Digital Storage OscilloscopesTDS1000B Series Data Sheet
Features & Benefits40 MHz, 60 MHz, and 100 MHz BandwidthsSample Rates up to 1 GS/s Real Time2 ChannelsMonochrome LCD DisplayRemovable Data Storage using the Front-panel USB PortSeamless PC Connectivity through the USB Device Port, withOpenChoice® and NI SignalExpress® PC SoftwareAdvanced Triggers including Pulse Width Trigger and Line-selectableVideo TriggerFFT Standard on All Models12 Automatic MeasurementsMultiple-language User Interface and Context-sensitive HelpDirect Print to All PictBridge®-compatible Printers through the USBDevice PortLifetime Warranty*1
ApplicationsDesign and Debug
Education and Training
Manufacturing Test and Quality Control
Service and Repair
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176TestEquipmentDepot.com
99 Washington Street Melrose, MA 02176 Phone 781-665-1400Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
Data Sheet
Quickly and easily capture waveforms.
TDS1000B Series OscilloscopesInstantly Productive. Incredibly Easy.The TDS1000B Series digital storage oscilloscopes deliver an unbeatablecombination of performance and ease of use, at a price you can afford.
Affordable Digital PrecisionWith up to 100 MHz bandwidth and 1 GS/s maximum sample rate, no otherdigital storage oscilloscope offers as much bandwidth and sample rate forthe price. The TDS1000B Series oscilloscopes provide accurate real-timeacquisition up to their full bandwidth, the same record length at all time basesettings, advanced triggers to isolate signals of interest, and 12 standardautomatic measurements on all models. Their Fast Fourier Transform (FFT)and waveform add, subtract, and multiply math functions allow you toanalyze, characterize, and troubleshoot circuits.
Quick and EasyWaveform CaptureThe simple user interface with classic analog-style controls makes theseinstruments easy to use, reducing learning time and increasing efficiency.Innovative features such as the Autoset Menu, Probe Check Wizard, andContext-sensitive Help Menu optimize instrument setup and operation.
Flexible Data TransferWith USB host and device ports which enable removable data storage,seamless PC connectivity, and direct printing, no other digital storageoscilloscope offers as much flexibility and ease of data transfer for the price.
Simple Documentation and AnalysisEasily capture, save, and analyze measurement results with OpenChoicePC Communications Software. Simply pull screen images and waveformdata into the stand-alone desktop application or directly into MicrosoftWord and Excel. To complement OpenChoice, National Instruments
Conveniently use your USB flash drive to store screenshots and waveform data.
Easily capture, save, and analyze measurement results with OpenChoice PCCommunications Software.
SignalExpress Tektronix Edition Software provides you with extendedcapabilities, including advanced analysis, remote oscilloscope control, andlive waveform analysis. Alternatively, if you prefer not to use the PC, youcan simply print your image directly to any PictBridge-compatible printerusing the USB device port.
Performance You Can Count OnDepend on Tektronix to provide you with performance you can count on. Inaddition to industry-leading service and support, every TDS1000B Seriesoscilloscope comes backed with a Lifetime Warranty*1 as standard.
