15543.1-89
GOST 15543
UDC 620.193.21:621.3:006.354 Group E08
THE INTERSTATE STANDARD
PRODUCTS ELECTROTECHNICAL
THE GENERAL REQUIREMENTS REGARDING FIRMNESS TO CLIMATIC EXTERNAL INFLUENCING FACTORS
Electrical articles. General requirements for resistance
to environment climatic factorsOKP 34 0000
Date of IntroductionFor again developed and modernised electrotechnical products 01.01.90;
For developed till 01.01.90 electrotechnical *01.01.93___________
* The order of introduction of the standard in action is resulted in the appendix 1.
Details1. It is developed and brought by Ministry of the Electrical Equipment Industry of the USSR
2. APPROVED AND PUT INTO EFFECT the Decision of the State committee of the USSR under standards from 14.07.89 2381.
3. The standard corresponds to international standard 721-2-1 (1982) regarding values of temperature and humidity of air for climatic modifications (types of climates) taking into account regional features of the USSR.
4. INSTEAD OF GOST 15543-70, GOST 16962-71 regarding requirements to electrotechnical products of economic appointment on climatic influences.
5. REFERENCE NORMATIVE AND TECHNICAL DOCUMENTSNumber of reference document on which the reference is givenNumber of point, the appendix
GOST 14254-808
GOST 15150-69The prologue, 1, 3, 5-7, 11.2, 14, appendices 3-5
GOST 23216-7814
6. REPRINTING. August, 2002
This standard extends on electrotechnical products (further products) economic appointment and for the export which list is resulted in the appendix 2, and establishes the general technical requirements on firmness of products to influence of climatic external influencing factors (further - climatic factors of an environment), concretising requirements of GOST 15150 with reference to the products specified above.
The terms applied in this standard, and their explanatories are resulted in the appendix 3.
1. The list and rating values of climatic factors of an environment at operation for kinds of climatic modifications in accordance with GOST 15150 establish according to the table and subitem 2-13.
In technical projects (further - ), standards and specifications on concrete series or types of products (further in standards and THAT on products), depending on their design features and the shown requirements to group of products or to concrete products, spend additional restriction of used kinds of climatic modifications. According to economic and a technical feasibility manufacturing of the products meeting requirements of several kinds of climatic modifications, specified in this standard is recommended.
In , standards and THAT on products specify a climatic modification kind. In the specifications and technical documentation (reference documents) of kind on the products intended only for concrete object, the requirement on firmness of the product planned to working out, if necessary, specify also in the form of values of climatic factors.
Designation of a kind of a climatic modification enter into a symbol of type (mark) of a product according to GOST 15150, section 2, thus specify group of the lowered pressure. In , standards and THAT on products it is supposed to specify in addition height above sea level or pressure.
The note. In this standard at instructions of a kind of a climatic modification in brackets the serial number under the table is specified.2. The kinds of climatic modifications specified in subitem 2, use only for the products specified in these points.
2.1. Kinds of climatic modifications: 2,5 ** (25); 1 ** (56); 2.1 ** (57); 4 ** (58); 1 ** (65); 2.1 ** (66); 4 ** (67); 2.1 ** (90); 2.1 ** (96); 5.1 ** (97); 2.1 ** (99) use for the products specially intended for application as built in elements in heated complete electrotechnical and radio-electronic products if it is caused by specificity of these complete products.
2.2. A kind of climatic modification 3.1 ** (26) use for the products intended for placing on engines of the ships on an air cushion and .
2.3. A kind of climatic modification 4 ** (27) use for the products intended for installation on engines of all kinds of courts (ships).
2.4. A kind of climatic modification 2 ** (71) use for the products intended for installation in motorno-transmissionnyh branches of some mobile installations if it is caused by specificity of these installations.
3. Requirements on limiting working values of temperature of air establish according to GOST 15150, section 4. In particular, if for products in the reference document the indicator of probability of non-failure operation 0,9999 and more for service life more than 5 years to such products make demands on limiting working values of temperature is established.
4. Products of kinds of climatic modifications 1 (21) and 4 (24) produce in a uniform design for two effective temperatures specified in the table with instructions of technical parametres of products at both values of temperature, thus nominal parametres of products should be calculated for temperature 45 .
5. If for products it is necessary to establish distinct from specified in the table of value of climatic factors, they are established according to requirements of GOST 15150, by section 5, 6, 8, 9, and also section 3 (regarding cooling by water, work in water, soil, in tight volumes).
5.1. For the products intended for application as built in elements in heated complete products, the top working value of temperature establish 55 if in standards and specifications on products of concrete series and types others are not established top working and (or) effective the values of temperature caused by conditions of operation of these products in a complete product.
6. Changes of temperature of air and value of temperature of cooling water choose in accordance with GOST 15150, section 3. Effective value of temperature of cooling water should correspond to the top working value.
7. For products to which according to the table on firmness demands are made to influence of a dust, ozone, sunlight, working values of these climatic factors establish according to GOST 15150, section 3.
8. Requirements to water influence show to products for which it is specified in , according to GOST 14254.
9. Products to which according to the table demands on hoarfrost influence are made, should maintain the appendix of nominal electric pressure without breakdown or superficial overlapping at loss on a product of hoarfrost with its subsequent thawing.
