PROPOSED SEGMENTAL RETAINING WALLS (SRW)
Project No:
Date:
Drawn By:
Reviewed By:REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY):
This item has been electronically signed and
sealed by Jon Huyck, PE on May 30, 2017 using a
Digital Signature.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
® &
™
A
NC
HO
R W
AL
L S
YS
TE
MS
, IN
C
5959 BAKER ROAD, SUITE 390
MINNETONKA, MN 55345-5996
PHONE: (952) 933-8855
ANCHOR WALL ENGINEERING, LLC
DESIGN ENGINEER: JON C. HUYCK
FLORIDA REGISTRATION: 61043
CERT. OF AUTHORIZATION: 27077
WW
W.A
NC
HO
RW
AL
L.C
OM
Scale:
0 1
VERIFY THAT THE BAR ABOVE IS 1". IF NOT,
ADJUST THE SCALE ACCORDINGLY.
NOT TO SCALE
PART 1 GENERAL NOTES & SPECIFICATIONS
1.01 SUMMARY
A. Section Includes
Work includes furnishing and installing Anchor Diamond Pro
®
PS modular retaining wall units with soil reinforcement to the lines
and grades designated on the construction drawings in accordance with FDOT Specification 548.
B. Design Parameters
1. Reinforced/Backfill Soil: Angle of Internal Friction = 30-degrees, Unit Weight = 105 pcf
2. Retained Soil: Angle of Internal Friction = 30-degrees, Unit Weight = 105 pcf
3. Foundation Soil: Angle of Internal Friction = 30-degrees, Unit Weight = 105 pcf
4. Designed in accordance with:
4.a. AASHTO LRFD Bridge Design Specifications, Applicable edition for the project.
4.b. FDOT Structure Design Guidelines, Applicable edition for the project.
4.c. Federal Highway Administration: FHWA-NHI-10, Volumes 1 and 2, 2009
1.02 REFERENCES
A. Florida Department of Transportation
1. Florida Sampling and Testing Methods
2. FDOT Section 548; Retaining Wall Systems
3. FDOT Section 985; Geosynthetic Materials
4. FDOT Section 901; Coarse Aggregate
1.03 DELIVERY, STORAGE AND HANDLING
A. The contractor shall check the materials upon delivery to assure that proper material has been received.
B. Deliver and handle materials in such a manner as to prevent damage. Store above ground on wood pallets or blocking. Remove
damaged or otherwise unsuitable material, when so determined, from the site.
C. The contractor shall prevent mud, wet cement, epoxy and like material, from coming in contact with the modular units and
reinforcement.
D. Geosynthetic materials shall remain in protective wrapping until placed in the wall. Follow manufacturer's recommendations
regarding protection from direct sunlight.
E. Alignment pins shall remain in boxes until placed in the modular units. Alignment pins exposed to direct sunlight for a period
exceeding 2 months should not be used in the constructed wall.
PROPOSED SEGMENTAL RETAINING WALL:
DIAMOND PRO PIN SYSTEM
FOR FDOT APPLICATIONS
SAMPLE DRAWINGS
1.04 DEFINITIONS
A Geosynthetic Reinforcement is a material specifically fabricated for use as soil reinforcement.
B. Diamond Pro
®
PS modular retaining wall units are machine made from portland cement, water, mineral aggregates
and potentially fly ash and various admixtures.
C. Permeable Material is a free draining material used as a drainage media.
D. Reinforced Backfill Soil is the soil used as fill within the geosynthetic reinforced soil mass.
E. Foundation Soil is the soil mass supporting the leveling pad and reinforced soil zone of the segmental block retaining
wall system.
F. Wall Subdrain is a perforated PVC pipe, generally of 4 inch (100 mm) diameter, used to drain water from soil.
G. Filter Fabric is a non-woven geosynthetic material used for filtration/separation and to allow for the long term passage
of water into a subsurface drain system while retaining the in situ soil. Fabric shall be in accordance with Standard
Specifications Section 985.
H. The Diamond Pro
®
PS Pins are a specifically manufactured polymer based material, supplied by Anchor, and used to
mechanically connect/align the Diamond Pro
®
PS units.
1.05 SUBMITTALS
A. Submit the following to the Engineer:
1. Manufacturer's literature: Materials description
2. Shop drawings: Retaining wall system design, including wall heights, geosynthetic reinforcement layout, drainage
provisions and other pertinent details. The shop drawings shall be signed by a registered professional engineer
licensed in the state of Florida.
3. Certificate of Compliance letter in accordance with FDOT Section 548 (Retaining Wall Systems).
4. Design calculations demonstrating satisfaction of Capacity Demand Ratio for: Internal stability of the wall
systems.
PART 2 PRODUCTS
2.01 MATERIALS
A. Modular Block Facing Unit: "Diamond Pro Pin System" (DPPS) as manufactured under license from Anchor Wall
Systems. No substitutions allowed. Diamond Pro
®
PS units shall meet requirements of ASTM C1372 except as
modified by FHWA NHI-00-043, section 8.10.
1. Unit height dimensions shall not vary more than +/-1/16 inch (1.6mm) from that specified.
2. Unit length dimensions shall not vary more than +/-1/8 inch (3.2mm) from that specified.
3. Minimum required compressive strength shall be 4,000 psi (28Mpa).
4. Maximum absorption shall be 6.5%.
5. Color: ________. Submit a block sample for approval by the resident engineer.
6. Texture: Split Face.
7. The concrete units shall include a fiberglass pin connection/location device.
B. Geosynthetic reinforcement: Mirafi Miragrid 3XT, 5XT & 8XT. No substitutions allowed.
C. Connectors: The Diamond Pro
®
PS pins as supplied by Anchor Wall Systems shall be manufactured from fiberglass to
the dimensions shown on the plans.
D. Filter Drainage Aggregate: Coarse Aggregate comprised of natural stones meeting the requirements of Section 901
with a size distribution of any of the listed aggregate gradations from size No. 57 through size No. 89 inclusive, except
as noted on the Plans.
E. Wall Draintile: Perforated or slotted PVC or corrugated HDPE pipe manufactured in accordance with ASTM D3034
and/or ASTM F405. The pipe may be covered with a geotextile filter fabric to function as a filter.
