HFC 1
Trunk, distribution network, equaliser and house
Controlled and uncontrolled amplifiers for:- trunk networks- distribution networks- active equalisation- house connection
Compact Amplifiers
HFCHFC 32
Overview 4
VGX distribution network amplifier 6
VGX2143D-1G2 6
VGX 242D-1G2 8
Controlled trunk / distribution network amplifiers 12
VGP3243D-1G2 12
VGP2143D-1G2 14
Uncontrolled equaliser amplifiers 16
VGE 1285-1G2 / VGE 12258-1G2 16
House connection amplifiers 18
VOS 952-1G / VOS 953-1G 18
Accessories 20
Overview of accessoiries for the VGX distribution network amplifiers 20
Overview of accessoiries for controlled trunk / distribution
network amplifiers 21
Overview of plug-in diplex filter sets and accessoires for
house connection amplifiers 22
WiFi adapters, transponders 24
Tap/splitter plug-in cards 25
Zero cards, equalisers 26
Connectors, plug-in diplex filters 28
Technical data 29
Order number overview 41
HFC Network Architectures
Our Company
The BKtel Group has its origin in the
foundation of BKtel communications in
1997. The group was extended in 2002
with BKtel systems (merged with BKtel
communications in 2009), BKtel
components (2006), BKtel Photonics
(2014) and BKtel networks in 2017.
Further international offices were founded
in China and Japan for the growing Asian
market. The entire group has currently a
workforce of over 130 employees
worldwide, based in Germany in Hueckel-
hoven, (near Düsseldorf), in Rosenheim
(near Munich) and in Kornwestheim (near
Stuttgart).
The company develops and manufactures
products in the field of interactive FTTH-,
Video Overlay-, RFoG- and HFC-networks
for high performance data, telephone
and cable TV services. The high quality
products as well as the comprehensive
support in designing optical networks
make BKtel to one of the leading suppliers
in the FTTH and HFC market.
Our Products
BKtel develops equipment and software
for FTTH and HFC broadband networks.
The product portfolio includes a wide
range of products starting from equipment
for optical transmission such as optical
transmitters, amplifiers, and receivers and
customer premises equipment, CATV
headends, coaxial cable amplifiers. BKtel
manufacturing facilities guarantee a high
quality standard (ISO 9001 certified).
Furthermore the company offers a
complete range of services such as
planning, installation and training.
HFCHFC 54
Modern compact amplifiers with monitoring capability for interactive HFC networks
Innovative operating concept: Electronic actuators, set up via Wi-Fi module and handheld
device (settings can be saved in the Web browser and on PC/handheld device)
Built-in (VGPxxxx) or optional (VGX xxx), frequency-agile 2-pilot control speeds up
commissioning:
• Automatic levelling on the forward path saves time-consuming manual calibration
• Return path can be pre-adjusted automatically
Remote configuration of all tuning parameters supported by the monitoring system
(can be activated/deactivated)
High gain (up to 46 dB uncontrolled), configurable interstage
Very high output level with lowest intermodulation products even with interstage attenuation
De-emphasis (inverse equalisation) insert position
Remote feed capability at each input/output, local feed: 10 A
Insert position for monitoring transponder
Test sockets at input/output and in the return path amplifier
Plug-in diplexers
Built-in return path amplifier, adjustable gain
Ingress control switch
Die cast aluminium housing
General properties of compact amplifiers
Additional properties for all VGPxxxD-1G2
Frequency range 1006/1218 MHz switchable
The latest GaN technology (Second Generation)
Power supply unit with power factor correction
Additional properties VGP3243D-1G2
Two active outputs with configuration of up to 3 high levels
distribution outputs or one trunk output and up to two
distribution outputs (via internal output splitter field)
Gain and slope of the distribution network output can be set
separately
Additional properties VGXxxxxD-1G2
Frequency range 1006 / 1218 MHz pluggable
The latest GaN technology (Second Generation)
Power supply unit with power factor correction
High gain (up to 46 dB uncontrolled)
Loop-through output (VGX2143-1G2 only)
Equaliser amplifier VGE 12xxx-1G2
Fixed gain and slope
Passive return path with 65 / 204 MHz
Compact housing for easy retrofitting on the network
The compact amplifiers with electronic set-up
BKtel is delivering a compact amplifier class of the very latest
generation with its VGP product range, combining comprehen-
sive setting options, electronic operation and outstanding
technical data with an unrivalled price-performance ratio.
"Plug-and-Play" redefined
Electronic set-up of all significant parameters, automatic levelling
and option of remote configuration via HMS or DOCSIS moni-
toring minimise commissioning and maintenance times. Thanks
to the copy function supported by the WTE 10, all settings can be
saved and transferred to other devices. As well as speeding up
commissioning on site, not having to use plug-in cards for
attenuation and slope simplifies logistics and reduces storage
costs.
Commissioning of uncontrolled amplifiers
without a meter – it couldn't be easier
The setting is made with the Wi-Fi adapter or an handheld
device. The Wi-Fi adapter provides a convenient means of
configuring the connected amplifier via a PC, tablet or smart-
phone (a Web browser with active support for JavaScript is
required). Thanks to automatic levelling, it takes only a few steps
to put the compact amplifiers into operation:
Simply enter the required output level for the upper and lower
pilot frequency and start the levelling process.
The device automatically sets itself to the required values in just
a few seconds. The technical data is adjusted to the optimum
settings. After this, manual fine adjustment is possible at any
time.
Next, automatic pre-adjustment can be started on the return
path too.
Levelling takes even less time to complete on subsequent
devices. The copy function transfers the desired settings directly.
Overview Compact Amplifiers
HFCHFC 76
Modern compact amplifier for DOCSIS 3.1 HFC networks
Frequency range: up to 1218 MHz
High gain (up to 46 dB)
Loop-through output, configurable via the input splitter
field "Loop-Through"
Two distribution outputs, configurable via the output
splitter field
End stage in the latest GaN technology
Innovative operating concept: Electronic actuators,
setting via a WTE 10 WiFi module
Optional ALSC module with frequency-agile 2-pilot
control speeds up commissioning
• Automatic levelling on the forward path saves time-
consuming manual calibration
• Return path can be pre-adjusted automatically
Very high output level with lowest intermodulation
products even with interstage attenuation
Insert positions in the forward and return path
Remote feed capability: 10 A at each input/output
Insert position for TVM 500S FSK transponder
Test sockets at the input/output and in the return path
amplifier
Built-in return path amplifier, adjustable electronically
Ingress control switch (ICS)
Die-cast aluminium housing with 5/8" connections
NOTE
For an overview of accessories, see page 20-28.
Block diagram
VGX2143D-1G2
Features
The VGX2143D-1G2 is a distribution network amplifier
designed for current and future DOCSIS 3.1 HFC networks.
The amplifier features up to two outputs and an additional
loop-through output. All electronic settings of the amplifier
can be configured using the WTE 10 Wi-Fi module together with
a Web browser. The return path bandwidth is determined by the
plug-in diplex filter sets.
VGX distribution network amplifier
VGX distribution network amplifier
During operation, an EBC/EAC xx must be plugged into
the insert position at the output. Zero cards are already
plugged into the insert positions No. 2, 3, 4.