10. Requirements on working capacity of products at formation on them of ice show (if it is established in , standards and THAT) to products of executions At, , M, the OHM, the Island In a category 1, and also to intended for operation under a canopy to products of the category 2, having open mobile parts and (or) open disconnected contacts, in particular, to corresponding products on pressure St. 1000 Century
11. It is supposed (if it is established in standards and THAT on products or under the permission of developers or manufacturers of products) constantly to maintain products without change of their resource (or service life) at following values of an ambient temperature.
11.1. At the temperature exceeding effective temperature established in this standard. In this case it is necessary to reduce loading of products so that specified in standards and THAT on products temperatures supposed excess have been reduced by the size equal to a difference between actual and specified in this standard effective temperatures, and the difference should be approximated towards increase to number, multiple 5. Thus, if the specified difference exceeds 10 , it is necessary to be convinced that products can work at actual temperature of those knots and details which at work of products at in standards and THAT on products values of temperature of an environment are not exposed to the heatings close to extremely supposed. In particular, for products on pressure 3 and above it can appear necessary to consider decrease in electric durability firm, liquid and gaseous (including air) materials.
11.2. At temperature less than effective temperature established in this standard. In this case it is supposed to increase loading of products so that temperatures extremely supposed excess have been increased by the size equal to a difference between specified in this standard and actual effective in temperatures. Thus, if the specified difference exceeds 10 for electric cars (except a turbo - and hydrogenerators with length of the core to 2) or 20 for other products, it is necessary to be convinced of an increase admissibility temperatures, proceeding from a difference of factors of thermal expansion of materials, speed of increase of temperature of details at inclusion of products, temperature drops in products, etc.
The note. The actual effective temperature is defined according to GOST 15150, by section 6.
12. In the limits specified in the standard of ranges of climatic factors, some values of the same factor can be established at an establishment of requirements concerning separate technical characteristics (for example, some values top and (or) effective temperature at various resources or service life of products).
13. Requirements on firmness to climatic factors of an environment for cables, wires, cords and tyres, and also for brushes of electric cars, establish according to appendices 4 and 5.
14. Requirements on firmness to climatic factors of an environment at transportation and storage establish in accordance with GOST 15150 according to GOST 23216.
/Kind
klimati -
Executions
In accordance with GOST 15150Air temperature, (WithRelative humidityPressure of air
Working valueLimiting working valueEffective valueWorking valueEffective valueWorking value
The topThe bottomAverageThe topThe bottomThe topAverage%At rate -
, CThe topThe bottom
%At rate -
, (With%At rate -
, (WithMm hgMm hg
12
3
4
5B12,5
3
B4550, 55, 60*
50 **
5045
45-60-60
-60
-10 ***
-402727
27
27
2760, 65, 65*
60*
60
55
45-70-70
-70
-10 ***
-4045, 50, 50*45 **
45
45
45100100
98
98
1003535
35
35
358080
70
70
802727
27
27
278080
70
70
702727
27
27
27106,7106,7
106,7
106,7
106,7800800
800
800
80086,686,6
86,6
86,6
86,6650650
650
650
650
67
8
912
4
550, 55, 60*
50 **
45
35-60-60
1
-102727
27
2760, 65, 65*
60 **
55
35-70-70
1
-1045, 50, 50*45 **
45
35100100
