LUBE-OIL ANALYSIS
Gas turbine firing tempera-tures continue to increaseas OEMs relentlesslychase efficiency improve-
ments. This demands that lubricantmanufacturers formulate productscapable of withstanding the more
rigorous service conditions. Com-pounding the challenge are theowner/operators, who want turbineoils to last longer.
To meet these demands, tur-bine oils have undergone significantchanges over the last decade or so.For example, base oils have changedfrom Group I (solvent-refined) toGroup II (hydrotreated).Important to plant per-sonnel is that Group IIbase stocks, while moreoxidation-resistant, havea lower solvency, whichmeans varnish issues are areal possibility.
The antioxidants addedto protect the fluid also havechanged. Combinations ofantioxidants, referred to ascomplex additive packages,are used to take advantageof the synergies among thevarious constituents.
Fluid degradation.Critical to optimizing yourlube-oils life expectancy is under-standing how a lubricant degrades
(Fig 1) and what tests are availableto measure the amount of degrada-tion. Oxidation and/or heat are whatcause Group 1, Group 2, and syn-thetics to degrade.
Generally, oxidative degradationdoubles for every 18-deg-F increasein lube-oil temperature. Group I oilsare the most susceptible to this typeof degradation because they containthe highest levels of unsaturates andimpurities. The initial degradationproducts are aldehydes, ketones, andcarboxylic acids; they undergo fur-
ther reaction to form higher molecu-lar-weight products. As these byprod-ucts combine, sludge and varnish areformed.
Test methods
One of the first tests designed to mea-sure a turbine fluids ability to resistoxidation was the Rotating Pressure
Vessel Oxidation Test (RPVOT, ASTMD2272). In this test, the fluid is sub-
jected to pressure and heat in thepresence of water, oxygen, and a cop-per catalyst inside an enclosed vessel.Pressure drop indicates when the fluidis oxidizedthat is, once it absorbs(reacts with) the oxygen. The time ittakes for the pressure to drop by a pre-determined amount is the end point.
The older Group I fluids typi-
cally had RPVOT values of about 600minutes or less. Group II fluids with
sophisticated additive packages mayhave values in excess of 3000 min-utes. ASTM D4378 (Standard Prac-tice for In-Service Monitoring of Min-eral Turbine Oils for Steam and GasTurbines) states that oil should bechanged when its RPVOT falls below25% of the RPVOT for that same oilwhen it was new.
The universal validity of RPVOTtest results have been called intoquestion by some industry expertsrecently because of issues regard-ing repeatability and reproducibility
with at least some new oils. However,RPVOT is still listed routinely onmost oil manufacturers product datasheets and remains the most widely
used indicator of a fluids oxidativecondition.
Running the RPVOT test regular-ly helps in predicting the fluids use-ful life. ASTM D4378 recommendsthat RPVOT testing be done annu-ally, and more frequently as the fluid
ages. RPVOT does not necessarilydecrease linearly. A recent analysisof data from tests performed at regu-lar intervals on several oils foundthat the RPVOT results for some flu-ids decreased linearly while those forothers did not.
Fig 2 shows three possible waysin which a fluids RPVOT may
decrease. Keep in mind thatthese results are from testsrun under controlled labora-tory conditions. Under fieldconditions, the odds are evenhigher that RPVOT will notdecay linearly. Note, too,that RPVOT was not devel-oped as a means for compar-ing oilsthat is, for com-paring the absolute RPVOTvalues of alternative fluidsagainst each other. Rather,its value is in charting thedecrease in RPVOT for agiven fluid.
Two relatively newtests useful for assess-
ing a fluids oxidative health areQSA (Quantitative Spectrophoto-
metric Analysis, Analysts Inc) andRULER (Remaining Useful LifeEvaluation Routine, Fluitec Inter-national). Though neither of thesetests measures a fluids ability toresist oxidation under simulatedconditionsas RPVOT doestheydo provide useful information abouta fluids oxidative health.
Traditional oil analysis, while avaluable preventive maintenancetool, is unable to detect varnish orvarnish precursors. By contrast, QSAis designed to detect varnish precur-
sors. The amount of soft contami-nants present in a sample is quanti-fied using a spectrophotometer and isreported by use of a proprietary scale,
Fluid analysis critical to
maximizing lube-oil service lifeGene Wagenseller, CLS, OMA II, Analysts Inc
Hydrocarbon
Oxidativedegradation
Initialpolymerization
Varnish and sludge(oxygenatedinsolubles)
Thermaldegradation
Hot metalsurfaces/electrostatic
discharge
Carbon deposits
Air entrainment(adiabatic
compression)
Varnish fromcarbon insolubles
1. Understanding howhydrocarbons degrade isimportant for maximizinglube-oil life expectancy
8/3/2019 Combined Cycle Journal Q4 Issue 2009
2/4
COMBINED CYCLE JOURNAL, Fourth Quarter 2009 61
developed by correlating lab resultswith known instances of varnish
occurrences in field studies.QSA has proven more reliable
for predicting varnish than alterna-tives such as the ultracentrifuge. Itis recognized by several OEMs asthe preferred method for varnishtesting. Fig 3 illustrates the VarnishPotential Rating (VPR) for a Frame 7engine at a combined-cycle plant.
