alarm light and buzzer
works. Then overloading is indicated , car door will not
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 24 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
close, and elevator will not operate.
TRIC Trip counter S
A counter is arranged in elevator control cabinet to count
times elevator oerates for the convenience of
maintanence.
Alarm Bell S For passengers in special case to press alarming
buttonin to inform outside in time.
HPI
/CPI
Hall & car
position indicator S
A digital number is displayed on the COP and landing call
box indicated for passengers to know the car position in
the hoistway.
HTTL
/CTTL
Hall & car call
register S
When the hall call or car call is registered, the button LED
illuminates.
HDI
/CDI
Hall & car
direction indicator S
To be convenient for passengers to learn the operation
direction of car, arrowhead indicator lamp to indicate
operation direction is arranged on car operation panel
and hall calling faceplate.
Light curtain S Light curtain is provided as door closing safety device.
ICU
Intercom
between security
room and car /
machine room
S
Intercom between surveillance room and machine room
and car(including car top/pit) is offered, effective still at
power failure.
EFO Emergency
firemen operation S
When fireman switch is on , the system will cancel all
calls, drive elevators to return to fire-fighting floor directly,
opens door to release passengers and stop operation
Emergency
rescue in
controller
S When elevator encounters barriers, operate the
emergency rescue in controller to rescue the passengers.
DOB/DCB Door open &
close button S
Micro-button has been set in the operation panel in the
car, in order to help passengers control the time to open
or close the door according to their demands.
ISC Independent
service S
When elevator stays at independent service, which has
ben designed to meet special needs of customers, it will
no longer answer calls from out of hoistway but only
operate, close & open door under manual control.
PKS Parking
Operation O
Each elevator will have a key switch 'PKS' at a
designated landing (e.g., at the lobby). By this feature, a
particular car may be commanded by its key switch to the
designated landing.
ATT Attendant service O The Attendant Operation feature allows semi-automatic
operation with manual control.
RLEV Relevelling O Stopping errors shall be corrected by relevelling. The size
SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB
Revision: 06
Page: 25 / 25 Standard Equipment
Binder
(Remark: Any modification of SEB content will be not informed in advance.)
operation of a possible stopping error depends on the type of drive
and the accuracy of the position sensors.
GNC Gong in car O
A chime installed on car top will ring when the car
approaches landing to remind passengers that they have
arrived at the destination floor.
CCTVC CCTV cable O CCTV cable from car to machine room is offered
Voice Synthesis O
When the car arrives at floor or ready to move, the
system will announce about the floor number and running
direction by artificial voice.
ANS Anti-Nuisance O
If there is only one passenger in the car and an excessive
number of car calls is registered, such nuisance is
detected and all car calls will be canceled, requiring
registration of a proper number of calls.
Fire Alarm Home
Landing O
When gire alarm system in a building is actirated, the car
will return to appointed floor immediately. And send
such signal to customer.
BA Interface O
By using a contact the elevator signal such as floor,
up-down, fault, over-load, fire alarm etc. will be sent to
custome Building Automation room.
Elevator
Supervisory
Panel
O
Monitor panel will be provided, and the elevator
operation situaiton ( running , overload, door opening,
fire alarm, fault ) will be monitored
Elevator Monitor
System With PC O
By PC system, to monitor the elevator operartion,
including floor , running direction, door opening.,
overload, fire alarm, fault
ARED
Automatc
Emergency
Rescue Device
O
When the power failure come suddenly, if the elevator
has not arrived at the appointed foor, the ARED device
will activate the car to reach nearest floor and open the
door; if the car already arrived at the floor, the door will
open by ARED
THB Machine
Overheat Protect O
Once the machine temperature is over 120℃, the
elevator will out of service after this run. When the
machine temperature is below 120℃, the elevator will
become normal accordingly.