Digital Storage Oscilloscopes — TDS1000B Series
CharacteristicsTDS1000B Series Digital Storage OscilloscopesCharacteristic TDS1001B TDS1002B TDS1012BDisplay(1/4 VGA LCD)
Mono
Bandwidth*2 40 MHz 60 MHz 100 MHzChannels 2External TriggerInput
Included on all models
Sample Rate onEach Channel
500 MS/s 1.0 GS/s 1.0 GS/s
Record Length 2.5K points at all time bases on all modelsVertical Resolution 8 bitsVertical Sensitivity 2 mV to 5 V/div on all models with calibrated fine adjustmentDC VerticalAccuracy
±3% on all models
Vertical Zoom Vertically expand or compress a live or stopped waveformMaximum InputVoltage
300 VRMS CAT II; derated at 20 dB/decade above100 kHz to 13 Vp-p AC at 3 MHz
Position Range 2 mV to 200 mV/div +2 V; >200 mV to 5 V/div +50 VBandwidth Limit 20 MHz for all modelsInput Coupling AC, DC, GND on all modelsInput Impedance 1 MΩ in parallel with 20 pFTime Base Range 5 ns to 50 s/divTime BaseAccuracy
50 ppm
Horizontal Zoom Horizontally expand or compress a live or stopped waveformI/O Interfaces
USB Ports USB host port on front panel supports USB flash drivesUSB device port on back of instrument supports connection
to PC and all PictBridge-compatible printersGPIB Optional
Nonvolatile StorageReferencewaveformdisplay
(2) 2.5K point reference waveforms
Waveformstorage withoutUSB flash drive
(2) 2.5K point
Maximum USBflash drive size
64 GB
Waveformstorage withUSB flash drive
96 or more reference waveforms per 8 MB
Setups withoutUSB flash drive
10 front-panel setups
Setups with USBflash drive
4000 or more front-panel setups per 8 MB
Screen imageswith USB flashdrive
128 or more screen images per 8 MB (the number ofimages depends on file format selected)
Save All withUSB flash drive
12 or more Save All operations per 8 MBA single Save All operation creates 3 to 9 files (setup, image,
plus one file for each displayed waveform)*2 Bandwidth is 20 MHz at 2 mV/div, all models.
Acquisition ModesMode DescriptionPeak Detect High-frequency and random-glitch capture. Captures
glitches as narrow as 12 ns (typical) at all time basesettings from 5 μs/div to 50 s/div
Sample Sample data onlyAverage Waveform averaged, selectable: 4, 16, 64, 128Single Sequence Use the Single Sequence button to capture a single
triggered acquisition sequenceRoll At acquisition time base settings of >100 ms/div
Trigger SystemCharacteristic DescriptionTrigger Modes Auto, Normal, Single Sequence
Trigger TypesTrigger DescriptionEdge (Rising/Falling) Conventional level-driven trigger. Positive or negative
slope on any channel. Coupling selections: AC, DC,Noise Reject, HF Reject, LF Reject
Video Trigger on all lines or individual lines, odd/even or allfields from composite video, or broadcast standards(NTSC, PAL, SECAM)
Pulse Width (or Glitch) Trigger on a pulse width less than, greater than, equalto, or not equal to, a selectable time limit ranging from33 ns to 10 s
Trigger SourceCH1, CH2, Ext, Ext/5, AC Line.
Trigger ViewDisplays trigger signal while Trigger View button is depressed.
Trigger Signal Frequency ReadoutProvides a frequency readout of the trigger source.
CursorsCharacteristic DescriptionTypes Amplitude, TimeMeasurements ΔT, 1/ΔT, ΔV
Automatic WaveformMeasurementsPeriod, Frequency, +Width, –Width, Rise Time, Fall Time, Max, Min,Peak-to-Peak, Mean, RMS, Cycle RMS.
Waveform MathCharacteristic DescriptionOperators Add, Subtract, Multiply, FFTFFT Windows: Hanning, Flat Top, Rectangular;
2048 sample pointsSources CH1 – CH2, CH2 – CH1, CH1 + CH2, CH1 × CH2
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176TestEquipmentDepot.com
Data Sheet
Autoset MenuSingle-button, automatic setup of all channels for vertical, horizontal, and triggersystems, with undo Autoset.Signal Type Autoset Menu ChoicesSquare Wave Single Cycle, Multicycle, Rising or Falling EdgeSine Wave Single Cycle, Multicycle, FFT SpectrumVideo (NTSC, PAL,SECAM)
Field: All, Odd, or EvenLine: All or Selectable Line Number
AutorangeAutomatically adjust vertical and/or horizontal oscilloscope settings whenprobe is moved from point to point, or when the signal exhibits large changes.