“Hingepoint” insert position
Plug-in input diplex filter
Connection socket for the handheld / WiFi module Insert position for FSK multi-band transponder module
“Forward 1” insert position
“Forward 2” insert position
F test socket internal (-20 dB) input
“Return 1” and “Return 2” insert position
Insert position for 2-pilot control module
Plug-in output diplex filter
Standard version: Modules for the following insert positions are not included in the product package:
F test socket internal (-20 dB) output
1
1
2
2
3
3
4
4
5
5
6
6
9
9
7
7
8
8
11
11
10
10
Plug-in low-pass filter
Plug-in high-pass filter
Splitter field output
12
13
14
13
12
14
15 Splitter field input "Loop-Through"
15
HFCHFC 98
Modern compact amplifier for DOCSIS 3.1 HFC networks
Frequency range: up to 1218 MHz
High gain (up to 42 dB)
Two distribution outputs, configurable via the output
splitter field
End stage in the latest GaN technology
Innovative operating concept: Electronic actuators,
setting via a WiFi module
Optional ALSC module with frequency-agile 2-pilot
control speeds up commissioning
• Automatic levelling on the forward path saves time-
consuming manual calibration
• Return path can be pre-adjusted automatically
Very high output level with lowest intermodulation
products even with interstage attenuation
JXP insert positions in the forward and return path
Remote feed capability: 7 A at each input/output,
Insert position for TVM 500S FSK transponder
Test sockets at the input/output and in the return path
amplifier
Built-in return path amplifier, adjustable electronically
Ingress control switch (ICS)
Die-cast aluminium housing with 5/8" connections
NOTE
For an overview of accessories, see page 20-28
Block diagram
VGX 242D-1G2
Features
The VGX 242D-1G2 is a distribution network amplifier
designed for current and future DOCSIS 3.1 HFC net-
works. The amplifier features up to two outputs. All elec-
tronic settings of the amplifier can be configured using the
WTE 10 Wi-Fi module together with a Web browser. The return
path bandwidth is determined by the plug-in diplex filter sets.
VGX_242.pdf 1 09.05.2017 12:00:49
“Hingepoint” insert position
Plug-in input diplex filter
Connection socket for the WTE 10 Wi-Fi adapter Insert position for FSK multi-band transponder module
“Forward 1” and JXP insert position
“Forward 2” insert position
F test socket internal (-20 dB) input
“Return 1” and JXP insert position
Insert position for 2-pilot control module
Plug-in output diplex filter
Standard version: Modules for the following insert positions are not included in the product package:
F test socket internal (-20 dB) output Plug-in low-pass filter
Plug-in high-pass filter
Splitter field output
VGX distribution network amplifier
VGX distribution network amplifier
During operation, an EBC/EAC xx must be plugged into
the insert position at the output. Zero cards are already
plugged into the insert positions No. 2, 3, 4.
1
2
3
4
5
6
9
7
8
1110
12
13
14
1
2
3
4
5
6
7
9
8
11
10
12
13
14
HFCHFC 1110
Additional properties of the VGXxxxxD-1G2 amplifiers in detail
State-of-the-art switched-mode power supply unit technology with very long
service life
Active power factor correction with a factor of almost 1
Improved dissipation of waste heat from the entire power supply unit thanks to
the heatsink coating. This results in a lower heat load in the device itself and
also helps to increase the maximum operating temperature range
The power supply unit is easy to replace in the event of maintenance:
• Easily accessible plug-in contacts and screw connections
• No thermal pad required. This removes the need for positioning the pad and
eliminates the risk of losing it
High mutual shielding between forward path, return path and other
functional areas in the device. This prevents cross modulation and other
unwanted coupling effects
Improved temperature discharge thanks to the built-in thermal dissipation
domes on the bottom and top of the components. This results in a lower
heat load in the surrounding components and also helps to increase the
maximum operating temperature range
Function can be adjusted to suit requirements in a modular way
Power supply unit
Single-chamber shielding system
New modularity
Familiar modularity
Insert position for 2-pilot control module. This enables cost-effective use of
the device for controlled and uncontrolled operation
FSK transponder insert position for TVM 500S for controlling the ICS switch
and for carrying out base unit updates remotely
Customer-specific insert positions in the forward and return path enable
additional manual signal adjustment for built-in electronic set-up
Insert position for operation in different frequency ranges (1.2 GHz/1 GHz)
(Hingepoint for 1.2 GHz pre-mounted)
Customer-specific interstage forward insert position for plug-in cards such as
system equalisers
Plug-in diplexers for adjusting the frequency split of forward and return path
Output insert field, individually configurable for one to two outputs with
EBC/EAC xx-1G2 splitter or tap plug-in cards
Splitter field input (VGX2143D-1G2 only) for individual loop-through
output configuration using EBC/EACxx-1G2 splitter and respectively tap
plug-in cards
Revolutionary
concept
VGX distribution network amplifier
1
2
3
1
2
3
HFCHFC 1312
Ingress test point external
Plug-in input diplex filter
Connection socket for handheld / Wi-Fi adapter Insert position for monitoring transponder module
“Forward 1” insert position
“Forward 2” insert position
F test socket internal (-20 dB) input
Plug in low pass filter “TP Return Path”
Plug-in output diplex filter
Plug-in high pass filter “HP Forward Path”
Splitter field output (splitters, taps)F test socket internal (-20 dB) output
Modern controlled amplifier with remote monitoring for
DOCSIS 3.1 HFC networks
Frequency range: up to 1218 MHz
(selectable between 1006 MHz and 1218 MHz)
Configuration of up to 3 high level distribution or 1 trunk
level and up to 2 distribution network outputs
GaN second generation 2 active outputs amplifier
Innovative operating concept: Electronic actuators setting
by Wi-Fi module (minimizing plug in cards and attenua-
tion pads. Exactly readable and reproducible settings)
Built in frequency agile 2 pilot control speeds up com-
missioning:
• Automatic levelling on the forward path saves time
consuming manual setting
• Return path can be adjusted automatically
Remote configuration of all tuning parameters supported
by monitoring system (can be deactivated)
Very high output level (115 dBµV) with very low inter-
modulation products even with interstage attenuation
Remote feed capability: Up to 10 A at each input/
output, local feed: 10 A
Insert position for monitoring transpoder
(FSK/HMS/DOCSIS)
Test sockets at the input/output and in the return path
amplifier
Built in return path amplifier, adjustable electronically
Ingress control switches (ICS)
Die cast aluminum housing with PG 11 connections
Features
The VGP3243D-1G2 is a dual mode trunk / distribution net-
work amplifier designed for current and future DOCSIS 3.1 HFC
networks. Two active output stages can be configured for up to 3
high level distribution network or 1 trunk level and up to 2 distri-
bution network outputs. The output level of the amplifier are 2
pilot controlled. All amplifier settings are made electronically using
the handheld or Wi-Fi module with a Web browser.
For an overview of accessories, see page 20-28.
