Introduction
In the past, the stress analysis of orthodonticforces and alveolar bone has been studied mainlyon models in which the bony structures havebeen replaced by wax and elastic materials.These materials do not have the characteristicsof the bony structure itself. The structure ofthese materials is totally different from bone andcan be considered as homogenous. An equallayer of wax is melted around plastic or metal
teeth in typodont set-ups, and the same holdstrue for elastic models in which the bonystructures are replaced by elastic materials(Caputo et al., 1974; Baeten, 1975; Brodsky et al.,1975; Gambrell and Allen, 1975; Chaconas et al.,1976). Depending upon their location in thearches, teeth might be surrounded by variousamounts of cancellous and cortical bone,resulting in a different resistance to appliedforce systems. Moreover, adjacent teeth and
surrounding bones may also influence theresistance. When applying orthopaedic forces tothe nasomaxillary complex, it is of importanceto analyse the effects upon the craniofacialskeleton and the dentition. Therefore, interestin biomechanics has resulted in a number ofanalytical and experimental investigations(Kragt et al., 1979, 1982, 1986; Dermaut andBeerden, 1981; Kragt and Duterloo, 1982,Kusy and Tulloch, 1986). The main purpose ofthat research was to study the overall effects
of various extra-oral traction appliances andthe resistance of the environment to the appliedforces. To understand the mechanical propertiesof these appliances, the relationship of the forcevector to the centre of resistance (Cre) of thenasomaxillary complex and the dentition has tobe considered. In former studies, model systemshave been used to determine the location of theCre of a tooth or a group of teeth (Burstoneet al., 1981; Dermaut and Vanden Bulcke, 1986;
European Journal of Orthodontics 23 (2001) 263273 2001 European Orthodontic Society
Location of the centre of resistance of the upper dentition
and the nasomaxillary complex. An experimental study
Toon Billiet, Guy de Pauw and Luc DermautDepartment of Orthodontics, University of Gent, Belgium
SUMMARY The purpose of this study was to investigate the initial displacement of the upperdentition and the nasomaxillary complex as a result of different directions of force application,and to determine the initial centres of resistance for both the upper dentition and thenasomaxillary complex.
A macerated human skull with a well-aligned upper arch was used as one experimentalmodel and Araldit 208 as a substitute for the periodontal ligament (PDL). Specificallydesigned antenna-headgear was developed in an attempt to create different points of forceapplication to simulate high-pull and horizontal traction, and orthopaedic force magnitudesof 8 N were applied to the upper dentition and the nasomaxillary complex. Double exposureholography was used to measure the initial displacement. Reproducibility of the techniquewas tested and found to be reliable.
According to the registered fringe patterns, the force application transmitted by the headgearresulted in complex displacement of facial bones. Pure translation of the maxilla and theupper dentition was observed when the force vector passed by in the area of the key-ridge.No obvious difference was found between the centre of resistance of the upper dentitionand the nasomaxillary complex. The location of two different centres of resistance couldnot be confirmed by measuring initial displacements on this macerated human skull.
8/13/2019 2001 billiet
2/12
Dermaut et al., 1986a,b; Vanden Bulcke et al.,1987). These investigations provided insight intothe displacement characteristics of the dentitionto applied forces. In particular, the point of forceapplication was found to be an important factor
in tooth displacement. The location of the Creof the maxillary complex offers importantinformation with respect to the use of headgear-activators. Differences in the direction oforthopaedic forces, as well as the point of forceapplication may produce different displacementpatterns of the complex and stress distribution inthe maxillofacial sutures of the nasomaxillarycomplex. Kragt et al. (1982, 1986), Tanne et al.(1993), and Tanne and Matsubara (1996) reporteda difference in force distribution after application
of various force systems. These findings can beexplained by the differences in the locationand direction of force vectors relative to theCre of the nasomaxillary complex. According tothe literature, there is little evidence concerningthe location of the Cre. The experimentaldetermination of the Cre of the upper first molarand of the anterior teeth has already beencarried out (Dermaut et al., 1986a,b; Dermautand Vanden Bulcke, 1986; Vanden Bulcke et al.,1987). Teuscher (1986), and Stckli and Teuscher(1994) made a distinction between the Cre of the
upper dentition and of the maxilla. They definedthe Cre of the maxilla at the postero-superiorarea of the zygomaticomaxillary suture, whereasthe Cre of the upper dentition was situatedbetween the roots of the upper premolars. Thelocation of these points was determined byobserved changes in craniofacial morphologyevaluated on lateral cephalograms of differentpatients treated with an activator. The definedcentres of resistance have to be understood asaverage points. Moreover, the effect of normal
growth, which may differ from patient to patient,might also affect the position of these points.Initial stress analysis induced by headgear-activator therapy, might be investigated on askull by changing the point and direction of forceapplication. Initial displacement is the result ofthe resistance of the nasomaxillary complex todifferent force application systems in which thebiological parameters are left constant by usingthe same skull. Besides Teuscher (1986) and
Stckli and Teuscher (1994) a few other clinicalstudies have offered information on the local-ization of the Cre of the nasomaxillary complex.