Display CharacteristicsCharacteristic DescriptionDisplay ¼ VGA backlit passive LCD with adjustable multilevel
contrast and inverse video selectable from front panelInterpolation Sin (x)/xDisplay Types Dots, vectorsPersistence Off, 1 s, 2 s, 5 s, infiniteFormat YT and XY
Multiple-language User Interface and Context-sensitive HelpCharacteristic Description
LanguagesAvailable
English, French, German, Italian, Japanese,Korean, Portuguese, Russian*3, Simplified Chinese,Spanish, Traditional Chinese
*3 Requires Russian firmware, indicated by "RUS" suffix.
Environmental and SafetyCharacteristic DescriptionTemperature
Operating 0 to +50 ºCNonoperating –40 to +71 ºC
HumidityOperating andNonoperating
Up to 80% RH at or below +40 ºC
Operating andNonoperating
Up to 45% RH up to +50 ºC
AltitudeOperating andNonoperating
Up to 3,000 m
ElectromagneticCompatibility
Meets Directive 2004/108/EC, EN 61326-2-1 Class A;Australian EMC Framework
Safety UL61010-1:2004, CSA22.2 No. 61010-1:2004,EN61010-1:2001, IEC61010-1:2001
Physical CharacteristicsInstrumentDimensions mm in.Width 326.3 12.85Height 158.0 6.22Depth 124.2 4.89Weight kg lb.Instrument Only 2.0 4.4
With accessories 2.2 4.9Instrument ShippingPackage Dimensions mm in.Width 476.2 18.75Height 266.7 10.5Depth 228.6 9.0RM2000B Rackmount mm in.Width 482.6 19.0Height 177.8 7.0Depth 108.0 4.25
Digital Storage Oscilloscopes — TDS1000B Series
Ordering Information
ModelsModel DescriptionTDS1001B 40 MHz, 2 Ch, 500 MS/s, Monochrome DSOTDS1002B 60 MHz, 2 Ch, 1 GS/s, Monochrome DSOTDS1012B 100 MHz, 2 Ch, 1 GS/s, Monochrome DSO
Standard AccessoriesAccessory DescriptionPassive Probes 200 MHz (one per channel)Power Cord (Please specify plug option)NIM/NIST Traceable Certificate of CalibrationDocumentation User manual (please specify preferred language option)OpenChoice PCCommunicationsSoftware
Enables fast and easy communication between aWindows PC and the TDS1000B Series using USB.Transfer and save settings, waveforms, measurements,and screen images
National InstrumentsSignalExpress TektronixEdition InteractiveMeasurement Software– Base Version
A fully interactive measurement software environmentoptimized for the TDS1000B Series. Enables you toinstantly acquire, generate, analyze, compare, import,and save measurement data and signals using intuitivedrag-and-drop user interface that does not require anyprogramming. Standard TDS1000B Series support foracquiring, controlling, viewing, and exporting your livesignal. A 30-day trial period of the Professional Versionprovides additional signal processing, advance analysis,mixed signal, sweeping, limit testing, and user-definedstep capabilities. Order SIGEXPTE for permanentProfessional Version capability
Limited LifetimeWarranty*4
Covers labor and parts for defects in materials andworkmanship for a minimum of 10 years, excludingprobes and accessories*5
*4 Lifetime is defined as 5 years after Tektronix discontinues manufacturing the product, but thewarranty length shall be at least 10 years from date of original purchase. Lifetime warranty isnontransferable, proof of original purchase is required. Limitations apply. For terms and conditions visitwww.tektronix.com/lifetimewarranty.
*5 Probes and accessories are not covered by the oscilloscope warranty and service offerings. Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms.
