X-ray production
Unit 20 strand 1 (P2)Describe the production of x-rays and ultrasound
![Page 2: X ray production 2](https://reader036.fdocuments.net/reader036/viewer/2022062303/558ba9aed8b42a29568b45b5/html5/thumbnails/2.jpg)
X-rays were first discovered in 1895 by the German physicist William Roentgen, when using a Crookes tube
He called them ‘x’ rays, ‘x’ for ‘unknown’.
![Page 3: X ray production 2](https://reader036.fdocuments.net/reader036/viewer/2022062303/558ba9aed8b42a29568b45b5/html5/thumbnails/3.jpg)
The first x-ray photograph: Roentgen’s wife Bertha’s hand
![Page 4: X ray production 2](https://reader036.fdocuments.net/reader036/viewer/2022062303/558ba9aed8b42a29568b45b5/html5/thumbnails/4.jpg)
![Page 5: X ray production 2](https://reader036.fdocuments.net/reader036/viewer/2022062303/558ba9aed8b42a29568b45b5/html5/thumbnails/5.jpg)
X-rays are electromagnetic radiation of high frequencies (1017-1020 Hz). They penetrate soft tissue but are blocked by bone etc.
![Page 6: X ray production 2](https://reader036.fdocuments.net/reader036/viewer/2022062303/558ba9aed8b42a29568b45b5/html5/thumbnails/6.jpg)
X-rays are produced when high-speed electrons hit a metal target. In medical x-rays this is usually tungsten.
x-rays
Electrons
Tungsten target(anode)
![Page 7: X ray production 2](https://reader036.fdocuments.net/reader036/viewer/2022062303/558ba9aed8b42a29568b45b5/html5/thumbnails/7.jpg)
Electrons are produced by thermionic emission.
They are accelerated across the vacuum tube towards the positive (anode) target.
The electrons strike the target and lose about 99% of their energy in low-energy collisions with the target atoms – this heats up the target. The remainder of the energy reappears as x-ray radiation.
Overheating is prevented by using a rotating anode and circulating oil. Copper is used for the anode mountings.
![Page 8: X ray production 2](https://reader036.fdocuments.net/reader036/viewer/2022062303/558ba9aed8b42a29568b45b5/html5/thumbnails/8.jpg)
![Page 9: X ray production 2](https://reader036.fdocuments.net/reader036/viewer/2022062303/558ba9aed8b42a29568b45b5/html5/thumbnails/9.jpg)
Overheating is prevented by using a rotating anode and circulating oil. Copper is used for the anode mountings.
![Page 10: X ray production 2](https://reader036.fdocuments.net/reader036/viewer/2022062303/558ba9aed8b42a29568b45b5/html5/thumbnails/10.jpg)
The energy exchange in x-ray production