XRF SCREENING AND CHEMICAL CONFIRMATION TEST ...Intertek Testing Services Shenzhen Ltd.-TFH Division...
Transcript of XRF SCREENING AND CHEMICAL CONFIRMATION TEST ...Intertek Testing Services Shenzhen Ltd.-TFH Division...
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
AUTHORIZED BY: FOR INTERTEK TESTING SERVICES SHENZHEN LTD.
KARBON M.Y. WU GENERAL MANAGER
PAGE 1 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
APPLICANT: FUYUAN ELECTRONIC CO., LTD. DATE: Apr 08, 2010 XIEWU VILLAGE, HENGSHAN, SHIPAI TOWN,
DONGGUAN, GUANGDONG, CHINA
SAMPLE DESCRIPTION:
ONE (1) SUBMITTED SAMPLE SAID TO BE AC SWITCHING ADAPTOR. APPLICANT'S REF. : FYXXXXYYYY SERIES.
************************************************************************************* TESTS CONDUCTED: AS REQUESTED BY THE APPLICANT, FOR DETAILS REFER TO ATTACHED PAGE(S) ************************************************************************************* CONCLUSION:
TESTED SAMPLES STANDARD RESULT SCREENED COMPONENTS OF SUBMITTED SAMPLE
SCREENING BY XRF SPECTROSCOPY AND CHEMICAL CONFIRMATION TEST FOR RoHS DIRECTIVE (2002/95/EC)
PASS
************************************************************************************ REMARK : THE CHEMICAL CONFIRMATION TESTS OF COMPONENTS (41a), (43), (55a), (57a), (63a),
(73) WERE CONDUCTED BASED ON SAMPLES RECEIVED ON APR 03, 2010. ************************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 2 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
DETERMINATION OF LEVELS OF REGULATED SUBSTANCES IN ELECTROTECHNICAL PRODUCTS, ELEMENTS OF CADMIUM (Cd), LEAD (Pb), MERCURY (Hg), CHROMIUM (Cr) AND BROMINE (Br) CONTENT WERE MEASURED BY XRF SPECTROSCOPY AND CHEMICAL CONFIRMATION TEST FOR RoHS RESTRICTED SUBSTANCES.
(A) RESULTS :
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
1.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 2.
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 3.
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
4.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
5.
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 3 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr DETECTED 6.
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
7.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 8.
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
9.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 10.
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
11.
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 4 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
12.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
13.
Br DETECTED
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
14.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
15.
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND
16.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
17.
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 5 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND 18.
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr DETECTED 19.
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
20.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
21.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 22.
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr DETECTED 23.
Br NA
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 6 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr DETECTED 24.
Br NA
NOT TESTED
Cd ND
Pb >1500 mg/kg #
Hg ND
Cr ND
25(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 25(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 26.
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
27.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
28(a).
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 7 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND 28(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
29.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
30.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
31(a).
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND 31(b).
Br NA
NOT TESTED
Cd ND
Pb DETECTED
Hg ND
Cr ND 31(c).
Br NA
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 8 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
32(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
32(b).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
32(c).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 32(d).
Br NA
NOT TESTED
Cd ND
Pb >1500 mg/kg #
Hg ND
Cr ND
33(a).
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND 33(b).
Br NA
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 9 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
34(a).
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND
34(b).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
34(c).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 34(d).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
35(a).
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND
35(b).
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 10 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
35(c).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 35(d).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
36(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 36(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
36(c).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
36(d).
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 11 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND 36(e).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 36(f).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 36(g).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
36(h).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
37(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 37(b).
Br NA
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 12 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
38.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
39(a).
Br ND
NOT TESTED
Cd ND
Pb DETECTED
Hg ND
Cr ND 39(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 39(c).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 39(d).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 39(e).
Br NA
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 13 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
39(f).
Br ND
NOT TESTED
Cd ND
Pb >1500 mg/kg #
Hg ND
Cr ND
40(a).
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND 40(b).