Block diagram
VGP3243D-1G2
Controlled dual mode trunk / distribution amplifier
NOTE
Standard version: Modules for the following insert positions are not
included in the product package:
Controlled trunk / distribution network amplifiers
During operation, an EBC/EAC xx must be plugged into
the output splitter field. Pass through cards are already
plugged into the insert positions no. 2 and 3. The optional
HMS monitoring transponder TVM 850 can only be used
up to a maximum return path frequency of 65 MHz.
1
2
3
4
5
6
7
9
8
11
10
12
1
2
3
456
7
9
8
11
1012
9
VGP 3243-1G2
dBHPPlug In
Position
HP
LP
dB
HP
LP
LP
Docsis/HMS/FSK Transponder
Switched Mode Power Supply ALSC 2 Pilot / AGC / Controller
AC
OUT 1
OUT 2
OUT 3
TP OUT 1
TP OUT 2Plug In Position dB
ICSdB
ICSdB
dBdBPlug In
Position
HP
LP
TP IN
IN
IngressTest
HFCHFC 1514
Modern controlled amplifier with remote monitoring for
DOCSIS 3.1 HFC networks
Frequency range: up to 1218 MHz (selectable between
1006 MHz and 1218 MHz)
Configuration of up to 1 distribution network outputs
High gain: up to 43 dB controlled
GaN second generation 1 active output amplifier
Innovative operating concept: Electronic actuators setting
by Wi-Fi module (minimizing plug in cards and attenua-
tion pads. Exactly readable and reproducible settings)
Built in frequency agile 2 pilot control speeds up
commissioning:
• Automatic levelling on the forward path saves time
consuming manual setting
• Return path can be adjusted automatically
Remote configuration of all tuning parameters supported
by monitoring system (can be deactivated)
Very high output level (115 dBµV) with very low inter-
modulation products even with interstage attenuation
Remote feed capability: Up to 10A at each input/output,
local feed: 10 A
Insert position for monitoring transpoder
(FSK/HMS/DOCSIS)
Test sockets at the input/output and in the return path
amplifier
Built in return path amplifier, adjustable electronically
Ingress control switches (ICS)
Die cast aluminum housing with PG 11 connections
NOTE
During operation, an EBC/EAC xx must be plugged into
the output splitter field. Pass through cards are already
plugged into the insert positions no. 2 and 3. The optional
HMS monitoring transponder TVM 850 can only be used
up to a maximum return path frequency of 65 MHz.
Ingress test point external
Plug-in input diplex filter
Connection socket for the WTE 10 Wi-Fi adapter Insert position for monitoring transponder module
“Forward 1” insert position
“Forward 2” insert position
F test socket internal (-20 dB) input
Plug in low pass filter “TP Return Path”
Plug-in output diplex filter
Plug-in high pass filter “HP Forward Path”
F test socket internal (-20 dB) output
For an overview of accessories, see page 20-28.
The VGP 2143D-1G2 is a distribution network amplifier
designed for current and future DOCSIS 3.1 HFC networks.
One active output stage can be configured for up to 2 high
level distribution network outputs.
All amplifier settings are made electronically using the handheld
or Wi-Fi module with a Web browser. The return path bandwidth
is determined by various plug in diplex filter sets.
Splitter field output (splitters, taps)
Block diagram
VGP2143D-1G2
Features
Standard version: Modules for the following insert positions are not
included in the product package:
Controlled trunk / distribution network amplifiers
1
2
3
4
5
6
7
9
8
11
10
12
1
2
3
456
7
9
8
11
1012
HFCHFC 1716
Features VGE 1285-1G2
· Forward path frequency range: 85-1218 MHz
· Forward path gain of 12 dB/10 dB pre-emphasis
· Return path frequency range: 5-65 MHz
Features VGE 12258-1G2
· Forward path frequency range: 258-1218 MHz
· Forward path gain of 12,5 dB/ 11 dB pre-emphasis
· Return path frequency range: 5-204 MHzActual product not shown
The VGE equaliser amplifier is ideal for supplementary compen-
sation of cable attenuation in the case of a network upgrade.
The forward range starts at 85 MHz or 258 MHz respectively and
goes up to 1218 MHz. A slope of 10 dB or 11 dB respectively on
the upstream cable network resulting from long cable lengths is
compensated. As the amplifier requires no manual set-up,
it offers an plug-and-play solution that is easy to install. The
return path, which goes from 5 to 65 MHz or 5 to 204 MHz
respectively, is passive with a low attenuation of max. 2.5 dB.
Power can be supplied to the amplifier by connecting a remote
feed to the input or output. The input or output can also be used
to supply looped-through remote feed currents up to 7 A to the
upstream or downstream amplifiers.
VGE 1285-1G2 block diagram
¹) Providing a suitable plug is used
For an overview of accessories, see page 20-28.
VGE 1285-1G2 / VGE 12258-1G2
Uncontrolled equaliser amplifiers
Common features
Low return loss of 2.5 dB
Input and output can be fed remotely
High screening factor - class A
High corrosion resistance
Protection class: IP 65 ¹)
Simple installation
Connections: 5/8"-24 (socket)
Optional mounting plate ZMP 200
for wall mounting
HFCHFC 1918
House connection amplifiers
Input insert position e.g. for de-emphasis equaliserLED (power supply function)
Forward path: attenuation and equalisation are
set with slide switches
Return path can be switched between passive/active
Built-in return path amplifier can be adjusted with
slide switches
Insert position for the monitoring transponder
F test socket for the return path (-10 dB)
Two-way F test socket at the input (-20 dB)
F test socket at the output for return path
measurement or feed (-20 dB)
Monitorable house connection amplifiers for modern
HFC networks
The latest GaAs-MMIC technology
Innovative operating concept:
• Set-up via slide switches
• Exactly reproducible device settings
• Fewer plug-in cards and attenuation pads required
Very high output level with very low intermodulation
products
Built-in active and passive return path with numerous
setting options
1-band operation available, requires no return path
15 MHz high-pass filter can be activated on the return
path
Ingress control switch (ICS)
HMS or DOCSIS monitorable (option)
Insert position for additional functions on the forward
path (e.g. de-emphasis)
Two-way test socket at the amplifier input with inductive
decoupling
Directional coupler test socket at the amplifier output
and on the return path
Feature for injecting test signals for the return path
Highly efficient switched mode power supply unit
VOS 952-1G - local feed, F sockets
VOS 953-1G - remote feed (for auto-supply), F sockets
Voltage surge conductors on all RF connections and in
the switched mode power supply unit
Die-cast housing
Test sockets: F sockets
The compact and very reasonably priced VOS 952-1G and VOS
953-1G house connection amplifiers have been designed for use
in modern HFC networks. Features of its design worthy of
particular note include the high dynamic range during interstage
operation and a money-saving operating concept with slide
switches.
Block diagram
For an overview of accessories, see page 20-28.
