x5- MT069.31.200 REV 02 - digicon.com.br · A checklist that works as a guide during inspection...

39
Product manual

Transcript of x5- MT069.31.200 REV 02 - digicon.com.br · A checklist that works as a guide during inspection...

Product manual

Copyright– Digicon S.A.

Electronic Control for Mechanics – 2014

All rights reserved. No part of this publication may be reproduced, transmitted,transcribed, stored in a retrieval system, translated into any language or computerlanguage in any electronic, magnetic, optical, chemical, manual way, or otherwise,without the express written permission from Digicon S.A.

Manual code: 069.31.200English - Revision: 02

This manual was elaborated by: Digicon S.A. Electronic Control for Mechanics

Documentation Sector - EDS

Contents

1. Important instructions ..........................................................................05

2. Orientations ........................................................................................06

3 .........................................................................................06. Introduction

4 ...........................................................07. Features of Catrax Automatic Clip

4.1 Catrax automatic Clip Operation ..........................................................08

5. Installation/Assembly ...........................................................................09

5.1 Unboxing ..........................................................................................09

5.2 Floor drilling and column fixation ..........................................................10

5.3 Assembly the arms ............................................................................11

5.4 Access to Catrax Automatic Clip after assembly ......................................12

5.5 Connetion to power network ................................................................13

6. Installation/Assembly optional items ......................................................14

6.1 Collecting box kit ...............................................................................14

6.1.1 Connecting collector kit to control board .............................................15

6.2 Operational pictogram kit ....................................................................16

6.3 Power suply ......................................................................................17

6.4 Electromechanical counter kit ..............................................................17

6.5 Control board ....................................................................................18

6.5.1 Inputs ...........................................................................................20

6.5.1.1 Return signals ..............................................................................21

6.5.1.2 Electromagnets ............................................................................21

6.5.1.3 Sound alarm ................................................................................21

6.5.1.4 Connection scheme ......................................................................22

6.5.1.5 Pictogram ....................................................................................23

6.5.2 Outputs .........................................................................................23

6.5.3 Configuration of control board ...........................................................23

6.5.4 Turnstile Interface ...........................................................................25

7. Maintenance .......................................................................................31

7.1 Preventive and corrective routine maintenance ......................................31

7.2 Solving problems ...............................................................................32

8. Technical characteristics .......................................................................33

9. Warranty and technical assistance .........................................................35

05

1. mportant nstructionsI i

You can see, below, the symbols that will appear in this manual,signaling important moments. It is essential to pay attention to them.

TIP: Indicates something Digicon considers important.

CAUTION: Indicates a moment of extreme caution whenhandling the equipment/product

ATTENTION: Indicates a moment when your observationskills should be extremely productive.

INFORMATION: Presents interesting facts about thepurchased product.

QR CODE: Presents additional information or linkswith more details about the presented text.

2. Orientations� Read the information and instructions of this manual carefully, before using the

product. This ensures the correct use of the equipment and maximum use of itstechnical features as well as a prolonged service life.

� This product does not present sealing against the rain, that is, it is designed to beused indoors.

� Keep this manual for future consultations.� Digicon reserves its right to alter its products at any moment to adapt them to more

recent technical advancements.� Digicon maintains its right to alter the information contained in this manual without

previous notice.� Digicon does not provide any contractual warranty concerning the information in this

manual, and cannot be held responsible for errors it may contain and problems dueto its use.

� The information contained in this manual is exclusive property of Digicon and isprotected by copyright laws.

� This manual cannot be reproduced, photocopied or translated, in its entirety or inpart, into any kind of medium, without Digicon's written consent.

3. IntroductionFollowing a new technological concept focused on solidity and reliability and countingwith innovative design elements, with color variety and widely curved lines, Digicon haslaunched the line .CATRAX Automatic Clip

CATRAX Automatic Clip serves most technologies of access control currentlyavailable, becoming the best option in the market for access control.This manual presents a detailed description of the components and working ofCATRAX Automatic Clip. To see our complete catalogue, visit www.digicon.com.br.