Br NA
NOT TESTED
Cd ND
Pb >1500 mg/kg #
Hg ND
Cr ND 41(a).
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND 41(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
42(a).
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 14 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND 42(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
43.
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND
44(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 44(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
45.
Br DETECTED
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
46(a).
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 15 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
46(b).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
46(c).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 46(d).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
46(e).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
46(f).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
46(g).
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 16 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND 46(h).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
46(i).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
46(j).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
46(k).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
46(l).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
46(m).
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 17 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
46(n).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
46(o).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 47.
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
48(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 48(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
48(c).
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 18 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
48(d).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 48(e).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 48(f).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 48(g).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
49(a).
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND 49(b).
Br NA
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 19 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
50(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 50(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 50(c).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
51(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 51(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
52(a).
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 20 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
52(b).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr DETECTED 52(c).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 52(d).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
53(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 53(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
54.
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 21 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
55(a).
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND 55(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 56.
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
57(a).
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND 57(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr DETECTED
58(a).
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 22 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND 58(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
59(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 59(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
60.
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
61(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 61(b).
Br NA
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 23 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
62(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 62(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
63(a).
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND 63(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
64(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 64(b).
Br NA
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 24 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
65(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 65(b).
Br NA
NOT TESTED
Cd ND
Pb DETECTED
Hg ND
Cr ND
66(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
66(b).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 66(c).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
67(a).
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 25 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND 67(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr DETECTED
68(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 68(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
69(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 69(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
69(c).
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 26 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
69(d).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 69(e).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 69(f).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 69(g).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
69(h).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
70.
Br ND
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 27 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
71(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 71(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
71(c).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
71(d).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 71(e).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 71(f).
Br NA
NOT TESTED
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 28 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND 71(g).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
71(h).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
72(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
72(b).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 72(c).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
73.
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 29 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS XRF RESULTS CHEMICAL
CONFIRMATION RESULT
Cd ND
Pb ND
Hg ND
Cr ND
74(a).
Br ND
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND 74(b).
Br NA
NOT TESTED
Cd ND
Pb ND
Hg ND
Cr ND
75.
Br INCONCLUSIVE
PBBs : ND(<5 mg/kg) PBDEs: ND(<5 mg/kg)
Cd ND
Pb ND
Hg ND
Cr ND 76.
Br NA
NOT TESTED
REMARK:
DETECTED = BELOW THE LOWER SCREENING LIMIT OF TABLE (B) AND PASS ND = NOT DETECTED NA = NOT APPLICABLE mg/kg = MILLIGRAM PER KILOGRAM = ppm < = LESS THAN > = MORE THAN
# = AS CLAIMED BY THE DECLARATION SUBMITTED FROM THE APPLICANT , THE LEAD
CONTENT OF THE COMPONENT IS COMING FROM THE CONSTITUENT OF HIGH MELTING TEMPERATURE TYPE SOLDERS (i.e. LEAD BASED ALLOYS CONTAINING 85% BY WEIGHT OR MORE LEAD) ONLY. ACCORDING TO EU RoHS DIRECTIVE (2002/95/EC) AND ITS AMENDMENTS, LEAD IN HIGH MELTING TEMPERATURE TYPE SOLDERS OF THIS COMPONENT CAN BE EXEMPTED.
**********************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 30 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
(B) XRF SCREENING LIMITS IN mg/kg FOR REGULATED ELEMENTS IN VARIOUS MATRICES.
ELEMENT POLYMER MATERIALS METALLIC MATERIALS COMPOSITE MATERIALS
Cd P ≤70 < X < 130 ≤ F P ≤ 70 < X < 130 ≤ F P ≤ 70 < X < 150 ≤ F Pb P ≤ 700 < X < 1300≤ F P ≤ 700 < X < 1300 ≤ F P ≤ 500< X < 1500 ≤ F Hg P ≤ 700< X < 1300 ≤ F P ≤ 700 < X < 1300 ≤ F P ≤ 500 < X < 1500 ≤ F Cr P ≤ 700< X P ≤ 700 < X P ≤ 500 < X Br P ≤ 300< X NOT APPLICABLE P ≤ 250 < X
P = PASS X = INCONCLUSIVE RESULT F = FAIL mg/kg = MILLIGRAM PER KILOGRAM = ppm
(C) ESTIMATED DETECTION LIMITS IN mg/kg FOR REGULATED ELEMENTS IN VARIOUS MATRICES.
