Baldor Large AC Motor Quick-Ship (QS) Program
Custom Above NEMA AC Motors in 2 weeks!Baldor customers have come to expect same day deliveries
of stock Super-E® Premium Efficient motors from their local
Baldor District Office or the Ft Smith Distribution Center. Now
Baldor Large AC customers can choose from a broad list of
design options to build a custom motor that fits their application
requirements. Baldor will ship that motor within 2 weeks from
when the order is received.
The QS program is made up of the following motors:
• 200 HP through 800 HP
• 449 through 5000 frames
• TEFC
• 2, 4 and 6 pole
• 2300/4000 volt, form wound
• 460 or 575 volt, random wound
• 3 phase, 60 hertz
• 1.0 service factor, Class B rise
• 1.15 service factor, Class F rise
• Anti friction bearings for coupled or belted duty
The following popular options are available for the QS program:
• 100 ohm winding RTDs, 2 per phase
• Bimetallic winding thermostats
• Bearing RTDs
• Provisions for Bearing RTDs
• Vibration detection (Bracket Velocity)
• Provisions for vibration detection (Bracket Velocity)
• Space heaters
• Severe duty “XTS” construction
• Inverter duty 4:1 constant torque (low voltage only)
• Inpro/Seal® bearing isolators
• Shaft modifications
• Belted duty with roller bearings
• C-Face
• D-Flange
• Auxiliary (stainless steel) conduit box
• Oversized conduit box
• Rerate for 50HZ or Div II
Effective Oct 1, 2010
Baldor Large AC Motor Quick- Ship, (QS) Program
Time proven designs make it possible for Baldor-Reliance Large AC motors to deliver outstanding performance and exceptional value. With this in mind every stock or QS custom motor design begins with a solid foundation that includes these features:
• Premium Efficiency exceeding 95%
• SolidCure™ Class F VPI insulation
(Medium Voltage)
• Cast iron frame, inner bearing caps and
end brackets to ensure true alignment and
minimum vibration
• Rugged die cast aluminum rotor for better heat
dissipation and longer life
• Bi-directional rotation
• Dual mounting holes, which is especially convenient for replacement
motors
• F1 to F2 field rotatable conduit box
• PLS lubrication system with grease fittings and grease relief
• Corrosion resistant hardware
FlexFlow manufacturing and quality disciplines make it possible for Baldor
to build custom Motors in 2 weeks and still maintain reliability in
critical applications.
Baldor's engineering and manufacturing
capabilities are a big part of why
Baldor is the most preferred supplier
of industrial motors in North America.
Baldor Above NEMA motor plants
employ Lean FlexFlow principles and
the latest technologies that yield greater
productivity, more flexibility and less setup
time. As you might expect, quality is a leading
priority throughout all Baldor plants. Six Sigma Quality
practices including SPC process control, begin at the start of
the manufacturing process where raw materials such as magnet wire and
electrical steel enter the plant. This scrutiny continues during the build
process where components and sub assemblies are repeatedly tested
for conformance to engineering specifications. For example, after the
stator laminations are punched, random samples are tested for geometric
consistency within each slot and between slots. Even during the final
paint process, quality is still the priority because Baldor knows that paint
durability and appearance are important to their customers.
Manufacturing leadership and attention to quality ensures performance
predictability for every Baldor-Reliance motor produced in these plants.
Baldor Large AC Motor Quick- Ship, (QS) Program
TEFC G5000
Dual foot mounting holes
Frame Bearing C 2F X2F XBA N U
G5008S Anti Friction 60.14 25.00 22.00 15.50 6.84 4.13
G5008L Anti Friction 64.14 25.00 22.00 19.50 10.84 4.13
G5010S Anti Friction 67.14 32.00 28.00 15.50 6.84 4.13
G5010L Anti Friction 71.14 32.00 28.00 19.50 10.84 4.13
G5012S Anti Friction 75.14 40.00 36.00 15.50 6.84 4.13
G5012L Anti Friction 79.14 40.00 36.00 19.50 10.84 4.13
“Typical” dimensions for all QS Program motors
TEFC G5000 – Anti Friction BearingDrawing 616836-326
TEFC G449 – Anti Friction BearingDrawing 617423-001
"N"
"X2F"
"2F"31.00
10.00
"C"
"U" 3
34.18.12
15.82
7.91
"V""ES"
7.00"BA"
"N-W"
"XBA"
9.75
6.00 6
1
"S" SQ.KEY
9.00
18.00
10.99
2
24.24
24.47
19.22
22.00
14.92
7.00
7.46
1.24
28.21
9.00
4.60
24.49
6.34
14.47
"S"
14.16
13/166 HOLES
4 4.00 LEAD OPENING
DUTY MASTER ALTERNATING CURRENT MOTORS
GROUND HOLES QTY 1 1/2-13 TAP; QTY 1 3/8-16 TAP1.VARIES +.00,-.062.VARIES +.000,-.0013.ON STANDARD MOTORS THIS IS CONDUIT SIZE. ON XT AND 4.CORROSION PROOF MOTOR THIS IS PIPE TAP.MOTOR WEIGHTS MAY VARY BY 15% DEPENDING ON RATING.5.OBSTRUCTION MUST NO ENCROACH ON AIR INLET6.
CONDUIT BOX LOCATED ON OPPOSITE SIDE WHEN F-2.IF MOUNTING CLEARANCE DETAILS ARE REQUIRED, CONSULT FACTORY. MAXIMUM PERMISSIBLE SHAFT RUNOUT WHEN MEASURED AT END OF STANDARD SHAFT EXTENSION IS .003" T.I.R. TO 5 INCH DIA.