06

4. Features of Catrax Automatic Clip

07

CATRAX Automatic Clip, an access controller in the model mini turnstile (columntype), destined to individuals with special needs, presents one arm with brushedstainless steel (AISI 304) finishing and two-directional mechanism, with horizontalmovement. The column can present external finishing in brushed stainless steel (AISI304) or 1020 carbon steel with electrostatic painting in black epoxy powder. It hasreinforced structure, fully rounded corners, and non-exposed screws, offering spaceand comfort for any access control solution. It also has room for a collecting box(optional item). Aiming at facilitating assembly and maintenance, the columnCATRAX presents a U-shaped internal support (mounting rack) withAutomatic Clip

standard holes for the fixation of additional electronic boards. Moreover, the clients,according to their needs, can add additional holes. Access to the mounting rack isdone through a key with secret, and the removal and insertion are done through thefrontal door.

A plastic cover and a stainless steel sheet compose the upper panel. The cover, madeof injected plastic, can be purchased in stainless steel or black (other colors availableon demand). Optionally, the cover can present a slot for the reading of magneticcards/badges and barcodes. The upper cover in stainless steel allows easyconfiguration and low-cost customization of the product. The sheet can also presentslots for optional items, such as pictogram, collecting box input, display kit, or acombination of these items.

TIP: CATRAX AutomaticTo see details about the dimensions ofClip's items, see item 8. Technical characteristics.

4.1 Catrax Automatic Clip operation

CATRAX Automatic Clip has a two-dimensional rotation system with two 24 V cdelectromagnets for activating the locks.It includes a microprocessor control board where a signal enabling passage is sentthrough one of the inputs, depending on the passage direction. If this signal isrecognized, the equipment will allow the movement of the arm of CATRAX Automatic

Clip. After half of the turning is complete (45 degrees), a 400 milliseconds returningsignal will be sent, informing the passage direction. After the signal, the arm cannot bereturned to the previous position.Depending on the model and configuration, if the passage isCATRAX Automatic Clipforced without the enabling signal, an electromagnet will be activated to preventpassage. In addition, the equipment can emit a signal for a sound alarm and/or theexhibition of a red sign on the upper panel display (models with pictogram). In thiscase, a return signal will be sent, indicating that the turnstile was forced, informing thedirection of turn.

The image below shows how mechanism works:CATRAX Automatic Clip's

08

5. Installation/Assembly

5.1 Unboxing

As the items inside the package can vary (depending on the client's requests), it isimportant to perform a cautious visual inspection before installing and assembling theturnstile. A checklist that works as a guide during inspection accompanies all Digiconpackages.

See below the parts that can compose CATRAX Automatic Clip.

09

Arm

Front cover

Rear cover

Lock for accessing the column's interior

Pictogram(optional)

Rotary axis

Lock for accessingthe mechanism

Cables passage

Column

5.2 Floor drilling and column fixation

Before installing , check:CATRAX Automatic Clip

1. The place chosen for the installation.2. If there is a power source or electric socket nearby (ducts for connection).3. If the place chosen is adequate for the installation of the access controller (indoors).4. If there will be enough space (minimum 5 cm) between the rear of the CATRAX CAutomatic Clip lip column and the wall. This space is important in order to provideaccess to the upper panel and plug's locks for the cables passage.5. If there will be enough space for the arms after CATRAX Automatic Clip is assembled.6. If the floor is in conditions to receive anchor bolts (minimum of 4 cm of FCK15 M.P.A.concrete or equivalent).

ATTENTION: To see details on the dimensions of CATRAX Automatic Clip,

see item 8 (technical characteristics).

10

To fix the column to the floor, observe the following steps and the indicated images:

1. rill the floor with 3/8” drills (then use a 12mm or the ½” drill). Make four externalDholes, according to the measures indicated in the image below:2. Clean the holes, removing any debris from drilling.3. Place the external part of the bolts in the holes. Leave about 25mm of the bolt out ofthe hole.4. Position the column and fasten it to the floor with the four screws that accompanythe bolts. Use a flex-head socket wrench with ¾'' or an articulated socket wrench.

12,5 (4x)

210

170

60

45

Saída de cabos92

,53

2

20

Fixing drilling

3090

TIP: We recommend the bolts by the brand Tecnart, modelAF38110, 3/8x4''.