ELEMENT POLYMER MATERIALS METALLIC MATERIALS COMPOSITE MATERIALS
Cd 50 70 70
Pb 100 200 200
Hg 100 200 200
Cr 100 200 200
Br 200 NOT APPLICABLE 200
(D) CHEMICAL CONFIRMATION TEST METHODS:
TESTING ITEM TESTING METHOD REPORTING LIMIT
POLYBROMINATED BIPHENYLS (PBBs)& POLYBROMINATED DIPHENYL ETHERS (PBDEs)
WITH REFERENCE TO IEC 62321 EDITION 1.0:2008, BY SOLVENT EXTRACTION AND DETERMINED BY GC/MS AND FURTHER HPLC CONFIRMATION WHEN NECESSARY
5 mg/kg
(E) RoHS REQUIREMENT:
RESTRICTED SUBSTANCES LIMITS CADMIUM (Cd) 0.01% (100 ppm) LEAD (Pb) 0.1% (1000 ppm) MERCURY (Hg) 0.1% (1000 ppm) CHROMIUM (VI) (Cr6+) 0.1% (1000 ppm) POLYBROMINATED BIPHENYLS (PBBs) 0.1% (1000 ppm) POLYBROMINATED DIPHENYL ETHERS (PBDEs) 0.1% (1000 ppm)
THE ABOVE LIMITS WERE QUOTED FROM 2002/95/EC AND AMENDMENT 2005/618/EC.
*************************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 31 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS:
(1) BLACK SOFT PLASTIC (PLUG). (2) SILVER COLOR METAL SHEET (PLUG). (3) SILVER COLOR METAL WITH SOLDER (PLUG). (4) BLACK PLASTIC (PLUG). (5) BLACK PLASTIC. (6) GREY-BLACK MAGNET. (7) BLACK PLASTIC WITH WHITE PRINTING (EXTERNAL WIRE COVERING). (8) SILVER COLOR METAL WIRE. (9) WHITE PLASTIC (INTERNAL WIRE COVERING). (10) SILVER COLOR METAL WIRE. (11) BLACK PLASTIC (STOPPER). (12) BLACK PLASTIC WITH WHITE PRINTING (THICK HEATING SHRINKAGE SLEEVING). (13) BLACK PLASTIC WITH WHITE PRINTING (HEATING SHRINKAGE SLEEVING). (14) BLACK PLASTIC WITH WHITE PRINTING (THIN HEATING SHRINKAGE SLEEVING). (15) BLACK PLASTIC (COVER). (16) TRANSPARENT PLASTIC (LIGHT). (17) SILVER COLOR PLASTIC LABEL WITH BLACK COATING. (18) SILVER COLOR METAL SHEET. (19) SILVER COLOR METAL. (20) TRANSPARENT PLASTIC TAPE WITH BLUE ADHESIVE. (21) TRANSPARENT YELLOW GLUE. (22) SILVER COLOR METAL (SCREW). (23) SILVER COLOR METAL (NUT). (24) GREY-BLACK MAGNET.
TRIODE (D8, D9). (a) BLACK PLASTIC BODY.
(25)
(b) SILVER COLOR METAL LEAD. (26) SILVER COLOR METAL SHEET. (27) TRANSPARENT PLASTIC (TUBE).
TRIODE (M1). (a) BLACK PLASTIC BODY.
(28)
(b) SILVER COLOR METAL LEAD. (29) BLUE PLASTIC WITH BROWN PRINTING & SILVER COLOR METAL (CAPACITOR) (C2). (30) BLUE PLASTIC WITH BROWN PRINTING & SILVER COLOR METAL (CAPACITOR) (C3, C4, C13).