Over the years, there has been an increasedinterest in studies in which extraoral traction has
been tested on different human skulls models.Strain gauges, photo-elastic models and finiteelement analysis are often used as measuringmethods (Caputo et al., 1974; Hata et al., 1987;Tanne et al., 1993). In a finite element study,Tanne et al. (1995) suggested that the Cre ofthe nasomaxillary complex was located on thepostero-superior ridge of the pterygomaxillaryfissure. Lee et al. (1997) concluded, in a laserholography study on a human dry skull, thata translation was reached when the point of
anterior force application was 15 mm above anddirected 20 degrees downwards to the occlusalplane along with palatal expansion.
The aim of this study was to investigate theinitial displacement of the upper dentition andthe nasomaxillary complex as a result of differ-ent directions of force, and to determine theinitial centres of resistance for both the upperdentition and the nasomaxillary complex.
In the present investigation a non-invasiveand highly accurate holographic method wasused which allowed the precise detection of
very subtle initial reactions of hard tissue afterforce application. From a clinical viewpoint,exact information on the possible effects offorce application is of outmost importance forthe orthodontist, since initial displacement maybe indicative.
Materials and methods
A macerated human skull (aged 16 years), withwell-aligned upper permanent teeth, was used as
the experimental model. The teeth were carefullyremoved from the skull and their bony socketscleaned with acetone to remove residue. Duringthis procedure an attempt was made to avoid anydamage to the alveolar bone. Only one skull wasused so that all biological and environmentalvariables were left constant except those tobe investigated. Since all parameters remainedunchanged, the only differences which weremeasured, were due to the differences in force
264 T. BILLIET ET AL.
8/13/2019 2001 billiet
3/12
direction. The periodontal ligament (PDL) wasreplaced by a thin layer of resin (Araldit 208,CM Technics) injected into the empty sockets,following which the teeth were carefully
repositioned. This special resin, when mixed withthe harder 956 (CM Technics) at a ratio of 10to 1, displays nearly the same elastic propertiesas the human periodontium (Dijkman, 1969).In the present study, an artificial PDL was usedin an attempt to simulate more accurately thebiological situation. Although the elastic modulusof Araldit is not provided by the manufacturers,laboratory experiments have shown forces of60 kg/cm2, which is comparable to the valuesdescribed by Diemer and Hofmann (Dijkman,
1969). Orthodontic molar bands carryingheadgear tubes were cemented on the maxillaryfirst permanent molars and an identical tubewas glued directly to the maxillary bone. Anacrylic splint was fabricated to embrace theupper dentition and a rigid metal plate was fixedto the anterior part of the splint, in an attempt toregister accurately initial displacement by meansof holography (Figures 1 and 2). With a metalplate, an extension was made of the dentition.
For the same rotation it was obvious that thefurther away from the clasping point (point offixation), the larger the number of fringes. Themetal plate enabled improved visualization of
the differences between the various points offorce application. Two facebows, which alloweddifferent points of force application, were con-structed. In a first series of experiments a facebowwas used to register horizontal traction atdifferent vertical levels (Figure 3). For verticaltraction a second facebow was constructed toapply vertical forces on different sagittal positions(Figure 4). These last measurements were carriedout in a second experiment. Different hookswere soldered at various levels of the bows to
support a nylon wire and to create various pointsof force application.
The skull was fixed to a heavy metal support bya modelling compound shield covering the frontaland occipital bone. Traction was transmitted tothe hooks by means of a nylon wire attached toa weight carrier dish via wheels that could beadjusted to simulate high-pull and horizontaltraction. A force magnitude of 8 N was producedby placing a dish weight on the carrier.