F. Separation Geotextile: Type D2, D3 or D5.
G. Leveling Pad: A leveling pad of unreinforced concrete shall be placed to facilitate first course placement. Concrete
leveling pads shall have a minimum thickness of 6 inches (150mm) and a minimum width of 24 inches (600mm) and
shall have a minimum 28 day compressive strength of 3,000 psi (20.7 Mpa).
DIAMOND PRO PIN SYSTEM
FLORIDA D.O.T. (SAMPLE DRAWINGS)
OLDCASTLE COASTAL TAMPA, FL
05/30/17
GENERAL NOTES
& SPECIFICATIONS
SHEET 1
W1 12
Sheet of
PROPOSED SEGMENTAL RETAINING WALLS (SRW)
Project No:
Date:
Drawn By:
Reviewed By:REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY):
This item has been electronically signed and
sealed by Jon Huyck, PE on May 30, 2017 using a
Digital Signature.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
® &
™
A
NC
HO
R W
AL
L S
YS
TE
MS
, IN
C
5959 BAKER ROAD, SUITE 390
MINNETONKA, MN 55345-5996
PHONE: (952) 933-8855
ANCHOR WALL ENGINEERING, LLC
DESIGN ENGINEER: JON C. HUYCK
FLORIDA REGISTRATION: 61043
CERT. OF AUTHORIZATION: 27077
WW
W.A
NC
HO
RW
AL
L.C
OM
Scale:
0 1
VERIFY THAT THE BAR ABOVE IS 1". IF NOT,
ADJUST THE SCALE ACCORDINGLY.
NOT TO SCALE
3.02 WALL ERECTION
A. Foundation units shall be placed on the prepared leveling pad. Units shall be checked for horizontal alignment with a
string line placed at the back of the units and vertical alignment front to back and side to side with a level. The top of all
units in the base course shall be at the same elevation.
B. Ensure that concrete wall units are in full contact with base. Up to 1/2 inch of sand may be placed between the concrete
leveling pad and and foundation unit to help level the base unit.
C. The foundation course of modular units shall be backfilled and compacted, front and back, then checked for level and
alignment prior to placing the next course of wall units.
D. Wall subdrain shall be installed at the lowest elevation possible to maintain gravity flow of water to outside of the
reinforced zone. The wall subdrain shall be day-lighted to an appropriate location away from the wall system at each low
point and at 50-foot (15 m) intervals along the wall.
E. Remove all excess fill from top of units and from the pin holes. Install pins in either front or rear pin holes, depending on
design wall batter and install next course.
F. Subsequent courses of modular units shall be placed side by side for full length of wall alignment. A maximum gap of 1/8
inch (3.2 mm) is allowed between units. Alignment should be checked by using a string line at the back of the units.
Adjust units as necessary to maintain horizontal alignment.
G. Provide a minimum of 12 inches (300 mm) of angular permeable material (see Section 548) placed behind the modular
units. Place a filter fabric separator between the permeable aggregate and the backfill soil.
H. Ensure permeable material and backfill are compacted before installation of each succeeding course. The permeable
material (Filter Drainage Aggregate) placed behind the block shall be compacted with a minimum of 2 passes using a
vibratory plate compactor.
I. Install each succeeding course. Backfill as each course is completed and prior to placement of the next course. Pull the
units forward until the locating surface of the unit contacts the locating surface of the units in the preceding course.
J. Check unit vertical alignment with a level on each course, adjust units as necessary with reinforcement shims to maintain
proper alignment and setback control.
K. Permeable material or reinforced soil fill must be placed level with the top of the modular units at courses where
reinforcement is required.
L. Remove all excess fill from top of units and from the pin holes in the top of the units prior to reinforcement placement.
M. Install geosynthetic reinforcement at locations and elevations shown on the design drawings.
1. The geosynthetic reinforcement has a primary strength direction. The primary strength direction must be placed
perpendicular to the wall face.
2. Reinforcement panels shall be continuous. Seams or connections are not permitted in the strength direction. 100
percent reinforcement coverage is required.
3. Panels of geosynthetic reinforcement shall be tensioned such that all folds and wrinkles are removed before
reinforced soil is placed. Panels shall be staked or anchored as necessary to maintain taut condition.
4. Tracked vehicles may not operate on geosynthetic reinforcement with less than 6 inches of compacted soil between
the reinforcement and the tracks. Turning of tracked vehicles should be kept to a minimum to prevent damage and
disturbance to the reinforcement.
5. Rubber-tired vehicles may operate directly on geosynthetic reinforcement at speeds less than 10 mph if permitted
by the reinforcement manufacturer. Sudden braking and turning shall be avoided.
3.03 BACKFILL PLACEMENT
A. Special care shall be taken during compaction below the first reinforcement layer to maintain unit level and alignment.
B. At each level of soil reinforcement the backfill material shall be roughly level to an elevation approximately 1” (30mm) above the level
of the facing unit before placing the soil reinforcement.
C. Clean any debris off the top of the units and from the pin holes in the top of the units and ensure the backfill is graded reasonably flat
prior to reinforcement placement.
D. The reinforcement has a primary strength direction, which must be laid perpendicular to the wall face.
E. Prior to placement of backfill and after placement of the pins, pull the reinforcement taut and anchor in place with stakes, staples or fill
piles at the back of the reinforcement.
F. Place the reinforced backfill onto the reinforcement and spread in a direction parallel to the wall face. Reinforced backfill shall be
placed, spread and compacted in a manner that will minimize slack or wrinkles from forming in the reinforcement.
G. Place a minimum of 6” (150mm) of backfill prior to operating equipment above the reinforcement. Avoid sudden braking or turning on
fill placed over the reinforcement.
3.04 CAP UNIT INSTALLATION (Where required)
A. Brush clean the top of the upper course of units. Place cap units, cutting as necessary on curved wall portions, prior to adhering the
cap units.
B. Exterior grade construction adhesive is the preferred material to adhere the cap units to the upper course of modular units.
C. Apply an exterior concrete construction adhesive to the top surface of the upper course of units, and place the cap unit into desired
position. If mortar is used, place mortar into the pin holes in the top course of units as well as on the upper surfaces.
D. Use a string line to maintain proper cap alignment.
E. Backfill and compact to finish grade, after mortar or adhesive has set.
3.05 ADJUSTING AND CLEANING
A. Damaged units should be replaced with new units during construction.
B. Contractor shall remove debris caused by construction and leave adjacent areas clean.
3.06 QUALITY CONTROL
A. The wall installation contractor is responsible for the proper installation of all materials. A qualified independent third party shall be
enlisted to verify the correct installation of all materials according to these specifications and the construction drawings.
B. Work found to be deficient according to these specifications or the construction drawings must be corrected.
C. The retaining wall will not be considered complete until accepted by the engineer or duly appointed owner's representative.
D. Refer to Section 548: FDOT Specifications For Retaining Wall Systems.
General Note: Oldcastle Coastal will be supplying the retaining wall blocks and pins for use with other accessory materials to be used in
the construction of walls detailed herein. The Diamond Pro Pin System being provided for this project will have a split texture for the
facing. Construction and quality control procedures provided by Anchor Wall Systems and its licensees are intended to provide a general
explanation of the system. It is the contractor's obligation to unload and store the products delivered to the site, devise and execute a
project specific erection sequence, and implement a fall protection system where required. Construction and installation processes and
procedures provided by Anchor Wall Systems and its licensees are general in nature and do not account for project specific criteria.
Compliance with the guidelines in such documents does not relieve the contractor of its responsibility to adhere to the project plans,
specifications and contract documents or compliance with all fall protection, safety laws, standards, and procedures at the jobsite.
END OF SECTION
DIAMOND PRO PIN SYSTEM
FLORIDA D.O.T. (SAMPLE DRAWINGS)
OLDCASTLE COASTAL TAMPA, FL
05/30/17
GENERAL NOTES
& SPECIFICATIONS
SHEET 2
W2 12
R0.050"
59°
2.073"
R1.992"
R0.110"R0.025"
0.594"
0.178"
1.900"
R0.050"
DIAMOND PRO
®
PS
X
WX
LOCKBAR DETAIL (PRECAST CORNER)
(NOT TO SCALE)
INSIDE CURVE
WALL FACE
TOP
OUTSIDE CURVE
1. ALWAYS START CAPPING WALL FROM THE LOWEST
ELEVATION.
2. LAYOUT CAPS PRIOR TO USING ADHESIVE.
3. CUT CAPS TO FIT. VARIOUS COMBINATIONS OF LONG AND
SHORT CAP FACES WILL BE NECESSARY FOR RADII
GREATER THAN THE MINIMUM.
4. ALTERNATE SHORT AND LONG CAP FACES EVERY OTHER
CAP TO ACHIEVE A STRAIGHT ROW OF CAPS.
5. USE EXTERIOR-GRADE CONSTRUCTION ADHESIVE TO
SECURE CAPS.
SAW CUT AS
REQUIRED TO
CONSTRUCT
90 DEGREE
MITERED
CORNER
SPLIT FACE
AND END
11"
17 1/4"
10"
4"
11" MIN.
EXTEND GEOSYNTHETIC
REINFORCEMENT TO
WITHIN 1" OF THE
LOWER BLOCK FACE
8"
12"
8"
FRONT VIEW
SIDE VIEW
TOP VIEW
18"
12"
16"
9"
12 1/2"
6"
8"
1.7° PIN CORE
7.1° PIN CORE
PIN ALIGNING CORES
FIBERGLASS PIN
5"
R0.25"
CAP UNIT ISOMETRIC VIEW
18"
90-DEGREE CORNER UNIT
DIAMOND PRO
®
PS
X
WX
INDIVIDUAL UNIT DETAILS
(NOT TO SCALE)
DIAMOND PRO
®
PS
X
WX
CAPPING DETAILS
(NOT TO SCALE)
DIAMOND PRO
®
PS
X
WX
REINFORCEMENT CONNECTION DETAIL
(NOT TO SCALE)
DIAMOND PRO PIN SYSTEM UNIT
11"
MINIMUM
PRECAST CORNER UNIT
30"
7.5"
15"
7.5"
R0.050"
59°
2.073"
R1.992" R0.110"R0.025"
0.594"0.178"
1.900"
R0.050"
DIAMOND PRO
®
PS
X
WX
LOCKBAR DETAIL (PRECAST CORNER)
(NOT TO SCALE)
Sheet of
PROPOSED SEGMENTAL RETAINING WALLS (SRW)
Project No:
Date:
Drawn By:
Reviewed By:REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY):
This item has been electronically signed and
sealed by Jon Huyck, PE on May 30, 2017 using a
Digital Signature.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
® &
™
A
NC
HO
R W
AL
L S
YS
TE
MS
, IN
C
5959 BAKER ROAD, SUITE 390
MINNETONKA, MN 55345-5996
PHONE: (952) 933-8855
ANCHOR WALL ENGINEERING, LLC
DESIGN ENGINEER: JON C. HUYCK
FLORIDA REGISTRATION: 61043
CERT. OF AUTHORIZATION: 27077
WW
W.A
NC
HO
RW
AL
L.C
OM
Scale:
0 1
VERIFY THAT THE BAR ABOVE IS 1". IF NOT,
ADJUST THE SCALE ACCORDINGLY.