Power Plug OptionsOption DescriptionA0 North America powerA1 Universal Euro powerA2 United Kingdom powerA3 Australia powerA5 Switzerland powerA6 Japan powerA10 China powerA11 India powerA99 No power cord or AC adapter
User Manual OptionsTranslated front-panel overlays included with their respective user manuals.Option DescriptionL0 English manualL1 French manualL2 Italian manualL3 German manualL4 Spanish manualL5 Japanese manualL6 Portuguese manualL7 Simple Chinese manualL8 Standard Chinese manualL9 Korean manualL10 Russian manual
Recommended AccessoriesAccessory DescriptionTEK-USB-488 GPIB-to-USB ConverterSIGEXPTE National Instruments SignalExpress Tektronix Edition
Interactive Measurement Software – ProfessionalVersion
AC2100 Soft Carrying Case for instrumentHCTEK4321 Hard Plastic Carrying Case for instrument
(requires AC2100)RM2000B Rackmount Kit071-1075-xx Programmer’s Manual – English Only071-1828-xx Service Manual – English Only174-4401-xx USB Host-to-Device Cable, 3 ft. long
Recommended ProbesProbe DescriptionP2220 10X to 1X Switchable Passive probe (200 MHz when
10X is selected)P6101B 1X Passive probe (15 MHz, 300 VRMS CAT II rating)P6015A 1000X High-voltage Passive probe (75 MHz)P5100 100X High-voltage Passive probe (250 MHz)P5200 High-voltage Active Differential probe (25 MHz)P6021 15 A, 60 MHz AC Current probeP6022 6 A, 120 MHz AC Current probeA621 2000 A, 5 to 50 kHz AC Current probeA622 100 A, 100 kHz AC/DC Current probe/BNCTCP303/TCPA300 150 A, 15 MHz AC/DC Current probe/amplifierTCP305/TCPA300 50 A, 50 MHz AC/DC Current probe/amplifierTCP312/TCPA300 30 A, 100 MHz AC/DC Current probe/amplifierTCP404XL/TCPA400 500 A, 2 MHz AC/DC Current probe/amplifier
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176TestEquipmentDepot.com
Data Sheet
Service Options*5Option DescriptionC3 Calibration Service 3 YearsC5 Calibration Service 5 YearsD1 Calibration Data ReportD3 Calibration Data Report 3 Years (with Option C3)D5 Calibration Data Report 5 Years (with Option C5)CA1 Provides a single calibration event or coverage for the
designated calibration interval, whichever comes first*5 Probes and accessories are not covered by the oscilloscope warranty and service offerings. Refer to the data
sheet of each probe and accessory model for its unique warranty and calibration terms.
Service Offerings (Available after purchase)Option DescriptionTDSxxxxB-CA1 Provides a single calibration event or coverage for the
designated calibration interval, whichever comes first
The Complete Measurement SolutionThe AFG3000 Series arbitrary function generator pairs with the TDS1000B Seriesdigital storage oscilloscopes to deliver the two elements of a complete measurementsolution – stimulus and acquisition. This instrument combines the capabilities of afunction generator with the power of an arbitrary waveform generator, offering theperformance needed to accurately verify, validate, and characterize designs withease and confidence at a price you can afford.
The Tektronix Customer Service AdvantageYou can trust Tektronix to offer unequalled engineering expertise and acustomer-centric approach to ensure the optimal performance of your Tektronixproducts and maximize the lifetime value of your Tektronix investment. With servicefrom Tektronix you get:
Access to the source of product knowledge; unsurpassed technicalexpertise
Your challenges solved by front-line technical experts, designengineering reinforcement, and online support tools
Comprehensive and thorough support provided worldwide, includingsoftware and firmware updates, data reports, and adjustments
Efficiency and convenience; no-hassle service from initial service callto turnaround and delivery
Flexible repair and calibration service with access to the best on-calltechnical troubleshooting staff in the industry, with over 20 years oftraining per support engineer
Customer-centric approach dedicated to serving your needs everydaywith services designed to optimize your product performance, increaseproductivity and ROI by delivering a fixed cost of ownership, and efficientmanagement of service
Get checked by Tektronix. Visit www.tektronix.com/serviceandsupport.
Product(s) are manufactured in ISO registered facilities.
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with TektronixStandard Codes and Formats.
6 www.tektronix.com