VOS 952-1G / VOS 953-1G
Features
Standard version: Modules for the following insert positions are not included in
the product package:
3
83
CurrentTemperature
two-way internal
Pre-emphasis Pre-emphasis
Pre-emphasis
Pre-emphasis
AttenuationAttenuation
Attenuation Attenuation
De-emphasis
Operating voltage
Return path Return path
passive
active
passive
active
Monitoring transponder
Return path Return path
Input
= slide switch
switched off
F connectorF connector F connector F connector
"switched off"
Ingress detection
Output
(Return path:
Return path two-way
House connection amplifiers
12
3
4
5
6
7
9
8
1
2
3
4
5
6
7
9
8
2
HFCHFC 2120
Overview of accessories for controlled trunk / distribution network amplifiersOverview of accessories for the VGX distribution network amplifiers
Description Type Order no. VGP xxxxD-1G2
Zero card for operation with one output 1.2 GHz EBC 00-1G2 24510217
Splitter (two symmetrical outputs) 1.2 GHz EBC 90-1G2 24510214
Tap (3/6 dB) 1.2 GHz EAC 93-1G2 24510216
Tap (1.5/10 dB) 1.2 GHz EAC 90-1G2 24510215
Tap (0.8/20 dB) 1.2 GHz EAC 94-1G2 24510220
FSK multi-band transponder module TVM 500 26210846
FSK multi-band transponder module, small TVM 500S 26210868 -
DOCSIS monitoring transponder TVM 1000 26210086
WiFi module for wireless via a Webbrowser WTE 10 25010086
Adapter ring PG 11 to 5/8" EMU 29 273243
Adapter PG 11 to 3.5/12 socket EMP 53 25010011
PG 11 to IEC connector (f) with M14 male thread EMP 34 275289
PG 11 to F-socket (female) EMP 35 275300
Plug-in diplex filter sets
Diplexer 65/85 MHz WFS 906-1G2 24510218
Forward path equaliser 85 MHz ERS 9085-1G2 24510219
Return path equaliser 65 MHz ERR 9065 24510156
Diplexer 85/105 MHz WFS 908-1G2 24510222
Forward path equaliser 105 MHz ERS 9105-1G2 24510223
Return path equaliser 85 MHz ERR 9085 24510158
Diplexer 204/258 MHz WFS 920-1G2 24510209
Forward path equaliser 258 MHz ERS 9258-1G2 24510210
Description Type Order no. VGX xxxxD-1G2
Zero card for operation with one output 1.2 GHz EBC 00-1G2 24510217
Splitter (two symmetrical outputs) 1.2 GHz EBC 90-1G2 24510214
Tap (3/6 dB) 1.2 GHz EAC 93-1G2 24510216
Tap (1.5/10 dB) 1.2 GHz EAC 90-1G2 24510215
Tap (0.8/20 dB) 1.2 GHz EAC 94-1G2 24510220
FSK multi-band transponder module TVM 500 26210846 -
FSK multi-band transponder module, small TVM 500S 26210868
DOCSIS monitoring transponder TVM 1000 26210086 -
WiFi module for wireless setting via a Webbrowser WTE 10 25010086
Automativ level and slope control module ALSCM 10 24510232
PG 11 to 3.5/12 connector (female) EMP 53 25010011 -
PG 11 to IEC connector (female) with M14 male thread EMP 34 275289 -
5 / 8" to F connector (female) EMP 51 275351
Plug-in diplex filter sets
Diplexer 65/85 MHz WFS 906-1G2 24510218
Forward path equaliser 85 MHz ERS 9085-1G2 24510219
Return path equaliser 65 MHz ERR 9065 24510156
Diplexer 85/105 MHz WFS 908-1G2 24510222
Forward path equaliser 105 MHz ERS 9105-1G2 24510223
Return path equaliser 85 MHz ERR 9085 24510158
Diplexer 204/258 MHz WFS 920-1G2 24510209
Forward path equaliser 258 MHz ERS 9258-1G2 24510210
Accessories
Accessories
See additional data on the next page
HFCHFC 2322
Description Type Order no. VOS 952-1G VOS 953-1G
De-emphasis equaliser, switchable, 862 MHz
ERD 810 24510110
De-emphasis cable equivalent 7 dB, 862 MHz
ERZ 940 24510059
De-emphasis cable equivalent 7 dB, based on 85-862 MHz, 1 GHz
ERD 813 24510117
Attenuation pad 6 dB, 1 GHz ERD 814 24510120
Attenuation pad 10 dB, 1 GHz ERD 815 24510127
Adapter ring PG 11 to 5/8" EMU 29 273243 - -
Adapter PG 11 to 3.5/12 socket EMP 53 25010011 - -
PG 11 to IEC connector (f) with M14 male thread
EMP 34 275289 - -
PG 11 to F-socket (female) EMP 35 275300 - -
Plug-in diplexer sets
Diplexer 65/85 MHz WFS 906-1G2 24510218 - -
Forward path equaliser 85 MHz ERS 9085-1G2 24510219 - -
Return path equaliser 65 MHz ERR 9065 24510156 - -
Diplexer 85/105 MHz WFS 908-1G2 24510222 - -
Forward path equaliser 105 MHz ERS 9105-1G2 24510223 - -
Return path equaliser 85 MHz ERR 9085 24510158 - -
Diplexer 204/258 MHz WFS 920-1G2 24510209 - -
Forward path equaliser 258 MHz ERS 9258-1G2 24510210 - -
Return path equaliser 204 MHz ERR 9204 24510211 - -
Description Type Order no. VOS 952-1G VOS 953-1G
Splitter (two symmetrical outputs) EBC 90-1G 24510113 - -
Tap (3/6 dB) EAC 93-1G 24510115 - -
Tap (1.5/10 dB) EAC 90-1G 24510116 - -
Tap (0.8/20 dB) EAC 94-1G 24510114 - -
Tap 2/6 dB, 3 dB de-emphasis ERP 101 24510128 - -
FSK multi-band transponder module TVM 500 26210846 - -
FSK multi-band transponder module, small
TVM 500S 26210868- -
DOCSIS monitoring transponder TVM 1000 26210086
Equaliser 47-630 MHz, can be adjusted from 2-18 dB in 2 dB steps
ERZ 630 24510108
System equaliser 862 MHz ERS 800 24510109
Overview of accessories for house connection amplifiers
Overview of plug-in diplex filter sets
Return / Forward Frequency Type Order no. VGXxxxxD-1G2 VGP2143D-1G2 VGP3243D-1G2
65 / 85 MHz WFS 906-1G2 24510218 2 2 3
ERS 9085-1G2 24510219 1 1 1
ERR 9065 24510156 1 1 1
85 / 105 MHz WFS 908-1G2 24510222 2 2 3
ERS 9105-1G2 24510223 1 1 1
ERR 9085 24510158 1 1 1
204 / 258 MHz WFS 920-1G2 24510209 2 2 3
ERS 9258-1G2 24510210 1 1 1
ERR 9204 24510211 1 1 1
The table shows the number of plug in modules for full configuration of each amplifier type.
Accessories
HFCHFC 2524
WiFi moduleWTE 10
The WTE 10 WiFi moduleallows connected amplifiers and fibre nodes to be accessed
conveniently from a PC, tablet or smartphone for configuration purposes. To view the
configuration, only a Web browser supporting JavaScript is required. The WTE 10 Wi-Fi
module simply has to be connected to the controlling device (plug-and-play connection);
it draws its power supply from the controlling device.
