Download - CURVA EVMU-3-6

Transcript
Page 1: CURVA EVMU-3-6

Pump Performance DatasheetCustomer :Customer reference :Item number : DefaultService :Quantity : 1

Quote number :Size : EVMU3-6Stages : 6Based on curve number : EVMU3-6Date last saved : 03 Apr 2014 10:45 AM

Operating ConditionsFlow, rated : 0.80 l/sDifferential head / pressure, rated (requested) : 55.00 mDifferential head / pressure, rated (actual) : 60.92 mSuction pressure, rated / max : 0.00 / 0.00 psi.gNPSH available, rated : AmpleFrequency : 60 Hz

PerformanceSpeed, rated : 3,450 rpmImpeller diameter, rated : 3.50 inImpeller diameter, maximum : 3.50 inImpeller diameter, minimum : 3.50 inEfficiency : 51.97 %NPSH required / margin required : 2.49 / 0.00 ftNs (imp. eye flow) / Nss (imp. eye flow) : 1,083 / 5,735 US UnitsMCSF : 0.21 l/sHead, maximum, rated diameter : 80.38 mHead rise to shutoff : 31.94 %Flow, best eff. point (BEP) : 0.99 l/sFlow ratio (rated / BEP) : 81.20 %Diameter ratio (rated / max) : 100.00 %Head ratio (rated dia / max dia) : 100.00 %Cq/Ch/Ce/Cn [ANSI/HI 9.6.7-2010] : 1.00 / 1.00 / 1.00 / 1.00Selection status : Acceptable

LiquidLiquid type : WaterAdditional liquid description :Solids diameter, max : 0.00 inSolids concentration, by volume : 0.00 %Temperature, max : 68.00 deg FFluid density, rated / max : 1.000 / 1.000 SGViscosity, rated : 1.00 cPVapor pressure, rated : 0.00 psi.a

MaterialMaterial selected : Stainless Steel

Pressure DataMaximum working pressure : 114.2 psi.gMaximum allowable working pressure : 232.0 psi.gMaximum allowable suction pressure : N/AHydrostatic test pressure : N/A

Driver & Power DataDriver sizing specification : Rated powerMargin over specification : 0.00 %Service factor : 1.00Power, hydraulic : 0.64 hpPower, rated : 1.23 hpPower, maximum, rated diameter : 1.33 hpMinimum recommended motor rating : 1.50 hp / 1.12 kW (Fixed)

Ebara Quotation System 14.0.1.2014032813