X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model...
Transcript of X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model...
X-ray Inspection System
KD74
KD74-h
KD74-f
DualX
For Specific Applications
May 2017
X-ray Inspection System
Product Catalog
L i n e u p
StandardKD74 series
Products Dry products Wet products
Protection class IP40 IP66
X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)
Product range ●Size variations
Highly versatile system with a proven track record suits a wide range of packaged products.
Simultaneous inspection including shape analysis, missing item and package integrity inspection
are available.
EntryKD74-f series
Products Dry products Wet products
Protection class IP40 IP66
X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)
Product range ●Size variations
With low X-ray output and simple construction, this series are suitable for dry products.
DualX
Products Dry products Wet products
Protection class IP40 IP66
X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)
Product range ● High power ● Low power
Analyzing two different x-ray energy signals, it clearly distinguishes contaminants from products.
Performs accurate inspection of low density bones in meat and overlapping products.
For Specific Applications
●Large bags and cartons ●Tall products ●Pharmaceutical
●Sanitary design ●Pipe type
X-ray systems in a variety of configurations offered to fit specific inspection requirements.
High DefinitionKD74-h series
Products Dry products Wet products
Protection class IP40 IP66
X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)
Product range ●For metal particles ●For low density contaminants ●Size variations
High accuracy detection technology detects a 0.2 diameter metal sphere. Suitable for soft
contaminants that are of low-density, such as bone and plastics, as well as for minute metal
particles.
2
X-ray Inspection System
Product Catalog
L i n e u p
StandardKD74 series
Products Dry products Wet products
Protection class IP40 IP66
X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)
Product range ●Size variations
Highly versatile system with a proven track record suits a wide range of packaged products.
Simultaneous inspection including shape analysis, missing item and package integrity inspection
are available.
EntryKD74-f series
Products Dry products Wet products
Protection class IP40 IP66
X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)
Product range ●Size variations
With low X-ray output and simple construction, this series are suitable for dry products.
DualX
Products Dry products Wet products
Protection class IP40 IP66
X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)
Product range ● High power ● Low power
Analyzing two different x-ray energy signals, it clearly distinguishes contaminants from products.
Performs accurate inspection of low density bones in meat and overlapping products.
For Specific Applications
●Large bags and cartons ●Tall products ●Pharmaceutical
●Sanitary design ●Pipe type
X-ray systems in a variety of configurations offered to fit specific inspection requirements.
High DefinitionKD74-h series
Products Dry products Wet products
Protection class IP40 IP66
X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)
Product range ●For metal particles ●For low density contaminants ●Size variations
High accuracy detection technology detects a 0.2 diameter metal sphere. Suitable for soft
contaminants that are of low-density, such as bone and plastics, as well as for minute metal
particles.
Note: Any one of the pass heights can be selected.
Model Detection area (Units:mm) Page
KD7405AWH/ADWH /BWH/BDWH W2 (160)
W1 (240)
H (
120)
Effective detection width = 240 –
80×Hp120
Effective detection height=120×(240–Wp)
80
4
KD7405CWT/DWTKD7405DWH 8, 9
KD7405KP/KDP 10
KD7405ABWH
W2 (200)
W1 (240)
H(50
)
Effective detection width = 240 –
40×Hp50
Effective detection height=50×(240–Wp)
40
6
KD7405ACWH 7
KD7405KCP 10
KD7416AWH/ADWH /BWH/BDWH W2 (280)
W1 (390)
H (
150)
Effective detection width= 390 –
110×Hp150
Effective detection height=150×(390–Wp)
110
5
KD7416DWH 9
KD7416AWZE/ADWZEKD7416DWZ 11, 12
KD7416ABWH
W2 (355)
W1 (390)
H (50) Effective detection width= 390 –
35×Hp50
Effective detection height=50×(390–Wp)
35
6
KD7416ACWH 7
KD7416ACWZE 11
KD7417BWH W2 (230)
W1 (390)H
(22
0)
Effective detection width= 390 –
160×Hp220
Effective detection height=220×(390–Wp)
160
5
KD7417DWH9
KD7447DWKD7447DWEKD7447FWE
W2 (410)
W1 (590)
H (
250)
Effective detection width= 590 –
180×Hp250
Effective detection height=250×(590–Wp)
180
13●Pass height: 350 mm (Optional)
H (
350)
W2 (335)
W1 (590)
Effective detection width= 590 –255×Hp
350
Effective detection height=350×(590–Wp)
255
KD7416AM W2 (255)
W1 (365)
H (
150)
Effective detection width= 365 –
110×Hp150
Effective detection height=150×(365–Wp)
110
14
KD7416ACMW2 (330)
W1 (365)
H (50) Effective detection width= 365 –
35×Hp50
Effective detection height=50×(365–Wp)
35
14
KD7478AWHKD7478BWH
W (150)
H1
(307
)
H2
(237
) Effective detection width=150×(307–Hp)
70
Effective detection height= 307–70×Wp
150
15
KD7490LYN
W(100)H(30)
Effective detection width =100
Effective detection height= 3017
Model Selection List
Products
3
● When Hp ≦ 237: Effective detection width = 150
● When 237 < Hp ≦ 307:
X-ray Inspection System
4
■ Specifications
Model KD7405AWH KD7405ADWH KD7405BWH KD7405BDWHDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 W Tube voltage 25 to 80 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 240 mm, maximum height 120 mmBelt width 270 mmPreset memory Maximum 100
Belt speed 4
Maximum product weight 5
5 to 60 m/min, maximum 5 kg61 to 90 m/min, maximum 2 kg5 to 40 m/min, maximum 10 kg (optional)
Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 210 kg 215 kg 220 kg 225 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).