Features
WiFi standard to IEEE 802.11 b/g/n
Display of all device settings via a Web interface
Ambient conditions:
• Operating temperature: -20 to +50°C
• Suitable for outdoor use
• Housing protection class: IP 54
Language: English
Copy function for saving the device settings
No additional power supply necessary
Can be updated in order to support new devices and functions
FSK multi-band transponder moduleTVM 500/TVM 500 S
FSK transponder for compact and house connection amplifiers and also optical
compact receivers (see page 44)
Control of the ingress control switch in devices that are equipped with this facility
Robust Frequency Shift Keying (FSK) modulation
Frequency-agile in selected frequency ranges
DOCSIS/Euro-DOCSIS 2.0 monitoring transponder, frequency-agileTVM 1000 Monitoring transponder for amplifiers and optical compact receivers (see table on
page 44)
Monitoring of various parameters such as voltage, current consumption, internal
temperature, etc.
Transmission in DOCSIS or EuroDOCSIS protocol
10/100 BaseT service interface
Frequency-agile in the range 5-65/90-862 MHz
Additional monitoring functions
Tap/splitter plug-in cards EAC 90-1G2, EAC 93-1G2, EAC 94-1G2, EBC 90-1G2
Plug-in modules to expand the corresponding device to two outputs
Can be used in the splitter field loop-through input
Suitable for amplifiers and fibre nodes
Tap/splitter plug-in cards EAC 90-1G, EAC 93-1G, EAC 94-1G, EBC 90-1G
Plug-in modules to expand the corresponding device to two outputs
Can also be used in the splitter field loop-through input depending on device type
Suitable for amplifiers and legacy 1 GHz fiber nodes
Actual product not shown
Actual product not shown
Accessories
Robust Handheld HTE 20*
The HTE 20* can be connected to amplifiers and fiber nodes for configuration of these
host devices using a data cable. This new handheld is the successor of the HTE10 and
inherits the possibility to control also the devices supported by the HTE10. The HTE 20*
handheld is conveniently powered by the controlled device (plug-and-play connection).
Features
Display of all device settings on the integrated display.
Ambient conditions:
• Operating temperature: -20 to +50°C
• Suitable for outdoor use
• Housing protection class: IP 54
Language: English
Copy function for saving the device settings
No additional power supply necessary
Software can be updated in order to support new devices and functions
Very fast start up time * Available in Q1 / 2019
HFCHFC 2726
C-line pre-emphasis equaliser ERC 22
De-emphasis equaliser ERZ 940
Features
Creates a pre-emphasis based on the C-line specification for german networks
For use in the universal input insert position (“Forward 1”)
Features
Cable simulation, 7 dB
7 dB de-emphasis equaliser for VOS 95x and VGP 95x
Equaliser, 630 MHz ERZ 630
Features
Equaliser, 47-630 MHz
Adjustable from 2-18 dB in 2 dB steps (cable equivalent)
For use in the input insert position of the VOS 95x and other amplifiers
System equaliser ERS 800
Features
System equaliser for use in special application cases
Characteristic: Cable-equivalent pre-emphasis in range 47-700 MHz:
3 dB (equivalent in range 47-862 MHz: 4 dB)
Cable-equivalent pre-emphasis in range 700-862 MHz:
3 dB (equivalent to increase of 2 dB in range 700-862 MHz)
Suitable for compact amplifiers and compact fiber nodes
Prinzipieller Frequenzverlauf ERS 800
0
1
2
3
4
5
6
7
0 100 200 300 400 500 600 700 800MHz
dB
86247
De-emphasis equaliser/attenuation attachment ERD 813, ERD 814, ERD 815, ERP 101
Equalisers and attenuation pads
Features
Available types:
• ERD 813: Cable-equivalent de-emphasis 7 dB ¹)
• ERD 814: 6 dB attenuation ¹)
• ERD 815: 10 dB attenuation ¹)
ERP 101: Tap 2/6 dB, de-emphasis 3 dB ¹)
Suitable for amplifiers and fiber nodes
¹) Based on 862 MHz
Zero cards EBC 01E-1G, EBC 00-1G2
Features
Plug-in modules for trough connection e.g. for operation with one output
Actual product not shown
Accessories
HFCHFC 2928
Plug-in diplex filtersWFS 906-1G2, ERS 9085-1G2, ERR 9065 WFS 908-1G2, ERS 9105-1G2, ERR 9085 WFS 920-1G2, ERS 9258-1G2, ERR 9204Diplex filters and return path system equalisers for bandwidth selection.
Components for frequency split 65/85 MHz:
WFS 906-1G2: Input and output diplexer 65/85 MHz
ERS 9085-1G2: Interstage downstream equaliser (downstream from 85 MHz)
ERR 9065 return path system equaliser (upstream up to 65 MHz)
Components for frequency split 85/105 MHz:
WFS 908-1G2: Input and output diplexer 85/105 MHz
ERS 9105-1G2: Interstage downstream equaliser (downstream from 105 MHz)
ERR 9085: Return path system equaliser (upstream up to 85 MHz)
Components for frequency split 204/258 MHz:
WFS 920-1G2: Input and output diplexer 204/258 MHz
ERS 9258-1G2: Interstage downstream equaliser (downstream from 258 MHz)
ERR 9204: Return path system equaliser (upstream up to 204 MHz)
Connectors as options for die cast housings EMP 34, EMP 35, EMU 29
Transitions:
EMP 34 (BN 275289): PG 11 to IEC connector (female)
EMP 35 (BN 275300): PG 11 to F connector (female)
EMP 53 (BN 25010011): PG 11 to 3.5 / 12 connector (female)
EMU 29 (BN 273243): Adapter ring PG 11 to 5/8"
EMP 51 (BN 275351): 5/8" to F connector (female)
EMP 34
EMP 35
EMU 29
Technical data
Type VGX 242D-1G2 VGX2143D-1G2 Comments
Order no. 24410188 690019-xx
Forward path
Number of outputs 1 or 2
Loop-through output No Yes
Frequency range [MHz] 85-1006/1218
Gain (at 1218 MHz) uncontrolled/controlled with ALSC module ALSCM 10 [dB]
42/37 46/43
Gain variation, uncontrolled/controlled [dB] ± 1.5/0.8
Return loss [dB] 18 -1.5 dB/oct. (min. 13)
Frequency response (85-1218 MHz at 25°C) [dB] ± 0.5
Frequency response additional [dB] ± 0.8
Attenuation range by electronical setting [dB] 0-20
Interstage attenuation range [dB] 0-20
Slope range by electronical setting [dB] 0-18
Pre-emphasis range by elecronical setting [dB] 0-18
Noise figure [dB] 7
Automatic slope control range [dB] ± 2
Automatic gain control range [dB] ± 3
Max. input level [dBµV] 85
Maximum output level BER 10^-9, 110 QAM 256, 258-1218 MHz, 10 dB slope [dBµV]
109 111
Hum modulation [dB] 70
Spurious (> 85 MHz) [dBµV] 15
Return path
Frequency range [MHz] 5-65/5-85/5-204 With WFS 9065/WFS 9085/WFS
9204
Gain [dB] 28/29/33 With WFS 9065/WFS 9085/WFS
9204
Amplitude response 5-204 MHz, at 25°C [dB] ± 0.5
See additional data on the next page
VGX distribution network amplifier
Accessories Technical data
HFCHFC 3130
Type VGX 242D-1G2 VGX2143D-1G2 Comments
Additional amplitude response over attenuation, slope and temperature [dB]
± 0.4
Input noise density (CINR = 50 dB, 25 dB gain flat) [dBµV / Hz]
-9
Dynamic range: CINR > 50 dB, 5-65 MHz, 25 dB gain [dB]
25
Attenuation range, electronically adjustable [dB] 5 – 30 / 4 – 30 / 0 - 30Depending onDiplex filter set
(65/85/204 MHz)
Slope range, electronically adjustable [dB] 0.4 – 7.5 / 0.8 – 9 / 1 - 14Depending onDiplex filter set
(65/85/204 MHz)
ICS attenuation (can be switched via EMS or WiFi module) [dB]
0/6/> 45
Hum modulation at 7A (>15 MHz) [dB] 70
Spurious (> 15 MHz) [dBµV] < 15
General
Impedance [Ω] 75
AC supply voltage including tolerances [V] 30-90
Power consumption (High/Low Mode) [W] 20/17 21/18
Max. remote feed current per connection [A] 7
RF input and output connections 5/8"
Housing protection class IP 54 (IP65 on request)
Ambient temperature range (in operation, compliant with specified data) [°C]
-20 to 60
Screening factor Class A
Over voltage protection 6 kV; 1.2/50 µs, (IEC 60-2)
Dimensions (W × H × D) [mm] 250 × 201 × 95
All data listed are typical values unless indicated otherwise.