98
1003535
35
358080
70
802727
27
278080
70
802727
27
27106,7106,7
106,7
106,7800800
800
80086,686,6
86,6
86,6650650
650
650
10
11
12
13
14
15
161
1.1
2
3
4
4.2
540, 45, 50*
40, 45, 50*
40 **
40
35
35
35-60
-60
-60
-60
1
10
-1015
15
15
15
20
20
1545, 55, 55*
45, 55, 55*
45 **
45
40
40
35-70
-70
-70
-70
1
1
-1040
40
40
40
35
25
35100
98
100
98
80
80
10025
25
25
25
25
25
2580
70
80
80
60
60
9015
15
15
15
20
20
1580
70
8080
60
60
9020
20
20
20
20
20
20106,7
106,7
106,7
106,7
106,7
106,7
106,78001
800
800
800
800
800
80086,6
86,6
86,6
86,6
86,6
86,6
86,6650
650
650
650
650
650
650
17
18
19
201
1.1
T2
T350, 55, 60*
50, 55, 60*
50 **
50-10
-10
-10
-1027
27
27
2760, 65, 65*
60, 65, 65*
60 **
60-10
-10
-10
-1045, 50, 50*
45
45 **
45100
98
100
9835
35
35
3580
70
80
7027
27
27
2780
70
80
7027
27
27
27106,7
106,7
106,7
106,7800
800
800
80086,6
86,6
86,6
86,6650
650
650
650
21
22
23
24OM1
OM2,5
OM3.1
OM445, 45, 50*
45 **
45
45, 50*6-40
-40
-10 ***
-10 ***27
27
27
2760
60
60
45, 60*6-40
-40
-10 ***
-10 ***45, 45, 50*
45 **
45
45, 50*6100
100
98
9835
35*835*835*880
80
70
7027
27
27
2780
80
70
7027
27
27
27106,7
106,7
106,7
106,7800
800
800
80086,6
86,6
86,6
86,6650
650
650
650
25
26
27OM2,5 **OM3,1 **
OM4 **70*7100
85*7*10-40
-10 ***
-10 ***-
-
-70*7100
85*7, *10-40
-10 ***
-10 ***70*7100
85*7, *10100
98
9835*835*835*880
70
7027
27
2780
70
7027
27
27106,7
106,7
106,7800
800
80086,6
86,6
86,6650
650
650
28
29
30
31M12
3.1
440, 40, 45*
40 **
40 **
40, 45*6-40
-10
-10 ***
-10 ***22
22
22
2245, 45, 50*
45 **
45 **
40, 45*6-40
-40
-10 ***
-10 ***40
40
40
40100
100
98
9825
25
25
2580
80
80
8022
22
22
2285
85
75
7522
22
22
22106,7
106,7
106,7
106,7800
800
800
80086,6
86,6
86,6
86,6650
650
650
650
32
33
34
351
1.1
2
340, 45, 50*
40, 45, 50*
40 **
40-451
-45
-45
-4515
15
15
1545, 55, 55*
45, 55, 55*
45 **
45-50
-50
-50
-5040
40
40
40100
98
100
9825
25
25
2580
70
80
8015
15
15
1580
70
80
8020
20
20
20106,7
106,7
106,7
106,7800
800
800
80086,6
86,6
86,6
86,6650
650
650
650
36
37
381
2
450, 55, 60*
50 **
45-10
-10
127
27
2760, 65, 65*
60 **
55-10
-10
145, 50, 50*
45 **
45100
80
8025
25
2540
40
4027
27
2760
60
5527
27
27106,7
106,7
106,7800
800
80086,6
86,6
86,6650
650
650
39
40
41
42O1a
2
3
450, 55, 60*
50 **
50
45-60
-60
-60
127
27
27
2760, 65, 65*
60 **
60
55-70
-70
-70
145, 50, 50*
45 **
45
45100
100
98
9835
35
35
3580
100
70
7027
35
27
2780
80
70
7027
27
27
27106,7
106,7
106,7
106,7800
800
800
80070,0
70,0
70,0
70,0525
525
525
525
43
44
45
46
471
2
3
4
540, 45, 50*
40 **
40
35
35-60
-60
-60
1
-1015
15
15
20
1545, 55, 55*
45 **
45
40
35-70
-70
-70
l
-1040
40
40
35
35100
100
98
80
10025
25
25
25
2580
80
80
659015
15
15
20
1580
80
80
65
9020
20
20
20
20106,7
106,7
106,7
106,7
106,7800
800
800
800
80070,0
70,0
70,0
70,0
70,0525
525
525
525
525
48
49
501
2
340, 45, 50*
40 **
40-45
-45
-4515
15
1545, 55, 55*
45 **
45-50
-50
-5040
40
40100
100
9825
25
2580
80
8015
15
1580
80
8020
20
20106,7
106,7
106,7800
800
80070,0
70,0
70,0525
525
525
51
52
53
54
551
2
2.1
3
3.150, 55, 60*
50 **
50 **
50 **
50 **-60
-60
-60
-60
-10*927
27
27
27
2760, 65, 65*
60 **
60 **
60 **
60 **-70
-70
-70
-70
-10*945, 50, 50*
45 **
45 **
45 **
45 **100
100
98
98
9835
35
35
35
3580
80
80
70
7027
27
27
27
2780
80
80
70
7027
27
27
27
27106,7
106,7
106,7
106,7
106,7800
800
800
800
80053,3
53,3
53,3
53,3
53,3400
400
400
400
400
56
57
581 **
2.1 **
4 **85*1085*1085*10-60
-60
-10 ***-
-
-85*1085*1085*10-70
-70
-10 ***85*1085*1085*10100
98
9835
35
3580
80
7027
27
2780
80
7027
27
27106,7
106,7
106,7800
800
80053,3
53,3
53,3400
400
400
59
60
61
62
63
641
2
2.1
3
3.1
440, 45, 50*
40 **
40 **
40
40 **
35-60
-60
-60
-60
-10*9115
15
15
15
15
2045, 55, 55*
45 **
45 **
45
45 **
40-70
-70
-70
-70
-10*9140
40
40
40
401
35100
100
98
98
98
802525
25
25
25
2580
80
80
80
80
6015
15
15
15
15
2080
80
80
80
80
6020
20
20
20
20
20106,7
106,7
106,7
106,7
106,7
106,7800
800
800
