Z3N-TR22
description
Transcript of Z3N-TR22
1987 1988 Z3N 1998 1998 3 20 1998 8 11 ISO9000 90 Z3NsickNT6 KS-C2 Z3JOMRON E3J HGKOPE CYM Huizhou City, Teng Sheng Julong Electronics Business Department 68 516001 ADD:NO.2075 Silver Lake Building, NO.68 HUANCHENG XI 2ROAD, Huizhou City, Guangdong, China TEL:+86(0)752-2227308Fax:+86(0)752-2205953Mobile phone:+86(0)013669595488 Internetwww.gdhzcxs.cpooo.comE-mail:[email protected] Internethttp://julonghzdz.cn.alibaba.comWorking QQ:646854535 Z3N--Key technique parameters checking modeCo-axial checking distance10mm2mm Voltage supplyDC10-30V10%wsve10% work currencyminus45mA Light source spectrumredgreenbluewhite Light spot 0.5-1.5 checking angle15vertical with surface with15tolerance response time0.1-1ms output modeNPN:NPN:operatewithlightor without light output indicationLED red LED currency load200mA(max) circuit protection device200mA ,200mA Vcpolarprotectionshort-circuit protection sensitivityAdiustable anti-background light incandescentlight 3000Lxsunlight10000Lx protection levelIP67 enviroment protection temperaturework at-1565storage-2580 shell materialMetal connection wire 5.4PVC 2M5.4PVC 4-core cable L=2m weight500gAbout 500g MODEL ModelLight sourseOutput wireLight sourseOutput wire Z3N-TR22red4 coreZ3N-TR2red3core Z3N-TG22green4 coreZ3N-TG2green3core Z3N-T22red/green4 coreZ3N-T2red/green3core Z3N-TB22green/blue4 coreZ3N-TB2green/blue3core Z3N-TW22green/white4 coreZ3N-TW2green/white3core OPERATING SET-UP Fix them in accordance with the demands of the testing distance.Then according to the packing paper you use, refer to the Guide Grids(for reference of light source choice)to decide on the light source(take the green one as example),and then decidethebrightmarksensorsonorthedarkonetomeetyourmachine`sneed.Nowyoucanadjustthesensitivity according to the following three steps(take,as example,that the outpue mark sensors on is a bright one,the packing paper is of light color and the background is dark color) First,movethepackingpaper,castthelightonthebackgroundoutsidethesign.Turnthesensitivitycontrolcounter clockwisetilltotheend,thenturnitclockwisetilltheindicatorlightjustturnsred,andrememberthepositionofthe sensitivity control is in the position of Point A as in picture 1.If the sensitivity control is tumed to the High position and the indicator light still does not turm red,then the High position is Point A. second,move the packing paper again,and when you cast the light on the center of the sign,the indicator light will turn red.Then turn the knob counter clockwise slowly till the indicator lamp just goes out,and remember the sensitivity control is in the position of Point B as shown in Picture 2 Afteroperatingtheabovetwostepscorrectly,you can then turn thesensitivitycontrol toa positionbetween PointA and Point B,that is,Position C as shown in Picture 3,and now the adjustment is finished. The longer the distancebetween Point A and B is,the higher the ratio of the chromatic aberration and the stabler the test will be. The distance must be at least one scale between Point A and point B,otherwise the test will not be stable. , 1 A A 2;()B . 3,A B (3)AB AB