AS SHOWN
DIAMOND PRO PIN SYSTEM
FLORIDA D.O.T. (SAMPLE DRAWINGS)
OLDCASTLE COASTAL TAMPA, FL
05/30/17
TYPICAL
BLOCK/CONSTRUCTION
DETAILS
W3 12
MIN 1.7°
MAX 7.1°
12" (MIN) OF FREE-
DRAINING AGGREGATE
2'-0"
6"
FINISHED
GRADE
H
E
CAP UNIT
DIAMOND PRO
® PS UNIT (TYP)
H = EXPOSED WALL HEIGHT (VARIES)
E = EMBEDMENT DEPTH (6" MINIMUM)
ADJUST BLOCKS AS NEEDED TO
MAINTAIN RUNNING BOND
FINISHED GRADE
H
E
CAP BLOCK
DIAMOND PRO
®
PS
BLOCK
4"Ø MIN WALL SUBDRAIN
(ELEVATION VARIES)
7.1° BATTER:
1.7° BATTER:
PLACE PINS IN REAR
SET OF PIN CORES
BACK OF PIN ALIGNING
CORE TO FULLY ABUT PIN
PLACE PINS IN FRONT
SET OF PIN CORES
1"
1"
BACK OF PIN ALIGNING
CORE TO FULLY ABUT PIN
DIAMOND PRO
®
PS
X
WX
TYPICAL REINFORCED CROSS SECTION W/ CAP
(NOT TO SCALE)
DIAMOND PRO
®
PS
X
WX
TYPICAL ELEVATION VIEW
(NOT TO SCALE)
DIAMOND PRO
®
PS
X
WX
PIN INSTALLATION DETAIL
(NOT TO SCALE)
8" MIN. UNREINFORCED
CONCRETE OR COMPACTED
AGGREGATE LEVELING PAD
GEOSYNTHETIC
REINFORCEMENT (TYP)
8" MIN. UNREINFORCED
CONCRETE OR COMPACTED
GRANULAR BASE LEVELING PAD
SEPARATION GEOTEXTILE (TYP)
SEPARATION GEOTEXTILE
(AGGREGATE LEVELING PAD ONLY)
Sheet of
PROPOSED SEGMENTAL RETAINING WALLS (SRW)
Project No:
Date:
Drawn By:
Reviewed By:REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY):
This item has been electronically signed and
sealed by Jon Huyck, PE on May 30, 2017 using a
Digital Signature.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
® &
™
A
NC
HO
R W
AL
L S
YS
TE
MS
, IN
C
5959 BAKER ROAD, SUITE 390
MINNETONKA, MN 55345-5996
PHONE: (952) 933-8855
ANCHOR WALL ENGINEERING, LLC
DESIGN ENGINEER: JON C. HUYCK
FLORIDA REGISTRATION: 61043
CERT. OF AUTHORIZATION: 27077
WW
W.A
NC
HO
RW
AL
L.C
OM
Scale:
0 1
VERIFY THAT THE BAR ABOVE IS 1". IF NOT,
ADJUST THE SCALE ACCORDINGLY.
AS SHOWN
DIAMOND PRO PIN SYSTEM
FLORIDA D.O.T. (SAMPLE DRAWINGS)
OLDCASTLE COASTAL TAMPA, FL
05/30/17
TYPICAL
CONSTRUCTION
DETAILS
W4 12
2'-0"
6"
MIN 1.7°
MAX 7.1°
Wos
1
11
1
De
Wos = WIDTH OF OVERSIZING
De = DEPTH OF EXCAVATION
L = LENGTH OF GEOSYNTHETIC REINFORCEMENT
Wos = (2 * De) + L + 6"
REINFORCEMENT LENGTH (L)
FINISHED
GRADE
6" MIN. UNREINFORCED CONCRETE
OR 8" MIN. COMPACTED
AGGREGATE BASE LEVELING PAD
12 INCHES OF FREE
DRAINING AGGREGATE
2ND COURSE BELOW GRADE
2ND COURSE ABOVE GRADE
1ST COURSE BELOW GRADE
1ST COURSE ABOVE GRADE
SPACING VARIES
50' MAXIMUM
2" CUT
DAYLIGHT DRAIN
THRU WALL FACE
REMOVE PORTION OF
ADJACENT UNITS TO ALLOW
WALL SUBDRAIN THRU FACE
4" TEE
4" Ø PERFORATED WALL
SUBDRAIN (EL VARIES,
SLOPE 1% MIN.)
N
A
T
IV
E
S
O
IL
2'-0"
6
" M
IN
. U
N
R
E
IN
F
O
R
C
E
D
C
O
N
C
R
E
T
E
O
R
8
" M
IN
.
C
O
M
P
A
C
T
E
D
A
G
G
R
E
G
A
T
E
B
A
S
E
L
E
V
E
L
IN
G
P
A
D
A
P
P
R
O
X
I
M
A
T
E
L
I
M
I
T
S
O
F
E
X
C
A
V
A
T
I
O
N
L
E
V
E
L
I
N
G
P
A
D
T
R
E
N
C
H
FINISHED
GRADE
6" MIN. UNREINFORCED
CONCRETE OR 8" MIN.
COMPACTED AGGREGATE
BASE LEVELING PAD
NATIVE
SOIL
DIAMOND PRO
®
PS
BLOCK
DIAMOND PRO
®
PS
X
WX
TYPICAL BASE PREPARATION
(NOT TO SCALE)
DIAMOND PRO
®
PS
X
WX
TYPICAL STEP-UP DETAIL
(NOT TO SCALE)
DIAMOND PRO
®
PS
X
WX
TYPICAL EXCAVATION OVERSIZING CROSS SECTION
(NOT TO SCALE)
DIAMOND PRO
®
PS
X
WX
OUTLET DRAIN TILE DETAIL
(NOT TO SCALE)
SEPARATION GEOTEXTILE (TYP)
Sheet of
PROPOSED SEGMENTAL RETAINING WALLS (SRW)
Project No:
Date:
Drawn By:
Reviewed By:REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY):
This item has been electronically signed and
sealed by Jon Huyck, PE on May 30, 2017 using a
Digital Signature.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
® &
™
A
NC
HO
R W
AL
L S
YS
TE
MS
, IN
C
5959 BAKER ROAD, SUITE 390
MINNETONKA, MN 55345-5996
PHONE: (952) 933-8855
ANCHOR WALL ENGINEERING, LLC
DESIGN ENGINEER: JON C. HUYCK
FLORIDA REGISTRATION: 61043
CERT. OF AUTHORIZATION: 27077
WW
W.A
NC
HO
RW
AL
L.C
OM
Scale:
0 1
VERIFY THAT THE BAR ABOVE IS 1". IF NOT,
ADJUST THE SCALE ACCORDINGLY.
AS SHOWN
DIAMOND PRO PIN SYSTEM
FLORIDA D.O.T. (SAMPLE DRAWINGS)
OLDCASTLE COASTAL TAMPA, FL
05/30/17
TYPICAL
CONSTRUCTION
DETAILS
W5 12
DIAMOND PRO
®
PS
X
WX
OUTSIDE ANGLES DETAIL
(NOT TO SCALE)
INSIDE ANGLES 90°-110°
PLACE GEOGRID REINFORCEMENT
SUCH THAT ITS ALIGNMENT IS
PERPENDICULAR TO FACE OF WALL
AND THAT 100% COVERAGE OF
REINFORCED FILL IS PROVIDED.
CORNER UNIT - CUT TO
CREATE DESIRED ANGLE
NOTES:
1. ALTERNATE COURSES "A" & "B" AS NEEDED TO FULL
HEIGHT OF WALL.
2. MODIFY UNITS AS NEEDED TO MAINTAIN RUNNING BOND.
3. ADHERE ALL PARTIAL UNITS AND CORNER UNITS WITH
CONSTRUCTION GRADE ADHESIVE.