RULER works on the principlethat some chemical speciessuch asantioxidantsare electrochemicallyactive. A compound is considered elec-trochemically active if, when a voltage
is passed through a solution contain-ing that compound, current flows.Different chemical species respondat different voltages. The amount of
antioxidant is directly related to theamount of current produced.
By increasing the applied voltageat a constant rate, one can develop agraph that reveals the antioxidantspresent. The quantity of antioxidantsremaining in the fluid can be calculat-ed as a percentage of the initial amountby comparing the area under the curvecreated for the oil in service to that forthe same oil when new (Fig 4).
Thus RULER measures the amountof antioxidants remaining in the fluid,not the oils useful life. This is impor-tant because some of the degradationproducts from the antioxidants may
themselves be antioxidants.RULER also requires a referencefluid to calculate the percentage ofadditives remaining, which may limit
its effectiveness in some situations.Heres why: Some gas-turbine fluids
may remain in service for 10 years,steam-turbine oils even longer. Overthe years, the original fluid may havebeen reformulated or topped off witha different product. The resultingfluid mixture could complicate inter-pretation of RULER results.
However, the test has severaladvantages, including: small samplesize, rapid analysis; plus, techniciansrequire little training to perform thetest.
The bottom line: RPVOT, RULER,and QSA each provide valuable infor-
mation regarding the health of yourturbine oil. Including all as part ofyour fluid-analysis program enablesthe most accurate decision-making.
Test A Test CTest B
RPVOT
1400
1200
1000
800
600
400
200
00 500 1000 1500 2000
Time, min
2. Data from tests under controlled laboratoryconditions illustrate how RPVOT may decrease
72Abnormal
QSA patch
QSAnumber
100
80
60
40
20
0
15
28
46
48
5864
58
72
4/19/05 10/19/05 4/19/06 10/19/06 4/19/07 10/19/07 4/19/08 10/19/08
3. Varnish Potential Rating for a Frame 7 engine increasedunchecked for years
+1 219-663-1600 www.janusfiresystems.com
1102 Rupcich Drive, Crown Point, IN 46307
Manufacturer and Designer of Globally
Approved Fire Extinguishing Systems
Manufacturer and Designer of Globally
Approved Fire Extinguishing Systems
Clean Agent
High Pressure Carbon Dioxide
Low Pressure Carbon Dioxide
Water Mist
Foam
Alarm and Detection
Air Sampling Smoke Detection
Clean Agent
High Pressure Carbon Dioxide
Low Pressure Carbon Dioxide
Water Mist
Foam
Alarm and Detection
Air Sampling Smoke Detection
YOUR GATEWAY TO A NEW KIND OF SERVICE.YOUR GATEWAY TO A NEW KIND OF SERVICE.
8/3/2019 Combined Cycle Journal Q4 Issue 2009
3/4
62 COMBINED CYCLE JOURNAL, Fourth Quarter 2009
Condition-basedmaintenance
Lubricating oil is changed by someusers on a fixed schedule. Thisapproach, while convenient, does notassure optimum machine and fluidlife. Oil changed prematurelyincreases the cost of lubrica-tionyou wind up buying morenew fluid than you need and payfor disposal of oil that may stillhave some life in it. By contrast,if fluid remains in service beyondits useful life, you place criticalrotating equipment at risk. If aforced outage results, revenue
loss could be significant.More cost-effective is sched-uling preventive maintenance on acondition-based approach. A condi-
tion-based lube program relies on theresults of fluid analyses to maximizethe use of your oil, thereby minimiz-ing the life-cycle cost of lubrication.
Decisions involving lube-oil recon-ditioning and replacement demandcareful consideration and planning. Toillustrate: Replacement requires thattime be budgeted for review of alter-native fluids, the purchasing process,delivery, etc. In addition, cleaning andflushing of the lube system may be nec-essary to maximize the effectiveness ofthe new oil and to return performanceto as new. Arrangements for safe dis-posal also must be made.
What follows are three examplesof how fluid analysis was used to
decide between lubricant replace-ment and conditioning.