CONNECTOR. (a) BLACK PLASTIC. (b) SILVER COLOR METAL SHEET.
(31)
(c) SILVER COLOR METAL PIN. INDUCTOR (L1). (a) COPPER COLOR ENAMELLED WIRE. (b) BEIGE FIBREBOARD. (c) GREEN COATING ON MAGNET.
(32)
(d) GREY-BLACK MAGNET EXCLUDING COATING. IC (BG1). (a) BLACK PLASTIC BODY.
(33)
(b) SILVER COLOR METAL LEAD. ********************************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 32 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS:
CAPACITOR (C1). (a) YELLOW PLASTIC WITH BLACK PRINTING. (b) BRIGHT YELLOW PLASTIC. (c) TRANSPARENT/SILVER COLOR ELECTROLYTIC PAPER.
(34)
(d) SILVER COLOR METAL LEAD. CAPACITOR (C5, C7). (a) YELLOW PLASTIC WITH BLACK PRINTING. (b) BRIGHT YELLOW PLASTIC. (c) TRANSPARENT/SILVER COLOR ELECTROLYTIC PAPER.
(35)
(d) SILVER COLOR METAL LEAD. CAPACITOR (C6, C8). (a) BLACK PLASTIC SHEET WITH WHITE PRINTING. (b) SILVER COLOR METAL SHEET (CASE). (c) BLACK PLASTIC. (d) BEIGE PAPER (ELECTROLYTIC PAPER). (e) SILVER-GREY METAL SHEET (ELECTROLYTIC PAPER). (f) DULL SILVER COLOR METAL SHEET (ELECTROLYTIC PAPER). (g) SILVER COLOR METAL LEAD.
(36)
(h) TRANSPARENT ADHESIVE PLASTIC TAPE. RESISTOR (R1). (a) CERAMIC WITH COATINGS (GOLD COLOR, GREEN, BLACK, BROWN, BEIGE).
(37)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). (38) BLACK PLASTIC WITH WHITE PRINTING & SILVER COLOR CERAMIC & SILVER COLOR METAL
(NTC1). FUSE (CF1). (a) BLACK PLASTIC WITH WHITE PRINTING (HEATING SHRINKAGE SLEEVING). (b) TRANSPARENT GLASS. (c) SILVER COLOR METAL (CAP). (d) SILVER COLOR METAL LEAD. (e) SILVER COLOR METAL WIRE.
(39)
(f) WHITE FIBRE THREAD. DIODE (D1-D3). (a) BLACK PLASTIC BODY.
(40)
(b) SILVER COLOR METAL LEAD. DIODE (D4, D5). (a) BLACK PLASTIC BODY.
(41)
(b) SILVER COLOR METAL LEAD. RESISTOR (R2). (a) CERAMIC WITH COATINGS (GOLD COLOR, YELLOW, BLACK, BROWN, BEIGE).
(42)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). (43) BLUE PLASTIC WITH BROWN PRINTING & SILVER COLOR METAL (CAPACITOR) (C9).
RESISTOR (R4). (a) CERAMIC WITH COATINGS (GOLD COLOR, GREEN, BLACK, BROWN, BEIGE).
(44)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). (45) TRANSPARENT GLASS WITH ORANGE/BLACK MATERIAL & SILVER COLOR METAL (DIODE) (D6, D1,
D2). ********************************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 33 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS:
TRANSFORMER (PT1). (a) TRANSPARENT PLASTIC FILM. (b) TRANSPARENT PLASTIC TAPE WITH BLUE ADHESIVE (THICK). (c) TRANSPARENT PLASTIC TAPE WITH BLUE ADHESIVE (THIN). (d) GREY-BLACK MAGNET. (e) BLACK PLASTIC. (f) COPPER COLOR ENAMELLED WIRE (THICK). (g) TRANSPARENT PLASTIC (THIN TUBE). (h) SILVER COLOR METAL LEAD WITH SOLDER. (i) COPPER COLOR ENAMELLED WIRE. (j) TRANSPARENT PLASTIC. (k) YELLOW PLASTIC (THICK TUBE). (l) SEMI-TRANSPARENT PLASTIC (TUBE). (m) YELLOW PLASTIC (TUBE). (n) COPPER COLOR ENAMELLED WIRE (THIN).
