INTRODUCTION TO ZONING
Static regain zones better than conventional3 ways to zone
1. Variable CFM out of the blower to match Static Pressure / Zones calling
2. Bypass excess air• Bypass to a dump zone• Bypass to return
3. Increase the number of outlets in each zone
04/22/23 10ZONING SOLUTIONS
The Realities of Zoning Success
• Increased Available Supply static pressure when Low load zones satisfy
• Increased Branch duct velocity delivers Colder, Dryer air (more BTU’s to the space) when available supply static increases.
• Decrease in coil velocity increases BTU/CFM transfer
• Coil icing issues only occur when set point is not achieved causing extended cycle time.
04/22/23 11ZONING SOLUTIONS
ZONE PAKDAMPER SYSTEM
04/22/23 12ZONING SOLUTIONS
Up
Porch
Kitchen
Dinnette
Foyer
Office
½ Bath
Living RmFormal Dinning
Up
Mstr Closet
Mstr Bed Room
Bed Room
Bed Room
Bath
1st Floor 2nd Floor
Joe’s House
Porch
Porch
Porc
h
Zone 1 - 1st Fl Living Area (565 sq ft)
Zone 2 - 1st Fl Kitchen/Dinning Area (500 sq ft) Zone 3 - 2nd Fl Bed Rooms (825 sq
ft)
1900 Total Sq Ft
Two stage, variable speed, 70k BTU furnace
Single stage, 2 ton A/C
Zone Pak Pro-3 Zone panel
(W2 initiated when the 2nd fl zone calls w/ any 1st fl zone)04/22/23 13ZONING SOLUTIONS
HPPro Zoning Data
Joe’s House
Data time range 16,522 min 275 hrs 11 days
Min ODT 19 deg f Max ODT 55 deg f Avg ODT 36 deg f
Total Run Time - 150 hrs 2nd stg Heat- W2 20 hrs 13%
Serving Zone 1 (1st fl Main) 111 hrs 74%Serving Zone 2 (1st fl kitch) 53 hrs 35% Serving Zone 3 (2nd fl Bd Rms) 36 hrs 24%
Serving Single Zone 72% Serving Two Zones 25% Serving All Three Zones 3%
W1 Cycle data Total cycles 589 Avg Cycle “On time” 16 MinAvg Cycle “Off time” 8 Min Avg Cycles/Hr 2
Joe’s House
Data time range 5 days
Min ODT 78 deg f Max ODT 91 deg f Avg ODT 84 deg f
Total Run Time - 39 hrs 2nd stg Blower- Y2 38 % (Y1 only 62%)
Serving Zone 1 (1st fl Main) 3 %Serving Zone 2 (1st fl kitch) 38 % Serving Zone 3 (2nd fl Bd Rms) 62 %
Serving Single Zone 70 % Serving Two Zones 29 % Serving All Three Zones 1 %
HPPro Zoning DataHPPro Zoning Data
04/22/23 15ZONING SOLUTIONS
BENEFITS OF ZONING
• Greater Occupant Comfort• Allows for Decreases in System Capacity
Demand• Increased Installation Flexibility• Reduced Energy Consumption
04/22/23 16ZONING SOLUTIONS
Two Zone Layout• 1st Fl Living area is 60% of the duct capacity• 2nd Fl Bed Room Zone is 40% of the duct capacity
2nd floor Bedroom Zone
40%
st floor Living Area 60%
04/22/23 17ZONING SOLUTIONS
Three Zone Layout• 1st Fl Living area is 50% of the duct capacity• 2nd Fl Master suite is 25% of the duct capacity• 2nd Fl Bed Rooms 1 & 2 are 25% of the duct capacity
Master Suite
25%
Bedroom 1
12%
Bedroom 2
13%1st floor Living Area
50%
04/22/23 18ZONING SOLUTIONS
SEGMENT 6 ZONING COMPONENTS
04/22/23 19ZONING SOLUTIONS
STANDARD ZONE PAK FEATURES
• 2 or 3 zones with one air handler• Controls integrate with any secondary heat
source• Reliable operation provided by Air-Driven
Dampers• Easy to install vinyl tubing
04/22/23 20ZONING SOLUTIONS
Reduced Energy Consumption
• Simple 24 Volt Wiring• Quiet Operation• Pre-Programmed Controls• Convenient Packaged Systems• Unmatched Factory Support
04/22/23 21ZONING SOLUTIONS
PLENUM DAMPER PACKAGES AVAILABLE
• 8" Square 2-Zone System• 8" Square 3-Zone System• 9" Round 2-Zone System• 9" Round 3-Zone System• SmartPak System 2-Zone System• SmartPak System 3-Zone System
04/22/23 22ZONING SOLUTIONS
PACKAGES INCLUDE
• Plenum Dampers• Control Panel• 24 Volt Transformer• Tubing• Cut-Out Templates
04/22/23 23ZONING SOLUTIONS
BRANCH DAMPERS
• 2" Branch Dampers - 2/pack• 2" Branch Dampers - 5/pack• Control Panel selected separately for 2 or 3
zones• Can be used in conjunction with plenum
dampers
04/22/23 24ZONING SOLUTIONS
ZONE PAK PRICE SHEET
04/22/23 25ZONING SOLUTIONS
Market Impact
• High efficiency equipment can be made even more efficient with the power of zoning.
• Airflow can be manipulated based on zone weight so we have a lesser need for bypass which impact actual delivered efficiency.
04/22/23 26ZONING SOLUTIONS
Market Impact• Humidity Control comfort is not just about
temperature. Humidity has a large impact on how comfortable we feel.
• The Zone Pak Pro™ provides systems for humidification and positive control of the bypass humidifier duct.
• The Zone Pak Pro™ allows you to run a dehumidification cycle using standard equipment. You no longer need equipment with a dedicated “Dehum” cycle. Fight moisture build up and mold in humid climates. Keep everyone more comfortable.
04/22/23 27ZONING SOLUTIONS
Market Impact
• Zoning makes any system more effective– This is especially true for heat pumps that can at times be
capacity limited. Concentrating the conditioned air to those areas that need heat or cool just makes sense.
• Staging on Capacity – Presently only the highest end equipment has the
capability to adjust its capacity based not only on thermostat demand but on equipment capacity. Space Pak has taken a large step toward making heat pumps an option for more areas of the country.
04/22/23 28ZONING SOLUTIONS
Market Impact• The Zone Pak Pro™ Steps out of the 20th century and
into the 21st.– It has been designed to give contractors abilitites that
have never been available before.– It has a great new look. The LCD screen makes a
statement to today’s tech savvy consumers– It is entirely software driven. There are no dip switches.
The adaptive program walk installers and technicians through with no confusion.
– Use ANY thermostats that make sense for your application. Zones 2-4 use only 4 or 5 wire heat/cool stats. New installers will have no problems with this unit.
