2
2
3
1
The Sterile Goods Cycle
Disinfecting and cleaning
Provision and treatment
Clearing away and disposal
Think Competence. Think Aesculap.Systematic InstrumentReprocessing Procedure:
All hygienic measures in the dental practiceare primarily for keeping healthy thepatients, the dentist and the assistants.
To ensure the best possible safety it isparticularly important to observe theprinciples of hygiene when reprocessinginstruments.
To keep practice work safe, efficient andeconomical, clear procedures must bespecified for practice hygiene.
The Aesculap Sterile Container System has proven itself as an excellent aid for organizing the instrument reprocessing procedure.
3
4
5
6
Storage
Inspection and packing
Sterilizing
Four good reasons to choosethe Sterile Container System:
� Safetyfor patients and staff through preservation of instrument sterility and closed transport of used instruments
� EconomicEconomic advantages due to reusable packaging, low costs of use and long service life
� Comfortable handlingsimple, quick and safe
� Transparencystandardised easy documentation of the supply cycle
Economy and Safety over the entire system lifespan
In contrast to single-use packaging, sterilecontainers are capital assets offering along service life. We think that the one-time procurement costs for the sterilecontainers will be amortized many timesover in the course of their long servicelife, which makes them more economicalthan single-use packaging, due to thefollowing factors:
� No recurring costs for packaging materials
� Reduction/elimination of disposal costs for single-use materials
� Time savings when loading the trays
� Time savings at the sterilization stage
� Reduced incidence of resterilization necessitated by damaged packaging, thanks to the robust packaging of the sterile materials
� Faster sterile setup
� Easy transport through the sterile supply cycle
� Long service life of sterile containers
Furthermore, waste and environmentalpollution caused by disposable packagingis avoided.
4
The Aesculap Sterile Container System
Think Economy. Think Aesculap.
The containers are made from light metal(aluminium alloy), which offers the bestdrying results and reduces their weight.
The lid and base of the containers are perforated for steam sterilization usingthe gravitational method and the fractionated vacuum method (the filtermaterial makes them unsuitable for hotair sterilization).
Aesculap sterile containers comply withthe requirements of DIN EN ISO 11607,part 1.
5
Aesculap sterile filters are
� safe: the filter material conforms to the requirements of DIN EN ISO 11607, part 1
� reliable: easy to check
� advantageous: they facilitate good drying results within the container
The Aesculap PTFE permanent filter alsocontributes to efficiency and economywith the following features:
� extremely resistant and durable
� validated for 1,000 use cycles
6
The Aesculap Sterile Container System
The lock plates can be fixed at any position and turned through 180° into the lid. Springs integrated into the lockplates guarantee that the sterile containeralways remains consistently closed.
The seal prevents accidental opening ofthe container after sterilisation.
The containers can be stacked, reducingthe amount of space required in thesterile goods cycle.
Think Quality. Think Aesculap.
Quality at a glance
The tension locks are also designed ashandles for fast, contamination-free lidremoval when sterile goods are presentedfor use.
7
The filter holder has an extremely durablesilicon seal which keeps the filter firmly inplace:
� reliable� safe� germ-tight
Closure of the dental containers is ensured by the ring-shaped silicon sealsaround the inside of the lid.
Perfect OrganizationYour instruments are stored in thesmallest possible space, safely fixed intheir positions.
8
The Aesculap Tray System
Think Innovation. Think Aesculap.
Safe and effective
The wide perforation ensures optimalwater jet permeation and avoids rinsingblind spots.
Practical and economical
Mechanical processing with the Aesculaptray system optimizes your workflow. Thestainless steel material makes Aesculaptrays a robust and durable asset. The simple and robust locking system can beeasily opened and closed with one hand.
Flexible and adaptablePosition the silicone racks in the optimalarrangement for your instruments – in seconds, without any additional tools.
9
10
The Aesculap Sterile Container System
JN092
Outside dimensions
312 x 190 x 46 mm
To take following trays: 1 x JG381R or 1 x JG383R or 1 x JG389R
JN086 container body and JN091 lid canalso be ordered singly
JN094
Outside dimensions
312 x 190 x 65 mm
To take following trays: 2 x JG380R or 1 x JG384R or 1 x JG386R
JN088 container body and JN091 lid canalso be ordered singly
JN095
Outside dimensions
312 x 190 x 92 mm
To take following trays: 2 x JG381R or 1 x JG381R + 1 x JG384RJN089 conainer body and JN091lid can also be ordered singly
JN096
Outside dimensions
312 x 190 x 130 mm
To take all trays or 1 x JF282R basketwith lid JF289RJN090 container body and JN091 lidcan also be ordered singly
Container with lid and baseperforation
Cont
aine
r
11
JK091
Outside dimensions
94 x 215 mm
JK092
Outside dimensions
170 x 231 mm
JF166
Outside dimensions
118 x 235 mm
JF066
Outside dimensions
171 x 232 mm
Aesculap reusable filter for dentalcontainers JN092-JN096 with narrowperforation, service life 1,000 cleaningand sterilization cyclesSuitable for containers on page 10