(46)
(o) COPPER COLOR ADHESIVE METAL SHEET. (47) SILVER COLOR METAL WIRE (JUMP WIRE).
CAPACITOR (C10). (a) BLACK PLASTIC SHEET WITH GOLD COLOR PRINTING. (b) SILVER COLOR METAL SHEET (CASE). (c) BLACK PLASTIC. (d) BEIGE PAPER (ELECTROLYTIC PAPER). (e) DULL SILVER COLOR METAL SHEET (ELECTROLYTIC PAPER). (f) SILVER COLOR METAL LEAD.
(48)
(g) SILVER-GREY METAL SHEET (ELECTROLYTIC PAPER). IC. (a) BLACK PLASTIC BODY.
(49)
(b) SILVER COLOR METAL LEAD. RESISTOR (R23). (a) CERAMIC WITH COATINGS (GOLD COLOR, YELLOW, RED, GREY, BEIGE). (b) SILVER COLOR METAL (CAP).
(50)
(c) SILVER COLOR METAL LEAD. RESISTOR (R5, R18). (a) CERAMIC WITH COATINGS (GOLD COLOR, BLACK, BROWN, BEIGE).
(51)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). RESISTOR (R6). (a) BLACK PLASTIC WITH WHITE PRINTING (HEATING SHRINKAGE SLEEVING). (b) CERAMIC WITH COATINGS (GOLD COLOR, SILVER COLOR, RED, BROWN, GREY) (c) SILVER COLOR METAL (CAP).
(52)
(d) SILVER COLOR METAL LEAD. RESISTOR (R7). (a) CERAMIC WITH COATINGS (GOLD COLOR, YELLOW, BLACK, BROWN, BEIGE).
(53)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). (54) BROWN CERAMIC WITH BLACK PRINTING & SILVER COLOR METAL (CAPACITOR).(C12).
IC (IC2). (a) BLACK PLASTIC BODY.
(55)
(b) SILVER COLOR METAL LEAD. (56) GREY METAL WIRE (JUMP WIRE).
********************************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 34 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS:
TRIODE (IC3). (a) BLACK PLASTIC BODY.
(57)
(b) SILVER COLOR METAL LEAD. RESISTOR (R20). (a) CERAMIC WITH COATINGS (GREEN, BLACK, BROWN, BLUE).
(58)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). RESISTOR (R21, R11). (a) CERAMIC WITH COATINGS (GOLD COLOR, RED, BLACK, BROWN, BEIGE).
(59)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). (60) BROWN CERAMIC WITH BLACK PRINTING & SILVER COLOR METAL (CAPACITOR) (C21, C23, C25,
C24, C22, C19). RESISTOR (R22). (a) CERAMIC WITH COATINGS (GREEN, BROWN, BEIGE).
(61)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). RESISTOR (R19). (a) CERAMIC WITH COATINGS (GOLD COLOR, RED, BLACK, BROWN, BEIGE).
(62)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). IC. (a) BLACK PLASTIC BODY.
(63)
(b) SILVER COLOR METAL LEAD. LED. (a) TRANSPARENT GREEN PLASTIC.
(64)
(b) SILVER COLOR METAL LEAD. RESISTOR (R16, R17, R12). (a) CERAMIC WITH COATINGS (GREEN, BROWN, RED, BEIGE).
(65)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). INDUCTOR (L3). (a) COPPER COLOR ENAMELLED WIRE. (b) COATINGS (LIGHT GREEN, BLUE) ON MAGNET.
(66)
(c) GREY-BLACK MAGNET EXCLUDING COATING. RESISTOR (R15). (a) CERAMIC WITH COATINGS (BROWN, RED, BLACK, BLUE).
