Download - C LIMATE C ORPS B AY A REA 2012 T RAINING Kif Scheuer.

Transcript

CLIMATE CORPS BAY AREA 2012 TRAINING

Basic Energy AuditsKif Scheuer

CLIMATE CORPS BAY AREA 2012 TRAINING

Types of Linear Fluorescent Light Fixtures

CLIMATE CORPS BAY AREA 2012 TRAINING

Components of Fluorescent Lighting System

Lamps

Ballast

LightFixture

CLIMATE CORPS BAY AREA 2012 TRAINING

Types of Linear Fluorescent Lamps

Source: http://plutarco.disca.upv.es/~jcperez/doctorado/SV2D3DPI/energy.arce.ukans.edu/book/sources/low.htm

T12

T8

T5

T2

CLIMATE CORPS BAY AREA 2012 TRAINING

Energy Audit #1: T12 vs. T8 Fluorescent Lamps

T8 LampsLamp Type fixture Watts24" T8 1 lamp 1524" T8 2 lamp 2824" T8 3 lamp 4124" T8 4 lamp 5736" T8 1 lamp 2336" T8 2 lamp 4236" T8 3 lamp 6236" T8 4 lamp 8448" T8 1 lamp 2548" T8 2 lamp 5448" T8 3 lamp 7348" T8 4 lamp 94 T8/U-bend 1 lamp27T8/U-bend 2 lamp52

T12 LampsLamp Type fixture watts24" T12 1 lamp 2824" T12 2 lamp 5624" T12 3 lamp 6224" T12 4 lamp 11236" T12 1 lamp 3236" T12 2 lamp 6536" T12 3 lamp 11536" T12 4 lamp 13648" T12 1 lamp 4048" T12 2 lamp 7248" T12 3 lamp 11248" T12 4 lamp 142T12/U-bend 1 lamp 34T12/U-bend 2 lamp 66

CLIMATE CORPS BAY AREA 2012 TRAINING

How to tell if a light fixture has T12 vs. T8 lamps?

Spin the flicker checkerChoppy, checkered pattern= magnetic ballast = T12

lampConcentric, gray rings = electronic ballast = T8 lamp

CLIMATE CORPS BAY AREA 2012 TRAINING

T12 vs T8 ActivityActivity Instructions:

Break up into teams of 3-4, grab a flicker checker, and select a specific site to conduct a linear fluorescent light audit, specifically looking at existing T12/T8 lamps in the building.

Use the worksheet provided to collect information on the study site’s existing lighting condition.

Calculate the potential electricity, cost, and GHG savings associated with upgrading the existing lighting conditions, if an upgrade is needed.

CLIMATE CORPS BAY AREA 2012 TRAINING

Energy Audit #3 - Delamping:

What is it, and why is it important?

CLIMATE CORPS BAY AREA 2012 TRAINING

Recommended Lighting Levels

Source: Illuminating Engineering Society

Developed by the Illuminating Engineering Society

CLIMATE CORPS BAY AREA 2012 TRAINING

How to Use a Light Meter

How To Use It

Make sure the sensor is covered.

Check that the “Range” switch is selected to A

Turn on the “Power” button.Remove the sensor cover.Read the lighting level.

Readings should be taken at the level where the work occurs.

Make sure user does not cover the sensor

CLIMATE CORPS BAY AREA 2012 TRAINING

Layout of room:

Sample light levels collected from room:

3 linear fluorescent fixtures

Light Meter ActivityConduct a light analysis of the room/building you are in. Example:

CLIMATE CORPS BAY AREA 2012 TRAINING

Light Meter ActivityActivity Instructions:

Break up into teams of 3-4, grab a light meter, select a specific site to conduct a light meter analysis in the building.

Draw a floor plan of the study site as shown in the previous slide, and write down different light meter levels (foot-candles). Collect at least 6 light meter levels in different parts of the room.

Based on the recommended lighting level, assess if there is too much/too little light in the study site, and what next steps you would recommend to the facilities staff to help them save energy.

CLIMATE CORPS BAY AREA 2012 TRAINING

What’s a plug load? Plug loads make up about 4% of all electricity

use in the US What’s a run watt?

Power drawn by a plug load while in operation What’s a phantom load?

Aka energy vampires, standby loads U.S. consumption of phantom loads = electricity use of

Greece, Peru, and Vietnam, combined.

Energy Audit #3: Plug Loads and Phantom Loads

Phantom load on this printer is 2.8 watts.

This translates into _______kWh a year.

CLIMATE CORPS BAY AREA 2012 TRAINING

Typical Appliance Energy Use

CLIMATE CORPS BAY AREA 2012 TRAINING

Plug Load ActivityActivity Instructions:

Break up into teams of 3-4 and pick at least one plug load and one watt meter.

Using the handout, calculate the run watts and the phantom load (if any), along with the associated annual energy use, cost, and GHG emissions.

Handout: