YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39...

48
UPS catalogue 2015 YOUR POWER IN SAFE HANDS

Transcript of YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39...

Page 1: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

UPS catalogue 2015YOUR POWER IN SAFE HANDS

Page 2: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

The E Series UPS range from Dale Power Solutions

Keeping the power secure

Contents 1 Introduction

2 E-Series UPS Power Matrix

4 E200R Series 1–3kVA

6 E200R+ Series 1–3kVA

8 E200+ Series 1–3kVA

10 E200 Series 1–3kVA

12 E200R Series 6–10kVA

14 E200 Series 10–20kVA

16 E300 Series 10–250kVA

20 E600 Series 10–200kVA

24 E700 Series 10–40kVA

28 E800 Series 10–600kVA

32 E900 Series 10–200kVA

36 Could your business cope without power?

37 Remote Monitoring

38 Total Secure Power Solution

39 UPS Service & Support

40 Corporate & Social Responsibility

41 E Series UPS Secure Power

42 Secure power when you need it

43 Summary of UPS AC & DC Systems

44 Delivering secure power

E Series UPS Secure Power

Page 3: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 01

Your total power solutions partnerIn an uncertain world, where rocketing demand is putting a strain on power supplies, you need the total confidence in your back-up power that Dale provides. Select from our standard range of UPS and generators, or our secure power projects providing your ideal standby power solution. Our integrated UPS and generator solutions provide ‘no-break’ power, saving you from costly outages and downtime. We deliver flexible, innovative and cost effective secure power solutions, service and maintenance and manage the complete lifecycle of your equipment.

Manufacturing excellenceOperating lean and efficient 6 Sigma designed working practices, we ensure that your exact requirements are met - from design to a finished product of the highest quality and reliability. All systems are built and tested, including customer witness testing, under the highest levels of quality control.

Outstanding featuresFeatures include internal failsafe bypass, extended run times, and high input power factor. With maximum reliability and power availability you can connect several units in parallel. The E Series has multi-language touch screen displays, remote monitoring, an advanced IGBT rectifier, back-feed protection and is configurable for redundancy.

Leading edge technologyThe outstanding E series uses double conversion technology (VFI) with the UPS load powered continuously by the inverter. This guarantees that the critical UPS load receives a stable, clean, regulated sinusoidal power supply.

Expert project management, installation and commissioningYour system is in expert hands. Project managers work with you to plan, control and co-ordinate everything from order placement, design and manufacture to installation. Our engineers join you on site to install and commission your equipment.

Future proof modular flexibilityA modular approach to system design includes hot-swappable modules ensuring maximum up time. Your power solution lifecycle is totally flexible with ease of maintenance and expandability. As your power requirement grows so can your power solution, guaranteeing continued reliability. Safe removal and insertion of the UPS modules ensure no risk to the critical load.

Protecting the environmentOur systems are designed and manufactured using the minimum amount of resources, can be upgraded or refurbished to reduce material consumption and extend product life, and can be safely recycled, avoiding the need for system disposal. The E Series is designed with selectable ECO-mode, guaranteeing high operation efficiency.

Unrivalled service and supportOutstanding service and maintenance support is backed by more than 77 years’ experience, a worldwide team of service personnel, access to a comprehensive parts and spares archive and 24/7 expert help available.

Setting the benchmark in UPS solutions

Page 4: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

E-Series UPS Power MatrixAt a glance

02

E200 E200R

Power (kVA) 1:1 3:13:11:1

E200R+

1:1

E300

3:3

E200+

1:1

1 kVA

2 kVA

3 kVA

6 kVA

10 kVA

15 kVA

20 kVA

30 kVA

40 kVA

50kVA

60 kVA

80 kVA

100 kVA

120 kVA

160 kVA

200 kVA

250 kVA

300 kVA

400 kVA

500 kVA

600 kVA

Page 5: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 03

E600 E600 Module

1:1 3:13:33:1 3:31:1 3:3

E700

3:3

E800

3:3

E900

Page 6: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

E200R SeriesAn Advanced UPS Technology

1:1 Phase | 1– 3 kVA | 0.8PF

4

FEAtURES

3 High frequency, double conversion on-line technology

3 Rotatable LCD – suitable for 19" rack or slim tower

3 Fully digital DSP control

3 Wide input voltage range

3 Cold start function

3 Advanced battery management

3 Selectable ECO mode for high efficiency operation

3 Automatic battery charge in UPS off mode

3 Lightning and surge protection

3 Short circuit and overload protection

3 Automatic fan speed control with load variation

3 Smart RS232 communications with monitoring software

3 USB communications port included

3 Optional relay or SNMP communications card

3 Matching EER battery packs available

3 E suffix models have no internal battery and increased charging capacity

RELAY CARDBAttERY PACk SNMP CARDIntelligent Slot options:

OR

Page 7: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 5

APPLICAtION

Server, Telecommunications, Networking, Desktop, CCTV

SPECIFICAtIONS

UPS Model E201R E202R E203RCapacity 1000VA / 800W 2000VA / 1600W 3000VA / 2400W

Input Voltage Range 115V AC – 295V AC, load < 70%

160V AC – 295V AC, load > 70%

Phase Single phase

Frequency 46 – 54 ±0.5Hz or 56 – 64Hz ±0.5Hz (auto sensing)

Power Factor >0.98

Output Voltage 220 / 230 /240V AC ±2% (factory set)

Phase Single phase

Frequency range 50 / 60Hz ±0.2%

THD (Linear Load) < 3%

THD (Non-Linear Load) < 6%

Overload Capability >110% for 30 sec then transfer to bypass

>150% for 0.3 sec then transfer to bypass

Crest Factor 3:1 (max)

Power Factor 0.8

Short Circuit Protection On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm

Battery mode: Inverter turns off after 5 cycles & provides an alarm

Bypass mode: AC input fuse blows or circuit breaker operates

Waveform Sine wave

Transfer Time 0ms (between on-line mode & battery mode)

Efficiency On-line mode: ≥ 87% On-line mode: ≥ 88%

Battery Model 12V valve regulated lead acid maintenance free

DC Voltage 24V DC 48V DC 72V DC

Battery 2× 12V / 9Ah 4× 12V / 9Ah 6× 12V / 9Ah

Backup Time At Half Load 10 mins 10 mins 10 mins

Backup Time At Full Load 4 mins 4 mins 4 mins

Charge Current Internal battery: 1A

Recharge Time 90% capacity after 8 hours charging

Environment Temperature 0°C to +40°C

Relative Humidity 0 – 95% (non-condensing)

Altitude 1500m maximum

Storage Temperature -25°C to +55°C

Communication Standard: RS232, USB Optional: SNMP or Relay Card

LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass

LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation

Noise Level < 45dBA

Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006

Weight & Dimensions Standard Unit Weight 12.0kg 21.1kg 26kg

Dimensions (H × W × D) 400 × 380 × 86.5 mm 440 × 520 × 131 mm

Standard Accessories Control Software Yes Yes Yes

Input & Output Leads Yes Yes Yes

Data Lead Yes Yes Yes

User Manuals Yes Yes Yes

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

Page 8: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

E200R+ SeriesAn Advanced UPS Technology

1:1 Phase | 1– 3 kVA | 0.9PF

6

FEAtURES

3 High frequency, double conversion on-line technology

3 Fully digital DSP control

3 User friendly LCD interface

3 Wide input voltage range

3 Cold start function

3 Advanced battery management

3 Selectable Eco mode for high efficiency operation

3 Automatic battery charge in UPS off mode

3 Lightning and surge protection

3 Short circuit and overload protection

3 Automatic fan speed control with load variation

3 Smart RS232 communications with monitoring

software

3 USB communications port included

3 Optional relay or SNMP communications card

3 Matching EER+ battery packs available

3 Programmable load shedding in battery mode

UPDATED

RELAY CARDBAttERY PACk SNMP CARDIntelligent Slot options:

OR

Page 9: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 7

APPLICAtION

Server, Telecommunications, Networking, Desktop, CCTV

SPECIFICAtIONS

UPS Model E201R+ E202R+ E203R+Capacity 1000VA / 900W 2000VA / 1800W 3000VA / 2700W

Input Voltage Range 160V AC – 295V AC

Phase Single phase

Frequency 46 – 54Hz ±0.5Hz or 56 – 64Hz ±0.5Hz (auto sensing)

Power Factor >0.98

Output Voltage 200 / 208 / 220 / 230 / 240V AC ±2% (factory set)

Phase Single phase

Frequency Range 50 / 60Hz ±0.02Hz

THD (Linear Load) < 3%

THD (Non-Linear Load) < 5%

Overload Capability Up to 130% for 30 sec then transfer to bypass

130% – 200% for 0.3 sec then transfer to bypass

>200% for 0.2 sec then transfer to bypass

Crest Factor 3:1 (max)

Power Factor 0.9

Short Circuit Protection On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm

Battery mode: Inverter turns off after 5 cycles & provides an alarm

Bypass mode: AC input fuse blows or circuit breaker operates

Waveform Sine wave

Transfer Time 0ms (between on-line mode & battery mode)

Efficiency ≥ 89% AC mode

≥ 84% battery mode

Battery Model 12V valve regulated lead acid maintenance free

DC Voltage 36V DC 72V DC 72V DC

Battery 3× 12V / 9Ah 6× 12V / 9Ah 6× 12V / 9Ah

Backup Time At Half Load 14 mins 14 mins 8 mins

Backup Time At Full Load 5 mins 5 mins 3 mins

Charge Current 1A

Recharge Time 90% capacity after 5 hours charging

Environment Temperature 0°C to +40°C

Relative Humidity 0 – 90% (non-condensing)

Altitude 1500m maximum

Storage Temperature -25°C to +55°C

Communication Standard: RS232, USB Optional: SNMP or Relay Card

LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass

LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation

Noise Level < 55dBA

Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006

Weight & Dimensions Standard Unit Weight 18.7kg 31.3kg 33.0kg

Dimensions (H × W × D) 86.5 × 440 × 430 mm 86.5 × 440 × 690 mm

Standard Accessories Control Software Yes Yes Yes

Input & Output Leads Yes Yes Yes

Data Lead Yes Yes Yes

User Manuals Yes Yes Yes

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

Page 10: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

E200+ SeriesAn Advanced UPS Technology

1:1 Phase | 1– 3 kVA | 0.9 PF

8

FEAtURES

3 High frequency, double conversion on-line technology

3 Fully digital DSP control

3 User friendly LCD interface

3 Wide input voltage range

3 Cold start function

3 Advanced battery management

3 Selectable ECO mode for high efficiency operation

3 Automatic battery charge in UPS off mode

3 Lightning and surge protection

3 Short circuit and overload protection

3 Automatic fan speed control with load variation

3 Smart RS232 communications with monitoring software

3 USB communications port included

3 Optional relay or SNMP communications card

3 Matching EE+ battery packs available

3 Programmable load shedding in battery mode

3 Emergency Power Off function

RELAY CARDBAttERY PACk SNMP CARDIntelligent Slot options:

OR

Page 11: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com

APPLICAtION

Server, Telecommunications, Networking, Desktop, CCTV

SPECIFICAtIONS

UPS Model E201+ E202+ E203+Capacity 1000VA / 900W 2000VA / 1800W 3000VA / 2700W

Input Voltage Range 160V AC - 295V AC

Phase Single phase

Frequency 46 – 54Hz ±0.5Hz or 56 – 64Hz ±0.5Hz (auto sensing)

Power Factor 0.98

Output Voltage 200/208/220/230/240V AC ±2% (factory Set)

Phase Single phase

Frequency Range 50 / 60Hz ±0.2% (auto selected at start up)

THD (Linear Load) < 3%

THD (Non-Linear Load) < 5%

Overload Capability Up to 130% for 30 sec then transfer to bypass

130% - 200% for 0.3 sec then transfer to bypass

>200% for 0.2 sec then transfere to bypass

Crest Factor 3:1 (max)

Power Factor 0.9

Short Circuit Protection On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm

Battery Mode: Inverter turns off after 5 cycles & provides an alarm

Bypass mode: AC input fuse blows or circuit breaker operates

Waveform Sine wave

Transfer Time 0ms (between on-line mode & battery mode)

Efficiency ECO mode: ≥94% AC mode: ≥89% Battery mode: ≥84%

Battery Model 12V valve regulated lead acid maintenance free

DC Voltage 36V DC 72V DC 72V DC

Battery 3x 12V / 9Ah 6x 12V / 9Ah 6x 12V / 9Ah

Backup Time At Half Load 14 mins 14 mins 8 mins

Backup Time At Full Load 5 mins 5 mins 3 mins

Charge Current 1A

Recharge Time 90% capacity after 5 hours charging

Environment Temperature 0°C to +40°C

Relative Humidity 0 – 95% (non-condensing)

Altitude 1500m maximum without derate

Storage Temperature -25°C to +55°C

Communication Standard: RS232, USB Optional: SNMP or Relay Card

LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass

LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation

Noise Level < 55dBA

Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006

Weight & Dimensions Standard Unit Weight 13.0kg 24.6kg 25.5.0kg

Dimensions (H × W × D) 215 x 144 x 409 mm 337 x 199 x 466 mm

Standard Accessories Control Software Yes Yes Yes

Input & Output Leads Yes Yes Yes

Data Lead Yes Yes Yes

User Manuals Yes Yes Yes

9

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

Page 12: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

E200 SeriesAn Advanced UPS Technology

1:1 Phase | 6 – 10 kVA | 0.8PF

10

RELAY CARD SNMP CARD PARALLEL CARDIntelligent Slot options:

BAttERY PACk

FEAtURES

3 High frequency, double conversion on-line technology

3 Fully digital DSP control

3 Wide input voltage range

3 Integral ‘hot-swap’ maintenance bypass module

3 Cold start function

3 Advanced battery management

3 Selectable ECO mode for high efficiency operation

3 Automatic battery charge in UPS off mode

3 Lightning and surge protection

3 Short circuit and overload protection

3 Automatic fan speed control with load variation

3 Parallel capacity or redundancy (maximum 4 units)

requires a parallel card as factory fitted option

3 Smart RS232 communications with monitoring software

3 Optional relay or SNMP communications card

3 Matching EE2000 battery packs available

3 E suffix models have no internal battery and increased charging capacity

3 Internal removable bypass switch

Page 13: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 11

APPLICAtION

Server, Telecommunications, Networking, Desktop, CCTV

SPECIFICAtIONS

UPS Model E206 E206E E2010 E2010ECapacity 6000VA / 4800W 10000VA / 8000W

Input Voltage Range 120V AC – 276V AC

Phase Single phase

Frequency 40 – 70Hz

Power Factor ≥ 0.99

Output Voltage 220 / 230V AC ±2%

Phase Single phase

Frequency Range 50 / 60Hz (user adjustable)

THD (Linear Load) ≤ 2%

THD (Non-Linear Load) ≤ 6%

Overload Capability ≤ 130% load for 10 min then transfer to bypass

> 130% load for 1 sec then transfer to bypass

Crest Factor 3:1 (max)

Power Factor 0.7 (16 or 18× 12V batteries) or 0.8 (20× 12V batteries)

Short Circuit Protection On-line mode: ≥ 5 cycle duration, inverter turns off, no transfer to bypass, unit alarms

Battery mode: ≥ 5 cycle duration, inverter turns off, bypass unavailable, unit alarms

Bypass mode: Input fuse blows or breaker operates, no alarm

Waveform Sine wave

Transfer Time 0ms (between on-line mode & battery mode)

Efficiency On-line mode: ≥ 90%

Battery Model 12V valve regulated lead acid maintenance free

DC Voltage 192V DC 192 / 216 / 240V DC 192V DC 192 / 216 / 240V DC

Battery 16× 12V / 9Ah 16 / 18 / 20× 12V 16× 12V / 9Ah 16 / 18 / 20× 12V

Backup Time At Half Load 14.3 min Depends on ext. battery 6.5 min Depends on ext. battery

Backup Time At Full Load 5.5 min Depends on ext. battery 2.5 min Depends on ext. battery

Charge Current 1.0A 1.0 – 6.0A (selectable) 1.0A 1.0 – 6.0A (selectable)

Recharge Time 90% capacity after 8 hrs Depends on ext. battery 90% capacity after 8 hrs Depends on ext. battery

Environment Temperature 0°C to +40°C

Relative Humidity 0 – 95% (non-condensing)

Altitude 1500m maximum

Storage Temperature -25°C to +55°C

Communication Standard: RS232 Optional: USB, SNMP or Relay Card

LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass

LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation

Noise Level < 55dBA

Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006

Weight & Dimensions Standard Unit Weight 77kg (nett) / 84 kg (gross) 35kg (nett) / 42kg (gross) 80kg (nett) / 87kg (gross) 38kg (nett) / 45kg (gross)

Dimensions (H × W × D) mm 655 × 250 × 590 mm 655 × 250 × 590 mm

Standard Accessories Control Software Yes

Input & Output Leads Optional extra

Battery Leads Optional extra

Data Lead & User Manual Yes

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

Internal removable bypass switch

Page 14: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

E200R SeriesAn Advanced UPS Technology

3:1 or 1:1 | 6 – 10 kVA | 0.9PF

12

RELAY CARD SNMP CARDIntelligent Slot options:

OR

FEAtURES

3 High frequency, double conversion on-line technology

3 Input can be configured for either 3:1 or 1:1 operation

3 Rotatable LCD – suitable for 19" rack or slim tower

3 Fully digital DSP control

3 Wide input voltage range

3 Cold start function

3 Advanced battery management

3 Selectable ECO mode for high efficiency operation

3 Automatic battery charge in UPS off mode

3 Lightning and surge protection

3 Short circuit and overload protection

3 Automatic fan speed control with load variation

3 Up to 4 units can be operated in parallel

3 Smart RS232 communications with monitoring software

3 USB communications port included

3 Optional relay or SNMP communications card

3 Matching EER2000 battery pack available

BAttERY PACk

Page 15: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 13

APPLICAtION

Server, Telecommunications, Networking, Desktop, CCTV

SPECIFICAtIONS

UPS Model E21306RE E21310RECapacity 6000VA / 5400W 10000VA / 9000W

Input Rated Voltage 380 / 400 / 415V AC or 220 / 230 / 240V AC

Voltage Range 120V AC – 276V AC Line – Neutral or 208V AC – 478V AC Line – Line

Phase 3 Phase 4 Wire & Earth or 1 Phase 2 Wire & Earth

Frequency 40 – 70Hz

Power Factor ≥0.99

Output Voltage 220 / 230 / 240V AC ±2%

Phase Single phase

Frequency Range 50 / 60Hz ± 0.2Hz (user adjustable)

THD (Linear Load) ≤ 2%

THD (Non-Linear Load) ≤ 5%

Overload Capability AC Mode: ≤110% for 3 min, ≤125% for 30 sec, ≤150% for 1 sec, >150% shutdown immediately, transfer to bypass

Battery Mode: ≤110% for 30 sec, ≤125% for 1 sec, ≤150% for 0.2 sec, >150% shutdown immediately

Crest Factor 3:1 (max)

Power Factor 0.9

Short Circuit Protection Yes

Waveform Sine wave

Transfer Time 0ms (between on-line mode & battery mode)

Efficiency On-line mode: ≥ 90%

Battery Model 12V valve regulated lead acid maintenance free

DC Voltage 192 / 216 / 240V DC

Backup Time At Half Load

Backup Time At Full Load

Charge Current 6A (Maximum)

Recharge Time 90% capacity after 8 – 10 hours charging

Environment Temperature 0°C to +40°C

Relative Humidity 0 – 95% (non-condensing)

Altitude 1500m maximum

Storage Temperature -25°C to +55°C

Communication Standard: USB, RS485 & Parallel Port Optional: SNMP or Relay Card

LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass

LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation

Noise Level < 55dBA

Safety & EMC CE marked to EN62040-1-1:2008 & EN62040-2:2006

Weight & Dimensions Standard Unit Weight 23.0kg 25.0kg

Dimensions (H × W × D) 131 × 443 × 580 mm

Standard Accessories Control Software Yes Yes

Input & Output Leads Yes Yes

Data Lead Yes Yes

User Manuals Yes Yes

Battery Leads Optional extra Optional extra

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

Depends on the external battery capacity

Page 16: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

14

E200 SeriesAn Advanced UPS Technology

3:1 Phase | 10 –20kVA | 0.8PF

FEAtURES

3 High frequency, double conversion on-line technology

3 Fully digital DSP control

3 Wide input voltage range

3 Integral ‘hot-swap’ maintenance bypass module on E2310(E) model

3 Cold start function

3 Advanced battery management

3 Selectable ECO mode for high efficiency operation

3 Automatic battery charge in UPS off mode

3 Lightning and surge protection

3 Short circuit and overload protection

3 Automatic fan speed control with load variation

3 Parallel capacity or redundancy (maximum 4 units) requires a parallel card as factory fitted option

3 Smart RS232 communications with monitoring software

3 Optional relay or SNMP communications card

3 Matching EE2000 battery packs available for E2310(E) model

RELAY CARD SNMP CARD PARALLEL CARDIntelligent Slot options:

Page 17: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 15

APPLICAtION

Server, Telecommunications, Networking, Desktop, CCTV

SPECIFICAtIONS

UPS Model E2310E E2315E E2320ECapacity 10000VA / 8000W 15000VA / 12000W 20000VA / 16000W

Input Voltage Range 176V AC to 275V AC Line – Neutral

Phase 3 Phase 4 Wire & Earth

Frequency 40 – 70Hz

Power Factor ≥ 0.99

Output Voltage 220 / 230V AC ±2%

Phase Single phase

Frequency Range 50 / 60Hz (user adjustable)

THD (Linear Load) ≤ 2%

THD (Non-Linear Load) ≤ 6%

Overload Capability ≤ 130% load for 10 min then transfer to bypass

> 130% load for 1 sec then transfer to bypass

Crest Factor 3:1 (max)

Power Factor 0.7 (16 or 18× 12V batteries) or 0.8 (20× 12V batteries)

Short Circuit Protection On-line mode: ≥ 5 cycle duration, inverter turns off, no transfer to bypass, unit alarms

Battery mode: ≥ 5 cycle duration, inverter turns off, bypass unavailable, unit alarms

Bypass mode: Input fuse blows or breaker operates, no alarm

Waveform Sine wave

Transfer Time 0ms (between on-line mode & battery mode)

Efficiency On-line mode: ≥ 90%

Battery Model 12V valve regulated lead acid maintenance free

DC Voltage 192 / 216 / 240V DC

Battery 16 / 18 / 20× 12V blocks

Backup Time At Half Load Depends on external battery

Backup Time At Full Load Depends on external battery

Charge Current 1.0 – 6.0A (selectable)

Recharge Time Depends on external battery

Environment Temperature 0°C to +40°C

Relative Humidity 0 – 95% (non-condensing)

Altitude 1500m maximum

Storage Temperature -25°C to +55°C

Communication Standard: RS232 Optional: USB, SNMP or Relay Card

LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass

LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation

Noise Level < 55dBA

Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006

Weight & Dimensions Standard Unit Weight 40kg 45kg 45kg

Dimensions (H × W × D) mm 655 × 250 × 590 mm 655 × 250 × 590 mm

Standard Accessories Control Software Yes

Input & Output Leads Optional extra

Battery Leads Optional extra

Data Lead & User Manual Yes

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

Page 18: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

E300 SeriesAn Advanced UPS Technology

3:3 Phase | 10 – 250kVA | 0.8PF

16

FEAtURES

3 High frequency double conversion on-line UPS

3 Fully digitised microprocessor control

3 Parallel capacity or redundancy (maximum 4 units)

3 Wide input voltage range from single or dual source

3 Open architecture design provides full access for servicing

3 Intelligent battery charge management

3 RS232/RS485 communication with monitoring software

3 Short circuit and overload protection

3 Over temperature and over humidity protection

3 EMI and RFI noise filtering

3 ECO Mode

3 User friendly LCD interface

3 Cold start and programmable auto re-start functions (optional extra)

3 Fan speed auto control with load variation

3 Built-in static and maintenance bypass switches

3 Back feed protection between UPS output and mains supply

3 Emergency Power Off function

3 Low THD & high input power factor for diverse generator compatibility

3 Soft start with programmable power walk-in

3 Optional temperature compensated battery charging

3 Optional SNMP, relay card and remote monitoring panel

3 Optional galvanic isolation transformer

3 Nicad battery option available

RELAY CARD SNMP CARDIntelligent Slot options:

UPDATED

Page 19: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 17

COMMON SPECIFICAtIONS

Input Voltage Range 176V AC to 264V AC Line-Neutral

Phase 3 Phase 4 Wire & Earth

Frequency 50 / 60Hz ±10% (user adjustable)

Power Factor > 0.99

Output Voltage 220 / 230V AC Line-Neutral (user adjustable)

Phase 3 Phase 4 Wire & Earth

Frequency range 50 / 60Hz (user adjustable)

THD (Linear Load) < 2%

THD (Non-Linear Load) < 3%

Efficiency On-line mode: 93% ECO mode: 98%

Overload Capacity 125% load for 10 min, 150% load for 1 min

Crest Factor 3:1

Power Factor 0.8

Short Circuit Protection IGBT controlled electronic protection

Waveform True sine wave

Transfer Time 0ms (on-line mode)

Battery External Up to 50 x 12V mono blocks (600V DC Nominal)

Environment Altitude 1000m at rated power

Operate Temperature 0°C to 40°C

Relative Humidity 0 – 95% (non-condensing)

Communication Standard: RS232 / RS485 Optional: SNMP and relay cards, remote monitoring panel

LCD Screen Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass

LED Indication Double conversion on-line or ECO line interactive (user selectable) Mimic panel overview of UPS operation and alarms

Noise Level <60dBA

Safety & EMC CE marked and tested to EN62040-1-1, IEC60950 & EN62040-2 Class A

Standard Accessories Control software, data lead & user manual

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

MODEL SPECIFICAtIONS

The Dale E300 series is the innovative new generation of high frequency, on-line double conversion Uninterruptible Power Supplies.Full DSP controlled inverter technology ensures continuous, clean, true sinusoidal power to critical applications under a wide range of conditions. Available in output power capacities from 10 to 250kVA, all with three phase input and output. Innovative and inspired in concept, designed and manufactured with engineering precision to deliver pure, resilient power to the most critical of applications.

Model No. E310 E315 E320 E330 E340 E360 E380 E3100 E3120 E3160 E3200 E3250

Output (kVA) 10 15 20 30 40 60 80 100 120 160 200 250

Rating (kW) 8 12 16 24 32 48 64 80 96 128 160 200

Full load Efficiency 93% 93% 93% 93% 93% 93% 93% 93% 93% 93% 93% 93%

Battery Quantity 28-50 28-50 38-50 38-50 48-50 50 50 50 50 50 50 50

Weight 115 115 125 150 156 165 320 360 385 550 575 700

Dim (H x W x D mm) 460 x 805 x 1190 882 x 770 x 1660 1055 x 800 x 1905 1500 x 800 x 1905

Page 20: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

E300 Series

18

Automatic adjustment of charging parameters based on the battery configuration entered via the LCD panel.

Real-time battery management information is displayed on the LCD, such as battery capacity (as percentage or time remaining).

Temperature compensated battery charging monitors are available to monitor the internal and external battery temperature with a feedback control loop to adjust the charge current rate accordingly.

Programmable automatic or manual battery tests can be performed without interruption to the UPS operation or load.

DSP Controlled IGBT InverterThe DSP controlled IGBT inverter provides a clean, true sine wave output voltage to deliver the highest quality power to protect critical loads.

The DSP circuitry is embedded within a single control board to reduce hardware and improve noise immunity. Complex control algorithms are utilised with floating point controllers to ensure uninterrupted operation and protection of the loads in abnormal conditions that may cause failure.

The DSP control system achieves fast dynamic response for non-linear loads and high power factor under various load conditions.

Static & Manual (Maintenance) BypassStatic and manual bypass switches are included as standard, with operational characteristics as follows:

StAtIC BYPASSThis feature provides a safe transfer to mains should the UPS be overloaded or develop a fault condition.

DSP Power Factor Corrected IGBT RectifierIGBT power factor correction technology provides an input power factor close to unity (≥0.99) and input current total harmonic distortion (THDi) less than 3% to avoid disturbances to the connected loads.

The high input power factor leads to reduced electricity consumption, minimised switchgear and circuit protection, cabling and generator requirements, thus reducing investment cost.

Parallel and Redundant OperationCapability to connect up to 4 units in parallel to provide increased power capacity or redundancy. All parallel units can be operated from the front panel of any UPS.

POWER INCREASEUnits can be connected in parallel to increase the total capacity of the system. When an inverter goes offline, the critical loads are automatically transferred to bypass.

REDUNDANCYUnits can be connected in parallel to provide redundancy for absolute reliability. In parallel redundant mode, the number of units (N) supply the load and an extra unit is provided in case of failure (N+1). All units share the load current equally. When a unit goes offline, due to failure or maintenance, the standby unit continues to supply the critical load without any interruption.

Advanced Battery ManagementIntelligent precision charging principles guarantee enhanced battery life and maximum battery performance and reliability. This provides the reassurance that the battery is primed and ready for the critical role they play in your power protection system.

The static switch contains electronically controlled switching circuits that enable the critical load to be connected to either the inverter output or to a bypass source via the static bypass line. During normal operation, the load is connected to the inverter, but in the event of a UPS overload or inverter failure, the load is automatically transferred to the static bypass line.

To provide a clean (no-break) load transfer between the inverter output and static bypass line, the static switch activates and connects the load to bypass. To achieve this, the inverter output and bypass are fully synchronised by the inverter control electronics.

MANUAL BYPASSThis feature is provided solely to allow maintenance work to be carried out on the UPS without interrupting the power to the load. The UPS can be powered down to enable technical personnel to replace parts. Full system replacement and repair of major components does however, necessitate shutdown of the load.

Optional Single or Dual Source OperationTo increase flexibility, the UPS input can be fed by single or dual sources. In dual configuration, the rectifier is fed from the utility (main source), and the static and maintenance bypasses are fed from a secondary source.

Open Architecture DesignThe UPS incorporates an open architecture design to facilitate full access to replace parts quickly and easily, resulting in low Mean Time To Repair (MTTR).

Diverse Generator CompatibilityThanks to the robust IGBT rectifier, the E300 series UPS is uniquely compatible with a diverse range of sources, in particular,

x 4

Page 21: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 19

APPLICAtION

Server, Telecommunications, Networking, Data Centre, IT, Financial, Emergency Services, Defence, Retail, Transportation, Broadcasting and Communications, Healthcare, Leisure and Sport, Government, Education

generators. Input current total harmonic distortion (THDi) of less than 3% is achieved without compromising efficiency. The high input power factor enables a generator to be utilised with a power rating only 20% higher than the UPS.

Power walk-in can be adjusted from 5 to 15 seconds. Based on the current measured on the input, the UPS gradually increases the power supplied from the utility source to the load. The power, delivered by the utility source to the load, varies according to the input voltage, current and power factor.

Back Feed ProtectionBack feed protection prevents current from the UPS output feeding back to the UPS input terminals, thereby protecting maintenance personnel from electric shock hazards whilst working on the incoming supply side of the system.

Reverse Energy Tolerance for Regenerative LoadsThe E300 series UPS is suitable for use with regenerative loads, such as synchronous motors. Regenerative loads pump energy back to the mains supply. Traditionally, UPS systems would burn this feedback energy, resulting in lower operating efficiency. The IGBT rectifier in the E300 series UPS is capable of absorbing intermittent load generated power. This reverse power tolerance facilitates the execution of important system operations, such as closed transition transfers of the UPS load directly to an engine generator source.

Lower Total Cost of OwnershipThe high efficiency operation of the UPS means that less energy is consumed to supply power to the protected loads. As a result of reduced heat emission and power loss, users benefit from reduced electricity usage and air conditioning requirements.

With reduced THDI and high 0.99 input power factor, switchgear, circuit protection, cabling and generator requirements are minimised, thus reducing investment cost.

Advanced User InterfaceThe UPS operating information and parameter settings are displayed in 4 different languages and can be accessed using the large user friendly, data rich LCD and system LED mimic panel. The UPS is capable of recording up to 500 events.

Green ECO Mode of OperationThe E300 series UPS can be operated in high efficiency ECO mode (98%) providing green energy savings through reduced power consumption.

Emergency Power Off (EPO)The EPO function is designed to switch off the UPS in an emergency situation (eg. fire, flood). Operation of the EPO turns off the rectifier and inverter and cuts power to the load immediately (both the inverter and bypass lines). The EPO also prevents the battery from charging or discharging.

With the utility input supply present, the UPS control circuits remain energised, even though the output is turned off. To remove all power from the UPS, the external feeder breaker must be opened.

Auto Re-startWhen the utility and bypass sources fail, the UPS draws power from the battery system to supply the load, until the batteries are depleted. Once the batteries reach their End of Discharge threshold, the UPS will shut down. The UPS will automatically re-start once the utility power is restored and output power to the load will be delivered. The UPS also incorporates a programmable automatic start time delay.

Advanced CommunicationsA wide range of advanced communication options are available:

ExtERNAL BAttERY tEMPERAtURE SENSOROne module is fitted to each external battery cabinet to monitor the battery temperature. A feedback control loop within the UPS adjusts the charge current based on the battery temperature, optimising battery performance and longevity.

RELAY ALARMS CARDIsolated, volt-free dry contacts indicate the UPS operating status and the presence of alarm conditions. Fully programmable to facilitate the capture of a diverse range of operating and alarm conditions. Opto-isolated inputs allow the UPS to be controlled remotely.

RS232/RS485 SERIAL PORtThe UPS operating parameters can be observed and controlled locally using an RS232/RS485 communications port. Real time notification of changes in UPS status is reported to users by SMS or e-mail.

SNMP NEtWORk CARDEnables monitoring and control of the UPS operation by ethernet or internet connection. Allows the remote execution of scheduled events and the shutdown / reboot of the UPS and multiple servers. Full event log and data management. Real time notification of changes in UPS status reported to users by audible alarm, SMS or e-mail. Software supports Windows, Linux, Mac, Solaris, Open VMS and IBM operating systems.

REMOtE LCD AND LED MIMIC PANELFacilitates the monitoring and control of the UPS operations, events and parameters from a remote location.

Page 22: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

20

E600 SeriesAn Advanced UPS Technology

1:1, 3:1, 3:3 Phase | 10 – 200kVA | 0.9PF

RELAY CARD SNMPIntelligent Slot options:

FEAtURES

3Hot swappable modular design

3 Flexible and expandable UPS power solution

3 19" cabinets available in full and half height format

3 Modular design capable of housing either 5× or 10× power modules

3 Power modules available in 10 and 20kVA ratings

3 Configurable N+1 modular redundancy

3 Parallel system capability (maximum 4x cabinets)

3 High frequency double conversion on-line technology

3 Wide input voltage range

3 Intelligent battery charge management

3 Programmable battery charge current

3 Short circuit and overload protection

3 EMI and RFI noise filtering

3 Smart RS232 communication with monitoring software

3 Fully digitised microprocessor control

3 Large touch screen LCD interface

3 Built-in maintenance bypass

3 Emergency Power Off function

3 Optional SNMP card or relay card

3 Optional hot plug internal batteries

BAttERY PACk

UPDATED96%

Efficiencyat half load

UP TO

Page 23: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 21

SPECIFICAtIONS

Cabinet Model E61150 E63150 E631100 E633100 E633200Maximum Rating 10 – 50kVA 10 – 50kVA 10 – 100kVA 10 - 100kVA 10 - 200kVA

8 – 40kW 8 – 40kW 8 – 80kW 9 – 90kW 9 – 180kW

Input Voltage range 120 to 276V AC Line - Neutral 220 / 230V AC Line - Neutral 380 / 400 / 415 AC Line - Line

Phase 1 Phase 2 Wire & Earth 3 Phase 4 Wire & Earth 3 Phase 4 Wire & Earth

Frequency 40 – 70Hz

Power factor ≥0.99

Output Voltage 220 / 230V AC Line – Neutral 220 / 230V AC Line – Neutral 380 / 400 / 415V AC Line – Line

Phase 1 Phase 2 Wire & Earth 1 Phase 2 Wire & Earth 3 Phase 4 Wire & Earth

Frequency range 50-60Hz

THD ≤2% with linear load ≤5% with non-linear load

Efficiency Utility mode > 90%

Overload capability <110% load for 60 min then transfer to bypass <125% load for 10 min then transfer to bypass < 150% load for 1 min then transfer to bypass >150% load results in automatic shutdown of UPS

Crest factor 3:1

Power factor 0.8 0.8 0.9

Short circuit protection Yes

Waveform Sine wave

Transfer time 0ms (between on-line mode and battery mode)

Battery DC voltage 16/18/20x 12V blocks 32/34/36/38/40x 12V blocks 192V/216V/240V DC 384V/408V/432V/456V/480V DC

Charge current 6A (per module)

Recharge time Depends on battery capacity and charger current

Environment Temperature 0 – 40°C

Relative humidity 0 – 95% (non-condensing)

Altitude <1500m maximum

Communication Standard: R S232 / RS485 Optional: SNMP or relay card

LCD Touch screen display Measurements: Input & output voltage/frequency, battery voltage, load power & kVA, UPS temperature Operation mode: i.e. Online, On Battery, Bypass

LED Indication Green LED: Normal operation Yellow LED: Battery mode/Bypass mode Red LED: Abnormal operation

Noise Level <62dBA

Safety & EMC CE marked and tested to EN/IEC62040-1-1 & EN/IEC62040-2

Weight & Dimensions Standard Unit Weight 150kg 150kg 213kg 170kg 230kg

Dimensions (H × W × D) mm 1400x600x840 1400x600x840 2000x600x840 1400x600x840 2000x600x1100

Standard Accessories Control software No (unless SNMP option selected)

Data lead No

User manuals Yes

Module type E61110H E63110H E63310H E63320HCapacity 10kVA 10kVA 10kVA 20kVA

Weight & Dimensions Standard Unit Weight 25kg 25kg 26kg 31kg

Dimensions (H × W × D) mm 131 × 443 × 580 (3U)

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

The Dale E600 series UPS is a sophisticated, new generation of modular, high frequency on-line double conversion Uninterruptible Power Supplies. Full DSP controlled inverter technology ensures continuous, clean, true sine wave power to critical applications under a wide range of conditions. Available in output power capacities from 10 to 200kVA in 1:1 and 3:1 phase configurations and 10 to 100kVA in 3:3 phase configuration. The E600 series UPS is the perfect modular UPS solution, capable of supporting a diverse range of mission critical applications.

Page 24: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

DSP Power Factor Corrected IGBT RectifierLatest IGBT power factor correction technology provides an input power factor close to unity (≥0.99) and input current total harmonic distortion (THDi) less than 3% to avoid disturbances to the connected loads.

N+X Parallel Modular RedundancyThe E600 series provides N+X parallel modular redundancy for absolute reliability. When a module goes offline, due to failure or maintenance, the remaining modules continue to supply the load without any interruption.

The level of redundancy can be set to suit the criticality of the protected load. Should the load increase above the redundancy threshold, the UPS will alarm to notify the user there is insufficient capacity available to maintain the load if a module fails. This allows preventative action to be taken (decrease load or install additional UPS modules).

HIgH AVAILABILItY & MtBFAll UPS modules share the load current equally. With two modules configured for redundancy, the UPS system achieves 99.999% availability and the Mean Time Before Failure (MTBF) exceeds 15,000,000 hours, satisfying the reliability requirements of the critical load.

The UPS design incorporates ‘drawer style’ hot-swap UPS modules to facilitate quick and easy replacement for low Mean Time To Repair (MTTR).

DSP Controlled IGBT InverterThe DSP controlled IGBT inverter provides a clean, true sine wave output voltage to deliver the highest quality power to protect critical loads.

Advanced Battery ManagementIntelligent precision charging principles guarantee enhanced battery life and maximum battery performance and reliability. This provides the reassurance that the battery is primed and ready for the critical role they play in your power protection system.

3 Powerful 6A charger built into each UPS module with the ability to freely set the charge current level.

3 Automatic adjustment of charging parameters based on the battery configuration settings.

3 Real-time battery management infor-mation is displayed on the LCD, such as battery capacity (as percentage or time remaining).

3 Programmable automatic or manual battery tests can be performed without interruption to the UPS operation or load. The batteries can also be ‘hot-swapped’ without disconnection of the UPS.

Single or Dual Source OperationFor increased flexibility, the E600 series UPS is available with a split bypass, enabling the UPS input to be fed by single or dual sources. In dual configuration, the rectifier is fed from the utility (main source) and the static and maintenance bypass are fed from a secondary source.

Scalable Modular Solution1.4m and 2.0m tall 19” cabinets are available, capable of holding up to 5 or 10 UPS modules respectively, providing scalability to expand as power demand increases. Up to 4 three phase cabinets may be connected in parallel configuration, providing a maximum output power capacity of 800kVA at 0.9 power factor.

Static & Manual (Maintenance) BypassStatic and manual bypass switches are included as standard, with operational characteristics as follows:

StAtIC BYPASSThis feature provides a safe transfer to mains should the UPS be overloaded or develop a fault condition.

The static switch contains electronically controlled switching circuits that enable the critical load to be connected to either the inverter output or to a bypass source via the static bypass line. During normal operation, the load is connected to the inverter, but in the event of a UPS overload or inverter failure, the load is automatically transferred to the static bypass line.

To provide a clean (no-break) load transfer between the inverter output and static bypass line, the static switch activates and connects the load to bypass. To achieve this, the inverter output and bypass are fully synchronised by the inverter control electronics.

This feature is provided solely to allow maintenance work to be carried out on the UPS without interrupting the power to the load. The UPS can be powered down to enable technical personnel to replace parts. Full system replacement and repair of major components does however, necessitate shutdown of the load.

Cold Start OperationWhen the utility and bypass sources are not available, the cold start feature enables the UPS to be started using the battery only.

Excellent Generator CompatibilityThanks to the robust IGBT rectifier, the E600 series UPS is compatible with a diverse range of sources, including generators. High Input power factor (0.99) and low input current total harmonic distortion (THDi) <3% is achieved without compromising efficiency, allowing a modestly sized generator to be utilised.

22

E600 Seriesx 4

Page 25: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 23

APPLICAtION

Server, Telecommunications, Networking, Data Centre, IT, Financial, Emergency Services, Defence, Retail, Transportation, Broadcasting and Communications, Healthcare, Leisure and Sport, Government, Education

Adjustable power walk-in allows the UPS to gradually increase the power supplied from the utility source to the load, based on the current measured on the input.

Module Options available3U high ‘drawer-style’ UPS modules with individual LCD control panel. Available in the following phase and power configurations:

3 1:1 Phase – 10kVA

3 3:1 Phase – 10kVA

3 3:3 Phase – 10 and 20kVA

Common module size: H131 × W443 × D580mm

Decentralised Parallel Structure ConceptEach UPS module contains all the required hardware and software for autonomous operation, without reliance on the centralised monitoring module. This increases system reliability by eliminating Single Points of Failure (SPOF).

Lower Total Cost of OwnershipThe high efficiency operation of the UPS (≤ 98% in ECO mode and ≤96% in On-Line mode) means that less energy is consumed to supply power to the protected loads. As a result of reduced heat emission and power loss, users benefit from reduced electricity usage and air conditioning requirements.

With low <3% THDi and high 0.99 input power factor, switchgear, circuit protection, cabling and generator requirements are minimised, thus reducing investment cost.

Advanced User InterfaceThe UPS operating information, status and parameter settings are accessed using the large user friendly, data rich LCD and

system LED mimic panel. The UPS stores 500 events on a rolling data log.

Emergency Power Off (EPO)The EPO function is designed to switch off the UPS in an emergency situation (eg. fire, flood). Operation of the EPO turns off the rectifier and inverter and cuts power to the load immediately (both the inverter and bypass lines). The EPO also prevents the battery from charging or discharging.

With the utility input supply present, the UPS control circuits remain energised, even though the output is turned off. To remove all power from the UPS, the external feeder breaker must be opened.

Auto Re-startWhen the utility and bypass sources fail, the UPS draws power from the battery system to supply the load, until the batteries are depleted. Once the batteries reach their End of Discharge threshold, the UPS will shut down. Once the utility and bypass sources are re-instated, the UPS will auto re-start, deliver power to the load and recharge the battery.

Advanced CommunicationsA wide range of advanced communication options are available:

RELAY ALARMS CARDIsolated, volt-free dry contacts indicate the UPS operating status and the presence of alarm conditions. Opto-isolated inputs allow the UPS to be controlled remotely.

Hot Plug Battery PacksSmart and simple plug and play battery solution can be installed/removed by a single operator without causing any disruption to the system.

RS232 SERIAL PORtThe UPS operating parameters can be observed and controlled locally using an RS232 communications port.

SNMP NEtWORk CARDEnables monitoring and control of the UPS operation by LAN or Internet connection and allows the remote execution of scheduled events and the shutdown/reboot of the UPS and multiple servers. Full event log and data management. Real time notification of changes in UPS status reported to users by SMS or e-mail. Software supports Windows, Linux, Mac, Free BSD and VM Ware operating systems. Accepts environmental monitoring inputs (temperature, humidity, water, smoke, security sensors).

Green ECO Mode of OperationThe E600 series UPS can be operated in high efficiency ECO mode (98%) providing green energy savings through reduced power consumption.

Centralised Monitoring ModuleAll system data is processed by a centralised monitoring module offering advanced DSP control technology. The module itself can be exchanged from the system without disrupting the protected load.

Hot swappable modulesHot swappable modules allows for modules to be removed whilst the system is live for ease of servicing or repair, this removes the need to shut down the whole system during maintenance, and allows additional modules to be added without risk to the load. The UPS will also continue to run if the control module has been removed ensuring that your critical loads are protected throughout all maintenance works are being fulfilled.

Page 26: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

24

E700 SeriesAn Advanced UPS Technology

3:3 Phase | 10 – 40kVA | 0.9PF

RELAY CARD SNMPIntelligent Slot options:

FEAtURES

3 High frequency, double conversion on-line technology

3 Fully digital microprocessor control

3 Parallel capacity or redundancy (maximum 4 units)

3 Wide input voltage range

3 Intelligent battery charge management

3 Automatic battery charge in UPS off mode

3 RS232 communication with monitoring software

3 Short circuit and overload protection

3 Lightning and surge protection

3 EMI and RFI noise filtering

3 Line interative ECO Mode

3 User friendly LCD interface

3 Cold start function

3 Built-in maintenance bypass switch

3 Emergency Power Off function

3 Relay alarm card fitted as standard

3 Optional SNMP network card available

3 Supplied with 36x 38Ah VRLA battery as standard

3 Alternative battery capacity / autonomy available

*NEW to the E Series Range

Page 27: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 25

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

The Dale E700 UPS is a state-of-the-art high frequency, double conversion on-line uninterruptible power supply with internal sealed VRLA battery, providing exceptionally high performance levels. Available in output power capacities of 10kVA, 15kVA, 20kVA, 30kVA and 40kVA, all with three phase input and output. The E700 series has been engineered to protect critical loads and processes that could be disrupted by power quality power or an unexpected break in the utility supply.

SPECIFICAtIONS

UPS Model E73310B E73315B E73320B E73330B E73340BCapacity 10KVA 15KVA 20KVA 30KVA 40KVA

9KW 13.5KW 18KW 27KW 36KW

Input Voltage Range 184V AC to 276V AC Line-Neutral

Phase 3 Phase 4 Wire & Earth

Frequency 40 – 70Hz

Power Factor ≥ 0.99

Output Voltage 220/230/240V AC Line-Neutral (user adjustable)

Phase 3 Phase 4 Wire & Earth

Frequency Range 50 / 60Hz (user adjustable)

THD (Linear Load) ≤ 2%

THD (Non-Linear Load) ≤ 5%

Waveform Sine wave

Overload Capability ≤110%: 60 mins, ≤125%: 10 mins, ≤150%: 1 min, ≥150% automatic shutdown of UPS

Crest Factor 3:1 (max)

Power Factor 0.9

Short Circuit Protection Yes

Transfer Time 0ms

Efficiency On-line mode: ≥95% Battery mode: ≥93%

Battery Type 12V valve regulated lead acid maintenance free

DC Voltage 384V - 480V DC (432V DC fitted as standard)

Battery 36x 12V / 38Ah

Backup Time At Half Load 150 min 90 min 60 min 35 min 25min

Backup Time At Full Load 60 min 35 min 25 min 12 min 8 min

Charge Current 6A (max)

Recharge Time Charge current can be set according to battery capacity installed

Environment Temperature 0°C to 40°C

Relative Humidity 0 – 95% (non-condensing)

Altitude 1500m maximum

Storage Temperature -25°C to 55°C

Communication Standard: RS232 Optional: SNMP

LCD Display Measurements: Input/output voltage/frequency, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass

LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation

Noise Level < 55dBA

Safety & EMC CE marked. Tested to EN/IEC 62040-1-1, EN/IEC62040-2, EN/IEC60950-1, IEC6100-4

Weight & Dimensions Standard Unit Weight 600kg 602kg 604kg 606kg 608kg

Dimensions (H × W × D) mm 1200 x 600 x 780 mm

Standard Accessories Relay alarm card Fitted as standard

SNMP network card Optional extra

Page 28: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

DSP Power Factor Corrected IGBT RectifierLatest IGBT power factor correction technology provides an input power factor close to unity (≥0.99) and input current total harmonic distortion (THDi) less than 3% to avoid disturbances to the connected loads.

DSP control systemThe digital signal processor controls the power-on, star-up, input power factor control, battery charging, output stage ac voltage regulation and shutdown control for the UPS system.

Parallel and Redundant OperationCapability to connect up to 4 units in parallel to provide increased power capacity or redundancy. As each UPS contains and internal battery, an increase in autonomy time is also achieved when units are connected in parallel. Automatic master/slave rotation is provided for additional reliability.

POWER INCREASEUnits can be connected in parallel to increase the total capacity of the system. When an inverter goes offline, the critical loads are automatically transferred to bypass.

REDUNDANCYUnits can be connected in parallel to provide redundancy for absolute reliability. In parallel redundant mode, the number of units (N) supply the load and an extra unit is provided in case of failure (N+1). All units share the load current equally. When a unit goes offline, due to failure or maintenance, the standby unit continues to supply the critical load without any interruption.

Back Feed ProtectionBack feed protection prevents current from the UPS output feeding back to the UPS input terminals, thereby protecting maintenance personnel from electrocution whilst working on the incoming supply side of the system.

Advanced Battery ManagementIntelligent precision charging principles guarantee enhanced battery life and maximum battery performance and reliability. This provides the reassurance that the battery is primed and ready for the critical role they play in your power protection system. Automatic adjustment of charging parameters based on the battery configuration entered via the LCD panel. Real-time battery management information is displayed on the LCD, such as battery capacity (as percentage or time remaining). Programmable automatic or manual battery tests can be performed without interruption to the UPS operation or load.

DSP Controlled IGBT InverterThe DSP controlled IGBT inverter provides a clean, true sine wave output voltage to deliver the highest quality power to protect critical loads.

Static & Manual (Maintenance) BypassStatic and manual bypass switches are included as standard, with operational characteristics as follows:StAtIC BYPASSThis feature provides a safe transfer to mains should the UPS be overloaded or develop a fault condition. The static switch contains electronically controlled switching circuits that enable the critical load to be connected to either the inverter output or to a bypass source via the static bypass line. During normal operation, the load is connected to the inverter, but in the event of a UPS overload or inverter failure, the load is automatically transferred

to the static bypass line. To provide a clean (no-break) load transfer between the inverter output and static bypass line, the static switch activates and connects the load to bypass. To achieve this, the inverter output and bypass are fully synchronised by the inverter control electronics.

MANUAL BYPASSThis feature is provided solely to allow maintenance work to be carried out on the UPS without interrupting the power to the load. The UPS can be powered down to enable technical personnel to replace parts. Full system replacement and repair of major components does however, necessitate shutdown of the load.

Discrete UPS Module DesignThe UPS design incorporates discrete rack mounted UPS module to facilitate quick and easy replacement for low Mean Time To Repair (MTTR). The UPS module can be exchanged with the protected load supplied by the internal maintenance bypass breaker.

Frequency Converter ModeThe UPS can also be used as a frequency converter. It can accept a 40Hz to 70Hz input frequency range and provide a stable 50Hz or 60Hz output frequency.

Excellent Generator CompatibilityThanks to the robust IGBT rectifier, the E700 series UPS is compatible with a diverse range of sources, including generators. High Input power factor (0.99) and low input current total harmonic distortion (THDi) <3% is achieved without compromising efficiency, allowing a modestly sized generator to be utilised. The E700 series includes a “power walk-in” feature that measures the UPS input current and gradually increases the power supplied from the utility source to the load.

26

E700 Seriesx 4

Page 29: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 27

APPLICAtION

Server, Telecommunications, Networking, Data Centre, IT, Financial, Emergency Services, Defence, Retail, Transportation, Broadcasting and Communications, Healthcare, Leisure and Sport, Government, Education

Lower Total Cost of OwnershipThe high efficiency operation of the UPS (>95% in on-line mode) means that less energy is consumed to supply power to the protected loads. As a result of reduced heat emission and power loss, users benefit from reduced electricity usage and air conditioning requirements. With low <3% THDi and high 0.99 input power factor, switchgear, circuit protection, cabling and generator requirements are minimised, thus reducing investment cost.

Advanced User InterfaceThe UPS operating information, status and parameter settings are accessed using the large user friendly, touch screen LCD and system LED mimic panel. The UPS stores 500 events on a rolling data log.

Green ECO Mode of OperationThe E700 series UPS can be operated in high efficiency ECO mode (97%) providing green energy savings through reduced power consumption.

Emergency Power Off (EPO)The EPO function is designed to switch off the UPS in an emergency situation (eg. fire, flood). Operation of the EPO turns off the rectifier and inverter and cuts power to the load immediately (both the inverter and bypass lines). The EPO also prevents the battery from charging or discharging.With the utility input supply present, the UPS control circuits remain energised, even though the output is turned off. To remove all power from the UPS, the external feeder breaker must be opened.

Auto Re-startWhen the utility source fails, the UPS draws power from the battery system to supply the load, until the batteries are depleted. Once the batteries reach their End of

Discharge threshold, the UPS will shut down. The UPS can be programmed to auto-recover after End of Discharge after a set variable delay time.

Cold Start OperationWhen the utility source is not available, the cold start feature enables the UPS to be started using the battery only.

Long Autonomy Compact SolutionEach E700 unit holds 36pcs of 12V/38Ah sealed, maintenance free VRLA batteries, providing extended back-up autonomy in the event of a mains failure. The compact design prevents the need for a separate battery cabinet, providing a very compact solution, ideal for applications where floor space is limited.

Advanced CommunicationsA wide range of advanced communication options are available:

RELAY ALARMS CARDIsolated, volt-free dry contacts indicate the UPS operating status and the presence of alarm conditions. Opto-isolated inputs allow the UPS to be controlled remotely.

RS232 SERIAL PORtThe UPS operating parameters can be observed and controlled locally using an RS232 communications port.

SNMP NEtWORk CARDEnables monitoring and control of the UPS operation by LAN or Internet connection. Allows the remote execution of scheduled events and the shutdown / reboot of the UPS and multiple servers. Full event log and data management. Real time notification of changes in UPS status reported to users by SMS or e-mail. Software supports Windows, Linux, Mac,

Free BSD and VM Ware operating systems. Accepts environmental monitoring inputs (temperature, humidity, water, smoke, security sensors).

Page 30: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

28

E800 SeriesAn Advanced UPS Technology

3:3 Phase | 10–600kVA | 0.8PF

FEAtURES

3 Cutting edge technology, high frequency double conversion on-line UPS

3 Fully digital microprocessor control

3 Parallel capacity or redundancy (maximum 4 units)

3 Wide input voltage and frequency range

3 Dual input as standard on 80kVA models and above

3 Open architecture design provides full access for servicing

3 Intelligent battery charge management

3 RS232/RS485 communication with monitoring software

3 Short circuit and overload protection

3 Over temperature and over humidity protection

3 EMI and RFI noise filtering

3 Line interactive ECO mode

3 Large user friendly LCD interface

3 Cold start and programmable auto re-start functions

3 Fan speed auto control with load variation

3 Built-in static and maintenance bypass switches

3 Back feed protection between UPS output and mains supply

3 Emergency Power Off function

3 Low THD and high input power factor for diverse generator compatibility

3 Soft start with programmable power walk-in

3 Optional temperature compensated battery charging

3 Optional SNMP, relay card and remote monitoring panel

*NEW to the E Series Range

RELAY CARD SNMP CARDIntelligent Slot options:

Page 31: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 29

The Dale E800 series is a ground breaking new generation of high frequency, on-line double conversion Uninterruptible Power Supplies. Full DSP controlled technology ensures continuous, clean, true sinusoidal power is delivered to critical applications under a wide range of conditions. Available in output power capacities from 10 through to 600kVA, all with three phase input and output. The engineering design is truly ingenious, combining leading-edge power electronics, software and mechanical design to achieve excellence on every level.

COMMON SPECIFICAtIONS

MODEL SPECIFICAtIONS

Input Voltage Range 187V AC to 260V AC Line-Neutral

Phase 3 Phase 4 Wire & Earth

Frequency 50 / 60Hz ±10% (user adjustable)

Power Factor ≥ 0.99

Output Voltage 220 / 230V AC Line-Neutral (user adjustable)

Phase 3 Phase 4 Wire & Earth

Frequency Range 50 / 60Hz (user adjustable)

THD (Linear Load) ≤ 2%

THD (Non-Linear Load) ≤ 3%

Efficiency On-line mode: 93% ECO mode: 98%

Overload Capability 125% load for 10 min, 150% load for 1 min

Crest Factor 3:1

Power Factor 0.8

Short Circuit Protection IGBT controlled electronic protection

Waveform True sine wave

Transfer Time 0ms (on-line mode)

Battery External 62x 12V mono blocks (744V DC Nominal Centre Tapped)

Environment Altitude 1000m at rated power

Operate Temperature 0ºC to 40ºC

Relative Humidity 0 - 95% (non-condensing)

Communication Standard: RS232 / RS485 Optional: SNMP and relay cards, remote monitoring panel

LCD Screen Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass

Operation Mode Double conversion on-line or ECO line interactive (user selectable)

LED Indication Mimic panel overview of UPS operation and alarms

Noise Level <60dBA

Safety & EMC CE marked and compliant with EN62040-1-1, IEC60950 & EN62040-2 standards

Standard Accessories Control software, data lead & user manual

Model Number Output Ratings Full Load Battery DC Audible Noise Physical (kVA) (kW) Efficiency Voltage (dBA) Nett Weight (kg) Dims (mm) (H x W x D)

E83310 10 8 93% 744V <60dBA 115 1190 x 460 x 805 E83315 15 12 93% 744V <60dBA 120 1190 x 460 x 805 E83320 20 16 93% 744V <60dBA 125 1190 x 460 x 805 E83330 30 24 93% 744V <60dBA 150 1190 x 460 x 805 E83340 40 32 93% 744V <60dBA 160 1190 x 460 x 805 E83360 60 48 93% 744V <60dBA 180 1190 x 460 x 805 E83380 80 64 93% 744V <60dBA 300 1660 x 880 x 770 E833100 100 80 93% 744V <60dBA 320 1660 x 880 x 770 E833120 120 96 93% 744V <60dBA 350 1660 x 880 x 770 E833160 160 128 93% 744V <60dBA 550 1905 x 1055 x 800 E833200 200 160 93% 744V <60dBA 575 1905 x 1055 x 800 E833250 250 200 93% 744V <60dBA 700 1900 x 1400 x 800 E833300 300 240 93% 744V <60dBA 750 1900 x 1400 x 800 E833400 400 320 93% 744V <60dBA 1250 1900 x 1250 x 805 E833500 500 400 93% 744V <60dBA 1600 1900 x 1750 x 850 E833600 600 480 93% 744V <60dBA 1800 1900 x 1750 x 850

Page 32: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

30

E800 Series

DSP Power Factor Corrected IGBT RectifierLatest IGBT power factor correction technology provides an input power factor close to unity (≥0.99) and input current total harmonic distortion (THDi) less than 3% to avoid disturbances to the connected loads. The high input power factor leads to reduced electricity consumption, minimised switchgear and circuit protection, cabling and generator requirements, thus reducing investment cost.

DSP Controlled IGBT InverterThe DSP controlled IGBT inverter provides a clean, true sine wave output voltage to deliver the highest quality power to protect critical loads. The DSP circuitry is embedded within a single control board to reduce hardware and improve noise immunity. Complex control algorithms are utilised with floating point controllers to ensure uninterrupted operation and protection of the loads in abnormal conditions that may cause failure. The DSP control system achieves fast dynamic response for non-linear loads and high power factor under various load conditions.

Parallel and Redundant OperationCapability to connect up to 16 units in parallel to provide increased power capacity or redundancy. All parallel units can be operated from the front panel of any UPS.

POWER INCREASEUnits can be connected in parallel to increase the total capacity of the system. When a unit goes out of order, the critical loads are automatically transferred to bypass.

REDUNDANCYUnits can be connected in parallel to provide redundancy for absolute reliability. In parallel redundant mode, the number of units (N) supply the load and an extra unit is provided in case of failure (N+1). All units share the load current equally. When a unit goes out of order, due to failure or maintenance, the standby unit continues to supply the critical load without any interruption.

Static & Manual (Maintenance) BypassStatic and manual bypass switches are included as standard, with operational characteristics as follows:

STATIC BYPASSThis feature provides a safe transfer to mains should the UPS be overloaded or develop a fault condition. The static switch contains electronically controlled switching circuits that enable the critical load to be connected to either the inverter output or to a bypass source via the static bypass line. During normal operation, the load is connected to the inverter, but in the event of a UPS overload or inverter failure, the load is automatically transferred to the static bypass line. To provide a clean (no-break) load transfer between the inverter output and static bypass line, the static switch activates and connects the load to bypass. To achieve this, the inverter output and bypass are fully synchronised by the inverter control electronics.

MANUAL BYPASSThis feature is provided solely to allow maintenance work to be carried out on the UPS without interrupting the power to the load. The UPS can be powered down to enable technical personnel to replace parts. Full system replacement and repair of major components does however, necessitate shutdown of the load.

Advanced Battery ManagementIntelligent precision charging principles guarantee enhanced battery life and maximum battery performance and reliability. This provides the reassurance that the battery is primed and ready for the critical role they play in your power protection system. Automatic adjustment of charging parameters based on the battery configuration entered via the LCD panel.Real-time battery management information is displayed on the LCD, such as battery capacity (as percentage or time remaining).Temperature compensated battery charging monitors are available to monitor the internal

and external battery temperature with a feedback control loop to adjust the charge current rate accordingly. Programmable automatic or manual battery tests can be performed without interruption to the UPS operation or load. The batteries can also be ‘hot-swapped’ without disconnection of the UPS.

Single or Dual Source Operation (Optional)To increase flexibility, the UPS input can be fed by single or dual sources. In dual configuration, the rectifier is fed from the utility (main source) and the static and maintenance bypass are fed from a secondary source.

Open Architecture DesignThe UPS incorporates an open architecture design to facilitate full access to replace parts quickly and easily, resulting in low Mean Time To Repair (MTTR).

Perfect Generator CompatibilityThanks to the robust IGBT rectifier, the E800 series UPS is uniquely compatible with a diverse range of sources, in particular, generators. Input current total harmonic distortion (THDi) of less than 3% is achieved without compromising efficiency. The high input power factor enables a generator to be utilised with a power rating only 20% higher than the UPS.Power walk-in can be adjusted from 5 to 15 seconds. Based on the current measured on the input, the UPS gradually increases the power supplied from the utility source to the load. This power delivered by the utility source to the load varies according to the input voltage, current and power factor.

Emergency Power Off (EPO)The EPO function is designed to switch off the UPS in an emergency situation (eg. fire, flood). Operation of the EPO turns off the rectifier and inverter and cuts power to the load immediately (both the inverter and bypass lines). The EPO also prevents the battery from charging or discharging.

x 4

Page 33: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 31

APPLICAtION

Server, Telecommunications, Networking, Data Centre, IT, Financial, Emergency Services, Defence, Retail, Transportation, Broadcasting and Communications, Healthcare, Leisure and Sport, Government, Education

With the utility input supply present, the UPS control circuits remain energised, even though the output is turned off. To remove all power from the UPS, the external feeder breaker must be opened.

Back Feed Protection (Optional)Back feed protection prevents current from the UPS output feeding back to the UPS input terminals, thereby protecting maintenance personnel from electrocution whilst working on the incoming supply side of the system.

Reverse Energy Tolerance for Regenerative LoadsThe E800 series UPS is suitable for use with regenerative loads, such as synchronous motors. Regenerative loads pump energy back to the mains supply. Traditionally, UPS systems would burn this feedback energy, resulting in lower operating efficiency. The IGBT rectifier in the E800 series UPS is capable of absorbing intermittent load generated power. This reverse power tolerance facilitates the execution of important system operations, such as closed transition transfers of the UPS load directly to an engine generator source.

Auto Re-startWhen the utility and bypass sources fail, the UPS draws power from the battery system to supply the load, until the batteries are depleted. Once the batteries reach their End of Discharge threshold, the UPS will shut down. The UPS will automatically re-start once the utility power is restored and output power to the load will be enabled. The UPS also incorporates a programmable automatic start time delay.

Advanced CommunicationsA wide range of advanced communication options are available:

EXTERNAL BATTERY TEMPERATURE SENSOROne module is fitted to each external battery cabinet to monitor the battery temperature. A feedback control loop within the UPS adjusts the charge current based on the battery temperature, optimising battery performance and longevity.

RELAY ALARMS CARDIsolated volt-free dry contacts indicate the UPS operating status and the presence of alarm conditions. Fully programmable to facilitate the capture of a diverse range of operating and alarm conditions. Opto-isolated inputs allow the UPS to be controlled remotely.

RS232/RS485 SERIAL PORTThe UPS operating parameters can be observed and controlled locally using an RS232/RS485 communications port. Real time notification of changes in UPS status reported to users by SMS or e-mail.

SNMP NETWORK CARDEnables monitoring and control of the UPS operation by LAN or Internet connection. Allows the remote execution of scheduled events and the shutdown / reboot of the UPS and multiple servers. Full event log and data management. Real time notification of changes in UPS status reported to users by audible alarm, SMS or e-mail. Software supports Windows, Linux, Mac, Solaris, Open VMS and IBM operating systems.

REMOTE LCD & LED MIMIC PANELFacilitates the monitoring and control of the UPS operations, events and parameters from a remote location.

Lower Total Cost of OwnershipThe high efficiency operation of the UPS means that less energy is consumed to supply power to the protected loads. As a result of reduced heat emission and power loss, users benefit from reduced electricity usage and air conditioning requirements.With reduced THDi and high 0.99 input power factor, switchgear, circuit protection, cabling and generator requirements are minimised, thus reducing investment cost.

Advanced User InterfaceThe UPS operating information and parameter settings are displayed in 4 different languages and can be accessed using the large user friendly, data rich LCD and system LED mimic panel. The UPS is capable of recording up to 500 events.

Green ECO Mode of OperationThe E800 series UPS can be operated in high efficiency ECO mode (98%) providing green energy savings through reduced power consumption.

Page 34: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

32

E900 SeriesAn Advanced UPS Technology

3:3 Phase | 10–200kVA | 0.9PF

FEAtURES

3 Latest technology, high frequency double conversion on-line UPS

3 3 level inverter and rectifier design achieves >96% efficiency

3 Fully digitised microprocessor control

3 Parallel capacity or redundancy (maximum 4 units)

3 Wide input voltage and frequency range switches

3 Open architecture design provides full access for servicing

3 Intelligent battery charge management

3 RS232/RS485 communication with monitoring software

3 Short circuit and overload protection

3 Over temperature and over humidity protection

3 EMI and RFI noise filtering

3 Line interactive ECO mode

3 Dual input facility for utility and bypass supplies

3 Large user friendly LCD interface

3 Programmable auto re-start functions

3 Fan speed auto control with load variation

3 Built-in static and maintenance bypass

3 Optional back feed protection between UPS output and mains supply

3Emergency Power Off function

3 Low THD and high input power factor for diverse generator compatibility

3 Soft start with programmable power walk-in

3 Optional temperature compensated battery charging

3 Optional SNMP, relay card and remote monitoring

3 Optional galvanic isolation transformer

96%Efficiency

at half load

*NEW to the E Series Range

RELAY CARD SNMP CARDIntelligent Slot options:

Page 35: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 33

The Dale E900 series is a fresh wave of ultra-efficient, high frequency, on-line double conversion Uninterruptible Power Supplies. Boasting an incredible 96% efficiency in on-line mode and 98% in green ECO mode, the E900 series UPS will reduce your energy consumption and the total cost of ownership for your site. Full DSP controlled technology ensures continuous, clean, pure sinusoidal power is delivered to critical applications under a wide range of conditions. Available in output power capacities from 10 through to 200kVA, all with three phase input and output at 0.9 power factor as standard. The E900 series is a pioneering marvel, pushing the boundaries of engineering design into a new class.

COMMON SPECIFICAtIONS

MODEL SPECIFICAtIONS

Input Voltage Range 187V AC to 260V AC Line-Neutral

Phase 3 Phase 4 Wire & Earth

Frequency 50 / 60Hz ±10% (user adjustable)

Power Factor ≥ 0.99

Output Voltage 220 / 230V AC Line-Neutral (user adjustable)

Phase 3 Phase 4 Wire & Earth

Frequency Range 50 / 60Hz (user adjustable)

THD (Linear Load) ≤ 2%

THD (Non-Linear Load) ≤ 6%

Efficiency On-line mode: 96% ECO mode: 98%

Overload Capability 125% load for 10 min, 150% load for 1 min

Crest Factor 3:1

Power Factor 0.9

Short Circuit Protection IGBT controlled electronic protection

Waveform True sine wave

Transfer Time 0ms (on-line mode)

Battery External 62x 12V mono blocks (744V DC Nominal Centre Tapped)

Environment Altitude 1000m at rated power

Operate Temperature 0ºC to 40ºC

Relative Humidity 0 - 95% (non-condensing)

Communication Standard: RS232 / RS485 Optional: SNMP and relay cards, remote monitoring panel

LCD Screen Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass

Operation Mode Double conversion on-line or ECO line interactive (user selectable)

LED Indication Mimic panel overview of UPS operation and alarms

Noise Level <65dBA

Safety & EMC CE marked and compliant with EN62040-1-1, IEC60950 & EN62040-2 standards

Standard Accessories Control software, data lead & user manual

Model Number Output Ratings Full Load Battery DC Physical (kVA) (kW) Efficiency Voltage Nett Weight (kg) Dims (mm) (H x W x D)

E93310 10 9 96% 744V 115 1190 x 460 x 805 E93315 15 13.5 96% 744V 120 1190 x 460 x 805 E93320 20 18 96% 744V 125 1190 x 460 x 805 E93330 30 27 96% 744V 150 1190 x 460 x 805 E93340 40 36 96% 744V 160 1190 x 460 x 805 E93360 60 54 96% 744V 180 1190 x 460 x 805 E93380 80 72 96% 744V 300 1660 x 880 x 770 E933100 100 90 96% 744V 320 1660 x 880 x 770 E933120 120 108 96% 744V 350 1660 x 880 x 770 E933160 160 144 96% 744V 550 1905 x 1055 x 800 E933200 200 180 96% 744V 575 1905 x 1055 x 800

Page 36: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

High efficiency & low total cost of ownershipUsing the latest three level rectifier and inverter technology, the E900 series achieves the highest levels of efficiency in power conversion (96% at ≥40% loading) which results in the lowest possible levels of energy loss. This provides considerable cost savings in comparison to a conventional design UPS. As a result of reduced heat emission and power loss, users benefit from reduced electricity usage and air conditioning requirements.

E900 UPS EFFICIENCY COMPARED tO

CONVENtIONAL MODEL

High Output power factorWith an output power factor of 0.9, the E900 series UPS can deliver up to 15% more active power compared to older technology Uninterruptible Power Supplies. This is achieved at 0.9 lagging, 1.0 unity and 0.9 leading power factor without any de-rate in active power.

0.9 POWER FACtOR OPERAtION WItHOUt DERAtE

DSP Power Factor Corrected IGBT RectifierLatest IGBT power factor correction technology provides an input power factor close to unity (≥0.99) and input current total harmonic distortion (THDi) less than 3% to avoid disturbances to the connected loads. The high input power factor leads to reduced electricity consumption, minimised switchgear and circuit protection, cabling and generator requirements, thus reducing investment cost.

DSP Controlled IGBT InverterThe DSP controlled IGBT inverter provides a clean, true sine wave output voltage to deliver the highest quality power to protect critical loads. The DSP circuitry is embedded within a single control board to reduce hardware and improve noise immunity. Complex control algorithms are utilised with floating point controllers to ensure uninterrupted operation and protection of the loads in abnormal conditions that may cause failure. The DSP control system achieves fast dynamic response for non-linear loads and high power factor under various load conditions.

Parallel and Redundant OperationCapability to connect up to 16 units in parallel to provide increased power capacity or redundancy. All parallel units can be operated from the front panel of any UPS.

POWER INCREASEUnits can be connected in parallel to increase the total capacity of the system. When a unit goes out of order, the critical loads are automatically transferred to bypass.

REDUNDANCYUnits can be connected in parallel to provide redundancy for absolute reliability. In parallel redundant mode, the number of units (N) supply the load and an extra unit is provided in case of failure (N+1). All units share the load current equally. When a unit goes out of order, due to failure or maintenance, the standby unit continues to supply the critical load without any interruption.

Static & Manual (Maintenance) BypassStatic and manual bypass switches are included as standard, with operational characteristics as follows:

STATIC BYPASSThis feature provides a safe transfer to mains should the UPS be overloaded or develop a fault condition. The static switch contains electronically controlled switching circuits that enable the critical load to be connected to either the inverter output or to a bypass source via the static bypass line. During normal operation, the load is connected to the inverter, but in the event of a UPS overload or inverter failure, the load is automatically transferred to the static bypass line. To provide a clean (no-break) load transfer between the inverter output and static bypass line, the static switch activates and connects the load to bypass. To achieve this, the inverter output and bypass are fully synchronised by the inverter control electronics.

MANUAL BYPASSThis feature is provided solely to allow maintenance work to be carried out on the UPS without interrupting the power to the load. The UPS can be powered down to enable technical personnel to replace parts. Full system replacement and repair of major components does however, necessitate shutdown of the load.

Advanced Battery ManagementIntelligent precision charging principles guarantee enhanced battery life and maximum battery performance and reliability. This provides the reassurance that the battery is primed and ready for the critical role they play in your power protection system. Automatic adjustment of charging parameters based on the battery configuration entered via the LCD panel. Real-time battery management information is displayed on the LCD, such as battery capacity (as percentage or time remaining). Temperature compensated battery charging monitors are available to monitor the internal and external battery temperature with a feedback control loop to adjust the charge current rate accordingly. Programmable automatic or

34

E900 Series x 4

Page 37: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 35

manual battery tests can be performed without interruption to the UPS operation or load. The batteries can also be ‘hot-swapped’ without disconnection of the UPS.

Perfect Generator CompatibilityThanks to the robust IGBT rectifier, the E900 series UPS is uniquely compatible with a diverse range of sources, in particular, generators. Input current total harmonic distortion (THDi) of less than 3% is achieved without compromising efficiency. The high input power factor enables a generator to be utilised with a power rating only 20% higher than the UPS. Power walk-in can be adjusted from 5 to 15 seconds. Based on the current measured on the input, the UPS gradually increases the power supplied from the utility source to the load. This power delivered by the utility source to the load varies according to the input voltage, current and power factor.

Emergency Power Off (EPO)The EPO function is designed to switch off the UPS in an emergency situation (eg. fire, flood). Operation of the EPO turns off the rectifier and inverter and cuts power to the load immediately (both the inverter and bypass lines). The EPO also prevents the battery from charging or discharging. With the utility input supply present, the UPS control circuits remain energised, even though the output is turned off. To remove all power from the UPS, the external feeder breaker must be opened.

Reverse Energy Tolerance for Regenerative LoadsThe E900 series UPS is suitable for use with regenerative loads, such as synchronous motors. Regenerative loads pump energy back to the mains supply. Traditionally, UPS systems would burn this feedback energy, resulting in lower operating efficiency. The IGBT rectifier in the E900 series UPS is capable of absorbing intermittent load generated

power. This reverse power tolerance facilitates the execution of important system operations, such as closed transition transfers of the UPS load directly to an engine generator source.

Auto Re-startWhen the utility and bypass sources fail, the UPS draws power from the battery system to supply the load, until the batteries are depleted. Once the batteries reach their End of Discharge threshold, the UPS will shut down. The UPS will automatically re-start once the utility power is restored and output power to the load will be enabled. The UPS also incorporates a programmable automatic start time delay.

Advanced CommunicationsA wide range of advanced communication options are available:

EXTERNAL BATTERY TEMPERATURE SENSOROne module is fitted to each external battery cabinet to monitor the battery temperature. A feedback control loop within the UPS adjusts the charge current based on the battery temperature, optimising battery performance and longevity.

RELAY ALARMS CARDIsolated volt-free dry contacts indicate the UPS operating status and the presence of alarm conditions. Fully programmable to facilitate the capture of a diverse range of operating and alarm conditions. Opto-isolated inputs allow the UPS to be controlled remotely.

RS232/RS485 SERIAL PORTThe UPS operating parameters can be observed and controlled locally using an RS232/RS485 communications port. Real time notification of changes in UPS status reported to users by SMS or e-mail.

SNMP NETWORK CARDEnables monitoring and control of the UPS operation by LAN or Internet connection.

Allows the remote execution of scheduled events and the shutdown / reboot of the UPS and multiple servers. Full event log and data management. Real time notification of changes in UPS status reported to users by audible alarm, SMS or e-mail. Software supports Windows, Linux, Mac, Solaris, Open VMS and IBM operating systems.

REMOTE LCD & LED MIMIC PANELFacilitates the monitoring and control of the UPS operations, events and parameters from a remote location.

Advanced User InterfaceThe UPS operating information and parameter settings are displayed in 4 different languages and can be accessed using the large user friendly, data rich LCD and system LED mimic panel. The UPS is capable of recording up to 500 events.

Green ECO Mode of OperationThe E900 series UPS can be operated in high efficiency ECO mode (98%) providing green energy savings through reduced power consumption.

APPLICAtION

Server, Telecommunications, Networking, Data Centre, IT, Financial, Emergency Services, Defence, Retail, Transportation, Broadcasting and Communications, Healthcare, Leisure and Sport, Government, Education

Page 38: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

36

Could your business cope without power?Power interruptions are costly to every business Regardless of whether the origin is a short or long interruption, a voltage dip, a transient or other voltage disturbance, the consequence is an outage. Interruption duration is important but much more so is the frequency of power quality problems and the serious impact they may have on your businesses ability to operate.

It is estimated that power quality problems cost industry and commerce in the EU about 10 billion per annum while expenditure on preventative measures is less than 5 % of this. The question is the obvious one: ‘How much money should be invested in prevention to balance the risk of failure?’ and the answer depends on the nature of the business.

How much money do I risk to lose with each fault?

Handbook of Power Quality, By Angelo Baggini, 2008, P. 6558

Any malfunction or wear to the UPS systems components reduces the availability of its power. It’s critical that you maintain your UPS SYSTEMS to ensure that if there is a mains failure they continue to operate, and your sensitive IT equipment isn’t damaged.

Regular checks of your UPS and generator will help ensure that they haven’t developed any faults, and identify and rectify potential issues. If you neglect UPS maintenance, you put your business continuity strategy at risk. Even the best UPS system is subjected to wear and tear.

How can I save money and prevent power faults?A UPS system from Dale Power Solutions with a remote monitoring system avoids human error, by taking human supervision out of the equation. By using Dale Power Solutions remote monitoring system (sentry) and a receptive and high level of after sales, it is possible to:

3 Prevent the faults before they become evident from early detections

3 For technicians to be properly equipped with any necessary spare parts

3 To contact the most relevant technicians

3 To remind periodical and preventative maintenance

3 To avoid human errors

tABLE 1.1 COSt OF VOLtAgE DIPS

Industry Duration Cost/sag

Uk Steelworks 30% fo 3.5 cycles £250 000

US glass plant Less than 1 s €200 000

US computer center 2 s €600 000

US car plant Annual exposure €10m

South Africa (country) Annual exposure €3bn

tABLE 1.2 COSt OF VOLtAgE DIPS (Reproduced From Leonardo Power Quality Application guide - Part 2.1, Copper Development Association)

Industry typcial financial loss per event (€000)

Semiconductor production 3800

Financial trading 6000 per hour

Computer center 750

telecommunications 30 per minute

Steelworks 350

glass manufacture 250

Page 39: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 37

Who’s looking after your power system when you’re not there?A fast and reliable maintenance service is the best solution to maintaining high system availability for the entire life cycle. Dale Power Sentry ensures 24/7 continuous monitoring of your UPS, preventing human errors and preventing faults from the outset of symptoms.

Remote monitoring is the key

What is remote monitoring?Dale Power Sentry (DPS) is a remote monitoring service designed to ensure your business’ critical load is protected by dedicated, trained personnel, even when your facility is unmanned.

Benefits include:The E series UPS is suitable for a wide range of applications. The flexibility of the UPS is achieved through its many options, including battery type, single or multi-unit configuration, and accessories.

3 Complete peace of mind

3 Minimises risks to the customers’ business

3 Continuous 24 hour monitoring the health of your UPS

3 Rapid problem analysis and resolution

3 Secure access to all of your system data at all times

3 Ideal for mission critical systems and unmanned sites

We do far more than simply monitor your UPSUsing the data from your UPS we can improve the life of your UPS battery systems by:

3 Analysing and tracking the performance of your UPS

3 Predicting potential failure of your UPS

3 Watching the condition of your batteries and UPS in real time

3 Ensure the availability of your facility’s power system

How does Remote Monitoring work?

3 The UPS is fitted with an SNMP card to allow remote monitoring. (Simple Network Management Portal)

3 Once the SNMP card is installed it talks back to the hosts UPS extracting information from the UPS allowing it to be remotely monitored.

3 Our servers will continually monitor your UPS and record all essential data and specified alarms.

3 Any alarm that is produced is immediately evaluated within our system which then transmits an alarm notification to your designated company contact via email.

3 Our service team is notified and will analyse the data, and if required a service engineer will be dispatched to take care of any faults.

3 We provide 24/7 nationwide remote monitoring service – keeping your power in safe hands.

Page 40: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

38

The Total Secure Power SolutionSince 1935, Dale Power Solutions has been providing customers around the world with technical excellence in providing technologically advanced product solutions, expertly project managed and supported by tailored service packages.

UPS and generator together – true ‘no break’ solutionOur total secure power solution integrates UPS and generator together where the UPS supports critical loads without interruption until the generator kicks in.

With our “no-break” power solution we can ensure your business continuity without costly downtime.

Remote monitoring – users can monitor multiple systems, alarms, fault signals and fuel systems from a single PC or mobile device.

Page 41: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com 39

We provide nationwide service and maintenance contracts for all our UPS products and have a variety of preventive maintenance agreements that are designed to suit your system’s needs.

Wherever your equipment is required or located – from the roof to the basement, in the desert or off shore – we have the expertise to provide the perfect installation, service and maintenance solution.

Planned preventative maintenance Scheduled inspections agreed to your requirements

Database management We can manage all your equipment to ensure it is maintained to schedule

Lifecycle management Optimising the operational cost and reducing capital outlay by upgrading or refurbishing both our own brand and other OEM equipment keeping it running longer

Waste disposal Providing environmentally ethical and compliant disposal and recycling services

Our Service portfolio includes:

3 Standard and bespoke maintenance/ service contracts

3 System upgrades and modifications

3 Hire solutions: diesel generators, UPS, Load bank, batteries

3 Temporary battery and secure power system hire

3 Management of turnkey projects

3 Individually tailored training (in factory or on site)

3 Site surveys

3 Installation and commissioning

3 Independent advice on all aspects of standby power and batteries

Our highly-skilled and qualified engineers have off-shore certification, enabling us to work on oil and gas platforms as well as terrestrial installations world-wide.

We offer a 24 hour, 365 days per year call out facility that is second to none. Your first point of contact will be with a member of our own Service team, not a call centre. This guarantees you a customised service and an immediate reaction facilitated by our nationwide team of engineers.

UPS Service and Support

Page 42: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

40

Dale Power Solutions

Corporate & Social ResponsibilityOperating in a responsible and sustainable manner is important to Dale Power Solutions. Whilst we run our business in line with the expectations of our stakeholders, we also see corporate responsibility as a discipline that helps us to manage risks and maximise on the opportunities presented to us in a changing world.

We take our corporate responsibility seriously across the Company as an employer, manufacturer, investor and a consumer. We are committed to understanding, monitoring and managing our social, environmental and economic impact to enable us to contribute to society’s wider goal of sustainable development. We aim to demonstrate these responsibilities through our actions and within our corporate policies.

EnvironmentWe recognise the importance of understanding the impact of our activities on the environment and we are developing an Environmental Programme to demonstrate and benchmark our commitment. Our company is accredited to ISO 14001 and we are continually looking at ways to improve our efficiency across our sites. We promote energy and water efficiency, waste reduction, and reduction of potentially dangerous, volatile or environmentally damaging chemicals. We also have an ongoing commitment to reducing our carbon footprint.

Health & SafetyWe shall provide, and strive to maintain, a clean, healthy and safe working environment. Providing a workplace where our employees feel safe is not only a legal obligation, but a fundamental factor in building their engagement with the company. Through management intervention, awareness campaigns and a culture that encourages employees to raise concerns about the workplace safety, we aim to reduce the frequency of accidents.

Our SHE Team promotes and develops cooperation between all employees to ensure health and safety management is embedded into management and business processes. This is supported by our Health & Safety Policy.

CommunityWe are committed to making a sustainable positive impact on the communities in which we operate. We aim to make a distinctive contribution to equality and social development through the establishment of effective partnerships and programmes that make best use of the energies and skills of our employees. We support our employees in fundraising for charities and voluntary work, recognising both the benefit to the community and to the employees themselves.

Page 43: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com

Setting New Standards…The Dale brand provides the benchmark in UPS power solutions for diverse global markets including:

3 Data Centres

3 Financial

3 Commercial

3 Retail

3 Medical

An unmatched history of continued supply of secure power solutions for the most demanding requirements worldwide, providing total customer satisfaction.

The E Series UPS Secure Power Solution

DA

U

L

P

E

S

Dependable and reliable

Advanced power solutions

Unrivalled installation and support

Leading edge technology

Precision power management

Ethical and environmentally friendly

Secured business continuity

41

Page 44: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

42

Our range of generator solutions provides you with dependable power no matter what business you are in. We also provide a comprehensive range of elective accessories and supply ancillary items as standard or custom designed to meet your specific site requirements. We design and supply a full collection of generator control systems with guaranteed flexibility providing total control of your installations.

Secure Power when you need itDale Power Solutions Secure Power Series offers a full range of diesel generators with power output ranging from 7.5 kVA to 3,300 kVA and beyond and gas turbine repackaging capabilities.

Secure+ offers a pre-designed range of containerised diesel generators from 500kVA to 2500kVA applicable to both permanent and temporary applications.

For endless custom-designed generator solutions Secure∞ is a range of innovative engineering solutions that meets the most challenging application requirements. With open and containerised diesel generators from 500kVA to 3300kVA and beyond and gas turbine repackaging projects our team of expert engineers are with you every step of the way working to your specific requirements.

Secure is a range of diesel generators with open and canopied options from 7.5kVA to 3000kVA. Available with rapid product availability, proven reliability, operational flexibility and low lifecycle costs.

Page 45: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com

Summary of our Industrial UPS AC and DC systems

43

The E900 series is a pioneering marvel, pushing the boundaries of engineering design into a new class. Full DSP controlled technology ensures continuous, clean, pure sinusoidal power is delivered to critical applications under a wide range of conditions.

Industrial AC UPS systems are available with integral rectifier, inverter and static transfer switch or as modular solutions using compact and customisable rack mounted units.

All our AC & DC Systems may be custom designed and configured to meet clients exact and demanding requirements for virtually all industrial applications, providing security of power for your critical loads:

3 Dual or N+1 redundancy of power systems and batteries

3 Bespoke enclosure sizes

3 Increased protection ratings

3 Configurable alarm and system monitoring schemes

3 Customer specific distribution

3 Battery cell monitoring

Complex industrial UPS projects require management - Dale has a team of PROJECT MANAGERS who will plan, control and co-ordinate all activities involved with delivering the solution from order placement through to design, manufacture, installation and commissioning.

Proven DesignAll of our industrial secure power solutions, under the Erskine brand, are proven as robust and reliable with many years of operation in arduous environments from offshore to the heat of the desert, from marine to rail; something you can rely on.

BatteriesDale Power Solutions is one of the largest suppliers of batteries in the UK. Whether the battery is part of an integrated solution from Dale or simply a replacement battery for your existing system, Dale Power Solutions will select and design the optimal battery solution for the project application. We can satisfy you’re every requirement from individual cells or mono-blocks and accessories to full battery banks, strings and entire sites.

Open Architecture DesignThe UPS incorporates an open architecture design to facilitate full access to replace parts quickly and easily, resulting in low Mean Time To Repair (MTTR).

Page 46: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

E Series UPS Secure Power

44

Established since 1935, Dale Power Solutions has become a global leader in bringing technology and engineering together to create innovative solutions, protecting critical power supplies for customers through our standby power systems.

With an annual turnover in excess of £30 million, it is through our commitment to excellence, combined with our mission to deliver outstanding client service has earned Dale Power Solutions its prestigious reputation it enjoys today as one of the world’s most trusted providers of secure power solutions.

Dale Power Solutions provides a comprehensive and bespoke design capability service to our customers, taking initial concepts through design, project management, manufacturing, installation and commissioning processes, followed by complete maintenance and servicing on a worldwide basis to more than 8,000 generators and UPS systems. Our professional structure, financial strength and the necessary quality assurance, health and safety, and product accreditations meet the demands of the world’s most discerning clients. These accreditations include:

Proud of our pedigree… proud to be your partner.

Dale Power Solutions –

Delivering secure back-up power across the globe

Certificate No.: UK.1498800 Certificate No.: UK.002663/E Certificate No.: UK.1498800

Page 47: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com

Dale E Series UPS Secure Power

Business power continuity guaranteed

www.dalepowersolutions.com

Page 48: YOUR POWER IN SAFE HANDS UPS catalogue 2015s3.amazonaws.com/yourguide-production-assets/... · 39 UPS Service & Support ... Your system is in expert hands. Project managers work ...

www.dalepowersolutions.com

MIDDLE EASt BRANCH

Tel: +971 4 364 1228

HEAD OFFICE, FACtORY 1, SCARBOROUgH

Salter RoadEastfield Industrial Estate

ScarboroughNorth Yorkshire

YO11 3DU

Tel : + 44 (0) 1723 583511

prod

uced

by

adve

rset

med

ia s

olu

tio

ns li

mit

ed w

ww

.adv

erse

t.co

.uk

Dale Power Solutions Ltd

FACtORY 2, FILEY

Tel : + 44 (0) 1723 583511

SCOtLAND BRANCH

Tel: + 44 (0) 1224 270 391

Uk SOUtHERN BRANCH