5.3 Assembling the arms

INFORMATION: The cover to access the screws is open/closed bypressure (fitting). To assemble the CATRAX Automatic Clip's arms, usean Allen n.5 wrench.

11

After drilling the floor and assembling the column, it is possible to assemble the armsand plastic covers.

The sequence below shows the instructions to help assembling CATRAX Clip's arms.Digicon suggests that two people assemble the arms.

1. With already unboxed and installed, set the arms close toCATRAX Automatic Clipthe tube's frontal holes (central axis). First, fit the arm's lower rod and press the upperrod so it reaches the respective hole.

2. Once the arm has both rods duly fitted, turn the arm to one side up to about 180degrees or until it reaches the end of its track. You will notice there are two holes on theback of the tube.3. Use an Allen n.5 wrench to fasten the arms to the holes using the bolts and washersprovided with the product.

1º) 2º)3º) 4º)

5.4 Accessing Catrax Automatic Clip after assembly

After is installed and assembled, access to the interior of theCATRAX Automatic Clip

equipment can be done with the key that accompanies the equipment, in two ways:

- Rear cover and frontal cover: open the lock with the key at the rear of CATRAX

Automatic Clip CATRAX Automatic Clip.; unscrew the screws at the front of

- Column door: Open the lock with the key and pull the door.

As shown below:

12

5.5 Connection to power network

The Turnstile is powered by a 24 V c supply (located inside the turnstile). The powerdsupply can be of 100 to 240 V . Digicon recommends the regulation NBR 5410 asacreference to the equipment's electrical connections. In one of its columns, the turnstilehas circuit breakers in its columns where the power cables (electrical supply) and theground wire must be connected.

CAUTION: Electric connections must be performed by qualifiedprofessionals.

13

Aterramento

Rede elétrica

TIP: We recommend that you use a good quality AC cable and ground

wire and with compatible dimensions to the distance until the

switchboard. The data cable must be type CAT5E. Recommended

manufactures: FURUKAWA and AMP.

Entrada paracabo de dados

6. Installing/assembling optional items

CATRAX Automatic Clip is compatible with most access control technologies in themarket today; however, Digicon offers a range of optional items that allow enhancingand matching the equipment's performance to the client's needs. See the descriptionof each of these items:

The collecting box kit has a device for collecting, retaining, and gathering cards orbadges. It is ideal for places with eventual visitors or users. The kit is composed of asocket, a retention device activated by a solenoid, and a storage box. The image belowshows the items that accompany the collecting box kit and may work as a guide for itsassembling:

14

6.1 Collecting box kit

6.1.1 Connecting collector kit to control board

12 11 10 9 8 7 6 5 4 3 2 1 12 11 10 9 8 7 6 5 4 3 2 1

BOX SENSOR ELECTROMAGNETS TURNSTILE SENSORS

DIGICON CONTROL BOARD

INPUTS CN8 OUTPUTS CN9

- S

OL

EN

OID

+ S

OL

EN

OID

SOLENOID

Seu leitor de cartão(não faz parte do kit)

Para placacontrole de acesso

Sensor utilizado pararecolher o cartão após1,5 segundos

TIP: To obtain information about the collecting box kit's configuration,consult item 6.5 Control board.

15

Sensor used for collectingthe card after 1.5 seconds

To the access control board

Yo u r c a r d r e a d e r(not included in the kit)

INFORMATION:- The box for cards is part of the kit and is positioned under thecollecting kit.- The badge reader is not part of the kit.

16

6.2 Operational pictogram kit

The operational pictogram kit visually signals if the passage is cleared or not (throughgreen and red pictograms) on CATRAX Automatic Clip's front.

Passagecleared(green)

Passageblocked(red)

TIP: To obtain information on the configuration of the pictogram, see item

6.5 Control board.

17

6.3 Power supply

Among the main advantages of this optional item, is its adaptation capability to thevoltage variations often found in installation sites – the input voltage can vary between100 and 240 V .acThe supply's specific technical features, protections and dimensions were carefullytested and approved in hostile temperature and environmental conditions, whichensures the adequate power supply to the equipment's performance. Besides theinput and output voltages indicated in the image below, the supply has a short-circuitand overheating protection.

