  • Electrosurgical Unit

    ZERO50 Specification

    ZE

    RO

    50

    Rated Voltage AC120V or AC230V

    Rated Frequency 50Hz or 60Hz

    Power Consumption 150VA +10%

    Fuse T2.0AL when AC120V or T1.0AL when AC230V

    Protection class Class 1, Type BF

    Leakage current in acc. with IEC601,Part2-2

    Carrier Frequency 1.6MHz

    Repeat Frequency 100Hz / 120Hz

    Size (W×D×H) 200mm × 220mm × 90mm

    Weight 2.6Kg

    Operation Cycle 10sec ON 30sec Idle

    Specification

    Using Environment

    Operation temperature 10℃ to 40℃

    Storage temperature -10℃ to 60℃

    Humidity 20% to 95% RH,

    Operation altitude 700mbar ~ 1060mbar

    Mode Output Power Carrier Freg. Crest Factors Duty Rate

    Cut 50W / 300Ω 1.6MHz 2.1 100%

    Coagulation 40W / 300Ω 1.6MHz 2.3 30%

    Output Power

  • Electrosurgical Unit

    Standard Accessories

    Silicone patient plate

    (PL02-03R)

    ZE

    RO

    50

    Disposable twin button handle

    (HD02-01D)

    Optional AccessoriesKnife Electrode (EL01-01D)

    Ball Electrode (EL02-01D)

    Needle Electrode (EL04-01D)

    Needle Electrode Angled (EL04-02D)

    Power Cord

    (CA04-01R)

  • Electrosurgical Unit

    Feature

    ZE

    RO

    50 ① This provides necessary functions like Pure Cut, Coagulation, Under operation by one equipment

    ② Twin Button Handles provide remote-control function.(Select Cutting or Coagulation)

    ③ When cut, coagulation or functioning, it can be recognized by the mark light.

    Safety Function

    ① A fuse built in a power circuit prevent an over current from flowing through the equipment.

    ② It protects patient safely by grounding the whole case and letting the leakage electric current flow on the ground which can flow into patient.

    ④ The equipment has an Analog slide switch by which the user can set print function for cut and coagulationeasily and safely.

  • ZEUS-100/80

    ZERONE CO., LTD.

  • Electrosurgical Unit

    ZEUS-100/80 Specification

    ZE

    US

    -10

    0/8

    0

    ZEUS-100 ZEUS-80

    Rated Voltage AC120V or AC230V

    Rated Frequency 50Hz or 60Hz

    Power Consumption 300VA +10% 270VA +10%

    Fuse T4.0AL when AC120V or T2.0AL when AC230V

    Protection class Class 1, Type BF

    Leakage current in acc. with IEC601,Part2-2

    Carrier Frequency 1.6MHz

    Repeat Frequency 100Hz / 120Hz

    Size (W×D×H) 270mm × 310mm × 110mm

    Weight 6Kg

    Using Environment

    Operation temperature 10℃ to 40℃

    Storage temperature -10℃ to 60℃

    Humidity 20% to 95% RH,

    Operation altitude 700mbar ~ 1060mbar

    Operation Cycle 10sec ON 30sec Idle

    Specification

  • Electrosurgical Unit

    Mode Output Power

    Carrier Freg. Crest Factors Duty RateZEUS-100 ZEUS-80

    Pure Cut 100W / 300Ω 80W / 300Ω 1.6MHz 1.6 100%

    Blend 100W / 300Ω 80W / 300Ω 1.6MHz 2.2 60%

    Contact Coagulation 60W / 300Ω 50W / 300Ω 1.6MHz 2.5 30%

    Bipolar Coagulation 80W / 100Ω 70W / 100Ω 1.6MHz 1.6 100%

    ZE

    US

    -10

    0/8

    0

    Output Power

    Standard Accessories

    Silicone patient plate

    (PL02-02R)

    Single foot switch

    (FS01-01R)

    Knife Electrode (EL01-01D)

    Twin Button handle

    (HD02-01D)

    Ball Electrode (EL02-01D)

    Needle Electrode (EL04-01D)

    Needle Electrode Angled (EL04-02D)

    Power Cord

    (CA04-01R)

  • Electrosurgical Unit

    Optional AccessoriesZ

    EU

    S-1

    00

    /80

    Straight 9.0cm 0.5 Tip (BF02-01R)

    Angled 9.0cm 0.5 Tip (BF03-01R)

    Straight 12.1cm 1.0 Tip (BF02-02R)

    Straight 17.8cm 1.0 Tip (BF02-03R)

    Angled 17.8cm 1.0 Tip (BF02-03R)

    Bayonet 15.2c m 1.0 Tip (BF01-02R)

    Disposable return

    patient plate

    (PL03-02D)

    Bipolar forceps cable

    (CA01-01R)

    Bayonet 17.8cm 1.0Tip

    (BF01-01R)

    Return patient plate

    Cable (CA02-02R)

    Monopolar handle

    (CA02-01R)

    Cart (CT01-01R)

  • Electrosurgical Unit

    Feature

    ① A DISPLAY window allows you to easily check output values, indicated as digits.

    ② This provides necessary functions like Pure Cut, Blend, Contact Coagulation, Bipoar Coagulation, under operation by one equipment

    ③ Holding the button for each mode for more than 3 seconds, the output ratio on Display will be changed to 1W to befacilitated to shift from the low to high output.

    ④ Twin Button Handles provide remote-control function. (Select Cutting or Coagulation)

    ⑤ Foot Switch is available for Cutting and Coagulating.

    ⑥ Bipolar coagulation of by Foot Switch.

    ⑦ Microprocessor can straighten, stabilize the output.

    ⑧ Operations of Cutting, Coagulation and Bipolar Coagulation can be distinct from each other by sound and indication lamp.

    ⑨ Each application mode (Cutting, Coagulation, Bipolar Coagulation) has a different sound, which enables you to easilydistinguish an operation type.

    ⑩ If the area between a patient and the pad is not appropriate, REM(Return Electrode Monitoring) gives the alarm with awarning sound and stop an operation of the product to prevent a burning incident.

    ⑪ The selected output ratio of Cut, Coagulation, and Bipolar Coagulation will displayed by reenergizing the device after power OFF.

    ZE

    US

    -10

    0/8

    0

  • Electrosurgical Unit

    Safety Function

    ① A fuse built in a power circuit prevent an over current from flowing through the equipment.

    ZE

    US

    -10

    0/8

    0

    ③ REM (Return Electrode Monitoring) monitors the size of contacting area between a patient and the pad. If the size isinappropriate, it automatically blocks the high- frequency current to minimize the danger of burning incidents.

    ② When the plate attached to the patient is separated from the equipment, the red alarm light begins flickering. Pressing the button of Twin Button Handle or pedal of Foot Switch will stop the alarm sound and the equipment.

    ④ To protect a patient, the case is fully grounded so that a leakage current can flow into the earth.

  • ZEUS-200S/150

    ZERONE CO., LTD.

  • Electrosurgical Unit

    ZEUS-200S/150 Specification

    ZE

    US

    -20

    0S

    /15

    0

    ZEUS-200S ZEUS-150

    Rated Voltage AC120V or AC230V

    Rated Frequency 50Hz or 60Hz

    Power Consumption 650VA +10% 550VA +10%

    Fuse T6.3AL when AC120V or T4.0AL when AC230V

    Protection class Class 1, Type CF

    Leakage current in acc. with IEC601,Part2-2

    Carrier Frequency 400㎑, 500㎑

    Repeat Frequency 33㎑

    Size (W×D×H) 330mm × 330mm × 135mm

    Weight 8Kg

    Using Environment

    Operation temperature 10℃ to 40℃

    Storage temperature -10℃ to 60℃

    Humidity 20% to 95% RH,

    Operation altitude 700mbar ~ 1060mbar

    Operation Cycle 10sec ON 30sec Idle

    Cooling 1 inner fan

    Specification

  • Mode Output Power

    Carrier

    Freg.

    Crest

    Factors

    Duty

    Rate

    Repeat

    Freq.ZEUS-200S ZEUS-150

    Pure Cut 200W / 200Ω 150W / 200Ω 400㎑ 1.7 100% Continuous

    Blend1 150W / 200Ω 120W / 200Ω 400㎑ 2.0 67% 33 ㎑

    Blend2 120W / 200Ω 100W / 200Ω 400㎑ 2.7 42%33 ㎑

    Contact Coagulation 80W / 200Ω 80W / 200Ω 400㎑ 2.6 25%33 ㎑

    Spray Coagulation 80W / 500Ω 60W / 500Ω 400㎑ 4.4 17%33 ㎑

    Bipolar Coagulation 80W / 100Ω 80W / 100Ω 500㎑ 2.0 100% Continuous

    Electrosurgical Unit

    ZE

    US

    -20

    0S

    /15

    0 Output Power

  • Electrosurgical Unit

    Standard Accessories

    Double foot switch

    (FS02-01R)

    Disposable twin button handle

    (HD02-01D)

    Return patient plate cable

    (CA02-02R)

    Monopolar handle

    (HD01-01R)

    Bipolar forcep cable

    (CA01-01R)

    Disposable return patient

    Plate ( PL03-02D)

    Bayonet 17.8cm 1.0Tip (BF01-01R)

    ZE

    US

    -20

    0S

    /15

    0

    Silicone patient plate

    (PL02-01R)

    Knife Electrode (EL01-01D)

    Ball Electrode (EL02-01D)

    Needle Electrode (EL04-01D)

    Needle Electrode Angled (EL04-02D)

    Loop Electrode (EL03-01D)

    Power Cord

    (CA04-01R)

  • Electrosurgical Unit

    Optional AccessoriesStraight 9.0cm 0.5 Tip (BF02-01R)

    Angled 9.0cm 0.5 Tip (BF03-01R)

    Straight 12.1cm 1.0 Tip (BF02-02R)

    Straight 17.8cm 1.0 Tip (BF02-03R)

    Angled 17.8cm 1.0 Tip (BF02-03R)

    Bayonet 15.2c m 1.0 Tip (BF01-02R)

    ZE

    US

    -20

    0S

    /15

    0

    Cart

    (CT01-01R)

  • Electrosurgical Unit

    Feature

    ① A DISPLAY window allows you to easily check output values, indicated as digits.

    ⑤ Automatic selection of input power frequency 50Hz / 60HZ

    ④ Freely switch of Auto Mode/Manual selection.

    ⑥ Holding the button for each mode for more than 3 seconds, the output ratio on Display will be changed to 1W to be facilitated to shift from the low to high output.

    ZE

    US

    -20

    0S

    /15

    0

    ② One equipment provides such functions that are required to perform an operation as Functional Cutting (Pure Cut,Blend1, Blend2), Coagulation (Spray Coagulation, Contact Coagulation), Bipolar Coagulation.

    ③ Auto Mode function- Without separate selection of Cut and Coagulation button, it is available the Cut and Coagulation only with

    Twin Button Handle and Double Foot Switch.

    - Switch over display between set Cut and Coagulation output value.

    ⑦ Equipped with large FND, good visualization from long distance. A display window Allows You to easily check outputvalues, indicated as digits.

    ⑧ Foot Switch is available for Cutting and Coagulating.

    ⑨ Bipolar coagulation of by Foot Switch.

    ⑩ Microprocessor can straighten, stabilize the output.

    ⑪ Operations of Cutting, Coagulation and Bipolar Coagulation can be distinct from each other by sound and indication lamp.

    ⑫ Each application mode (Cutting, Coagulation, Bipolar Coagulation) has a different sound, which enables you to easilydistinguish an operation type.

    ⑬ If the area between a patient and the pad is not appropriate, REM(Return Electrode Monitoring) gives the alarm with awarning sound and stop an operation of the product to prevent a burning incident.

    ⑭ The level of alarm sound can be adjusted during an operation of application mode.

    ⑮ The selected output ratio of Cut, Coagulation, and Bipolar Coagulation will displayed by reenergizing the device afterpower OFF.

  • Electrosurgical Unit

    Safety Function

    ① A fuse built in a power circuit prevent an over current from flowing through the equipment.

    ③ REM (Return Electrode Monitoring) monitors the size of contacting area between a patient and the pad. If the size isinappropriate, it automatically blocks the high- frequency current to minimize the danger of burning incidents.

    ④ To protect a patient, the case is fully grounded so that a leakage current can flow into the earth.

    ZE

    US

    -20

    0S

    /15

    0

    ② When the plate attached to the patient is separated from the equipment, the red alarm light begins flickering.Pressing the button of Twin Button Handle or the pedal of Cutting and Coagulation of Double Foot Switch will

    stop the alarm sound and the equipment.

  • ZEUS-400/300/200

    ZERONE CO., LTD.

  • Electrosurgical Unit

    ZEUS-400/300/200 SpecificationZ

    EU

    S-4

    00

    /30

    0/2

    00

    ZEUS-400 ZEUS-300 ZEUS-200

    Rated Voltage AC120V or AC230V

    Rated Frequency 50Hz or 60Hz

    Power Consumption 1200VA +10% 1100VA +10% 1000VA +10%

    Fuse T10AH when AC120V or T6.3AL when AC230V

    Protection class Class 1, Type CF

    Leakage current in acc. with IEC601,Part2-2

    Carrier Frequency 400㎑, 500㎑

    Repeat Frequency 33㎑

    Size (W×D×H) 330mm × 455mm × 150mm

    Weight 13Kg

    Using Environment

    Operation temperature 10℃ to 40℃

    Storage temperature -10℃ to 60℃

    Humidity 20% to 95% RH,

    Operation altitude 700mbar ~ 1060mbar

    Operation Cycle 10sec ON 30sec Idle

    Cooling 1 inner fan

    Specification

  • Mode Output Power

    Carrier

    Freg.

    Crest

    Factors

    Duty

    Rate

    Repeat

    Freq.ZEUS-400 ZEUS-300 ZEUS-200

    Pure Cut 400W / 300Ω 300W / 300Ω 200W / 300Ω 400㎑ 1.6 100% Continuous

    Blend1 250W / 300Ω 230W / 300Ω 150W / 300Ω 400㎑ 2.0 80% 33 ㎑

    Blend2 200W / 300Ω 180W / 300Ω 120W / 300Ω 400㎑ 2.2 60% 33 ㎑

    Blend3 150W / 300Ω 120W / 300Ω 100W / 300Ω 400㎑ 2.4 50% 33 ㎑

    Contact Coagulation 120W / 300Ω 100W / 300Ω 100W / 300Ω33~153

    ㎑3.3~1.5 100%

    pulse

    modulated

    Spray Coagulation 100W / 300Ω 80W / 300Ω 80W / 300Ω 400㎑ 4.5 8.0% 33 ㎑

    Bipolar Coagulation 99W / 100Ω 80W / 100Ω 80W / 100Ω 500㎑ 1.5 100% Continuous

    Electrosurgical Unit

    ZE

    US

    -40

    0/3

    00

    /20

    0

    Output Power

  • Electrosurgical Unit

    Standard Accessories

    Ground Cable

    (CA03-01R)

    Single foot switch

    (FS01-02R)

    ZE

    US

    -40

    0/3

    00

    /20

    0

    Double foot switch

    (FS02-01R)

    Disposable twin button

    Handle (HD02-01D)

    Return patient plate

    cable (CA02-02R)

    Monopolar handle

    (HD01-01R)

    Bipolar forcep cable

    (CA01-01R)

    Disposable return patient

    Plate ( PL03-02D)

    Bayonet 17.8cm 1.0Tip (BF01-01R)

    Silicone patient plate

    (PL02-01R)

    Knife Electrode (EL01-01D)

    Ball Electrode (EL02-01D)

    Needle Electrode (EL04-01D)

    Needle Electrode Angled (EL04-02D)

    Loop Electrode (EL03-01D)

    Power Cord

    (CA04-01R)

  • Accessories

    MODEL

    ZEUS-400 ZEUS-300 ZEUS-200

    Double foot switch (FS02-01R) O O O

    Single foot switch (FS01-02R) O O O

    Disposable twin button handle (HD02-01D) O O O

    Monopolar handle (HD01-01R) O O O

    Return patient plate cable (CA02-02R) O O O

    Silicone patient plate (PL02-01R) O O O

    Bipolar forcep cable (CA01-01R) O O O

    Ground Cable (CA03-01R) O O X

    Bayonet 17.8cm 1.0Tip (BF01-01R) O O O

    Disposable return patient Plate ( PL03-02D) O O O

    Knife Electrode (EL01-01D) O O O

    Needle Electrode (EL04-01D) O O O

    Needle Electrode Angled (EL04-02D) O O O

    Ball Electrode (EL02-01D) O O O

    Loop Electrode (EL03-01D) O O O

    Electrosurgical Unit

    ZE

    US

    -40

    0/3

    00

    /20

    0 Standard Accessories

  • Electrosurgical Unit

    Optional Accessories

    Straight 9.0cm 0.5 Tip (BF02-01R)

    Angled 9.0cm 0.5 Tip (BF03-01R)

    Straight 12.1cm 1.0 Tip (BF02-02R)

    Straight 17.8cm 1.0 Tip (BF02-03R)

    Angled 17.8cm 1.0 Tip (BF02-03R)

    Bayonet 15.2c m 1.0 Tip (BF01-02R)

    ZE

    US

    -40

    0/3

    00

    /20

    0

    Cart

    (CT01-01R)

  • Electrosurgical Unit

    Feature

    ① A DISPLAY window allows you to easily check output values, indicated as digits.

    ⑩ Holding the button for each mode for more than 3 seconds, the output ratio on Display will be changed to 1W to be facilitated to shift from the low to high output.

    ② One equipment provides such functions that are required to perform an operation as Functional Cutting (Pure Cut,Blend1, Blend2, Blend3), Coagulation (Spray Coagulation, Contact Coagulation), Bipolar Coagulation (Hand Bipolar,

    Foot Bipolar).

    ⑧ Each application mode (Cutting, Coagulation, Bipolar Coagulation) has a different sound, which enables you to easilydistinguish an operation type.

    ⑨ If the area between a patient and the pad is not appropriate, REM(Return Electrode Monitoring) gives the alarm with awarning sound and stop an operation of the product to prevent a burning incident.

    ⑪ The level of alarm sound can be adjusted during an operation of application mode.

    ⑫ The selected output ratio of Cut, Coagulation, and Bipolar Coagulation will displayed by reenergizing the device afterpower OFF.

    ③ Two Twin Button Handles provide remote-control function. (Select Cutting or Coagulation)

    ④ Foot Switch is available for Cutting and Coagulating.

    ⑤ Hand Bipolar(Auto Bipolar) can be used only by contacting Forceps.

    ⑥ Microprocessor can straighten, stabilize the output.

    ⑦ Operations of Cutting, Coagulation and Bipolar Coagulation can be distinct from each other by sound and indication lamp.

    ZE

    US

    -40

    0/3

    00

    /20

    0

  • Electrosurgical Unit

    Safety Function

    ① A fuse built in a power circuit prevent an over current from flowing through the equipment.

    ③ REM (Return Electrode Monitoring) monitors the size of contacting area between a patient and the pad. If the size isinappropriate, it automatically blocks the high- frequency current to minimize the danger of burning incidents.

    ④ To protect a patient, the case is fully grounded so that a leakage current can flow into the earth.

    ② When the plate attached to the patient is separated from the equipment, the red alarm light begins flickering.Pressing the button of Twin Button Handle or the pedal of Cutting and Coagulation of Double Foot Switch will

    stop the alarm sound and the equipment.

    ZE

    US

    -40

    0/3

    00

    /20

    0

  • ZEUS-400PLUS

    ZERONE CO., LTD.

    ZEUS-300PLUSZEUS-200PLUS

  • Electrosurgical Unit

    ZEUS-400P/300P/200P Specification

    ZE

    US

    -40

    0P

    /30

    0P

    /20

    0P

    ZEUS-400P ZEUS-300P ZEUS-200P

    Rated Voltage AC120V or AC230V

    Rated Frequency 50Hz or 60Hz

    Power Consumption 1200VA +10% 1100VA +10% 1000VA +10%

    Fuse T10AH when AC120V or T6.3AL when AC230V

    Protection class Class 1, Type CF

    Leakage current in acc. with IEC601,Part2-2

    Carrier Frequency 400㎑, 500㎑

    Repeat Frequency 33㎑

    Size (W×D×H) 330mm × 455mm × 150mm

    Weight 13Kg

    Using Environment

    Operation temperature 10℃ to 40℃

    Storage temperature -10℃ to 60℃

    Humidity 20% to 95% RH,

    Operation altitude 700mbar ~ 1060mbar

    Operation Cycle 10sec ON 30sec Idle

    Cooling 1 inner fan

    Specification

  • Mode Output Power

    Carrier

    Freg.

    Crest

    Factors

    Duty

    Rate

    Repeat

    Freq.ZEUS-400P ZEUS-300P ZEUS-200P

    Pure Cut 400W / 300Ω 300W / 300Ω 200W / 300Ω 400㎑ 1.6 100% Continuous

    Blend1 250W / 300Ω 230W / 300Ω 150W / 300Ω 400㎑ 2.0 80% 33 ㎑

    Blend2 200W / 300Ω 180W / 300Ω 120W / 300Ω 400㎑ 2.2 60% 33 ㎑

    Blend3 150W / 300Ω 120W / 300Ω 100W / 300Ω 400㎑ 2.4 50% 33 ㎑

    Contact Coagulation 120W / 300Ω 100W / 300Ω 100W / 300Ω33~153

    ㎑3.3~1.5 100%

    pulse

    modulated

    Spray Coagulation 100W / 300Ω 80W / 300Ω 80W / 300Ω 400㎑ 4.5 8.0% 33 ㎑

    Bipolar Coagulation 100W / 100Ω 80W / 100Ω 80W / 100Ω 500㎑ 1.5 100% Continuous

    Bipolar Cut 100W / 200Ω 80W / 200Ω 80W / 200Ω 500㎑ 1.5 100% Continuous

    Electrosurgical Unit

    ZE

    US

    -40

    0P

    /30

    0P

    /20

    0P

    Output Power

  • Electrosurgical Unit

    Standard Accessories

    Ground Cable

    (CA03-01R)

    Single foot switch

    (FS01-02R)

    ZE

    US

    -40

    0P

    /30

    0P

    /20

    0P

    Double foot switch

    (FS02-01R)

    Disposable twin button handle

    (HD02-01D)

    Return patient plate

    cable (CA02-02R)

    Monopolar handle

    (HD01-01R)

    Bipolar forcep cable

    (CA01-01R)

    Disposable return patient

    Plate ( PL03-02D)

    Bayonet 17.8cm 1.0Tip (BF01-01R)

    Silicone patient plate

    (PL02-01R)

    Knife Electrode (EL01-01D)

    Ball Electrode (EL02-01D)

    Needle Electrode (EL04-01D)

    Needle Electrode Angled (EL04-02D)

    Loop Electrode (EL03-01D)

    Power Cord

    (CA04-01R)

  • Accessories

    MODEL

    ZEUS-400P ZEUS-300P ZEUS-200P

    Double foot switch (FS02-01R) O O O

    Single foot switch (FS01-02R) O O O

    Disposable twin button handle (HD02-01D) O O O

    Monopolar handle (HD01-01R) O O O

    Return patient plate cable (CA02-02R) O O O

    Silicone patient plate (PL02-01R) O O O

    Bipolar forcep cable (CA01-01R) O O O

    Ground Cable (CA03-01R) O O X

    Bayonet 17.8cm 1.0Tip (BF01-01R) O O O

    Disposable return patient Plate ( PL03-02D) O O O

    Knife Electrode (EL01-01D) O O O

    Needle Electrode (EL04-01D) O O O

    Needle Electrode Angled (EL04-02D) O O O

    Ball Electrode (EL02-01D) O O O

    Loop Electrode (EL03-01D) O O O

    Electrosurgical Unit

    ZE

    US

    -40

    0P

    /30

    0P

    /20

    0P Standard Accessories

  • Electrosurgical Unit

    Optional Accessories

    Straight 9.0cm 0.5 Tip (BF02-01R)

    Angled 9.0cm 0.5 Tip (BF03-01R)

    Straight 12.1cm 1.0 Tip (BF02-02R)

    Straight 17.8cm 1.0 Tip (BF02-03R)

    Angled 17.8cm 1.0 Tip (BF02-03R)

    Bayonet 15.2c m 1.0 Tip (BF01-02R)

    ZE

    US

    -40

    0P

    /30

    0P

    /20

    0P

    Cart

    (CT01-01R)

  • Electrosurgical Unit

    Feature

    ① A DISPLAY window allows you to easily check output values, indicated as digits.

    ⑩ Holding the button for each mode for more than 3 seconds, the output ratio on Display will be changed to 1W to be facilitated to shift from the low to high output.

    ② One equipment provides such functions that are required to perform an operation as Functional Cutting (Pure Cut,Blend1, Blend2, Blend3), Coagulation (Spray Coagulation, Contact Coagulation), Bipolar Coagulation (Bipolar Cut,

    Hand Bipolar, Foot Bipolar).

    ⑧ Each application mode (Cutting, Coagulation, Bipolar Coagulation) has a different sound, which enables you to easilydistinguish an operation type.

    ⑨ If the area between a patient and the pad is not appropriate, REM(Return Electrode Monitoring) gives the alarm with awarning sound and stop an operation of the product to prevent a burning incident.

    ⑪ The level of alarm sound can be adjusted during an operation of application mode.

    ⑫ The selected output ratio of Cut, Coagulation, and Bipolar Coagulation will displayed by reenergizing the device afterpower OFF.

    ③ Two Twin Button Handles provide remote-control function. (Select Cutting or Coagulation)

    ④ Foot Switch is available for Cutting and Coagulating.

    ⑤ Hand Bipolar(Auto Bipolar) can be used only by contacting Forceps.

    ⑥ Microprocessor can straighten, stabilize the output.

    ⑦ Operations of Cutting, Coagulation and Bipolar Coagulation can be distinct from each other by sound and indication lamp.ZE

    US

    -40

    0P

    /30

    0P

    /20

    0P

    ⑬ 10 storages are available by using user storage function.

    ⑭ The input power frequency 50Hz / 60Hz is automatically detected.

    ⑮ It can be used by selecting the monopolar output (M1, M2).

  • Electrosurgical Unit

    Safety Function

    ① A fuse built in a power circuit prevent an over current from flowing through the equipment.

    ③ REM (Return Electrode Monitoring) monitors the size of contacting area between a patient and the pad. If the size isinappropriate, it automatically blocks the high- frequency current to minimize the danger of burning incidents.

    ④ To protect a patient, the case is fully grounded so that a leakage current can flow into the earth.

    ② When the plate attached to the patient is separated from the equipment, the red alarm light begins flickering.Pressing the button of Twin Button Handle or the pedal of Cutting and Coagulation of Double Foot Switch will

    stop the alarm sound and the equipment.

    ZE

    US

    -40

    0P

    /30

    0P

    /20

    0P

  • ZEUS Vision

    ZERONE CO., LTD.

  • Electrosurgical Unit

    ZEUS Vision Specification

    ZE

    US

    Vis

    ion

    Rated Voltage AC120V or AC230V

    Rated Frequency 50Hz or 60Hz

    Power Consumption 1200VA +10%

    Fuse T10AH when AC120V or T6.3AL when AC230V

    Protection class Class 1, Type CF

    Leakage current in acc. with IEC601,Part2-2

    Carrier Frequency 400㎑, 500㎑

    Repeat Frequency 33㎑

    Size (W×D×H) 388mm × 410mm × 160mm

    Weight 12.5Kg

    Using Environment

    Operation temperature 10℃ to 40℃

    Storage temperature -10℃ to 60℃

    Humidity 20% to 95% RH,

    Operation altitude 700mbar ~ 1060mbar

    Operation Cycle 10sec ON 30sec Idle

    Cooling 1 inner fan

    Specification

  • Electrosurgical Unit

    ZE

    US

    Vis

    ion

    Mode Output Power Carrier Freg.Crest

    Factors

    Duty

    Rate

    Repeat

    Freg.

    Pure Cut 400W / 200Ω 400kHz 1.6 100% Continuous

    Blend1 250W / 200Ω 400kHz 2.4 70% 33kHz

    Blend2 200W / 200Ω 400kHz 2.3 55% 33kHz

    Blend3 150W / 200Ω 400kHz 2.8 45% 33kHz

    Contact Coagulation 120W / 200Ω 400kHz 3.3 40% 33KHz

    Spray Coagulation 100W / 300Ω 400kHz 5.9 8.0% 33kHz

    Bipolar Standard 100W / 100Ω 500kHz 1.3 100% Continuous

    Bipolar Auto Start 100W / 100Ω 500kHz 1.3 100% Continuous

    Bipolar Forced 80W / 100Ω 500kHz 2.7 30% 33KHz

    Bipolar Cut 120W / 200Ω 500kHz 1.6 100% Continuous

    Bipolar Blend 100W / 200Ω 500kHz 2.2 65% 33KHz

    Output Power

  • Electrosurgical Unit

    ZE

    US

    Vis

    ion

    Mode Output Power Carrier Freg.Crest

    Factors

    Duty

    Rate

    Repeat

    Freg.

    Soft Coagulation 80W / 100Ω 400kHz 1.4 100% Continuous

    Spray Coagulation 100W / 300Ω 400kHz 5.9 8.0% 33kHz

    Papillotomy 150W / 100Ω 400kHz

    Polypectomy 150W / 100Ω 400kHz

    Output Power(Optional)

  • Electrosurgical Unit

    Standard AccessoriesZ

    EU

    S V

    isio

    n

    Single foot switch

    (FS01-03R)

    Double foot switch

    (FS02-01R)

    Disposable twin button handle

    (HD02-01D)

    Monopolar handle

    (HD01-02R)

    Knife Electrode (EL01-02D)

    Ball Electrode (EL02-02D)

    Needle Electrode (EL04-03D)

    Needle Electrode Angled (EL04-04D)

    Loop Electrode (EL03-02D)

    Ground Cable

    (CA03-01R)

    Return patient plate

    cable (CA02-02R)

    Bipolar forcep cable

    (CA01-02R)

    Disposable return patient

    Plate ( PL03-02D)

    Bayonet 17.8cm 1.0Tip (BF01-01R)

    Silicone patient plate

    (PL02-01R)

    Power Cord

    (CA04-01R)

  • Electrosurgical Unit

    Optional AccessoriesZ

    EU

    S V

    isio

    n

    Straight 9.0cm 0.5 Tip (BF02-01R)

    Angled 9.0cm 0.5 Tip (BF03-01R)

    Straight 12.1cm 1.0 Tip (BF02-02R)

    Straight 17.8cm 1.0 Tip (BF02-03R)

    Angled 17.8cm 1.0 Tip (BF02-03R)

    Bayonet 15.2c m 1.0 Tip (BF01-02R)

    Cart

    (CT01-01R)Monopolar Connecting

    Cable (CA08-01R)

  • Electrosurgical Unit

    Feature

    ● One equipment provides such functions that are required to perform an operation as Functional Cutting (Pure Cut,

    Blend1, Blend2, Blend3), Coagulation (Spray Coagulation, Contact Coagulation), Bipolar Coagulation (Bipolar Standard,

    Bipolar Auto Start, Bipolar Forced, Bipolar Cut, Bipolar Blend).

    ● Each application mode (Cutting, Coagulation, Bipolar Coagulation) has a different sound, which enables you to easily

    distinguish an operation type.

    ● If the area between a patient and the pad is not appropriate, REM(Return Electrode Monitoring) gives the alarm with a

    warning sound and stop an operation of the product to prevent a burning incident.

    ● The level of alarm sound can be adjusted during an operation of application mode.

    ● The selected output ratio of Cut, Coagulation, and Bipolar Coagulation will displayed by reenergizing the device after

    power OFF.

    ● Two Twin Button Handles provide remote-control function. (Select Cutting or Coagulation)

    ● Foot Switch is available for Cutting and Coagulating.