4. ADJUST PLACEMENT IN FIELD TO ACHIEVE DESIRED ANGLE
5. FREE-DRAINING AGGREGATE (NOT SHOWN) TO SPAN 10 FT.
ALONG THE WALL FACE AND TO THE BACK OF THE
REINFORCED ZONE FOR INSIDE ANGLES LESS THAN 90°.
INSIDE ANGLES 70°-110°
COURSE A
PRECAST CORNER UNIT -
CAST UNIT TO ATTAIN
DESIRED ANGLE
TRIM GEOGRID AT BACK OF
RETURN WALL BLOCK UNITS
PANEL 1
COURSE B
PANEL 1
PANEL 2
TRIM GEOGRID AT
BACK OF RETURN
WALL BLOCK UNITS
TRIM DIAMOND PRO
UNITS AS NECESSARY
TO MAINTAIN
RUNNING BOND
CORNER UNIT GEOGRID
(TYP, PLACED AT 15"
VERTICAL SPACING)
COURSE A
CORNER UNIT -
CUT TO CREATE
DESIRED ANGLE
TRIM UNIT AS
NECESSARY
CORNER UNIT -
CUT TO CREATE
DESIRED ANGLE
TRIM UNIT AS
NECESSARY
COURSE B
TRIM GEOGRID AT BACK OF
RETURN WALL BLOCK UNITS
TRIM GEOGRID AT
BACK OF RETURN
WALL BLOCK UNITS
PANEL 1
PANEL 1
PANEL 2
PANEL 1
PANEL 2
3" (MIN) OF SOIL FILL REQUIRED
BETWEEN OVERLAPPED
REINFORCEMENT FOR PROPER
SOIL AND REINFORCEMENT
INTERACTION (TYP)
H/4
INSIDE ANGLES 70° - 90°
H/4
INSIDE ANGLES 70°-110°
INSIDE ANGLES 70° - 90°
DRAINAGE AGGREGATE PLACEMENT
ENSURE THAT GRID
OVERLAP DOES NOT OCCUR
BETWEEN BLOCK UNITS
Sheet of
PROPOSED SEGMENTAL RETAINING WALLS (SRW)
Project No:
Date:
Drawn By:
Reviewed By:REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY):
This item has been electronically signed and
sealed by Jon Huyck, PE on May 30, 2017 using a
Digital Signature.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
® &
™
A
NC
HO
R W
AL
L S
YS
TE
MS
, IN
C
5959 BAKER ROAD, SUITE 390
MINNETONKA, MN 55345-5996
PHONE: (952) 933-8855
ANCHOR WALL ENGINEERING, LLC
DESIGN ENGINEER: JON C. HUYCK
FLORIDA REGISTRATION: 61043
CERT. OF AUTHORIZATION: 27077
WW
W.A
NC
HO
RW
AL
L.C
OM
Scale:
0 1
VERIFY THAT THE BAR ABOVE IS 1". IF NOT,
ADJUST THE SCALE ACCORDINGLY.
AS SHOWN
DIAMOND PRO PIN SYSTEM
FLORIDA D.O.T. (SAMPLE DRAWINGS)
OLDCASTLE COASTAL TAMPA, FL
05/30/17
TYPICAL
CONSTRUCTION
DETAILS
W6 12
X
X
X
X
SECOND
COURSE
FIRST
COURSE
THIRD
COURSE
FOURTH
COURSE
NOTE: USE ADHESIVE ON EXPOSED PARTIAL UNITS.
CUT UNITS (X) TO MAINTAIN RUNNING BOND
L
L
NOTE:
IN THE "CROSS-OVER AREA" OF REINFORCEMENT,
ONE OF THE LAYERS OF REINFORCEMENT SHOULD
BE LOWERED OR RAISED ONE COURSE TO ALLOW
PLACEMENT OF THE REINFORCEMENT WITH THE
PRINCIPLE REINFORCEMENT STRENGTH DIRECTION
PROPERLY ORIENTATED. THE REINFORCEMENT
SHOULD NOT EXTEND INTO THE SEGMENTAL
RETAINING WALL UNITS ON THE RETURN LEG OF
THE 90-DEGREE CORNER.
PRINCIPLE
REINFORCEMENT
DIRECTION
PR
IN
CIP
LE
RE
IN
FO
RC
EM
EN
T
DIR
EC
TIO
N
NOTES:
1. ALTERNATE COURSES "A" & "B" AS NEEDED TO FULL HEIGHT OF WALL.
2. MODIFY UNITS AS NEEDED TO MAINTAIN RUNNING BOND.
3. ADHERE ALL PARTIAL UNITS AND CORNER UNITS WITH CONSTRUCTION GRADE
ADHESIVE.
4. ADJUST PLACEMENT IN FIELD TO ACHIEVE DESIRED ANGLE
5. FREE-DRAINING AGGREGATE (NOT SHOWN) TO SPAN 10 FT. ALONG THE WALL FACE
AND TO THE BACK OF THE REINFORCED ZONE FOR INSIDE ANGLES LESS THAN 90°.
DIAMOND PRO
®
PS
X
WX
90-DEGREE OUTSIDE CORNER
(NOT TO SCALE)
DIAMOND PRO
®
PS
X
WX
90-DEGREE OUTSIDE CORNER W/ GRID
(NOT TO SCALE)
DIAMOND PRO
®
CORNER UNIT
COURSE A
COURSE B
TRIM GEOGRID AT BACK OF
RETURN WALL BLOCK UNITS
PRECAST CORNER UNIT -
CAST UNIT AT ATTAIN
90-DEGREE CORNER
PANEL 1
PANEL 2
PANEL 1
TRIM GEOGRID AT BACK OF
RETURN WALL BLOCK UNITS
DIAMOND PRO
®
PS
X
WX
90-DEGREE OUTSIDE CORNER W/ PRECAST CORNER UNIT
(NOT TO SCALE)
CORNER UNIT GEOGRID
(TYP, PLACED AT 15"
VERTICAL SPACING)
Sheet of
PROPOSED SEGMENTAL RETAINING WALLS (SRW)
Project No:
Date:
Drawn By:
Reviewed By:REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY):
This item has been electronically signed and
sealed by Jon Huyck, PE on May 30, 2017 using a
Digital Signature.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
® &
™
A
NC
HO
R W
AL
L S
YS
TE
MS
, IN
C
5959 BAKER ROAD, SUITE 390
MINNETONKA, MN 55345-5996
PHONE: (952) 933-8855
ANCHOR WALL ENGINEERING, LLC
DESIGN ENGINEER: JON C. HUYCK
FLORIDA REGISTRATION: 61043
CERT. OF AUTHORIZATION: 27077
WW
W.A
NC
HO
RW
AL
L.C
OM
Scale:
0 1
VERIFY THAT THE BAR ABOVE IS 1". IF NOT,
ADJUST THE SCALE ACCORDINGLY.