PHASE

NEUTRAL

GROUND WIRE

GND24V / 3Adc

INPUT:

100 a 240 Vac

OUTPUT

6.4 Electromechanical counter kit

The counter kit presents six digits, from no return to zero, and is located on the bowl'supper part of the turnstile.The counter presents pulse input, making it possible to detect turnstile rotations in agiven direction. The device is also capable of counting single pulses (as other countersavailable on the market).

Technical characteristics:Power supply: 24 V cdNumber of digits: 06 (no return to zero)Digits size: 5 x 2 mm (height x width)

6.5 Control Board

CATRAX Automatic Clip's control board was designed to meet most technologies ofaccess control terminals in the market. The controller have mechanical features andlayout perfectly suited for the CATRAX Automatic Clip's needs and it is one of the bestoptions for the equipment's operation.The following images show the control board with its straps, connectors, and dipswitch,as well as the location of the power supply and the control board in CATRAX AutomaticClip.

CONNECTORCN8

CONNECTORCN9

Ds1

Ds2

The table below describes the functions of the control board's connectors:

18

19

Signal Nome/DescriptionCN1 BOX SENSOR

1 LED anode2 Box Signal3 GND4 GND

CN2 JTAG – Inner use

CN3 SERIAL RS - 2322 TX3 RX5 GND

CN4 ENGINE1 DATE +2 DATE -3 GND_4854 (+) 24V_EXT5 GND

CN5 POWER – POWER SUPPLY1 (+) 24V cd2 GND3 (+) 24V cd

CN6 TURNSTILE SENSORS1 sensor 1 signal2 LED 1 anode3 sensor 2 signal4 GND5 LED 2 anode

CN7 AUDIO1 SIGNAL2 GND

CN8 ENTRADAS1 (+) vext1 (enables turn through voltage)2 HAB1 (enables turn through dry contact – from right to left)3 GND4 Vext2 (enables turn through voltage)5 HAB2 (enables turn through dry contact – from left to right)6 GND7 +24V c (available to auxiliary – maximum 500 mA)d8 Vext3 (enables turn through voltage)9 BQC (activates anti-panic system)10 GND11 Output for yellow pictogram12 NC13 NO or NC contact (bob return)14 C Contact (bob return)15 NO or NC contact (BOC return)16 contact C (BOC return)

caVca

20

The following sections concern important aspects of CATRAX Automatic Clip controlboard configuration and connections of CATRAX Automatic Clip.

6.5.1 Inputs

The input signals or passage clearance (HAB1 and HAB2) or anti-panic (BQC) can beoriginated by a relay contact, pushbutton contact, tension from 5 to 24 Vca/cc, from110 to 220 Vca/cc. To enable passage through relay contact or pushbutton, make theconnection as shown below:

INFORMATION: - The engine (CN4) and electromagnets (CN18) cables

are provided alongside CATRAX Automatic Clip.

CN9 OUTPUTS1 NO or NC Contact (HAB1 return)2 Contact C (HAB1 return)3 NO or NC Contact (HAB2 return)4 Contact C (HAB2 return)5 Output for indicative X (open collector NPN – maximum 500 mA)orange wire6 Output for arrow > (open collector NPN – maximum 500 mA) bluewire7 Output for arrow < (open collector NPN – maximum 500 mA) greenwire8 +24V c (indicative arrows' power) red wired9 GND (indicative arrows' power) black wire10 + solenoid of badge collector box11 - solenoid of badge collector box12 Sound signal (open collector – NPN)CN10 SOL BQC1 (+) 24V cd2 SIGNALCN14 BQC SENSOR1 (+) 2 4V cd2 SIGNALCN18 ELECTROMAGNETS1 (+) electromagnet 12 (-) electromagnet 13 (+) electromagnet 24 (-) electromagnet 2

Enabling passage through tension pulse is shown in the image below. It is necessary toobserve the polarity of the C voltages and to use an external resistor for high voltagesD(110V and 220V ).ac

6.5.1.1 Return signals

The control board has 4 return signals, two to indicate the moment, one to bob theturnstile, and one to indicate the anti-panic system's status. All signals are originatedvia relay – normally open contact (NO) or normally closed contact (NC). Connect theoutputs according to the image below:

6.5.1.2 Electromagnets

Electromagnets are activated for blocking the turnstile. Opposite to the traditionalsolenoids, electromagnets do not cause abrasion between the coil and the lockingdevice, avoiding malfunctions. Moreover, the activation is done through a transistor,and not a relay, avoiding the electromagnet to be blown due to the “contact wielding”(there is no mechanical wear).