    ● Microprocessor can straighten, stabilize the output.

    ● Operations of Cutting, Coagulation and Bipolar Coagulation can be distinct from each other by sound and indication lamp.

    ● 99 storages are available by using user storage function.

    ● The input power frequency 50Hz / 60Hz is automatically detected.

    ● It can be used by selecting the monopolar output (M1, M2).

    ZE

    US

    Vis

    ion

    ● This equipment consists of 7 inch of TFT LCD and 5 functional keys which are placed in the front part.

    ● With the adoption of touch screen, it is easy to select menu, operation functions and RF output.

    ● Menu and operation functions can be selected by Menu Button, Esc Button, Enter Button, Up Button and Down Button.

    ● The ON/OFF function of Touch Screen is provided.

  • Electrosurgical Unit

    Safety Function

    ① A fuse built in a power circuit prevent an over current from flowing through the equipment.

    ③ REM (Return Electrode Monitoring) monitors the size of contacting area between a patient and the pad. If the size isinappropriate, it automatically blocks the high- frequency current to minimize the danger of burning incidents.

    ④ To protect a patient, the case is fully grounded so that a leakage current can flow into the earth.

    ② When the plate attached to the patient is separated from the equipment, the red alarm light begins flickering.Pressing the button of Twin Button Handle or the pedal of Cutting and Coagulation of Double Foot Switch will

    stop the alarm sound and the equipment.

    ZE

    US

    Vis

    ion

  • ARGON-Z

    ZERONE CO., LTD.

  • Argon Plasma Coagulation

    ARGON-Z Specification

    AR

    GO

    N-Z Rated Voltage AC100V - AC240V

    Rated Frequency 50Hz or 60Hz

    Power Consumption 50VA +10%

    Fuse T0.5AL 250V

    Protection class Class 1, Type CF

    Input Pressure Min2.5bar(250kpa) ~ Max 4.5bar(450kpa)

    Minimum purity of argon 99.998%

    Argon gas flow, CUT 0.1 l/min ~ 9.9 l/min

    Argon gas flow, COAG. 0.1 l/min ~ 9.9 l/min

    Minimum cylinder pressure 200bar(200MPa)

    Weight 6Kg

    Size(W× D × H) 330mm × 380mm × 130mm

    Using Environment

    Operation temperature 10℃ to 40℃

    Storage temperature 10℃ to 40℃

    Humidity 30% to 75% RH,

    Operation altitude 700mbar ~ 1060mbar

    Operation Cycle 10sec ON 30sec Idle

  • Standard AccessoriesA

    RG

    ON

    -Z

    Double foot switch

    (FS02-02R)

    Foot Switch Signal Cable

    (CA05-01R)

    Monopolar Cable

    (CA06-01R)

    Ground Cable

    (CA03-02R) * 2

    Luer Lock Tube

    (TB01-01R)

    Power Cord

    (CA04-01R)

    Argon Cart

    (CT01-02R)

    Ground Cable

    (CA03-01R)

    Silicone patient plate

    (PL02-01R)

    Reusable Flexible Argon

    Probe (AP01-02R)Reusable Flexible Argon

    Probe Cable (CA07-02R)

    Regulator

    ( RG01-01R)

    국가별Argon Cylinder 사용규격(CGA No.)에따라출고

    Argon Plasma Coagulation

  • Optional AccessoriesA

    RG

    ON

    -Z

    Argon Electrode Handle

    (HD03-01R)

    Argon Cutting Electrode(177.5mm) (EL01-03R)

    Cylinder 5ℓ

    (CL1-01R)

    Argon Needle Electrode(177.5mm) (EL04-05R)

    Argon Coagulation Electrode(368.5mm)(EL05-01R)

    Argon Plasma Coagulation

  • Electrosurgical Unit

    Feature

    AR

    GO

    N-Z

    ● Convenient LCD display on the front plate.

    ● Resection and coagulation by Argon Twin Button Handle

    ● Foot Switch is available for Cutting and Coagulating.

    ● Automatic adjustment of output (flow) by Microprocessor.

    Safety Function

    Advantage

    ● 9 storages are available by using user storage function.

    ● Distinction of cut and coagulation on display

    ● Even Coagulation by Contactless Coagulation

    ● Fast hemostasis, when massive bleeding

    ● Small Carbonization and almost none Sticking

    ● Easy and clean range of vision due to small smoke

    ● A fuse built in a power circuit prevent an over current from flowing through the equipment.

    ● Where there is no Gas, press the button of Argon Twin Button Handle or pedal of Foot Switch, and it shows warning,

    generates beep sound, and stops working.

    ● It earths the whole case and leak current which may flow through the patient, flow through the ground to protect the

    patient safely.