04/22/23 29ZONING SOLUTIONS
SEGMENT 7ZONING RULES
04/22/23 30ZONING SOLUTIONS
Design ConsiderationsDesign Considerations
• Design DX systems with 2 or 3 zones max.Design DX systems with 2 or 3 zones max.– Unlimited with Chiller applicationsUnlimited with Chiller applications
• All zones must have a All zones must have a minimumminimum of 3.5 outlets per of 3.5 outlets per ton – (per zone)ton – (per zone)– 4 ton system4 ton system
• 4 x 3.5 = 14 outlets per zone minimum4 x 3.5 = 14 outlets per zone minimum• 3 zones x 14 outlets = 42 outlets total3 zones x 14 outlets = 42 outlets total• 42 outlets divided by 4 tons = 10 outlets/ton 42 outlets divided by 4 tons = 10 outlets/ton
• 2 zone systems can be designed with as high as 5 2 zone systems can be designed with as high as 5 outlets per ton per zone outlets per ton per zone (10/ton total outlets)(10/ton total outlets)
• Not recommended to use a bypass duct on DX Not recommended to use a bypass duct on DX coil systemscoil systems
04/22/23 31ZONING SOLUTIONS
Outlets Per Zone (per ton)
System Tonnage
Min/Outlets/
Zone
2 Zone
Min w/ Max
3 Zone
Min-Max
Total System Outlet Max
2 7 7 w/ 14 7 21
2.5 9 9 w/ 18 9 27
3 11 11 w/ 22 11 33
3.5 12-13 12 w/ 24 12 36
4 14 14 w/ 28 14 42
5 18 18 w/ 36 18 54
04/22/23 33ZONING SOLUTIONS
MD
MD
Zone 2
Dam
per
Zone 1Damper
RA
AH
3 ton 2 Zone (3 ton X 3.5 = 11 outlets per zone minimum)Z-1 = 15 Outlets (5/ton)Z-2 = 11 Outlets (3.5/ton min)26 outlets Total = 8.5 / Ton
Zone 2 Load requires 6 Outlets
Zone 1 Load requires 15 Outlets
04/22/23 34ZONING SOLUTIONS
MD
MDMD
2.5 ton/ 3 Zone2.5 ton X 3.5 / ton = 9 outlets / zone
27 Outlets Total = 10.5/Ton Duct sizes
Square – 8.5" x 8.5"Round
Common Trunk - 9"Zone Trunk - 7"
Zone 2Damper
Zone 3Damper
Zone 1Damper
RA
AH
2.5 ton/ 3 Zone (2.5 ton X 3.5 / ton = 9 outlets / zone)27 outlets Total = 10.5 / Ton
04/22/23 35ZONING SOLUTIONS
MD
MD
Zon
e 2D
amp
er
Zon
e 1D
amp
er
4 ton/ 2 Zone4 ton X 3.5 / ton = 14 outlets / zone
28 outlets equals 7/ton Total Optional – up to 5 Outlets/Ton/Zone
Duct sizesSquare
Trunk 9.5" x 9.5"Round
Common Trunk - 10"Zone Trunk - 7"
RA
AH
4 ton/ 2 Zone (4 ton X 3.5 / ton = 14 outlets / zone)28 outlets Total = 7 / Ton (2 Zone Option - 5 Outlets/Ton/Zone)
04/22/23 36ZONING SOLUTIONS
2.5 ton/ 2 Zone (2.5 ton X 3.5 / ton = 9 outlets / zone)18 outlets Total = 7 / Ton (2 Zone Option - 5 Outlets/Ton/Zone)
Duct sizesSquare – 8.5" x 8.5" (All Duct)RoundCommon Trunk - 9"Zone Trunk - 7"
RA
MD
MD
Zone 1Damper
Zone 1Damper
AH
MD
Zone 2Damper
MD
Zone 2Damper
04/22/23 37ZONING SOLUTIONS
Air Schematic
Com
N/O
N/C
Com
N/O
N/C
Vacuum Side of Pump
-30” to -40” WC
Pressure Side of Pump
40” to 50” WC
24 V DC Solenoid
+ + 1 2 3 4
24 VAC
24 V DC Solenoid
AirBoss-2 PC Brd
R
W1
W2
Y1
Y2
G
O
C
R
W1
W2
Y1
Y2
G
O
C
R W1 W2 Y1 Y2 G O B C
HVAC OUTPUT
ZONE SOLENOID
ZO
NE
1
ZO
NE
2
PUMP
N/O to Vacuum
N/C to Pressure
On
MPS
Off
To Zone 2 dampers
To Zone 1 dampers
De-energized 0 VDCEnergized 24 VDC
04/22/23 38ZONING SOLUTIONS
ALTERNATIVES TO INCREASING OUTLETS PER TON
1. FIND A DUMP ZONE2. INSTALL A TWO SPEED CONDENSER
1. MATCH AIR FLOW TO CONENSER SET BACK WITH ACM
3. INSTALL WITH A GEO WATER, CHILLER AND/OR BOILERS
04/22/23 39ZONING SOLUTIONS
Reverse-Acting Dump OutletsThe Alternative to Bypass CFM
• Add additional outlets to dump areas that are controlled by reverse acting dampers and open when larger zones close.– Be careful not to overdue it
04/22/23 40ZONING SOLUTIONS
Dump (static relief) Zone
MDMD
Zone 2Damper
Zone 3Damper
Zone 1Damper
RA
AH
MD
Rev ActDamper
Vaulted Ceiling AreaZone Panel
MD
04/22/23 41ZONING SOLUTIONS
Dump (static relief) Zone
MDMD
Zone 2Damper
Zone 3Damper
Zone 1Damper
RA
AH
MD
Rev ActDamper
Vaulted Ceiling AreaZone Panel
MD
04/22/23 42ZONING SOLUTIONS
ModuPass Damper
Spring Open/Pressure Closed Damper
04/22/23 43ZONING SOLUTIONS
ModuPass Bulkhead PortAvailable on Air Boss and Zone Pak Pro panels
Com
N/O
N/C
Vacuum Side of PumpPressure Side of Pump
+ + 1 2 3 4
24 VAC
24 V DC Solenoid
AirBoss-2 PC Brd
R
W1
W2
Y1
Y2
G
O
C
R
W1
W2
Y1
Y2
G
O
C
R W1 W2 Y1 Y2 G O B C
HVAC OUTPUT ZONE SOLENOID
ZO
NE
1
ZO
NE
2
PUMP
ModuPass Port
Connects to Pressure only
Zone 1 Solenoid Zone 2 Solenoid
04/22/23 44ZONING SOLUTIONS
Pressure TransmitterNormal Static Press
Pump Pressure @ 45”wc
.012” Restrictor
Pressure @ 45”wc
Supply Duct
H V Control1” to 2” Press range
Pressure Transmitter
04/22/23 45ZONING SOLUTIONS
Pressure TransmitterExcessive Static Press
Pump Pressure @ 45”wc
.012” Restrictor
Supply Duct
Variable Pressure 0” to 20”wc
Pressure Transmitter
Variable “Bleed-Off”
H V Control1” to 2” Press range
04/22/23 46ZONING SOLUTIONS
3 Zone with 6” Round Bypass Duct“On A chiller”
MDMD
Zone 2Damper
Zone 3Damper
Zone 1Damper
RA
AH
ModuPassDamper
Zone Panel
MD
MD
04/22/23 47ZONING SOLUTIONS
USING THE ACM TO SET BACK AND MATCH 2 SPEED CONDENSER
STEP # 1 – REFER TO THE CFM SET FOR MAXIMUMCONDENSER CAPACITY.
STEP # 2 – DETERMINE THE SET BACK CAPACITYOF THE CONDENSER. ALL MANUFACTURERSSET BACK A % OF TOTAL CAPACITY. SOMESET BACK 30%, 35%, 40% OR 50%.
STEP # 3 MULTIPLY THE TOTAL CFM FOR MAXIMUM CAPACITY BY THE % SET BACK. THIS WILL GIVE YOU A CFM TO SUBTRACT FROM THE TOTAL.
STEP # 4 SUBTRACT THE % CFM FROM STEP 3 FROM THE TOTAL.STEP # 5 FIND THE SET BACK CFM ON THE ACM AMP CHARTSTEP # 6 SET THE ACM BY READING AMPS TO THE MINIMUM POSITION.
04/22/23 48ZONING SOLUTIONS
Market impact
• Programmability– The Setup Wizard walks the installer through a series
of very simple setup parameters. – The setup worksheet gives the installation manager or
Comfort consultant an easy way to tell installers just how they want the system to be configured.
– Once the Setup Wizard is complete the parameters are “burned” into non-volatile memory. Loosing power will not reset your settings.
04/22/23 49ZONING SOLUTIONS
ZONEPAK PRO PANEL
04/22/23 50ZONING SOLUTIONS
ZONE PAK PRO
04/22/23 51ZONING SOLUTIONS
Setup Wizard
• The first time the system is powered up the Installer must run through all of the Setup questions. This sets all of the default settings.
• Subsequent times if no changes are made in 30 seconds the system will power up using it’s current default settings
04/22/23 52ZONING SOLUTIONS
ZONEPAK PRO PANEL
04/22/23 53ZONING SOLUTIONS
Stage on Demand
• The Zone Pak Pro™ accepts two-stage inputs from the Zone 1 thermostat.
• Demand will be recognized and served.
04/22/23 54ZONING SOLUTIONS
Stage on Capacity• Heat pumps provide a finite
amount of heat or cool in any given operating mode.
• This graph shows a simple single-stage scenario. – Call starts – ∆T (the change in temperature
over any given time) increases rapidly as the refrigerant starts to circulate
– ∆T starts to decrease, finally going to zero as the equipment capacity is reached.
04/22/23 55ZONING SOLUTIONS
Zone Pak Pro PanelZone Pak Pro PanelCapacity StagingCapacity Staging
Heating cycle initiated
2nd stage Heat initiated
Heating cycle reaches “Steady State” LAT above “Min heating LAT” setting
Pre-Set LAT Min (Leaving Air Temp Minimum)
3rd stage Heat initiated
04/22/23 56ZONING SOLUTIONS
Zone Weighting
• Zone weighting gives The Zone Pak Pro™ several distinct advantages– We are able to stage up the air
handler independently of the condenser based on the amount of ductwork being served. This reduces or eliminates the need to bypass increasing system effectiveness.
– Priority can be based on the cumulative zone weight calling for any particular service.
04/22/23 57ZONING SOLUTIONS
Air Handler Control
• Staging the Air Handler(s) independently from the condensers gives us a very powerful tool to affect comfort.
• Only stage up the Air Handler when there is enough ductwork open to accept the air provided.– Throttle back the air handler for
dehumidification.• Controlling fan speed provides
another tool for customizing your customers’ comfort.– Provides warmer air delivery to
single zone callers.• Reduce or Eliminate the need for
bypass.
2 Stg Heat Pump
Air Handler/ V spd Furnace
Y1 Y2
YI Y2 Y1 Y2 CAir Handler Condenser
HPP HVAC outputY1 Y2 C
HPPro
Humidification
• On a call from a humidistat:– Send a 24VAC signal to
the humidifier– Open a damper in the
humidifier bypass ductwork
• Eliminates the homeowner’s need to open or close a manual damper
04/22/23 59ZONING SOLUTIONS
Dehumidification
• Standard Equipment– On a call from a
Dehumidistat:• If cooling back off one
cooling speed setting• If not cooling start the
condenser and low speed fan
• Run the system on and off on a user defined cycle period.
– Inhibited during heating cycles
• Lennox Signature/Carrier Infinity– Pass the call to the proprietary
equipment– Inhibited during heating cycles
The Zone Pak Pro™ has the ability to operate as a whole house dehumidifier.
04/22/23 60ZONING SOLUTIONS
Built-In Controls• Balance Point Calculations – no need for an outdoor
thermostat.• Resistance Heat Lockout control holds off resistance
heat above a given temperature to comply with utility regulations or incentive programs
• Low-ambient cooling – no need for a low-ambient kit, ZPP inhibits cooling below an adjustable temperature automatically.
• Outdoor Reset Controls – adjusts Leaving Air Temperature requirements as outside air temperature changes.
• Leaving Air Controls – protects HVAC equipment04/22/23 61ZONING SOLUTIONS
Leaving Air Temperature SensorHeating
• Protects the HVAC Equipment from extreme temperatures
• Heating LAT trips 2nd stage 10oF below setpoint*, and the 1st Stage at setpoint.