ATTENTION:The relay contacts have maximum capacity of 1A 125 V .ac

21

Vac ou Vdc Vac ou Vdc

Vca

6.5.1.3 Sound alarm

The sound alarm output is activated by a NPN transistor (maximum 500 mA) everytime that CATRAX Automatic Clip:-receives a clearance signal (two short rings)-is not cleared and is forced during 1 second (1-second rings)-is stuck mid-turn for over 2 seconds (1-second rings)

Connect the outputs according to the following image:

6.5.1.4 Connection scheme

22

Vac

Sound alarm

Maximum current: 500mA

INPUTS

INPUTS

OUTPUTS

RALAY

ACCESS CONTROL BOARDOUTPUTS

DIGICON CONTROL BOARD

RETURNSIGNALS

6.5.1.5 Pictogram

The pictogram's outputs are activated by NPN transistors (maximum 500 mA) at themoment of activation, the GND is sent through a corresponding output.

6.5.2 Outputs

CATRAX Automatic Clip's board has outputs for return signals, electromagnets,pictogram, collecting box, and sound alarm.

6.5.3 Configuration of Control Board

The switch (or dipswitch) DS1 allows programming the following actions:-passage direction-Maximum time for passage-NO inputs (relay or pushbutton contact normally open and without input voltage),enabling passage in face of these signals; or NC inputs (relay or pushbutton contactusually closed and with input voltage), enabling passage in the absence of thesesignals.-enabling of a signal for a sound alarm if the access control remains at mid passage formore than 2 seconds.

To program DS1, put each pin in the desired position, according to the table below:

23

12 11 10 9 8 7 6 5 4 3 2 1 12 11 10 9 8 7 6 5 4 3 2 1

BOX SENSOR ELECTROMAGNETS TURNSTILE SENSORS

DIGICON CONTROL BOARD

INPUTS CN8 OUTPUTS CN9

GN

D

+ 2

4V

/ 1

2V

OU

TP

UT

NP

N 5

00m

A

OU

TP

UT

NP

N 5

00m

AO

UT

PU

TN

PN

500m

A

PT

VM

VD

AZ

LR

PT

VM

VD

AZ

LR

RED RED/ /GREEN GREEN

XXXXXX

BOARD’S VERSIONNUMBER

CHAVE 1 2 3 4 5 6 7 8

Enables sound signal ON

Disables sound signal OFF

NO inputs ON

NC inputs OFF

Habilitation per border OFF

Habilitation per level ON

Blocked in both directions ON ON

Blocked form right to left OFF ON

Blocked from left to right ON OFF

Cleared in both directions OFF OFF

Enables sound signal in mid-turn ON

Disables sound signal in mid-turn OFF

Wait until first turn (no turning timeout) ON ON

05 seconds turnstile 120° 05 seconds turnstile CLIP OFF ON

10 seconds turnstile 120° 15 seconds turnstile CLIP ON OFF

15 seconds turnstile 120° 20 seconds turnstile CLIP OFF OFF

DIP SWITCH DS1

The switch (or dipswitch) DS2 allows programming the following actions:- invitation- turning speed- passage counting

To program DS2, put each pin in the desired position, according to the table below:

CHAVE 1 2 3 4 5 6 7 8

Enables invitation ON

Disables invitation OFF

Nominal speed ON

Half nominal speed OFF

Enables clockwise counting ON

Disables clockwise counting OFF

Enables counter clockwise counting ON

Disables counter clockwise counting OFF

Enables bob return and disables box ON

Enables box return and disables bob OFF

Retention time of the card in the box for reading 1s ON

Retention time of the card in the box for reading 2s OFF

Disk emulation for MCA ON

Disables disk emulation (Standard Control Board Operation) OFF

Firmware Type Turnstile 120° ON

Firmware Type Turnstile CLIP OFF

DIP SWITCH DS2

24

6.5.4 Turnstile Interface

Enabling through Dry contact with 2 relays:

Enabling both ways (Clockwise and Counter Clockwise) with 1 single relay:

7654321

U

U

U

U

U

U

U

U

U

U

Dry contact

EnablingClockwise

Enabling antiClockwise

7654321

UUUUU

Relay

Integrator’s controller board

25

Dry contact (simultaneos)

654321

CCW

CW

Vdc Vdc

Vdc = 5~24V

Integrator’s controller board

Anti panic/drop arm mechanism input:

Enabling through solid state :

10987

UUUUU

Integrator’s controller

26

Dry contact

INFORMATION:CCW: Counter Clockwise

CW: Clockwise

Enabling through solid state(negative):

Activating through solid state(anti panic/Drop arm mechanism):

1098

Vdc

Vdc = 5~24V

Anti panic

27

54321

Vdc

Vdc = 5~24V

CCW

CW

Integrator’s controller

Integrator’s controller

Activating through solid state (Drop arm/Negative).

Passage confirmation

Vcc - Rel logic lever, SH in ’’disk emulation’’ DIP Ds2 n°7 in mode ON.

Vdc

4321

Digital positive input

UUUUU

NA NFRl2

3

4

NO NC

1

2

Rl1

UUUUU CW

CCW

28

98

Vdc = 5~24V

Vdc

Integrator’s controller

Integrator’s controller

Passage confirmation through disk emulation

Passage confirmation through clockwise pulse

Passage confirmation through ’’disk emulation’’ can be set through dip switch Ds2,nº7 in case it’s on it’ll emulate disk. On the other hand it’s off, it’ll general pulse.

Passage confirmation(negative)

29

1

1

1

1

Rl1

Rl1

Rl2

Rl2

4321

Digital negative input

Integrator’s controller

Electromechanical counter connections

87 Counter

Vdcprotection diode

In case you use inductivecounter it will be necessary

a protection diode

Inductive counter

Depends on thecouter tension

30

7. Maintenance

7.1Preventive and corrective routine maintenance:

Electromagnets – Periodicity: ever 7000,000 cyclesThis routine maintenance requires the use of a multimeter. To check for the need ofcorrective actions, disconnect the CN3 from the access control board and check theelectromagnets' resistance. The value must be between 11 and 12.5 ohms betweenpins 1 and 2 and 3 and 4 of the electromagnet's connector. After measuring,connect CN3 to the board again.

Corrective actions:1. if you spot an incorrect resistance, a short-circuit or open electromagnet, replace it.2. if the electromagnet is not working, check the board or the voltage3. if the electromagnet is moving, fasten the base screws.

Electromagnets adjustments (if necessary)1. Force the lock against the sprocket and the equipment's arm until the lock iscompletely inside the first teeth (until the arm is locked)2. then, release the fixing screws and press the electromagnet against the lock's frame,so that its area is completely against the electromagnet3. refasten the screws

Set of locks – Periodicity: every 700,000 cycles

To check for the need of corrective actions, you must:

-check the lock's correct position-check the wear of the lock's fitting in the sprocket

Corrective actions

1. if the lock's position is incorrect, check the retaining ring and the spring that tightensthe set2. if the lock's fitting to the sprocket is incorrect, replace the lock or the sprocket3. if lock's end is worn, replace the lock

Sprocket set – Periodicity: every 700,000 cycles

To check for the need of corrective actions, you must:

-check the wear of the sprocket's teeth-check the gap between the central axis, the sprocket, and the keyway.

Corrective actions

1. if you observe wear on the parts' teeth, replace the parts.2. if you see a gap between the sprocket and the axis/keyway set, replace the sprocketor the keyway (to replace the sprocket, use a pulley puller).

31

ATTENTION: Preventive and corrective maintenance must be performedby a professional trained/qualified by Digicon S.A.

32

7.2 Solving problems

Defect Possible causes Action· It will not turn

on.· The power supply’s input

cable is not connectedproperly

· The circuit breaker is off.