AS SHOWN
DIAMOND PRO PIN SYSTEM
FLORIDA D.O.T. (SAMPLE DRAWINGS)
OLDCASTLE COASTAL TAMPA, FL
05/30/17
TYPICAL
CONSTRUCTION
DETAILS
W7 12
X
X X
X
NOTE: USE ADHESIVE ON EXPOSED PARTIAL UNITS
CUT UNITS (X) TO MAINTAIN RUNNING BOND
SECOND
COURSE
FIRST
COURSE
THIRD
COURSE
FOURTH
COURSE
H/4
H/4 EXTENSION
BEYOND BACK
OF BLOCK
REINFORCEMENT H/4 BEYOND
THE CORNER AT THE SPECIFIED
REINFORCEMENT ELEVATIONS
DIAMOND PRO
®
PS
X
WX
INSIDE CORNER
(NOT TO SCALE)
DIAMOND PRO
®
PS
X
WX
INSIDE ANGLES DETAIL
(NOT TO SCALE)
DIAMOND PRO
®
PS
X
WX
INSIDE CORNER W/ GRID
(NOT TO SCALE)
PR
IN
CIP
LE
RE
IN
FO
RC
EM
EN
T
DIR
EC
TIO
N
PLACE ADDITIONAL REINFORCEMENT
ON THE NEXT COURSE OF SEGMENTAL
UNITS IMMEDIATELY ABOVE THE
SPECIFIED PLACEMENT ELEVATION IN A
MANNER THAT ELIMINATES GAPS LEFT
BY THE PREVIOUS LAYER OF
GEOSYNTHETIC AT THE SPECIFIED
REINFORCEMENT ELEVATION. (TYP)
GAP < 3 FT
OPTION A: GAPS BETWEEN GRID < 3 FT
TRIM OVERLAPPED PANELS AT
BACK OF BLOCK FACE TO REDUCE
OVERLAP. WHERE AREAS OF
OVERLAP OCCUR, PLACE AT LEAST
3 INCHES OF REINFORCED FILL
BETWEEN GRID LAYERS.
GAP > 3 FT
OPTION B: GAPS BETWEEN GRID > 3 FT
PLACE ADDITIONAL REINFORCEMENT ON
THE SAME COURSE OF SEGMENTAL UNITS.
ADDITIONAL REINFORCEMENT LAYERS TO
TERMINATE AT BACK OF BLOCK.
TRIM OVERLAPPED PANELS AT
BACK OF BLOCK FACE TO REDUCE
OVERLAP. WHERE AREAS OF
OVERLAP OCCUR, PLACE AT LEAST
3 INCHES OF REINFORCED FILL
BETWEEN GRID LAYERS.
Sheet of
PROPOSED SEGMENTAL RETAINING WALLS (SRW)
Project No:
Date:
Drawn By:
Reviewed By:REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY):
This item has been electronically signed and
sealed by Jon Huyck, PE on May 30, 2017 using a
Digital Signature.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
® &
™
A
NC
HO
R W
AL
L S
YS
TE
MS
, IN
C
5959 BAKER ROAD, SUITE 390
MINNETONKA, MN 55345-5996
PHONE: (952) 933-8855
ANCHOR WALL ENGINEERING, LLC
DESIGN ENGINEER: JON C. HUYCK
FLORIDA REGISTRATION: 61043
CERT. OF AUTHORIZATION: 27077
WW
W.A
NC
HO
RW
AL
L.C
OM
Scale:
0 1
VERIFY THAT THE BAR ABOVE IS 1". IF NOT,
ADJUST THE SCALE ACCORDINGLY.
AS SHOWN
DIAMOND PRO PIN SYSTEM
FLORIDA D.O.T. (SAMPLE DRAWINGS)
OLDCASTLE COASTAL TAMPA, FL
05/30/17
TYPICAL
CONSTRUCTION
DETAILS
W8 12
L
L
L
L
3" (MIN) OF SOIL FILL REQUIRED
BETWEEN OVERLAPPED
REINFORCEMENT FOR PROPER
SOIL AND REINFORCEMENT
INTERACTION (TYP)
PLACE ADDITIONAL REINFORCEMENT ON
THE NEXT COURSE OF SEGMENTAL UNITS
IMMEDIATELY ABOVE THE SPECIFIED
PLACEMENT ELEVATION IN A MANNER THAT
ELIMINATES GAPS LEFT BY THE PREVIOUS
LAYER OF GEOSYNTHETIC AT THE SPECIFIED
REINFORCEMENT ELEVATION. (TYP)
INSIDE CURVE NOTES:
1. DRAINAGE AGGREGATE NOT
SHOWN FOR CLARITY
2. MINIMUM RADIUS: 6 FT. TO FACE
NOTES:
1. PLACE REINFORCEMENT SO LITTLE OR NO OVERLAP OCCURS IN
THE RADIUS AREA. IF OVERLAP OCCURS, PLACE 3 INCHES (MIN)
OF SAND BETWEEN THE REINFORCEMENT LAYERS
2. DRAINAGE AGGREGATE NOT SHOWN FOR CLARITY
3. MINIMUM RADIUS: 4 FT. TO FACE
DIAMOND PRO
®
PS
X
WX
OUTSIDE CURVE DETAIL
(NOT TO SCALE)
DIAMOND PRO
®
PS
X
WX
INSIDE CURVES DETAIL
(NOT TO SCALE)
OPTION A: GAPS BETWEEN GRID < 3 FT
L
PLACE ADDITIONAL REINFORCEMENT ON
THE SAME COURSE OF SEGMENTAL UNITS.