Order unit (PAK): Pack of 2
Aesculap reusable filter for dentalcontainers JN092-JN096 with wide per-foration, service life 1,000 cleaning andsterilization cyclesSuitable for the former generation
Order unit (PAK): Pack of 2
Aesculap paper filter with with sterilization status indicator, for dentalcontainers JN092-JN096 with narrow perforationSuitable for containers on page 10
Order unit (PAK): Pack of 100
Aesculap paper filter with sterilization status indicator for dental containersJN092-JN096 with wide perforationSuitable for the former generation
Order unit (PAK): Pack of 100
Filter
Accessories
Cont
aine
r
Acce
ssor
ies
12
JG645U
JG646U
JG647U
JG648U
JG650U
JG652U
JG653U
JG654U
JG645B
JG646B
JG647B
JG648B
JG650B
JG652B
JG653B
JG654B
red
blue
green
gold
black
olive
purple
orange
with inscriptionup to 13 letters
blanc
Identification labels made of aluminium, 50 x 18 mm
Accessories
Plastic identification labels, ochre,with 10-character barcode for soft-ware applications praxiDoc or DIOS, labelling as specification
ICD-002
Outside dimensions
56 x 18 mm
Identification label
Acce
ssor
ies
13
Marking pen
Indicator label
Marking pen for Aesculap reusable filters
Order unit (PAK): Pack of 3JK086
Indicator label with adhesive back andsterili-zation status indicator for steam sterilization
Order unit (PAK): Pack of 100
JG687
Außenmaß
60 x 18 mm
JG738
Eloxal cleaner for cleaning and care ofcontainer surfaces
Contents: 300 ml
JG601
Seal
Maintenance products
Seal - safeguarding the container against unauthorized opening
Order unit (PAK): Pack of 100
Tray
s
14
The Aesculap Tray System
Dental Trays
JG380R
Outside dimensions
273 x 84 x 41 mm (high)
Tray, contains three instrument racks(JG392)Suitable for dental container JN094
JG381R
Outside dimensions
273 x 176 x 30 mm (flat)
JG383R
Outside dimensions
273 x 176 x 30 mm (flat)
JG384R
Outside dimensions
273 x 176 x 41 mm (high)
Tray, contains three instrument racks (3 x JG391)Suitable for dental container JN092
Tray, with perforation for retractor, con-tains three instrument racks (3 x JG391)Suitable for dental container JN092
Tray, contains three instrument racks(3 x JG393)Suitable for dental container JN094
Tray
s
15
Dental Trays
JG387R
Outside dimensions
188 x 84 x 30 mm (flat)
JG388R
Outside dimensions
188 x 125 x 30 mm(flat)
JG389R
Outside dimensions
273 x 176 x 30 mm (flat)
Tray, contains two instrument racks(JG394) for 6 instruments
Tray, contains two instrument racks(JG395) for 10 instruments
Tray, contains five instrument racks (2 x JG394, 2 x JG400, 1 x JG401)Suitable for dental container JN092
JG386R
Outside dimensions
273 x 176 x 41 mm (high)
TraySuitable for dental container JN094
Acce
ssor
ies
16
Accessories
for trays JG 381R-JG384Rfor tray JG389R
Silicone press pad, for suppressing theinstrument, to assemble to the lowerside of the lid
JG400
Outside dimensions
158 x 14 mm
JG394
Outside dimensions
74 x 22 mm
JG395
Outside dimensions
115 x 22 mm
JG391
Outside dimensions
158 x 22 mm
JG392JG393
Outside dimensions
76 x 33 mm158 x 33 mm
JG390
Outside dimensions
158 x 30 mm
JG399JG401
Outside dimensions
150 x 15 mm158 x 11.5 mm
Silicone instrument racks for trays with 30 mm height
Silicone instrument racks for trays with 41 mm height
Acce
ssor
ies
17
JG396
Outside dimensions
76 x 33 mm
Silicone instrument racks
Silicone bar with metal brackets, Fitting in tray JF234R
JG397
Outside dimensions
160 x 23 mm
Silicone bar with metal base plateand holding pins JG300Fitting in tray JF237R
JG398
Outside dimensions
160 x 34 mm
Silicone bar with metal base plateand holding pins JG300Fitting in tray JF264R
JG300
Outside dimensions
160 x 34 mm
Holding pin for silicone bars JG397 - JG398
Order unit (PAK): Pack of 10
JG625R
Outside dimensions
160 x 34 mm
Holding device for identification labels
JG701R
Outside dimensions
55 x 25 x 20 mm
Rack for 8 drills, assembling anddiassembling without tools
Tray
s
18
Further Trays
JF264R
Outside dimensions
273 x 176 x 41 mm
JF282R
Outside dimensions
269 x 171 x 93 mm
JF289R
Outside dimensions
273 x 176 x 16 mm
JF148R
Outside dimensions
144 x 44 x 25 mm
Tray with lid handle; no insert, fordental container JN094
Basket without lid, for dentalcontainer JN096
Lid for tray JF282R
Mini tray for small objects
Dental Trays
Acce
ssor
ies
19
Maintenance of Instruments
Reprocessing of instruments in dentalpractice, brochure for download fromhttp://www.a-k-i.org
Detailed information about theInstrument-Management-SoftwarepraxiDoc are available in our brochureD11801.
JG598
Aesculap instrument oil, for box locks,ratchets etc. prior to sterilization. Sterilit® carries the CE label and fulfils the fundamental requirementsin compliance with MDD93/42/EEC.
JG600
Aesculap oil spray, in aerosol can (ozone-friendly), for maintenance of instruments prior to sterilization. Sterilit®carries the CE label and fulfils the fundamental requirements in compliancewith MDD93/42/EEC. Inclusive 2 nozzles.
Brochure No. D05802
All rights reserved. Technical alterations are possible. This leaflet may be used for no other purposes than offering, buying and selling of our products. No part may be copied or reproduced in any form. In the case of misuse we retain the rights to recall our catalogues and pricelists and to take legal actions.
Aesculap AG
Am Aesculap-Platz78532 TuttlingenGermany
Phone +49 7461 95-0Fax +49 7461 95-2600
www.aesculap.de
0808/2.0/1
Top Related