800
800
80053,3
53,3
53,3
53,3
53,3
53,3400
400
400
400
400
400
65
66
671 **
2,1 **
4 **85*1085*1085*10-60
-60
1-
-
-85*1085*1085*10-70
-70
185*1085*10
85*10100
98
8025
25
2580
80
6015
15
2080
80
6020
20
20106,7
106,7
106,7800
800
80053,3
53,3
53,3400
400
400
68
69
70
711
2
4
2 **50, 55, 60*
50 **
45
125-60
-60
1
-6027
27
27
2760, 65, 65*
60 **
55
125-70
-70
1
-7045, 50, 50*
45 **
45
125100
100
98
10035
35
35
3580
80
70
8027
27
27
2780
80
70
8027
27
27
27106,7
106,7
106,7
106,7800
800
800
80053,3
53,3
53,3
53,3400
400
400
400
72
73
741
2
340, 45, 50*
40 **
40-45
-45
-4515
15
1545, 55, 55*
45 **
45-50
-50
-5040
40
40100
100
9835
35
3580
80
8015
15
1580
80
8020
20
20106,7
106,7
106,7800
800
80053,3
53,3
53,3400
400
400
75
76
771
2
350, 55, 60*
50 **
50 **-60
-60
-60*1127
27
2785*1270
70-70
-70
-70*1145, 50, 50*
45 **
45 **100
100
9835
35
3580
80
7027
27
2780
80
7027
27
27106,7
1,06,7
106,7800
800
80026,7
26,7
26,7200
200
200
78
79
801
2
350, 55, 60*
50 **
50-60
-60
-60*1127
27
2785*1270
70-70
-70
-70*1145, 50, 50*
45 **
45100
100
9835
35
3580
80
7027
27
2780
80
7027
27
27106,7
106,7
106,7800
800
80012,0
12,0
12,090
90
90
81
82
831
2
350, 55, 60*
50*
45-60
-60
-60*1127
27
2785*1270
70-70
-70
-70*1145, 50, 50*
45 **
45100
100
9035
35
3580
80
7027
27
2780
80
7027
27
27106,7
106,7
106,7800
800
8002,0
2,0
2,015
15
15
84
85
86
871
2
2.1 **
350, 55, 60*
50 **
85*1050-60
-60
-60
-60*1127
27
-
2785*1270
85*1070-70
-70
-70
-70*1145, 50, 80*
45 **
85*1045100
100
98
9835
35
35
3580
80
80
8027
27
27
2780
80
80
7027
27
27
27106,7
106,7
106,7
106,7800
800
800
8000,6
0,6
0,6
0,65
5
5
5
88
89
90B1
2
2.1 **50, 55, 60*
50 **
85*10-60
-60
-6027
27
2760, 65, 65*
60*
85*10-70
-70
-7045, 50, 50*
45 **
85*10100
100
9835
35
3580
80
8027
27
2780
80
8027
27
27106,7
106,7
106,7800
800
8001,3(10-71,3(10-71,3(10-710-610-610-6
91
92
93
94
95
96
971
2
2.1
3.1
5.1
2.1 **
5.1 **40, 45, 50*
40 **
40 **
40
35
85*1085*10-60
-60
-60
-10*9-10
-60
-1015
15
15
15
15
-
-45, 55, 55*
45 **
45 **
45
35
85*1085*10-70
-70
-70
-10*9-10
-70
-1040
40
40
40
35
85*1085*10100
100
98
98
98
98
9835
25
25
25
25
25
2580
80
80
70
90
80
9015
15
15
15
15
15
1580
80
80
80
90
80
9020
20
20
20
20
20
20106,7
106,7
106,7
106,7
106,7
106,7
106,7800
800
800
800
800
800
8001,3(10-71,3(10-71,3(10-71,3(10-71,3(10-71,3(10-71,3(10-710-610-610-610-610-610-610-6
98
99
100
1012.1
2.1 **
*
*40
85*1030
25-60
-60
-2
-215-27
2045
85*1035
30-70
-70
-4
-440
85*1030
2598
98
-
-25
25
-
-80
80
-
-15
15
-
-80
80
-
-20
20
-
-106,7
106,7
106,7
106,7800
800
800
8001,3(10-141,3(10-1486,6
86,610-1310-13650
650
Continuation /Climatic modification kind in accordance with GOST 15150Pressure of airSunlightIntensity of a rain or falling of drops (the top working value), mm/minesThe hydrochloric
FogHoarfrostDustOzonekorrozionno -Active agents, atmosphere type in accordance with GOST 15150Action
Mushrooms
Working valueLimiting working valueThe top value of height above sea level, km
AverageThe bottom
Mm hgMm hg
12
3
4
5B1B2,5
3
4
589,989,9
89,9
89,9
89,9674674
674
674
6748484
84
84
84630630
630
630
6301,001,00
1,00
1,00
1,00+-
-
-
-50,4
-
-
0,4++*4-
-
-++*4-
-
-++*4
-
-HH*5-
-
-IV and IIIIV ** 4 and III*4
-
-++
+
+
+
67
8
912
4
589,989,9
89,9
89,9674674
674
6748484
84
84630630
630
6301,001,00
1,00
1,00+-
-
-5-
-
-H-
-
-++*4-
-++*4-
-HH
-
-IVIV*4-
-++
+
+
10
11
12
13
14
15
161
1.1
2
3
4
4.2
589,9
89,9
89,9
89,9
89,9
89,9
89,9674
674
674
674
674
674
67484
84
84
84
84
84
84630
630
630
630
630
630
6301,00
1,00
1,00
1,00
1,00
1,00
1,00+
+
-
-
-
-
-3
3
-
-
-
-
-
H
*5-
-
-
-+
+
+*4
-
-
-
-H
H
H
-
-
-
-H
H
H*5-
-
-
-II and III and III*4 And I*4H
-
-
--
-
-
-
-
-
-
17
18
19
20T1
T1.1
T2
389,9
89,9
89,9
89,9674
674
674
67484
84
84
84630
630
630
6301,00
1,00
1,00
1,00+
+
-
-5
5
-
-H
H
H*5--
-
-
-+
H
+*4HH
H
H*5-II and III and III*4 And I*4H+
+
+
+
21
22
23
24OM1
OM2,5
OM3,1
489,9
89,9
89,9
89,9674
674
674