Technical data
Type VGP3243D-1G2 Comments
Order no. 690018-xx
Forward path
Modes Trunk Distribution network
Number of trunk outputs 1 0
Number of distribution outputs 1 or 2 2 or 3
Frequency range [MHz]; upper limit selectable 85 – 1006 / 1218
Gain (at 1218 MHz) uncontrolled / controlled [dB] 40 / 37 46 / 43
Return loss [dB] 18 – 1.5 dB / oct. (min.13)
Frequency response (85 – 1218 MHz at 25°C) [dB] ± 0.5
Frequency response additional [dB] ± 0.8
Maximum input level [dBµV] 85
Maximum operation output level [dBµV] 115
CSO at 43dB gain, 10 dB slope at 1.2GHz, [dB] CENELEC 41 carriers, level at 862MHz [dBµV]
70 106
67 112
CTB at 43dB gain, 10 dB slope at 1.2GHz, [dB] CENELEC 41 carriers, level at 862MHz [dBµV]
75 106
70 112
Attenuation range, electronically adjustable [dB] 0 – 16
Slope range, electronically adjustable [dB] 1006 / 1218 MHz 0 – 13 / 15
Interstage pre-emphasis range [dB] 1006 – 1218 MHz 0 – 15 / 17
Noise figure [dB] 8
Automatic slope control range [dB] ± 2
Automatic gain control range [dB] ± 3
Frequency range of lower pilot Pu (PAL/CW/QAM) MHz 1) 120 - 450
Frequency range of upper pilot Po (PAL/CW/QAM) MHz 1) 420 - 998
Output level, BER 10^ -9, 110ch. 256QAM, 258 – 1218 MHz, 10 dB slope [dBµV]
111
Pilot carrier level range (PAL/CW/QAM) [dBµV] 83 - 112 87 - 114
Hum modulation ratio at 7 A [dB] 70
Controlled compact amplifiers
See additional data on the next page
HFCHFC 3332
Type VGP3243D-1G2 Comments
Spurious [dBµV] < 15
Return path
Frequency range [MHz] 5 – 65 / 85 / 204With WFS 906 / 908
/ 920
Gain for return path 65 / 85 / 204 MHz [dB] 28 / 29 / 33
Frequency response 8 – 204 MHz [dB] ± 0.35
Attenuation range, electronically adjustable [dB] 5 – 30 / 4 – 30 / 0 - 30Depending on Diplex filter set
(65/85/204 MHz)
Slope range, electronically adjustable [dB] 0.4 – 8 / 0.8 – 9.5 / 1 – 15Depending on Diplex filter set
(65/85/204 MHz)
Return loss 8- 65 / 85 / 204 MHz [dB] 19
ICS attenuation (can be switched via EMS or Wi-Fi module) [dB]
0 / 6 / >45
Hum modulation at 7A (>15 MHz) [dB] > 70
Test point [dB] 0
General data
Impedance [Ω] 75
Nominal supply voltage range, sine wave [VAC] 28 – 65
Power consumption without transponder [W] 42
Max. remote feed current, local injection [A] 10
Max. remote feed current, normal operation per RF port [A]
10
RF input and output interfaces 4 x PG11
Protection class acc. to DIN EN 60529 IP 54
Ambient temperature range (in operation, compliant with specified data) [°C]
-25 to +60
Over voltage protection 6kV; 1.2/50µs, (IEC 60-2)
Housing material Aluminum die cast
Dimesions (W x H x D) [mm] 2) 240 x 115 x 240
Network management (optional)
Parameters for remote management and configuration
Remote feed voltage, secondary current, supply voltage booster amplifier, temperature, electronic tuning element values, pilot settings and alarms, automatic levelling, summer / winter offset, ICS, remote inventory date, downstream frequency range, diplex filter set
¹) Setting via handheld / Wi-Fi module. Min. ratio between pilot frequency Pu and Po 250 MHz ²) Width incl. lid hinges: 267 mm All data are typical values unless indicated otherwise.