· Check the cablesand the fuse.

· It does notactivate the

electromagnet(turnstile cannot

be locked).

· The cable is broken or thedistance between theelectromagnet and the

locking device ismaladjusted.

· Adjust theelectromagnet or

forward theequipment to the

TechnicalAssistance.

· The arm does notremain in the

correct position.

· There is wear, dirt, abroken spring or lack oflubrication in the sphere

base.

· Request areplacement forthe faulty part or

forward theequipment to the

TechnicalAssistance.

· It does not lockin the first

tooth.

· The distance between theelectromagnet and the

locking device ismaladjusted.

· Adjust theelectromagnet or

forward theequipment to the

TechnicalAssistance.

33

8. Technical characteristics

1061

1010 157

1860

300,4

210

R930

Dimensions:Equipmentassembled

INFORMATION: he arm/clip's size can be altered according to the client'sT

needs.

Other information

Grossweight:

Approx. 45 kg (package included)

Electromagnets’power

12Vdc / 2A

Power supply Input: 100Vac to 240Vac 60HZOutput: 24,0Vcc +/- 5%4,5A

Operationaltemperature

from0ºC to 50ºC

Power Consumption during rotation is 36 W

INFORMATION: The measures in the images are given in millimeters

34

243

300

510

1042

digicon

Catrax

www.catrax.com.br

35

9. Warranty and technical assistance

Digicon is responsible for the project, skilled labor, and quality of the materials used in themanufacturing of our products, ensuring that the equipment and all parts are free ofmanufacturing defects or problems. Digicon commits itself to replace or repair, as we choose,any part or equipment presenting manufacturing defects without any costs to the buyer, in ourfactory in Gravataí or our branch office in São Paulo, in the conditions set below:

1. The buyer is responsible for the costs of shipping (return service) of the product to the factoryin Gravataí or the branch office in São Paulo.

2. The warranty period is counted from the date of emission of the bill of sale and encompasses:a) 12 (twelve) months for equipment, accessories, parts, and pieces, including the legalwarranty period of 90 (ninety) days.

Legal warranty

The customer has the period of 90 (ninety) days, from the date of emission of the bill of sale, tocomplain about apparent defects (easily observable in the product), such as the items thatconstitute the product's exterior and any other area accessible to the user, just like appearanceparts and general accessories.

b) 90 (ninety) days for repairs or technical assistance

3. Warranty shall be granted to the buyer only in the face of the bill of sale (original or copy).

4. Warranty does not apply in the following cases or conditions:

a) defects and damages caused by accidents, negligence, or reasons of force majeure

b) defects and damages caused by inappropriate storage or lack of prolonged use

c) defects and damages caused by improper use of the equipment

d) defects and damages caused by improper operation or installation of the equipment

e) vandalism

f) natural impacts (lightning, flooding, etc.)

g)defects and damages caused by abnormal temperature conditions, voltage/frequency, orhumidity out of the levels specified in the installation and operation manual, once proven

h) reconditioning, chrome plating, nickel plating, and painting

5. Warranty shall be automatically canceled for equipment that:

a) suffers modifications, adaptations, or any alterations performed by the client or by thirdparties without Digicon's written consent

b) goes through maintenance or repairs by people not authorized by Digicon

c) suffers alteration of serial number or violation of the identification label

d) is not paid for in the conditions, amounts, and deadlines described in the bill of sale

6. Digicon is not responsible for eventual losses suffered by the down time of the equipment

7. The repair of a warranted product will be performed inside the Digicon facilities.

Head office/RS

Factory, Technical Assistance, and Sales

Development, Technical Assistance, and Sales

Rua Nissin Castiel, 640 - Distrito Industrial.Gravataí/RS CEP 94045-420

Vendas: (0xx51) 3489.8700 / 3489.8745Assistência técnica: (0xx51) 3489.8903

Fax: (0xx51) 3489.1026E-mail: [email protected]

Branch office/ SP

Rua São Paulo, 82 - Alphaville.Barueri/SP CEP 06465-130Fone: (0xx11) 3738.3500Fax: (0xx11) 4191.2585

E-mail: [email protected]

Home page: www.digicon.com.br