ADDITIONAL REINFORCEMENT LAYERS TO
TERMINATE AT BACK OF BLOCK
PR
IN
CIP
LE
RE
IN
FO
RC
EM
EN
T
DIR
EC
TIO
N
TRIM GRID SO NO OVERLAP
OCCURS BETWEEN
ADJACENT GRID LAYERS
TO AVOID POINT LOADING
PRINCIPLE
REINFORCEMENT
DIRECTION
PR
IN
CIP
LE
RE
IN
FO
RC
EM
EN
T
DIR
EC
TIO
N
OPTION B: GAPS BETWEEN GRID > 3 FT
GAP < 3 FT
GAP > 3 FT
3" (MIN) OF SOIL FILL REQUIRED
BETWEEN OVERLAPPED
REINFORCEMENT FOR PROPER SOIL AND
REINFORCEMENT INTERACTION (TYP)
USE TEMPORARY MARKERS ON THE
FACING BLOCKS TO ENSURE PLACEMENT
OF REINFORCEMENT AT INTERMEDIATE
LAYERS COINCIDES WITH THE GAPS. (TYP)
Sheet of
PROPOSED SEGMENTAL RETAINING WALLS (SRW)
Project No:
Date:
Drawn By:
Reviewed By:REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY):
This item has been electronically signed and
sealed by Jon Huyck, PE on May 30, 2017 using a
Digital Signature.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
® &
™
A
NC
HO
R W
AL
L S
YS
TE
MS
, IN
C
5959 BAKER ROAD, SUITE 390
MINNETONKA, MN 55345-5996
PHONE: (952) 933-8855
ANCHOR WALL ENGINEERING, LLC
DESIGN ENGINEER: JON C. HUYCK
FLORIDA REGISTRATION: 61043
CERT. OF AUTHORIZATION: 27077
WW
W.A
NC
HO
RW
AL
L.C
OM
Scale:
0 1
VERIFY THAT THE BAR ABOVE IS 1". IF NOT,
ADJUST THE SCALE ACCORDINGLY.
AS SHOWN
DIAMOND PRO PIN SYSTEM
FLORIDA D.O.T. (SAMPLE DRAWINGS)
OLDCASTLE COASTAL TAMPA, FL
05/30/17
TYPICAL
CONSTRUCTION
DETAILS
W9 12
MIN 1.7°
MAX 7.1°
3.3 FT. MIN.
5 FT. MIN.
GUIDE RAIL (DESIGNED BY OTHERS)
CAP BLOCK
SLEEVE AND NON-SHRINK
GROUT AROUND POST/PIPE
SLEEVE INSTALLED DURING
WALL CONSTRUCTION
ADD SUPPLEMENTAL LAYERS
OF GEOGRID AT LOCATIONS
SHOWN ON ELEVATIONS
(WIDTH MAY VARY)
CAREFULLY CUT
GEOGRID AROUND
STRUCTURE
VERTICAL OBSTRUCTION
(DESIGNED BY OTHERS)
ADD SUPPLEMENTAL LAYERS
OF GEOGRID ON EITHER SIDE
OF STRUCTURE AT LOCATIONS
SHOWN ON ELEVATIONS
CAREFULLY CUT GEOGRID
AROUND STRUCTURE (TYP)
VERTICAL
OBSTRUCTION
PLAN VIEW
SECTION VIEW
X D X
2(X) + D
GEOGRID LENGTH PER
WALL PROFILE SHEETS
CUT SLIT IN GEOGRID TO ALLOW
TO LAY DOWN BEHIND STRUCTURE
3' MIN
12 INCHES OF FREE
DRAINING AGGREGATE
DIAMOND PRO
®
PS
BLOCK
DIAMOND PRO
®
PS
BLOCK
DIAMOND PRO
®
PS
X
WX
TYPICAL DETAILS FOR DROP STRUCTURE BEHIND WALL
(NOT TO SCALE)
TOP COURSE OF
DIAMOND PRO
®
PS BLOCK
MIN 1.7°
MAX 7.1°
DIAMOND PRO
®
PS
X
WX
TYPICAL GUIDE RAIL DETAIL
(NOT TO SCALE)
SLEEVE AND NON-SHRINK
GROUT AROUND POST/PIPE
SLEEVE INSTALLED DURING
WALL CONSTRUCTION
GEOSYNTHETIC
REINFORCEMENT (TYP)
SEPARATION GEOTEXTILE (TYP)
Sheet of
PROPOSED SEGMENTAL RETAINING WALLS (SRW)
Project No:
Date:
Drawn By:
Reviewed By:REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY):
This item has been electronically signed and
sealed by Jon Huyck, PE on May 30, 2017 using a
Digital Signature.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
® &
™
A
NC
HO
R W
AL
L S
YS
TE
MS
, IN
C
5959 BAKER ROAD, SUITE 390
MINNETONKA, MN 55345-5996
PHONE: (952) 933-8855
ANCHOR WALL ENGINEERING, LLC
DESIGN ENGINEER: JON C. HUYCK
FLORIDA REGISTRATION: 61043
CERT. OF AUTHORIZATION: 27077
WW
W.A
NC
HO
RW
AL
L.C
OM
Scale:
0 1
VERIFY THAT THE BAR ABOVE IS 1". IF NOT,
ADJUST THE SCALE ACCORDINGLY.
AS SHOWN
DIAMOND PRO PIN SYSTEM
FLORIDA D.O.T. (SAMPLE DRAWINGS)
OLDCASTLE COASTAL TAMPA, FL
05/30/17
TYPICAL
CONSTRUCTION
DETAILS
W10 12
MIN 1.7°
MAX 7.1°12 INCHES OF FREE
DRAINING AGGREGATE
SECOND COURSE
CAP BLOCK
2'-0"
6"
WATER
ELEVATION
VARIES
EROSION
PROTECTION
(DESIGNED BY
OTHERS)
BACKFILL WITH FREE DRAINING
AGGREGATE TO 1 FT. ABOVE
HIGH WATER ELEVATION
4" Ø WALL SUBDRAIN (EL. VARIES)
GEOSYNTHETIC REINFORCEMENT
DIAMOND PRO
®
PS
BLOCK
DIAMOND PRO
®
PS
X
WX
WALL ABUTTING STRUCTURE
(NOT TO SCALE)
EXISTING STRUCTURE
FIRST COURSE
EXISTING STRUCTURE
CONSTRUCTION JOINT
CUT UNIT TO
CREATE JOINT (TYP)
DIAMOND PRO
®
PS
X
WX
CONSTRUCTION JOINT DETAIL
(NOT TO SCALE)
DIAMOND PRO
®
PS
BLOCK
DIAMOND PRO
®
PS
X
WX
TYPICAL SHORELINE CROSS SECTION
(NOT TO SCALE)
6" MIN. UNREINFORCED
CONCRETE OR 8" MIN.