(67)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). RESISTOR (R14). (a) CERAMIC WITH COATINGS (BROWN, RED, DULL BLUE, WHITE, BLUE).
(68)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). CAPACITOR (C15, C17). (a) BLACK PLASTIC WITH GOLD COLOR PRINTING. (b) SILVER COLOR METAL SHEET. (c) BLACK PLASTIC. (d) BEIGE PAPER (ELECTROLYTIC PAPER). (e) SILVER-GREY METAL SHEET (ELECTROLYTIC PAPER). (f) DULL SILVER COLOR METAL SHEET (ELECTROLYTIC PAPER). (g) SILVER COLOR METAL LEAD.
(69)
(h) TRANSPARENT ADHESIVE PLASTIC TAPE. (70) BROWN CERAMIC WITH BLACK PRINTING & SILVER COLOR METAL (CAPACITOR) (C16).
********************************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 35 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
SCREENED COMPONENTS:
CAPACITOR (C18). (a) BLACK PLASTIC WITH GOLD COLOR PRINTING. (b) SILVER COLOR METAL SHEET. (c) BLACK PLASTIC. (d) BEIGE PAPER (ELECTROLYTIC PAPER). (e) SILVER-GREY METAL SHEET (ELECTROLYTIC PAPER). (f) DULL SILVER COLOR METAL SHEET (ELECTROLYTIC PAPER). (g) SILVER COLOR METAL LEAD.
(71)
(h) TRANSPARENT ADHESIVE PLASTIC TAPE. INDUCTOR (L2). (a) BLACK PLASTIC SHEET WITH WHITE PRINTING (HEATING SHRINKAGE SLEEVING). (b) COPPER COLOR ENAMELLED WIRE.
(72)
(c) GREY-BLACK MAGNET. (73) BLUE PLASTIC WITH BROWN PRINTING & SILVER COLOR METAL (CAPACITOR) (C14).
RESISTOR (R9). (a) CERAMIC WITH COATINGS (GOLD COLOR, BROWN, BLACK, BEIGE).
(74)
(b) SILVER COLOR METAL PARTS (CAP & LEAD). (75) CONFORMAL COATING WITH GREEN SOLDER MASK & COPPER COLOR METAL PAD & FIBREBOARD
(PCB). (76) SOLDER ON PCB.
DISCLAIMERS:
THIS XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT IS FOR REFERENCE PURPOSES ONLY. THE APPLICANT SHALL MAKE ITS/HIS/HER OWN JUDGMENT AS TO WHETHER THE INFORMATION PROVIDED IN THIS XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT IS SUFFICIENT FOR ITS/HIS/HER PURPOSES.
THE RESULTS SHOWN IN THIS XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT WILL DIFFER BASED ON VARIOUS FACTORS, INCLUDING BUT NOT LIMITED TO, THE SAMPLE SIZE, THICKNESS, AREA, SURFACE FLATNESS, EQUIPMENT PARAMETERS AND MATRIX EFFECT (e.g. PLASTIC, RUBBER, METAL, GLASS, CERAMIC ETC.). FURTHER WET CHEMICAL PRE-TREATMENT WITH RELEVANT CHEMICAL EQUIPMENT ANALYSIS IS REQUIRED TO OBTAIN QUANTITATIVE DATA.
DATE SAMPLE RECEIVED : MAR 26, 2010 & APR 03, 2010 TESTING PERIOD : MAR 26, 2010 TO APR 01, 2010 & APR 03, 2010 TO APR 07, 2010
********************************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 36 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
********************************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 37 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
********************************************************************************************
XRF SCREENING AND CHEMICAL CONFIRMATION TEST REPORT NUMBER: SZHH00470818
TESTS CONDUCTED
PAGE 38 OF 38 Intertek Testing Services Shenzhen Ltd.-TFH Division
7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067
Attention is drawn to the terms and conditions printed overleaf.
************************************************************************************
END OF REPORT