l Two-in-One: Two identical inverters,synchronized output voltages
Significantly reduced weight byaluminum frame design
Bottom access for easy removalof all modules
Two redundant fans,operating in daily alternationto reduce Life Cycle Costs
Comprehensive diagnostics system“TTProDiag” incl. troubleshooting help
CAN bus interface to train control
l
l
l
l
l
l
Integrated intelligent load management
Auxiliary Power Unit for Light Rail Vehicle
Bomb-280
Illustration: Bombardier
DC/AC-AC-AC-DC-DC-DC auxiliary power unit, Bomb-280 LRV
750 VDC
750 V DC9 kW
750 V DC9 kW
CANRS-232
48 V DC15 kW
3 x 480 V60 Hz45 kVA
3 x 480 V60 Hz45 kVA
220 V AC60 Hz5 kVA
=
3
=
=
3
DC Control
Converter Control
AC Control 1
AC Control 2
Transtechnik GmbH & Co. KG . Ohmstrasse 1 . 83607 Holzkirchen . Germany . Phone +49-8024-990-0 . Fax +49-8024-990-300Internet: http://www.transtechnik.com . email: [email protected]
Input
Three-phase AC outputs
Single-phase AC output
DC output
General
Nominal input voltageOperating range
Output voltageFrequencyContinuous powerMax. output powerTHD
Output voltageFrequencyContinuous power
750 V DC525 V through 900 V DC
3 x 480 V AC + 5.4% / – 10%60 Hz2 x 45 kVA, cos = 0.852 x 66 kVA (5 s), cos = 0.5< 8%
1 x 220 V AC60 Hz5 kVA
Nominal battery charging voltageLV nominal voltageOutput powerMax. output currentCharging characteristic
EfficiencyTemperature rangeHumidity
Cooling
Dimensions in mmWeightMounting
LVPS / battery charger54 V DC ± 0.25 V48 V DC15 kW288 AI/V characteristic,temperature compensated
> 92%–29 °C through +49 °C20% through 100%
forced air cooled,two fans1290 x 1498 x 686482 kgunderframe-mounted
Technical data
Block diagram
DC/AC-DC Bordnetzumrichter, Typ GTW
RG.Bomb-280_e_060802
Type: U750DC/480AC3-480AC3-220AC-48DC-750DC-750DC/P45-45-5-15-9-9/F60