COMPACTED AGGREGATE
BASE LEVELING PAD
SEPARATION GEOTEXTILE (TYP)
SEPARATION
GEOTEXTILE (TYP)
SEPARATION GEOTEXTILE
BEHIND TWO BLOCKS,
EXTENDING BACK 2 FT NEXT
TO THE EXISTING STRUCTURE
SEPARATION GEOTEXTILE
BEHIND TWO BLOCKS,
EXTENDING BACK 2 FT NEXT
TO THE EXISTING STRUCTURE
NOTE: IMPLEMENT CONSTRUCTION
JOINTS IN WALL WHEN TOTAL
SETTLEMENTS GREATER THAN 4"
AND/OR DIFFERENTIAL SETTLEMENTS
GREATER THAN 0.5% ARE EXPECTED.
Sheet of
PROPOSED SEGMENTAL RETAINING WALLS (SRW)
Project No:
Date:
Drawn By:
Reviewed By:REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY):
This item has been electronically signed and
sealed by Jon Huyck, PE on May 30, 2017 using a
Digital Signature.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
® &
™
A
NC
HO
R W
AL
L S
YS
TE
MS
, IN
C
5959 BAKER ROAD, SUITE 390
MINNETONKA, MN 55345-5996
PHONE: (952) 933-8855
ANCHOR WALL ENGINEERING, LLC
DESIGN ENGINEER: JON C. HUYCK
FLORIDA REGISTRATION: 61043
CERT. OF AUTHORIZATION: 27077
WW
W.A
NC
HO
RW
AL
L.C
OM
Scale:
0 1
VERIFY THAT THE BAR ABOVE IS 1". IF NOT,
ADJUST THE SCALE ACCORDINGLY.
AS SHOWN
DIAMOND PRO PIN SYSTEM
FLORIDA D.O.T. (SAMPLE DRAWINGS)
OLDCASTLE COASTAL TAMPA, FL
05/30/17
TYPICAL
CONSTRUCTION
DETAILS
W11 12
NOTE: BARRIER SHOWN IS CONCEPTUAL ONLY. DESIGN OF THE
BARRIER AND REINFORCING STEEL IS THE RESPONSIBILITY OF
THE PROJECT STRUCTURAL ENGINEER. REFER TO FDOT
STANDARD INDEX FOR CONSTRUCTION DETAILS.
DIAMOND PRO
®
PS
BLOCK
1.7°
DIAMOND PRO
®
PS
X
WX
TYPICAL CONCRETE MOMENT SLAB & BARRIER
(NOT TO SCALE)
ENLARGED DETAIL A
∟ 2" X 2" X 1/8" GALVANIZED ANGLE
END ABUTMENT
EXTEND GEOGRID BACK 2'
INTO REINFORCED ZONE
TAPCON ANCHOR BOLT (SIZE
& SPACING PER DESIGN)
DIAMOND PRO
®
PS
BLOCK
2'-0"
6"
6" MIN. UNREINFORCED
CONCRETE OR 8" MIN.
COMPACTED AGGREGATE
BASE LEVELING PAD
FINISHED
GRADE
C.I.P. BUILDUP
CONCRETE
(BY OTHERS)
PRECAST COPING - REFER
TO FDOT MSE WALL COPING
(PRECAST OR C.I.P.) INDEX
(BY OTHERS)
CONCRETE SLOPE PAVEMENT (TYP)
SEE FDOT CONTRACT DOCUMENTS
FOR CONSTRUCTION INFO (BY OTHERS)
TRIM GEOGRID AROUND
BRIDGE PILES (TYP)
GRID CONNECTION TO END
ABUTMENT (SEE DETAIL A)
2'-0"
SEPARATION GEOTEXTILE (TYP)
GEOSYNTHETIC
REINFORCEMENT (TYP)
DIAMOND PRO
®
PS
X
WX
TYPICAL SECTION AT BRIDGE ABUTMENT
(NOT TO SCALE)
12 INCHES OF FREE
DRAINING AGGREGATE
DEFLECT TOP LAYER OF
GEOGRID DOWN AS
NECESSARY TO AVOID COPING
12 INCHES OF FREE
DRAINING AGGREGATE
2 LAYERS 30 LB
ROOFING FELT
SHOULDER OR
ROADWAY PAVEMENT
C.I.P. BARRIER WITH PRECAST COPING
AND C.I.P. JUNCTION SLAB (REFER TO
FDOT WALL COPING WITH TRAFFIC
RAILING/JUNCTION SLAB INDEX)
SEPARATION GEOTEXTILE (TYP)
GEOSYNTHETIC
REINFORCEMENT (TYP)
BUILD-UP CONCRETE
BETWEEN DIAMOND
PRO BLOCK AND
BOTTOM OF COPING
GEOSYNTHETIC REINFORCEMENT (TYP)
GEOSYNTHETIC
REINFORCEMENT
1.7°
Sheet of
PROPOSED SEGMENTAL RETAINING WALLS (SRW)
Project No:
Date:
Drawn By:
Reviewed By:REVISION DATES (SEE SHEET W1 FOR REVISION HISTORY):
This item has been electronically signed and
sealed by Jon Huyck, PE on May 30, 2017 using a
Digital Signature.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
® &
™
A
NC
HO
R W
AL
L S
YS
TE
MS
, IN
C
5959 BAKER ROAD, SUITE 390
MINNETONKA, MN 55345-5996
PHONE: (952) 933-8855
ANCHOR WALL ENGINEERING, LLC
DESIGN ENGINEER: JON C. HUYCK
FLORIDA REGISTRATION: 61043
CERT. OF AUTHORIZATION: 27077
WW
W.A
NC
HO
RW
AL
L.C
OM
Scale:
0 1
VERIFY THAT THE BAR ABOVE IS 1". IF NOT,
ADJUST THE SCALE ACCORDINGLY.
AS SHOWN
DIAMOND PRO PIN SYSTEM
FLORIDA D.O.T. (SAMPLE DRAWINGS)
OLDCASTLE COASTAL TAMPA, FL
05/30/17
TYPICAL
CROSS
SECTIONS
W12 12