•1st stage is reconnected on a temperature fall of 15o and 4 minute off-time.
•Up staging is inhibited within 15o of the setpint
•Calls that contain a W will use the Backup Heat LAT Setting
*The LAT System is a secondary control. It should be set inside factory limits.
04/22/23 62ZONING SOLUTIONS
Leaving Air Temperature SensorCooling
• Protects the coil from freezing
• Cooling LAT trips 2nd stage 5oF above setpoint*, and the 1st Stage at setpoint.
•1st Stage is reconnected after a temperature rise of 10o and 4 min off-time.
•Up staging is inhibited within 10o of the setpoint
*The LAT System is a secondary control. It should be set inside factory limits.
04/22/23 63ZONING SOLUTIONS
Equipment Integration
• The Zone Pak Pro™ has been designed with all the features you need to control virtually any heat pump.– All Electric– Dual Fuel– Geothermal
04/22/23 64ZONING SOLUTIONS
Thermostats
• Zone 1 – Use any thermostat that provides the features you need. Heat/cool or Heat pump, single or two-stage, wired or wireless. You can use the thermidistats, anything that gives you the control you want.
• Zones 2-4 Use simple 4 or 5 wire heat cool thermostats. This simplifies installation and planning.
04/22/23 65ZONING SOLUTIONS
Software Driven
• The key to the flexibility and adaptive nature of the Zone Pak Pro™ is the fact that it is 100% software driven. – Most settings and timers are field adjustable – System changes and upgrades can be sent by
email– System will be more end-user friendly
04/22/23 66ZONING SOLUTIONS
Set up Wizard zpp
04/22/23 67ZONING SOLUTIONS
The Setup Worksheet
Prompt Description Setting
1 Zone 1 - Thermostat TypeHeat pump or Heat/Cool - defines how input sigals will be interpreted.
2 Zone 1 - Thermostat Weight
Assigns a relative weight for each zone. Can be for 10% to 90%. Determines when the air handler stages up. Zone 1
3 Zone 2 - Thermostat Weight Zone 2
4 Zone 3 - Thermostat Weight Zone 3
5 Zone 4 - Thermostat Weight Zone 4
6 Minimum HeatDefines the minimum acceptable temperature for the LEAVING Air Tempeature during a heating call
7 Maximum CoolDefines the maximum acceptable temperature for the LEAVING Air Tempeature during a cooling call
8 Back-up TypeEll the HPP what equipment it will be working with. Electric strips or Fossil Fuel
9 Balance PointEnter the temperature you want to change over to Fossil Fuel Backup furnace.
10 Heat Strip Lock-outEnter the temperature above which you do NOT want heat strips to be turned on.
11 Min OAT for CoolingBuilt-in Low Ambient Kit. Set temperature below which you do NOT want cooling
12 Low LAT LimitLow Limit for Leaving Air Temperature. Set temperature to shut down the 1st stage compressor
13 High LAT LimitHigh Limit for Leaving Air Temperature. Set temperature to shut down the 1st stage compressor
14 High LAT Limit with W High LAT Limit for backup heat system
15 Cool O/BSet which cycle energizes reversing valve. Defualt is "O" O/B Terminal will be hot for a cooling call
16 Staging ThresholdSet % weight that will allow airhandler to stage up with compressors.
Zone Pak Pro™ Setup Worksheet
04/22/23 68ZONING SOLUTIONS
Apply the Template
04/22/23 69ZONING SOLUTIONS
Cut out the Triangle
04/22/23 70ZONING SOLUTIONS
Insert the Damper
04/22/23 71ZONING SOLUTIONS
Twist into Position
04/22/23 72ZONING SOLUTIONS
Fasten with Zip Screws
04/22/23 73ZONING SOLUTIONS
Attach the Air Line
04/22/23 74ZONING SOLUTIONS
Finished!
04/22/23 75ZONING SOLUTIONS