67484
84
84
84630
630
630
6301,00
1,00
1,00
1,00+
-
-
-5
0,4
-
-+
+
-
-+
+*4-
--
-
-
-H
H*5-
-III
III
H-+
+
+
+
25
26
27OM2,5 ***
OM3,1 ***4 ***89,9
89,9
89,9674
674
67484
84
84630
630
6301,00
1,00
1,00-
-
-0,4
-
-+
-
-+*4-
--
-
-H*5
-
-III
H
-+
+
+
28
29
30
31M1
2
3.1
489,9
89,9
89,9
89,9674
674
674
67484
84
84
84630
630
630
6301,00
1,00
1,00
1,00+
-
-
-3
0,4
-
-+
+
-
-+
+
-
--
+*4-
-H
H*5-
-III
III
H
--
-
-
-
32
33
34
351
1.1
2
389,9
89,9
89,9
89,9674
674
674
67484
84
84
84630
630
630
6301,00
1,00
1,00
1,00+
+
-
-3
3
-
-H
H*5--
-
-
-H
H
H*5-H
H
H*5-II and I
II and I
II*4 And I*4H-
-
-
-
36
37
381
2
489,9
89,9
89,9674
674
67484
84
84630
630
6301,00
1,00
1,00+
-
-3
-
-+
-
--
-
-+
+*4-H
H*5-II and I
II*4 I*4--
-
-
39
40
41
42O1a
2
3
475,6
75,6
75,6
75,6567
567
567
567-
-
-
--
-
-
-2,4
2,4
2,4
2,4+
-
-
-5
-
-
-H
-
-
-+
+*4-
-+
+*4H
-H
H*5-
-IV
IV*4
-+
+
+
+
43
44
45
46
471
2
3
4
575,6
75,6
75,6
75,6
75,6567
567
567
567
567-
-
-
-
--
-
-
-
-2,4
2,4
2,4
2,4
2,4+
-
-
-
-3
-
-
-
-H
H*5-
-
-+
+*4-
-
-H
H
-
-
-H
H*5-
-
-II and I
II*4 And I*4
-
--
-
-
-
-
48
49
501
2
375,6
75,6
75,6567
567
567-
-
--
-
-2,4
2,4
2,4+
-
-3
-
-H
H*5--
-
-H
H*5-H
H*5-II and I
II*4 And I*4-
-
-
51
52
53
54551
2
2.1
3
3.159,3
59,3
59,3
59,3
59,3445
445
445
445
445-
-
-
-
--
-
-
-
-4,3
4,3
4,3
4,3
4,3+
-
-
-
-5
-
-
-
-+
+ *4
-
-
-+
+ *4
-
-
-+
+**4H
H
HH
H*5-
-
-IV and IIIIV*4 And III*4H
H
H+
+
+
+
+
56
57
581 **
2.1 **
4 **59,3
59,3
59,3445
445
445-
-
--
-
-4,3
4,3
4,3+
-
-5
-
-+
-
-+
-
-+
H
-H
-
-IV and III
H
-+
+
+
59
60
61
62
63
641
2
2.1
3
3.1
459,3
59,3
59,3
59,3
59,3
59,3445
445
445
445
445
445-
-
-
-
-
--
-
-
-
-
-4,3
4,3
4,3
4,3
4,3
4,3+
-
-
-
-
-3
-
-
-
-
-
*5-
-
-
-+
+ *4
-
-
-
-
-
-
-
*5-
-
-
-II and I
II*4 And I*4
--
-
-
-
-
-
65
66
671 **
X2.1 **
4 **59,3
59,3
59,3445
445
445-
-
--
-
-4,3
4,3
4,3+
-
-3
-
-
-
--
-
-
-
-
-II and I
-
-
-
68
69
70
7112
4
2 **59,3
59,3
59,3
59,3445
445
445
445-
-
-
--
-
-
-4,3
4,3
4,3
4,3+
-
-
-5
-
-
-
-
-
-+
+*4-
+*4+
+*4-
+*4
*5-
*5IV
IV*4-
IV*4+
+
+
+
72
73
741
2
359,3
59,3
59,3445
445
445-
-
--
-
-4,3
4,3
4,3+
-
-3
-
-
*5--
-
-
*5-
*5-II and I
II*4 And I*4-
-
-
75
76
771
2
329,0
29,0
29,0218
218
218-
-
--
-
-9,4
9,4
9,4+
-
-5
-
-+
+*4-+
+*4-+
+*4
*5-IV and IIIIV*4 And III*4+
+
+
78
79
801
2
313,0
13,0
13,0100
100
100-
-
--
-
-14,4
14,4
14,4-
-
-5
-
-+
+*4-+
+*4-+
+*4
*5-III and IV
IV*4 And III*4+
+
+
81
82
831
2
32,2
2,2
2,216
16
16-
-
--
-
-26,0
26,0
26,0-
-
-5
-
-+
+*4-+
+*4-+
+*4
*5-III and IV
IV*4 And III*4+
+
+
84
85
86
871
2
2.1 **30,6
0,6
0,6
0,65
5
5
5-
-
-
--
-
-
-34,0
34,0
34,0
34,0-
-
-
-5
-
-
-+
+*4-
-+
+*4-
-+
+*4-
*5-
-III and IV
IV*4 And III*4
+
+
+
+
88
89
901
2
B2.1 **1,3(10-71,3(10-71,3(10-710-610-610-6-
-
--
-
-200
200
200+
-
-5
-
-+
+*4-+
+*4-+
+*4
+*4-III and IV
IV*4 And III*4+
+
+
91
92
93
94
95
96
971
2
2.1
3.1
5.1
2.1 **
5.1 **1,3(10-71,3(10-71,3(10-71,3(10-71,3(10-71,3(10-71,3(10-710-610-610-610-610-610-610-6-
-
-
-
-
-
--
-
-
-
-
-
-200
200
200
200
200
200
200+
-
-
-
-
-
-3
-
-
-
-
-
-
*5-
-
-
-
-+
+*5-
-
-
-
-
-
-
*5-
-
-
-
-II and I
II*4 And I*4
-
--
-
-
-
-
-
-
98
99
100
1012.1
2.1 **
*
*1,3(10-141,3(10-1489,9
89,910-1310-13674
674-
-
84
84-
630
630More than 200
More than 200
1
1-
-
-
--
-
-
--
-
-
--
-
-
-
-
--
-
-
-
-
-
-
-
* The first of the values of temperature specified in a given line concerns the products which design features provide absence of additional excess of temperature of windings, knots, contacts and knots of a friction owing to heating of products by solar beams. The second value of temperature concerns to painted in white or silver-white colour to products, and the third value of temperature - to painted in any colour, except white or silver-white, to the products which design features do not provide absence of additional excess of temperature of windings, knots, contacts and knots of a friction owing to heating by solar beams of products.