Case history 1. A combined-cycleplant annually assessed the condi-
tion of its turbine fluids. After the2008 turbine lube assessment, plantpersonnel questioned whether thefluid would be suitable for continueduse until the next scheduled outagein fall 2009. Options included replac-ing the lube oil, removing existingvarnish and precursors with a provenclean-up technology and/or toppingoff the existing fluid.
Because the plant had been test-ing its fluids regularly to assess oxi-dative stability, meaningful datawere available for predicting the flu-ids expected condition a year hence(Fig 5). Data extrapolation indicatedthat the fluids RPVOT would bewell below the 25% minimum recom-
mended by ASTM D4378 and mostturbine manufacturers.
Additionally, RULER predictedonly 10% of the antioxidants would
remain by the fall 2009 outage.Based on this information, the plantopted to change the fluid ratherthan risk an unscheduled outagebecause of fluid failure.
Case history 2. A plant experi-enced varnish-related trips on bothof its Frame 7s, which had beencharged with new lube in 2007. QSAresults revealed that both lube-oil
systems had critical levels of var-nish present. Fig 6 presents testdata for one of the turbines.
Interestingly, both the RPVOT and
The Everest Cycle produces cool inlet air with low
moisture content and lower parasitic loads resulting in
greater net power and lower net heat rate.
Cooler than direct
evaporative
Less power draw than refrigeration
Best CO2 Emissions
Compatible with bad water
Modular installation and
www.EverestSciences.com/Indirect 918.270.9965 [email protected]
Turbine Inlet Cooling ...period
Let us show you how INDIRECT EVAPORATIVE Cooling can improve your bottom line.
2010 WorkshopJune 8-10
The Bahia Resort inMission Bay, San Diego
Organizers:
Frank Spencer([email protected])
and Bill Stroman
Host:
Capital Power Corp
0 5 10 15
600
400
200
0RULERnumber
Seconds
Sam
ple
Newoil
QSA
RULERRPVOT,%ofnewoil
2005 2006 2007 2008 2009 2010
90
70
50
30
10
0QSAandRULERnumbers;
PRVOT,
%o
fnewoil
4. Antioxidants remaining in lube oilcan be calculated as a percentage ofthe initial amount by comparing theareas under the curves for both sumpand new oil
5. Meaningful data can be extrapo-lated to estimate when new oil will beneeded
8/3/2019 Combined Cycle Journal Q4 Issue 2009
4/4
COMBINED CYCLE JOURNAL, Fourth Quarter 2009 63
RULER values are within acceptablelimits. Recall that those tests focuson antioxidant levels, not the fluidstendency to form varnish, so theymight not provide adequate warn-ing for the user in situations suchas this.
The plant was remiss in notassessing the condition of its turbine
oils at least annually and personnelwere caught off-guard with the var-nish problem. At this plant, varnishbuild-up was such that it was diffi-cult to remove. Three different typesof varnish mitigation technologieswere tried without success.
In cases such as this, if varnish can-not be removed, the plant may have todrain the oil and possibly chemical-flush the system before rechargingwith fresh oil. Lesson learned: It ismuch better to deal with lubricantissues early, before the problem has
reached the critical stage.The first two scenarios illustrate
the difference between proactive andreactive maintenance philosophies.
At the first facility, proactive fluidanalysis enabled management toweigh benefits and risks and makean informed decision. The secondplant has lost production time andmay have to change the oil prema-turely.
Case history 3. An F-class com-bined-cycle facility became awareof varnish formation in lube oilsthrough the OEMs TIL-1528 andbegan performing the QSA test reg-ularly. A small QSA spike severalyears ago prompted investigation ofthe various varnish removal technol-ogies available and the plant optedto install an electrostatic process.
For several years test results havebeen very favorable. Recently, how-ever, the varnish potential increased(Fig 7). The plant has an outagescheduled for later this year; thefirst one after that will be in 2012. Sowhat to do this year questions areon the minds of plant supervisors.
Had the plant been performingRPVOT and RULER tests regularly,supervisors would be better equippedto determine the reason for the lat-est spikespecifically, if the increasein varnish potential was a result ofdiminished additive levels and insuf-
ficient oxidative reserve to providefluid protection. Only by having allthis information, can you make aninformed decision on fluid replace-ment now or in 2012.
Another lesson learned: Just hav-
ing a proactive approach to varnishcontrol is not enough. A completefluid-analysis program is neededto provide sufficient informationfor decision-making regarding fluidchange-out. ccj
120
100
80
60
40
20
0
2007 2008 2009QSAandRULERnumbers;
PRVO
T,
%o
fnewoil
QSA
RULERRPVOT,%ofnewoil
6. QSA test data revealsharp increase in varnishpotential (left)
7. First spike on the QSAplot prompted investiga-
tion of varnish removaltechnologies. An electro-static process was select-ed for this plant (right)
QSAnumber
40
30
20
10