CENTRE OF RESISTANCE AND UPPER DENTITION 265
Figure 1 Experimental set-up with antenna headgear, splint and metal plate; example of high-pulltraction to the dentition.
8/13/2019 2001 billiet
4/12
In recent years, holography has been increas-ingly used in biomechanical research, especiallyin orthodontics. In this procedure, coherent
and monochromatic laser light is employed forrecording an object surface on a photosensitiveemulsion of the holographic plate. This plate isilluminated by a split laser beam; one beam (the
reference) is directed towards the holographicplate and the other reflected from the objectsurface. By superimposition of two coherentlight waves, one of which is reflected from theundeformed and the other from the deformedobject surface, spatial interference fields areformed by interference of these waves. In theplane of the hologram these fields are reducedto a system of interference fringes. This fringepattern yields information concerning themagnitude of the displacement at the surface
of the object and the direction of displacement.A 10 mW He-Ne laser ( = 0.6328 m) was usedand the laser beams were exposed on holographicplates (Agfa Gevaert) consisting of a highlysensitized emulsion that coated the glass plates.A double exposure technique was used. Theunloaded skull was exposed for 10 seconds, thedesired force was then applied for 10 minutesand the same holographic plate was thenexposed for a further 10 seconds. A relaxation
266 T. BILLIET ET AL.
Figure 2 Example of horizontal traction to the maxilla.
Figure 3 Points of force application (17) to the maxillaand the dentition with horizontal traction.
8/13/2019 2001 billiet
5/12
period of 15 minutes was allowed before the nexthologram was taken. A frontal hologram wastaken for each traction: seven points of forceapplication for the high-pull traction and sevenpoints for the horizontal traction. To test the
reliability of the method, five holograms fromsix different force systems were taken followingloading of 6 N. A minimal amount of force wasneeded to visualize the creation of fringes. Tomeasure displacements in a reproducible way, itwas found that a minimum force of 6 N wasneeded. In the final experiment, this force wasincreased to 8 N in an attempt to improve thevisualization of the amount and direction of thefringes.
Results
Reliability of the method
Since the quantitative calculation of the initialdisplacement of the upper dentition and thenasomaxillary complex uses the counting offringes with regard to a chosen reference point,the accuracy depends upon the visibility andoutline of the dark fringes. The fixation of theskull was tested under different loading andproved to be reliable. A series of five holograms
registering the application of an orthopaedicforce of 6 N under six different loading systems
showed a highly comparable fringe pattern. Thetotal amount of fringes over the whole lengthof the skull differed by a maximum of one unit(Table 1).
The analysis of the fringe patterns on the
maxillary complex and the upper dentition incase of high-pull and horizontal traction revealedthe following findings.
High-pull traction (Figure 4). A force applicationanterior to the key-ridge always created an initialcounterclockwise rotation of the dentition and ofthe maxillary complex indicated by the numberof fringes (Figure 5). Within one maxillofacialbone the fringe patterns showed regular images.In the sutures between the bones this regularpattern was interrupted, indicating that the
sutures transmitted orthopaedic forces resultingin differential displacement directions. When theforce vector approximated the presumed Cre,the magnitude of the rotational displacement wasless although a force direction through the Creshould create a translation. A force applicationposterior to the Cre again created a higher numberof fringes, indicating a clockwise rotation. Thedifference of the point of force applicationbetween the dental splint and the maxilla did notseem to be of great importance when comparingthe magnitudes of the initial displacement
(Figure 6). The rigid fixation of the dentitionby the maxillary splint seemed to transmit the
CENTRE OF RESISTANCE AND UPPER DENTITION 267
Table 1 Error of the method tested by comparing the magnitude of the initialdisplacement (106m) in 5 holograms (n = 5) taken from the same situation on3 randomly selected different points of force application (P1 P3).
x= mean displacement, r= range
8/13/2019 2001 billiet
6/12
268 T. BILLIET ET AL.
Figure 5 Example of a series of seven holograms illustrating the initial displacement of the nasomaxillarycomplex with high-pull traction on the dentition.
Figure 4 Points of force application (17) to the dentition and the maxilla withhigh-pull traction.
8/13/2019 2001 billiet
7/12
applied forces directly to the maxilla without asignificant difference in initial displacement ofthe dentition.