For products in a plastic or wooden cover the second and third value of the working and limiting worker (and for products in a metal cover with a thermal protection - only the limiting worker) should be increased temperatures on 5 , for planes and helicopters - on 10 (With.
** To the products intended for placing in a cover of complete products of categories of placing 1 or 1.1 in accordance with GOST 15150, (1, 6, 10, 11, 17, 18, 21, 28, 32, 33, 36, 39, 43, 48, 51, 59, 68, 72, 75, 78, 81, 84, 88, 91), except for well ventilated and (or) blown, requirements on values of temperature should be accepted same, as for a complete product as a whole, or under this standard item 5.
*** For storage and transportation to operation, for example, at breaks in work, the bottom value of temperature should be accepted same, as for the sake of appearances climatic modification 2,5 (22).
*4 Only for e, specially intended for placing under a canopy, for other products of the given kind of a climatic modification - designation .
*5 Only for the products specially intended for placing under a canopy, for other products of the given kind of a climatic modification - a sign -.
*6 the Second of the values of temperature specified in a given line concerns the products placed in machine, boiler branches and on galleys of courts (ships), except the products cooled by a fence of external air, and except the products placed on courts which conditions of ventilation provide essential equalising of conditions in the specified branches and on external air.
*7 It is supposed 55 in coordination with the customer, item 5.1 see.
*8 Limiting working value - 100 % at 50 .
*9 For storage and transportation to operation, for example, at breaks in work, the bottom value of temperature should be accepted same, as for the sake of appearances climatic modification (13).
*10 parametres of products (including a resource or the minimum operating time) for temperature 70 and 125 Should be specified.
*11 For volumes with adjustable temperature (a category 3.1) the bottom value of temperature for product work set in standards and specifications on products.
*12 Only for planes, for other products 70 .Notes:
1. The sign - means, that influence of factors is not considered, the sign + - influence of factors is considered necessarily, the sign -influence of factors is considered, if it is specified in the reference document in a product.
2. For products with top value of height above sea level more than 1,0 km in standards and specifications on products can be for height more than 1,0 km differing from specified in the table of value of climatic factors (except pressure and the bottom value of temperature). Thus the top, average and effective values of temperatures normalised for work of products at heights St. 1,0 to 4,3 km, can be calculated by reduction of the values specified in the table on 0,6 on each 100 m St. 1,0 km.
3. Specified in the table top value of relative humidity is normalised also at lower temperatures, at more heats relative humidity more low.
At the top value of 100 % to products make demands on firmness to action of condensation of a moisture, at the top value of 80 and 98 % the requirement on firmness to action of condensation of a moisture do not show.
4. For power transformers of climatic modifications In, About, (HARDWARE), the OHM, M (1-9, 12-22, 24, 28, 29, 31, 36-38) with filling with oil both a nonflammable liquid and cooling of a kind of M or accept effective temperature of air equal 50 (C.
5. For light sources and lighting devices of categories of placing 1; 2; 2.1; 3; 3.1; 2,5 in accordance with GOST 15150 (1-3; 6; 7; 10-13; 17-23; 28-30; 32-37; 39-41; 43-45; 48-55; 59-63; 68; 69; 72-88; 90-93) effective value of temperature is supposed to be accepted on 5 more low, than it is specified in the table.
6. For the products intended for work at pressure below 1 mm hg, for the effective accept temperature of a cover of an idle product.
7. For power semi-conductor converters of the electric power, thermal relays and other products which increase in temperature above certain value leads to spasmodic qualitative changes, as effective temperature accept the top value of working temperature.
8. For the products intended for operation only in atmosphere of type 1 in accordance with GOST 15150, it should be specified in the reference document in a product.
9. Requirements on influence of a snow dust show according to GOST 15150, thus requirements on working capacity or show to the products corresponding to categories of placing 1, 1.1, 2 (for a category 2-except protected on an installation site), for execution in accordance with GOST 15150 in all cases, for executions At, About, In - if it is specified in , standards or THAT in products.
10. Kinds of a climatic modification the OHM * (100), * (101) apply M to the products intended for work in water. If in , standards and THAT on products necessity of storage and transportation for operation in other conditions for these conditions of value of climatic factors accept same as for climatic modification kinds accordingly 2,5 (25), 2 (29) if in , standards and THAT on products less rigid values are not established is established.
11. Concrete types or groups of exported products for macroclimatic area with a warm temperate climate (THAT) in accordance with GOST 15150 it is supposed to produce THAT if constructive differences of products of this execution from products of a climatic modification of U.Dlja of products of execution THAT of categories 1 are tehniko-economically proved in a climatic modification, 1.1, 2, 2.1, 3 bottom working value of temperature accept equal a minus 25 , the bottom limiting value of temperature - a minus 30 (With, values of other climatic factors-same, as for execution At.