CUSTOMER IS RESPONSIBLE FOR DETERMINING THAT MOTOR PERFORMANCE IS SUITABLE IN THE APPLICATION.
SQUIRREL-CAGE INDUCTION
ENCLOSURE:
MOUNTING:
COOLING:TOTALLY ENCLOSED
FOOT
FAN COOLED
INCLUDES 447 FRAME MOUNTING HOLES
FRAME 449 ABOVE NEMA RATINGS
FRAME BEARING C 2F X2F BA XBA N N-W V U ES SG449TS ANTI-FRICTION 49.48 25.00 20.00 7.45 12.26 4.84 4.81 4.75 2.375 3.03 .626G449T ANTI-FRICTION 53.24 25.00 20.00 7.45 16.01 8.59 8.50 8.39 3.375 6.91 .875
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
E
F
E
F
C
01617423-001
06/23/2010A
MGHJH8
ACTIVATE DRAWING
REF:TDR:VERSION:
MODEL NO.REVISED:
BY:
REV:REV. DESC:
DIM SHEET G449 TEFC
TEFC G449
Frame Bearing C 2F X2F BA XBA N N-W V U S S
G449TS Anti Friction 49.48 25.00 20.00 7.45 12.26 4.84 4.81 4.75 2.375 3.03 .626
G449T Anti Friction 53.24 25.00 20.00 7.45 16.01 8.59 8.50 8.39 3.375 6.91 .875
Note: Only use “Certified Prints” for construction and installation
Baldor Electric CompanyP.O. Box 2400 • Fort Smith, AR 72902-2400 U.S.A.
Phone (479) 646-4711 • Fax (479) 648-5792© Baldor Electric CompanyFL435
Printed in U.S.A.08/10 TCP 5,000www.baldor.com
Baldor Large AC Motor Quick- Ship, (QS) Program
Stock and Quick Ship Overview Stock Motor Catalog Number
Quick Ship Reference Number
HP RPM Frame 2300/4000 Volts 460 Volts 575 Volts
200 3600 G449TS ECP44202T-2340 EQST44202S-2340 – –
200 1800 G449T ECP44204T-2340 EQST44204L-2340 – –
250 3600 G5008S ECP50252S-2340 EQST50252S-2340 – –
250 1800 G5008L ECP50254L-2340 EQST50254L-2340 EQST50254L-4 EQST50254L-5
250 1200 G5008L ECP50256LR-2340 EQST50256L-2340 – –
300 3600 G5008S ECP50302S-2340 EQST50302S-2340 – –
300 1800 G5008L ECP50304L-2340 EQST50304L-2340 EQST50304L-4 EQST50304L-5
300 1200 G5010L ECP50306LR-2340 – – –
350 3600 G5008S ECP50352S-2340 – – –
350 1800 G5008L ECP50354L-2340 EQST50354L-2340 EQST50354L-4 EQST50354L-5
350 1200 G5010L ECP50356LR-2340 EQST50356L-2340 – –
400 3600 G5010S ECP50402S-2340 EQST50402S-2340 – –
400 1800 G5008L ECP50404L2340 EQST50404L-2340 EQST50404L-4 EQST50404L-5
400 1200 G5012L ECP50406LR-2340 EQST50406L-2340 – –
450 3600 G5010S ECP50452S-2340 – – –
450 1800 G5010L ECP50454L-2340 EQST50454L-2340 EQST50454L-4 EQST50454L-5
450 1200 G5012L – – – –
500 3600 G5010S ECP50502S-2340 EQST50502S-2340 – –
500 1800 G5010L ECP50504L-2340 EQST50504L-2340 EQST50504L-4 EQST50504L-5
500 1200 G5012L ECP50506LR-2340 EQST50506L-2340 – –
600 3600 G5010S ECP50602S-2340 EQST50602S-2340 – –
600 1800 G5012L ECP50604L-2340 EQST50604L-2340 EQST50604L-4 EQST50604L-5
600 1200 G5012L – EQST50606L-2340 – –
700 1800 G5012L – EQST50704L-2340 EQST50704L-4 EQST50704L-5
800 1800 G5012L – EQST50804L-2340 EQST50804L-4 EQST50804L-5
NOTE: Stock motors are built as severe duty with space heaters, winding RTDs and other options. 6-Pole "LR" motors have oversize shafts with roller bearings for heavy belted loads.
The following popular options are available for the QS program:• 100 ohm winding RTDs, 2 per phase
• Bimetallic winding thermostats
• Bearing RTDs
• Provisions for Bearing RTDs
• Vibration detection (Bracket Velocity)
• Provisions for vibration detection (Bracket Velocity)
• Space heaters
• Severe duty “XTS” construction
• Inverter duty 4:1 constant torque (low voltage only)
• Inpro/Seal® bearing isolators
• Shaft modifications
• Belted duty with roller bearings
• C-Face
• D-Flange
• Auxiliary (stainless steel) conduit box
• Oversized conduit box
• Rerate for 50HZ or Div II
Baldor Electric's Above-NEMA AC motors are available from stock and may be ordered by the Catalog Numbers shown below for 2300/4000 volt
designs. These motors should be in stock at a Baldor warehouse. If a customized motor is desired in 460, 575 or 2300/4000 volt designs, the reference
number below can be combined with the options shown below the table. Quick ship motors have a 2-week lead time.
Top Related