Horizontal traction (Figure 3). The initialorthopaedic displacement of the maxilla afterhorizontal force application was comparablewith the displacement after high-pull traction asfar as the magnitude of the displacement wasconcerned.
A force application beneath the zygomaticprocess of the maxilla created a clockwiserotation of the maxilla, while a force applicationabove the zygomatic process resulted in acounter-clockwise rotation of the maxilla. The
smallest rotation was observed with a forcedirection just below the zygomatic process ofthe maxilla (Figure 7).
A typical circular fringe pattern as describedby Lee et al. (1997) was observed at the key-ridgeof the maxilla with high-pull, as well ashorizontal traction at different points of forceapplication (Figure 8). These circular fringeswere the result of a lateral translation of thecentre of the zygomatic arch.
By combining the force levels of horizontaland high-pull traction with the least fringes, theCre was constructed (Figure 9). Translation was
considered to occur in this experimental set-upwhere the least fringes were registered. Both theCre defined by forces applied to the splintedteeth and to the maxilla were located near thelower border of the zygomatic process of themaxilla. There were no significant differencesbetween the initial displacement of the upperdentition and the maxillary complex. Themagnitude as well as the direction of the initialdisplacement was comparable. The analysis of thefringe pattern could not distinguish a difference
between a dental and a skeletal Cre.
Discussion
The use of a macerated human skull as a modelto investigate the effect of force applicationon teeth and bone deals with the followinghypothesis: by applying a force on a tooth, thePDL is stretched on one side and squeezed onthe other. Bone apposition by the formation of
CENTRE OF RESISTANCE AND UPPER DENTITION 269
Figure 6 Diagram illustrating the magnitude of displacement for different points of forceapplication with high-pull traction on the dentition and the maxilla (CCW = counter-clockwiserotation; CW = clockwise rotation).
8/13/2019 2001 billiet
8/12
bone spiculae and bone resorption on theopposite side might be the result. This biologicalphenomenon creates tooth movement andrebuilding of the alveolar process. Initial dis-placement registered on the skull might provide
270 T. BILLIET ET AL.
Figure 8 Typical circular fringe pattern observed atdifferent force levels at the zygomatic area.
Figure 9 The Cre defined by the intersection of the actionlines after horizontal (HT) and high-pull (HPT) forceapplication inducing translation of the maxilla.
Figure 7 Diagram illustrating the magnitude of displacement for different points of forceapplication with horizontal traction on the dentition and the maxilla (CW = clockwiserotation; CCW = counter-clockwise rotation).
8/13/2019 2001 billiet
9/12
an indication for the expected longitudinaleffect.
The influence of force application on thecraniofacial complex has been investigatedextensively in clinical and in vitro situations. It is
difficult to study the effect of the different forceparameters in the clinical situation. Therefore, inthe last decades, an attempt has been made toinvestigate the influence of orthopaedic forceson different in vitro models. In the present study,a macerated human skull was used to evaluatethe initial orthopaedic displacements of themaxilla and the upper dentition in a posteriordirection. The complex architecture of the skullwith combinations of trabecular and corticalbone, as well as sutures and teeth together with
changes in elasticity of all these structures, makethe dry skull a more valuable model than thoseconstructed by using photoelastic materials.Nevertheless, the absence of soft tissues in thesutures, and of the PDL, the macerating process,humidity and other factors may have consequencesin the biomechanical behaviour.
To approximate reality, Araldit was usedas a substitute for the PDL (Dijkman, 1969).
In previous studies the initial displacement ofteeth on a dry skull by headgear (Dermaut et al.,1986a,b) and by intrusive mechanics (Dermaut
and Vanden Bulcke, 1986) was found to becomparable to the clinical displacement (Wormset al., 1973; Nanda, 1981), indicating that theuse of a macerated skull might be a valuablemodel. The centre of rotation might be definedby the intersection of two displacement vectors(De Clerck et al., 1990; Govaert and Dermaut,1997). However, a recent study (De Pauw andDermaut, 1998), clearly showed that the useof the centre of rotation is susceptible to animportant error. Small differences in the direc-
tion of the displacement vectors may resultin a considerable change of the centre ofrotation. Therefore, in this study initial displace-ment vectors were used instead of centres ofrotation.
The magnitude and the direction of the initialdisplacement vector immediately after forceapplication will indicate the differential reactionsof the bones as a result of the force system used.A force application through the Cre of the
maxilla will create a pure translation, so anexact definition of the position of the Cre ofthe maxilla is important in order to obtainthe presumed maxillary displacement. Poulton(1959, 1967), Barton (1972), and Bench et al.