Technical data
Type VGP2143D-1G2 Comments
Order no. 690017-xx
Forward path
Number of outputs 1 or 2
Frequency range [MHz]; upper limit selectable 85 – 1006 / 1218
Gain (at 1218 MHz) uncontrolled / controlled [dB] 46 / 43
Gain variation ALSC off, -10°C … +55°C [dB] ± 1.2
Return loss [dB] 18 – 1.5 dB / oct. (min.13)
Frequency response (85 – 1218 MHz at 25°C) [dB] ± 0.5
Frequency response additional [dB] ± 0.8
Maximum input level [dBµV] 85
Maximum operating level [dBµV] 115
CSO ratio, 1 x 106 dBµV [dB] 1) 67
CTB ratio, 1 x 106 dBµV [dB] 1) 70
Attenuation range, electronically adjustable [dB] 0 – 16
Slope range, electronically adjustable [dB] 1006 / 1218 MHz 0-13 / 15
Interstage pre-emphasis range [dB] 1006 / 1218 MHz 0 – 15 / 17
Noise figure [dB] 8
Automatic slope control range [dB] ± 2
Automatic gain control range [dB] ± 3
Frequency range of lower pilot Pu (PAL/CW/QAM) MHz 2) 120 - 450
Frequency range of upper pilot Po (PAL/CW/QAM) MHz 2) 420 - 998
Output level, BER 10^ -9, 110ch. 256QAM, 258 – 1218 MHz, 10 dB slope [dBµV]
111
Pilot carrier level range (PAL/CW/QAM) [dBµV] 87 -114
Hum modulation [dB] 70
Spurious (> 85 MHz) [dBµV] < 15
See additional data on the next page
HFCHFC 3534
See additional data on the next page
Type VGP2143D-1G2 Comments
Return path
Frequency range [MHz] 5 – 65 / 85 / 204With WFS 906
/908 / 920
Gain for return path 65 / 85 / 204 MHz [dB] 28 / 29 / 33
Frequency response 8 – 204 MHz [dB] ± 0.35
Attenuation range, electronically adjustable [dB] 5 – 30 / 4 – 30 / 0 - 30Depending onDiplex filter set
(65/85/204 MHz)
Slope range, electronically adjustable [dB] 0.4 – 8 / 0.8 – 9.5 / 1 – 15Depending onDiplex filter set
(65/85/204 MHz)
Return loss 8- 65 / 85 / 204 MHz [dB] 19
ICS attenuation (can be switched via EMS or WiFi module) [dB]
0 / 6 / >45
Hum modulation at 7A (>15 MHz) [dB] > 70
Test point [dB] 0
General data
Impedance [Ω] 75
Nominal supply voltage range, sine wave [VAC] 28 – 65
Power consumption without transponder [W] 27
Max. remote feed current, local injection [A] 10
Max. remote feed current, normal operation per RF port [A]
10
RF input and output interfaces 3 x PG11
Protection class acc. to DIN EN 60529 IP 54
Ambient temperature range (in operation, compliant with specified data) [°C]
-25 to +60
Over voltage protection 6kV; 1.2/50µs, (IEC 60-2)
Housing material Aluminum die cast
Dimesions (W x H x D) [mm] 3) 240 x 95 x 240
Network management (optional)
Parameters for remote management and configuration
Remote feed voltage, secondary current, supply voltage booster amplifier, temperature, electronic tuning element values, pilot settings and alarms, automatic levelling, summer / winter offset, ICS, remote inventory date, downstream frequency range, diplex filter set
¹) CENELEC 41 channels, level at 862 MHz, 10 dB slope hinge at 1.2 GHz²) Setting via handheld / Wi-Fi module. Min. ratio between pilot frequency Pu and Po 250 MHz ³) Width incl. lid hinges: 267 mmAll data are typical values unless indicated otherwise.
Type VGE 1285-1G2 VGE 12258-1G2
Order no. 24410145 24410184
Forward path
Frequency range [MHz] 85-1218 258-1218
Gain (at 1218 MHz) ± 0.5 dB [dB] 12 12,5
Return loss, at and above 40 MHz [dB] 18 -1.5 dB/oct. min. 13 dB
Frequency response (85-1218 MHz at 25°C) [dB] ± 0.75 ± 0.5
Max. operating level to CENELEC - CTB > 67 [dB] ²) 95 105
Max. operating level to CENELEC - CSO > 64 [dB] ²) 95 105
Pre-emphasis (fixed) [dB] 10 11
Noise figure[dB] 7
Hum modulation at 7A [dB] 70
Return path
Frequency range [MHz] 5-65 5-204
Attenuation (fixed) ± 0.75 dB [dB] 2.5
Spurious (> 15 MHz) [dBµV] < 15
General data
Power supply [V AC] 30-72
Power consumption, max. [W] 5
Max. remote feed current (power passing) [A] 7
RF connections 5/8"
Housing protection class IP 65 ¹)
Ambient temperature range [°C] -40 to +60
Housing material Aluminum die cast
Overvoltage protection to IEC 60-2 6 kV (1.2/50 µs)
Dimensions (W × H × D) [mm] 142 x 113 x 68
¹) Providing a suitable plug is used ²) CENELEC, 41 channels output level @862 MHzAll data listed are typical values unless indicated otherwise.
Technical data
HFCHFC 3736
Type VOS 952-1G VOS 953-1G Comments
Network management
Parameters for remote management and configuration
Internal supply voltage, internal power consumption, internal temperature,
ICS switch
Test Points
Input test point (internal), two-way [dB] 20 Test point 1, 5-1006 MHz
Output test point (external), directional coupler [dB]
20
Test point 2, 5-1006 MHz, Return path signal injection (5-65 MHz). Push and hold
button to change direction and measure return path ingress
Return path test point (external), two-way [dB] 10 Test point 3, 5-65 MHz with
directional coupler
Switched mode power supply
Nominal input voltage [V AC] 110-230 38-65
Mains frequency range [Hz] 50-60
Power consumption (without monitoring) [W] 11 12
General data
Ambient temperature range [°C] -20 to +55
RF connections F socket
Test Points F socket
Protection protection class (to EN 60529) IP 54
Dimensions (W × H × D) [mm] 225 × 55 × 155
Weight [kg] 1.8
¹) CENELEC: 41 channels at 862 MHz²) When the 15 MHz high-pass filter is connected, the dynamic range increases by 3 dB. All data listed are typical values unless indicated otherwise.
Type VOS 952-1G VOS 953-1G Comments
Order no.24410162Locally fed
24410163 Remotely fed
Forward path
Frequency range [MHz] 47/85-1006
Gain (1 dB steps via slide switches) [dB] 1) 40 Interstage setting
Frequency response [dB] ± 0.75 85-1006 MHz, at 25°C
Frequency response (additionally from 862-1006 MHz) [dB]
-0.5 At 25°C
Attenuation range [dB] 0-16 At the amplifier input
Pre-emphasis range [dB] 0-16 and 0/8 At the amplifier input and
interstage
Noise factor [dB] 4/5/5 At 40/36/32 dB gain
Max. operating level: CENELEC channel plan [dBµV] 1) 112/116
CTB: 60 dB/CSO: 60 dB (pre-emphasis 6 dB and gain 40 dB)
Hum modulation ratio [dB] - > 60/70
Return path
Frequency range [MHz] 5-65
Gain switchable [dB] 30/21
Frequency response [dB] ± 0.75
Amplitude response [dB] 0.5
Attenuation range [dB] 0-16 and 0/4/8 At input/interstage