External Dimensions
240
590
to 6
90
196
(80º)
73046
526
513
60 to
146
0
270
Bel
t wid
th
33.5 dia.Roller
60 dia.
450Leg spacing
605Leg spacing
240Effective detection width
700
to 8
00Li
ne h
eigh
ts
120
Pas
s he
ight
800/※1000
500
120
240
160
Detection area
Units:mm
KD7405AWH KD7405ADWH *KD7405BWH KD7405BDWH *
StandardKD74 series
KD7405AWH/ADWH/BWH/BDWH Maximum width Maximum height
Detection area: 240 mm × 120 mm
KD7405AWH
Enter the curtain in stable position
Become unstable at the joint
Become unstable by the curtain
Pass over the joint in stable position
KD7405ADWH / KD7405BDWH
The conveyor is lengthened from 800 to 1000 for smooth product transfer.
For Packaged Products
KD
74 seriesK
D74
-h series
KD
74-f series
For Specific ApplicationsD
ualX
X-ray Inspection System
5
■ Specifications
Model KD7416AWH KD7416ADWH KD7416BWH KD7416BDWH KD7417BWHDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm long
X-ray outputTube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 W
Tube voltage 25 to 80 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 W
Safety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)
Detection area 2, 3 Maximum width 390 mm, maximum height 150 mmMaximum width 390 mm, maximum height 220 mm
Belt width 420 mmPreset memory Maximum 100
Belt speed 4
Maximum product weight 55 to 60 m/min, maximum 5 kg 5 to 40 m/min, maximum 10 kg5 to 40 m/min, maximum 10 kg (optional) ー
Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 255 kg 260 kg 265 kg 270 kg 265 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).
External Dimensions
150
390
280
Detection area
880
540
340
420
Bel
t wid
th15
30 to
163
0
33.5 dia.Roller
60 dia.
450Leg spacing
700
to 8
00Li
ne h
eigh
ts
800/※1000
500
(280)271
(80º)
755Leg spacing
390Effective detection width
150
Pas
s he
ight
600
to 7
00
Units:mm
KD7416AWH KD7416ADWH *KD7416BWH KD7416BDWH *
220
390
230
Detection area
880
540
340
420
Bel
t wid
th
1530
to 1
630
33.5 dia.Roller
60 dia.
450Leg spacing
700
to 8
00Li
ne h
eigh
ts
800
500
(345)271
(80º)
755Leg spacing
390Effective detection width
220
Pas
s he
ight
610
to 7
10
Units:mm
KD7417BWH
StandardKD74 series
StandardKD74 series
KD7416AWH
For Packaged Products
KD
74 seriesK
D74
-h series
KD
74-f series
For Specific ApplicationsD
ualX
KD7416AWH/ADWH/BWH/BDWH Maximum width Maximum height
Detection area: 390 mm × 150 mm
KD7417BWH Maximum width Maximum height
Detection area: 390 mm × 220 mm
X-ray Inspection System
6
■ Specifications
Model KD7405ABWH KD7416ABWHDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 240 mm, maximum height 50 mm Maximum width 390 mm, maximum height 50 mmBelt width 270 mm 420 mmPreset memory Maximum 100
Belt speed 4
Maximum product weight 55 to 50 m/min, maximum 5 kg5 to 40 m/min, maximum 10 kg (optional)
Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 230 kg 280 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).
External Dimensions
50
200※355
730
※88
0465
※54
026
5※
34023
2※
382
240※390
Detection area
270/※
420
Bel
t wid
th
132
1430
1360
1000
435
33.5 dia.Roller
Hopper
Interlock
915
to 1
015
※95
5 to
105
5
1360
to 1
460
※15
30 to
163
0
700
to 8
00Li
ne h
eigh
ts
650
to 7
50
60 dia.
450Leg spacing 605/※755
Leg spacing
196※271
50 Pas
s he
ight
240/※390Effective detection width
Units:mm
KD7405ABWH KD7416ABWH *
StandardKD74 series
KD7405ABWH
Enter the curtain in stable position
Become unstable at the joint
Become unstable by the curtain
Pass over the joint in stable position
KD7405ADWH / KD7405BDWH
A shield plate and a x-ray leakage prevention cover prevent x-ray leakage.