(1978) defined different displacements of themaxilla after headgear force application onpatients. According to Poulton (1959, 1967) theCre of the maxilla is situated at the apex of thesecond premolar in the maxilla. Bench et al.(1978) reported its position to be in the mostsuperior point of the fossa sphenopalatina, whileBarton (1972) linked the position of the Creof the maxilla to the number of teeth involved inthe appliance design. They all applied headgeartherapy to the upper first molars in different
patients. In the present experimental set-upheadgear traction was applied to a splint anddirectly to the maxilla in the same skull. Accordingto earlier experiments using laser measuringtechniques (Dermaut and Beerden, 1981; Dermautand Vanden Bulcke, 1986; Dermaut et al.,1986a,b) it has been found that bone displace-ments within a skull, after force application, aredue to displacements in the sutures, rather thanto bone bending within the same bone unit. Forpractical reasons tubes were glued on thealveolar process in the area of the first molars.
This location is not critical as the localisation ofthe Cre of the maxilla is determined by the pointof force application (facebow hooks) instead ofthe position of the tube. It is obvious thereforethat comparison of the findings is inappropriate.
Lee et al. (1997) in a comparable dryskull study applied anterior traction to a rapidmaxillary expansion appliance in an attempt totransmit the applied force to the entire maxilla.When the screw was activated and a protractionforce was exerted, the Cre of the maxilla was
reported to be located approximately in thesame area as that in this study. They, however,did not investigate the Cre of the upperdentition.
Teuscher (1986), and Stckli and Teuscher(1994), distinguished two centres of resistance:one for the maxilla and one for the dentition.By directing the extra-oral force vector betweenthe respective centres of resistance, differentialreaction patterns on the maxilla and the dentition
CENTRE OF RESISTANCE AND UPPER DENTITION 271
8/13/2019 2001 billiet
10/12
might be expected. In this study, no cleardifference in initial displacement (magnitudeand direction) between maxilla and dentitionwas found.
Conclusions
The results of this investigation showed thatthe region of the Cre of the maxilla was situatedunderneath the zygomatic process of the maxillarycomplex. A force vector applied through thisregion induced initially nearly pure translation ofthe maxilla in high-pull as well as with posteriorhorizontal traction. The Cre of the maxilladefined by Teuscher was situated in a moreupward and posterior position. The localisation
of two different Cre as suggested by Teuscher(1986), and Stckli and Teuscher (1994) inactivator-headgear therapy could not be con-firmed by measuring initial displacements on amacerated human skull.
Address for correspondence
Professor Dr Luc DermautDepartment of OrthodonticsUniversity of GentDe Pintelaan 1859000 GentBelgium
References
Baeten L R 1975 Canine retraction: a photoelastic study.American Journal of Orthodontics 67: 1123
Barton J J 1972 High-pull headgear versus cervical traction:a cephalometric comparison. American Journal ofOrthodontics 62: 517529
Bench R W, Gugino C G, Hilgers J J 1978 Bioprogressivetherapy. Journal of Clinical Orthodontics 12: 4869
Brodsky J F, Caputo A A, Furstman L L 1975 Aphotoelastic-histopathological correlation. AmericanJournal of Orthodontics 67: 110
Burstone C J, Pryputniewicz R J, Weeks R 1981 Centerof resistance of the human mandibular molars. Journal ofDental Research 60: 515 (Abstract)
Caputo A A, Chaconas S J, Hayashi R K 1974 Photoelasticvisualisation of orthodontic forces during canine retraction.American Journal of Orthodontics 65: 250259
Chaconas S J, Caputo A A, Davis J C 1976 The effects oforthopedic forces on the craniofacial complex utilizing
cervical and headgear appliances. American Journal ofOrthodontics 69: 527539
De Clerck H, Dermaut L R, Timmerman H 1990 The valueof the macerated skull as a model used in orthopaedicresearch. European Journal of Orthodontics 12: 263271
De Pauw G, Dermaut L 1998 The value of the centre of
rotation in the displacement of tooth and bone structure.European Journal of Orthodontics 19: 447 (Abstract)