THE APPENDIX 1 The obligatoryORDER OF INTRODUCTION OF THE STANDARD IN ACTION
1. For again developed standards and products (and also modernised products) term of introduction of the standard is established since January, 1st, 19902. For the standards developed till January, 1st, 1990 and products standard introduction is carried out during the period till January, 1st, 1993 at revision of standards and THAT on products.THE APPENDIX 2 The obligatoryTHE LIST OF PRODUCTS ON WHICH THIS STANDARD EXTENDS
Electric cars (electric motors, jacks, generators, converters, amplifiers, the synchros rotating transformers, phase shifters and phase-shifters induction, gauges induction, , the converter a corner - a code, electromagnetic , etc.).
Transformers and reactors with frequency to 400 Hz ., except the transformers of a food intended for electronic equipment on pressure to 1000 In low power (to 1000 ), food transformers on pressure to 20 , , pulse, , remembering transformers.
Electric devices, including: switching devices of distribution of energy, protection and management of receivers of energy of an alternating voltage with frequency to 400 Hz . And constant pressure to 1000 and St. 1000 In, electromagnets, devices (including contact cars).
The electrothermal equipment, including electroheaters and heating electrohousehold appliances.
Electroadjusting both connecting products and armature for variable with frequency to 400 Hz . And constant pressure, including connectors, devices, assembly laths, holders of safety locks, plugs, cartridges and lamp panels, armature for cable and air-lines of electricity transmissions, contact networks, lighting armature.
Lighting products, including lighting devices, complete sets, complexes.
Electric light sources (except lamps of rating ).
Electropottery, including insulators and systems of insulators.
Chemical sources of a current.
Physical sources of a current.
Fuel elements.
devices.
Power condensers (including , on industrial frequency).
Power semi-conductor devices.
Power semi-conductor converters of the electric power.
Power contactless control facilities.
High-frequency electric equipment.
Cables, wires, cords.
Electrocoal products.
Household electromechanical devices and the household combined electrodevices (including washing machines).
Complete electrotechnical products: complete switching centres on pressure St. 1000 In, transformer substations, condenser installations, low-voltage complete devices (), complete electric drives, electrounits and power stations of a food with internal combustion engines and mobile power stations of other types, complete systems of power supplies.
Units and electromechanisms.
Electrotransport (a complete product as a whole), except the main electric locomotives, city and suburban electrotransport.THE APPENDIX 3 The help
THE TERMS APPLIED IN THIS STANDARD, AND THEIR EXPLANATORIESThe termThe explanatory
1. Climatic factors of an environmentIn accordance with GOST 15150
2, Normal values of climatic factors of an environmentIn accordance with GOST 15150
3. Rating values of climatic factors of an environmentIn accordance with GOST 15150
4. Working values of climatic factors of an environmentIn accordance with GOST 15150
5. Limiting working values of climatic factors of an environment at operationIn accordance with GOST 15150
6. Humidity of airIn accordance with GOST 15150
7. The built in elementIn accordance with GOST 15150
8. Effective value of the climatic factorIn accordance with GOST 15150
9. Environment temperature at operationIn accordance with GOST 15150
10. A complete productIn accordance with GOST 15150
11. A heated productCables, wires, cords, the tyres intended for transfer to such capacity of an electromagnetic field under which action excess of temperature of separate elements of a product over environment temperature reaches 10 and more
THE APPENDIX 4
The obligatoryESTABLISHMENT OF REQUIREMENTS ON FIRMNESS TO CLIMATIC FACTORS OF THE ENVIRONMENT IN STANDARDS AND SPECIFICATIONS ON CABLES, WIRES, CORDS AND TYRES AND TYPICAL FORMULATIONS
1. GENERAL PROVISIONS
1.1. The kind of a climatic modification of cables, wires (except ), and tyres specify in the same formulations, as for other electrotechnical products. If cables are intended for a lining in soil, it in addition specify in the prologue or in section Execution of products. For example: cables make a kind of a climatic modification 1 in accordance with GOST 15150, and also for a lining in soil.
At a choice of kinds climatic execution according to this standard requirements in addition accept the following:
The cables intended for a lining in soil with an exit to stationary electroinstallations or other electrotechnical products, working on open air, carry to the kinds of climatic modifications corresponding to categories 1 or 2 in accordance with GOST 15150 according to requirements of the standard on cable products;
Tyres not isolated, for air-lines of electricity transmissions or communication carry wires to the kinds of a climatic modification corresponding to a category 1;
Cords connecting for household appliances carry to the kinds of climatic modifications corresponding, as a rule, to a category 4.
1.2. Conditions of operation of cables, wires (except ), cords and tyres specify in the same formulations, as for other electrotechnical products. In addition specify value of the bottom temperature at operation in the formulation of item 1.3 of the present appendix.
1.3. The bottom value of temperature at operation specify in the following formulation: The bottom value of temperature at operation: In the absence of deformations - a minus... ;
In the presence of deformations - a minus (plus)... , including at installation and reinstallation (or a lining) - a minus (or plus)... .
As deformations in the present point understand processes of a bend, axial torsion, a stretching .