Pre-emphasis range [dB] 4) 0/3/6 Interstage
Ingress control switch (ICS) [dB] 0/8/> 40 Attenuated/switched off
Max. output level at 30 and 21 dB gain [dBµV] 107/11660 dB IMA2/IMA3
(EN 60728-3/50083-5)
Maximum output level acc. to KDG 1 TS 140 [dBµV]
120 Full system load
Input level density [dBµV/Hz] -10
Dynamic range at 30 dB gain (5-65 MHz) [dB] 2) 20
Dynamic range at 21 dB gain (5-65 MHz) [dB] 2) 30
Noise figure [dB] 5
See additional data on the next
Technical data
HFCHFC 3938
Type EAC 90-1G2 EAC 93-1G2 EAC 94-1G2 EBC 90-1G2
Order no. 24510215 24510216 24510220 24510214
Frequency range [MHz] 5-1218 5-1218 5-1218 5-1218
Through loss 5-15 MHz [dB] ¹) < 1.5 < 2.2 < 0.3 < 3.4
Through loss 15-65 MHz [dB] ¹) < 1.3 < 2.0 < 0.3 < 3.4
Through loss 65-862 MHz [dB] ¹) < 1.3 < 2.7 < 0.6 < 3.5
Through loss 862-1006 MHz [dB] ¹) < 1.5 < 3.1 < 0.7 < 3.7
Through loss 1006-1218 MHz [dB] ¹) < 1.6 < 3.1 < 0.9 < 3.9
Tap loss [dB] 10 6 20 Same as
through loss
Isolation / directional attenuation [dB] 28 28 28 26
Impedance [Ω] 75 75 75 75
Type EAC 90-1G EAC 93-1G EAC 94-1G EBC 90-1G
Order no. 24510116 24510115 24510114 24510113
Frequency range [MHz] 5-1006 5-1006 5-1006 5-1006
Through loss 5-610 MHz [dB] ¹) < 1.3 < 2.1 < 0.5 < 3.6
Through loss 610-862 MHz [dB] ¹) < 1.3 < 2.3 < 0.6 < 3.8
Through loss 862-1006 MHz [dB] ¹) < 1.5 < 2.6 < 0.9 < 3.9
Tap loss [dB] 10 6 20Same as
through loss
Isolation 5-65 MHz [dB] > 28 > 23 > 38 > 28
Isolation 65-610 MHz [dB] > 26 > 23 > 33 > 22
Isolation 610-862 MHz [dB] > 24 > 23 > 30 > 20
Isolation 862-1006 MHz [dB] > 22 > 20 > 28 > 18
¹) The through loss is the attenuation of the signal between the signal output of the device and output 1 if used in the output insert position or between the input and tap input if used in the input insert position (loop-through input splitter field)
Accessories
Type TVM 500 TVM 500S
Order no. 26210846 26210868
Input frequency range [MHz] 300-320; 425-450; 863-870; 902-928
Input level range [dBµV] 48-95
Impedance [Ω] 75
Power consumption [W] 0.4 0.2
Modulation type FSK
Suitable for device types Fiber nodes and controlled trunk /
distribution network amplifiersVGXxxxxD-1G2
Type TVM 1000
Order no. 26210086
Input frequency range [MHz] 90-862
Input level range [dBµV] 48-78
Output frequency range [MHz] 5-65
Max. output level [dBµV] 113-118
Power consumption [W] 3.5
Transmission protocol DOCSIS/EuroDOCSIS 2.0
Suitable for device types Fiber nodes, controlled trunk / distribution network amplifiers, house connection amplifiers
Type WTE 10
Order no. 25010086
WiFi standard IEE 802.11 b/g/n
Frequency range [GHz] 2.4
Encryption WPA, WPA2 AES PSK
Maximum transmission power [dBm] + 18
Power consumption [W] 3.5
Ambient temperature range [°C] -20 to +50
Housing protection class (to EN 60529)
IP 54
Technical data
HFCHFC 4140
Type Order no.
A
ALSCM 10 24510232
E
EAC 90-1G 24510116
EAC 90-1G2 24510215
EAC 93-1G 24510115
EAC 93-1G2 24510216
EAC 94-1G 24510114
EAC 94-1G2 24510220
EBC 00-1G2 24510217
EBC 01E-1G 24510119
EBC 90-1G 24510113
EBC 90-1G2 24510214
EMP 34 275289
EMP 35 275300
EMU 29 273243
ERC 22 24510085
ERD 813 24510117
ERD 814 24510120
ERD 815 24510127
ERP 101 24510128
ERR 9065 24510156
ERR 9085 24510158
ERR 9204 24510211
ERS 630 24510108
ERS 800 24510109
ERS 9085-1G2 24510219
ERS 9105-1G2 24510223
ERS 9258-1G2 24510210
ERZ 940 24510059
Type Order no.
T
TVM 1000 26210086
TVM 500 26210846
TVM 500S 26210868
V
VGE 12258-1G2 24410184
VGE 1285-1G2 24410145
VGP2143D-1G2 690017-xx1)
VGP3243D-1G2 690018-xx1)
VGX2143D-1G2 690019-xx1)
VGX 242D-1G2 24410188
VOS 952-1G 24410098
VOS 953-1G 24410099
W
WFS 906-1G2 24510218
WFS 908-1G2 24510222
WFS 920-1G2 24510209
WTE 10 25010086
Order number overview
Type ERC 22 ERZ 940 ERZ 630 ERS 800
Order no. 24510085 24510059 24510108 24510109
Transmission range [MHz] 50-862 47-862 47-630 47-862
Nominal impedance [Ω] 75
Pre-emphasis For C-lines < 2.0 - -
De-emphasis [dB] - 7 ± 1 - -
Equalisation, adjustable in 2 dB steps [dB] - - 2-18 -
Cable-equivalent pre-emphasis, 47-700 MHz/(equivalent to 47-862 MHz) [dB]
- - - 3/(4)
Cable-equivalent pre-emphasis in range 700-862 MHz [dB]
- - - 3
Basic loss (at 862 MHz) [dB] 1 0.3 - 0.5
Basic loss (at 47/630 MHz) [dB] - - 0.5/1.5 -
Return loss [dB] 23 -1/oct. typ. 20 min. 17 - > 15
Type ERD 813 ERD 814 ERD 815 ERP 101
Order no. 24510117 24510120 24510127 24510128
Transmission range [MHz] 85-1006
Nominal impedance [Ω] 75
Attenuation (linear) [dB] 1 6 10 1.8
Tap loss E -> A2 @ 85 MHz [dB] - - - 6
De-emphasis (862 MHz) [dB] 7 - - 3 ¹)
De-emphasis (1 GHz) [dB] 8 - - 4
Return loss [dB] 20 -1.5/octave 25 18.5 -1.0/octave
Type EBC 00-1G2 EBC 00-1G
Order no. 24510217 24510119
Frequency range [MHz] 5-1218 5-1006
Through loss [dB] ¹) 0.5
¹) The through loss is the attenuation of the signal between the signal output of the device and output 1 if used in the output insert position or between the input and the tap input of the device if used in the input insert position (splitter field loop-through input).
2) Based on 85-862 MHz
Technical data
1) Generic odering numbers. Please contact [email protected] for available configurations.
HFCHFC 4342
Notes
HFC44
11/2
018
Com
pact
Am
plifi
er
BKtel communications GmbH
Benzstrasse 4 41836 Hueckelhoven-Baal Germany Phone: +49 (0) 24 33 / 91 22-0 Fax: +49 (0) 24 33 / 91 22-99
Office Kornwestheim: Bahnhofstrasse 82 70806 Kornwestheim Germany Phone: +49 (0) 71 54 / 1 59 90-0 Fax: +49 (0) 71 54 / 1 59 90-77
BKtel networks GmbH
Mangfallstrasse 3783026 Rosenheim Germany Phone: +49 (0) 80 31 / 7 96 75-0 Fax: +49 (0) 80 31 / 7 96 75-99
Internet: www.bktel.com Email: [email protected]
Representations:
BKtel Pacific Rim (Japan) Inc. Katsukou Building 5F 1-2-8, Hourai-cho, Naka-ku, Yokohama, Kanagawa 231-0048, Japan Phone: +81 45 350 5447 Fax: +81 45 350 5460 BKtel LatamOficina de RepresentaciónPedro Torres n.º 231, planta 302Municipalidad de ÑuñoaSantiago, ChilePhone: +56 220 468 46Email: [email protected]
BKtel local representatives:
France: André Balva [email protected]
South East Asia: Roland Wuerth [email protected]
Top Related