Dermaut L R, Beerden L 1981 The effects of Class II elasticforce on dry skull measured by holographic interferometry.American Journal of Orthodontics 79: 296303
Dermaut L R, Vanden Bulcke M 1986a Evaluation ofintrusive mechanics of the type segmented arch on amacerated human skull using the laser reflection tech-nique and holographic interferometry. American Journalof Orthodontics 89: 251263
Dermaut L R, Kleutghen J P, De Clerck H J 1986bExperimental determination of the center of resistance ofthe upper first molar in a macerated, dry human skull
submitted to horizontal headgear traction. AmericanJournal of Orthodontics and Dentofacial Orthopedics90: 2936
Dijkman J F 1969 The distribution of forces in orthodontictreatment. Thesis, University of Nijmegen, The Netherlands
Gambrell S C, Allen J M Jr 1976 Stress concentrations atthe apex of pinned, implanted teeth. Journal of DentalResearch 55: 5965
Govaert L, Dermaut L 1997 The importance of humidity inthe in vitro study of the cranium with regard to initialbone displacement after force application. EuropeanJournal of Orthodontics 19: 423430
Hata S, Itoh T, Nakagawa K, Ichikawa K, Matsumoto M,
Chaconas S J 1987 Biomechanical effects of maxillaryprotraction on the craniofacial complex. AmericanJournal of Orthodontics and Dentofacial Orthopedics91: 305311
Kragt G, Duterloo H S 1982 The initial effects of orthopedicforces: a study of alterations in the craniofacial complexof a macerated human skull owing to high-pull headgeartraction. American Journal of Orthodontics 81: 5764
Kragt G, Ten Bosch J J, Borsboom P C F 1979 Measurementof bone displacement in a macerated human skull inducedby orthodontic forces: a holographic study. Journal ofBiomechanics 12: 905910
Kragt G, Duterloo H S, Ten Bosch J J 1982 The initial
reaction of a macerated human skull caused by ortho-dontic cervical traction determined by laser metrology.American Journal of Orthodontics 81: 4956
Kragt G, Duterloo H S, Algra A M 1986 Initialdisplacements and variations of eight human child skullsowing to high-pull headgear traction determined withlaser holography. American Journal of Orthodontics89: 399406
Kusy R P, Tulloch J F C 1986 Analysis of moment/forceratios in the mechanics of tooth movement. AmericanJournal of Orthodontics and Dentofacial Orthopedics90: 127131
272 T. BILLIET ET AL.
8/13/2019 2001 billiet
11/12
Lee K G, Ryu Y K, Park Y C, Rudolph D J 1997 A studyof holographic interferometry on the initial reaction ofmaxillofacial complex during protraction. AmericanJournal of Orthodontics and Dentofacial Orthopedics111: 623632
Nanda R 1981 The differential diagnosis and treatment of
excessive overbite. Dental Clinics of North America25: 6984
Poulton D R 1959 Changes in Class II malocclusion withand without occipital headgear therapy. Angle Ortho-dontist 34: 181193
Poulton D R 1967 The influence of extraoral traction.American Journal of Orthodontics 53: 818
Stckli P M, Teuscher U M 1994 Combined activatorheadgear orthopedics. In: Graber M, Vanarsdall R L(eds) Orthodontics: current principles and techniques.Mosby, St Louis
Tanne K, Matsubara S 1996 Association between thedirection of orthopedic force and sutural responses in the
nasomaxillary complex. Angle Orthodontist 66: 125130
Tanne K, Matsubara S, Sakuda M 1993 Stress distributionsin the maxillary complex from orthopedic headgearforces. Angle Orthodontist 63: 111118
Tanne K, Matsubara S, Sakuda M 1995 Locations ofthe centre of resistance for the nasomaxillary complexstudied in a three-dimensional finite element model.
British Journal of Orthodontics 22: 227232Teuscher U M 1986 An appraisal of growth and reaction
to extraoral anchorage: simulation of orthodontic-orthopedic results. American Journal of Orthodontics89: 113121
Vanden Bulcke M, Burstone C J, Sachdeva R C, DermautL R 1987 Location of the centers of resistance foranterior teeth during retraction using the laser reflectiontechnique. American Journal of Orthodontics andDentofacial Orthopedics 91: 375384
Worms F W, Isaacson R J, Speider T M 1973 A concept andclassification of centers of rotation and extraoral forcesystems. Angle Orthodontist 43: 384401
CENTRE OF RESISTANCE AND UPPER DENTITION 273