The bottom value of temperature for a case of absence of deformations at operation choose the most rigid from among values, this standard for the sake of appearances a climatic modification specified according to item 1.1 of the present appendix. Thus, as a rule, choose working values of temperature.2. RATIONING OF THE TOP AND EFFECTIVE VALUES OF TEMPERATURE FOR CABLES, WIRES (EXCEPT ), CORDS AND TYRES
2.1. For not heated cables, wires, cords and tyres normalise top or () effective value of temperature of an environment.
2.2. For heated cables, wires, cords and the tyres intended for work, as a rule, in normal conditions (for example, power cables), normalise the top and effective values of temperature of an environment and in case of need - values of temperature on a vein.2.3. For heated cables, wires, cords and the tyres intended according to item 5 of this standard for operation, as a rule, at values of climatic factors, differing from established in the table, in particular, in electrotechnical or radio-electronic products (for example, for adjusting and assembly wires), instead of value of temperature of an environment normalise top or () effective value of temperature of a vein for least an element of a cable, a wire, a cord or the tyre.
2.4. At a choice of the top value of temperature of products for kinds of the climatic modifications corresponding to a category 1, consider requirements of GOST 15150 (section 3 regarding temperature of surfaces, section 5 - regarding products in a plastic cover).
2.5. As the heated understand cables, wires, cords, the tyres intended for transfer to such capacity of an electromagnetic field under which action excess of temperature of separate elements of a product over environment temperature reaches 10 (With and more.3. VALUES ADMISSIBLE LOADINGS ON CABLES, THE WIRE (EXCEPT ), CORDS AND TYRES
3.1. For the effective values of temperature specified in this standard for kinds of climatic modifications, corresponding to a climatic modification At (temperature of air 40 ) or the temperature of water or soil 25 ), accept sizes admissible loadings which in Rules of the device of electroinstallations (PUE) or the directories supposed when due hereunder for designing, are carried to settlement temperature of air 25 With or temperature of water or soil 15 (With.
3.2. If for any kind of a climatic modification specified in this standard table the effective temperature differs from specified for execution At in item 3.1 of the present appendix, apply correction factors on temperature of soil, water or air.
For concrete values of a difference between demanded and specified in item 3.1 effective values of temperature accept the correction factors specified in PUE or directories, supposed when due hereunder for designing, for the same values of a difference between actual and settlement temperatures.
For example, if cables are intended for operation in the conditions of 2 in accordance with GOST 15150 then demanded effective value of temperature according to this standard table (taking into account a footnote **) is equal 50 , and a difference between demanded and specified in item 3.1 of the present appendix effective value of temperature makes 10 (50 40 ). In this case accept the correction factor specified in PUE for actual temperature 35 (25 + 10 ).
3.3. If the actual temperature of an environment at long operation of cables, wires, cords, tyres is known and differs from 25 for air or 15 for water and soil, accept correction factors on the environment temperature, specified in PUE or the directories supposed when due hereunder for designing.
The note. Requirements of the present section apply because of necessity of combination of values of conditional temperatures of an environment on which are based accepted for calculation of rated loads of value maximum permissible temperatures of parts of electrotechnical products and which have appeared unequal for cable products and for the majority of other electrotechnical products maintained in the same normal climatic conditions.
4. APPLICATION AND THE FORMULATION THE REQUIREMENT REGARDING CLIMATIC FACTORS OF THE ENVIRONMENT AT OPERATION FOR WIRES
4.1. Climatic modifications and categories of placing do not specify.
4.2. At an establishment of requirements on operation conditions on this standard and GOST 15150 do not refer.
4.3. The top and effective values of temperature do not specify, and specify a class to isolation, behind an exception the wires specially intended for work in specific conditions (for example for the wires intended for water-or electric motors, specify the top and effective values of temperature, instead of a class to isolation).
If to isolation of wires above class , instead of a class specify some values of temperature and an isolation resource.
4.4. The bottom value of temperature at operation write down in the following formulation: the Bottom value of temperature at operation - a minus 60 .
The note. If on operation conditions it is required to specify the bottom value of temperature differing from a minus 60 , at a choice of this value 15150 (section 5) are guided by tab. 1 of this standard and GOST. Thus, as a rule, choose the bottom working value of temperature.
4.5. Other climatic factors do not normalise.THE APPENDIX 5 The obligatoryESTABLISHMENT OF REQUIREMENTS TO BRUSHES FOR ELECTRIC CARS REGARDING INFLUENCE OF CLIMATIC FACTORS OF THE ENVIRONMENT AND TYPICAL FORMULATIONS
1. In standards and specifications on brushes for electric cars of a condition of operation write down in the formulation specified more low if according to subitem 2-5 of the present appendix it is not required changes of this record:
Brushes for electric cars (further - brushes) are intended for operation in the conditions of 2, 3 and 4 in accordance with GOST 15150.
Application of brushes in conditions, for other climatic modifications, and also categories 1 and 5 in accordance with GOST 15150, make with the coordination of their application when due hereunder between the organisation-holder of the original of the design documentation (or the developer) electric cars and the developer of brushes .
2. On occasion the coordination of application of brushes, for other climatic modifications, can be spent with the consumer of brushes. The requirement regarding the application coordination does not extend on direct export deliveries if in the order concrete marks of brushes are specified.
3. If the coordination of application of the brushes, provided in item 1, is spent to the statement of standards or specifications (or changes to these standards or specifications) on brushes in standards or specifications on brushes specify all co-ordinated conditions of operation for concrete types of electric cars.
4. If according to the documentation operating till the moment of introduction of the given appendix, a brush of serial marks are applied in products of tropical execution, the additional coordination of application of brushes it is not required.
5. Regarding conditions of operation of brushes instead of the top and effective value of temperature of an environment the top and effective value of maximum permissible temperature of a brush can be specified.
6. A designation of a kind of a climatic modification into a designation of mark of a brush do not enter, in the accompanying document specify climatic areas and placing categories for which brushes are intended.
Top Related