For Bulk Flow of Unpacked Fresh Food
KD
74 seriesK
D74
-h series
KD
74-f series
For Specific ApplicationsD
ualX
KD7405ABWH Maximum width Maximum height
Detection area: 240 mm × 50 mm
KD7416ABWH Maximum width Maximum height
Detection area: 390 mm × 50 mm
X-ray Inspection System
7
■ Specifications
Model KD7405ACWH KD7416ACWHDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 240 mm, maximum height 50 mm Maximum width 390 mm, maximum height 50 mmBelt width 270 mm 420 mmPreset memory Maximum 100
Belt speed 4
Maximum product weight 55 to 50 m/min, maximum 5 kg5 to 40 m/min, maximum 10 kg (optional)
Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 230 kg 285 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).
External Dimensions
Detection area
50
200※355
240※390
730
※88
0465
※54
026
5※
340
270/※
420
Bel
t wid
th
500
1268
1340 to 1355
1420
to 1
550
※15
90 to
172
0
760
to 8
90
605/※755Leg spacing
196※271
240/※390Effective detection width
700
to 8
00Li
ne h
eigh
ts
60 dia.450
Leg spacing
10 to 15º 30 to
50
Pas
s he
ight
Units:mm
KD7405ACWHKD7416ACWH *
StandardKD74 series
StandardKD74 series
KD7405ACWHEnter the curtain in stable position
Become unstable at the joint
Become unstable by the curtain
Pass over the joint in stable position
KD7405ADWH / KD7405BDWH
Instead of x-ray protection curtains that could disrupt product flow, an inclined conveyor with covers is equipped for stable conveyance.
For Lightweight Products and Those in Small Bags
KD
74 seriesK
D74
-h series
KD
74-f series
For Specific ApplicationsD
ualX
KD7405ACWH Maximum width Maximum height
Detection area: 240 mm × 50 mm
KD7416ACWH Maximum width Maximum height
Detection area: 390 mm × 50 mm
X-ray Inspection System
8
■ Specifications
Model KD7405CWT KD7405DWTDetection sensitivity 1 Fe sphere and SUS sphere 0.2 mm dia. 2, SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 300 W Tube voltage 25 to 80 kV, tube current 0.3 to 10.0 mA, output 7.5 to 350 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 3, 4 Maximum width 240 mm, maximum height 120 mmBelt width 270 mmPreset memory Maximum 100
Belt speed 5
Maximum product weight 6
10 to 60 m/min, maximum 5 kg61 to 90 m/min, maximum 2 kg5 to 40 m/min, maximum 10 kg (optional)
Power requirements 7, 8, 9 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 230 kgEnvironmental conditions 10 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: Reference value using Anritsu test piece. 3: The product size should fall below the detection area. 4: The entrance and exit may require covers depending on the length of a product. 5: Variable depending on Product No. 6: Sum total of product weight on the conveyor. 7: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 8: Allowable power fluctuation range is ±10%. 9: Installing the air-conditioner option changes the displayed power consumption. 10: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).
External Dimensions
120
240
160
Detection area
270
Bel
t wid
th
730
265
465
33.5 dia.Roller
605Leg spacing
450Leg spacing
196
240Effective detection width
(240)
120
Pas
s he
ight
(80º)
700
to 8
00Li
ne h
eigh
ts 1360
to 1
460
500
800
590
to 6
90
60 dia.
Units:mm
KD7405CWTKD7405DWT
High DefinitionKD74-h series
KD7405DWT
For Packaged Products
KD
74-h
seriesK
D74 series
KD
74-f series
For Specific ApplicationsD
ualX
KD7405CWT/DWT Maximum width Maximum height
Detection area: 240 mm × 120 mm
X-ray Inspection System
9
■ Specifications
Model KD7405DWH KD7416DWH KD7417DWHDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 80 kV, tube current 0.3 to 10.0 mA, output 7.5 to 350 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 240 mm, maximum height 120 mm Maximum width 390 mm, maximum height 150 mm Maximum width 390 mm, maximum height 220 mmBelt width 270 mm 420 mmPreset memory Maximum 100
Belt speed 4
Maximum product weight 5
10 to 60 m/min, maximum 5 kg 5 to 60 m/min, maximum 5 kg 5 to 40 m/min, maximum 10 kg61 to 90 m/min, maximum 2 kg 5 to 40 m/min, maximum 10 kg (optional) ー5 to 40 m/min, maximum 10 kg (optional) ー ー
Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 230 kg 280 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).
External Dimensions
120
240
160
Detection area
270
Bel
t wid
th
730
265
465
33.5 dia.Roller
605Leg spacing
450Leg spacing
196
240Effective detection width
(240)
120
Pas
s he
ight
(80º)
700
to 8
00Li
ne h
eigh
ts 1360
to 1
460
500
800
590
to 6
90
60 dia.
Units:mm
KD7405DWH
(80º)
420
Bel
t wid
th
33.5 dia.Roller
60 dia.
450Leg spacing
755Leg spacing
(280)※(345)
390Effective detection width
700
to 8
00Li
ne h
eigh
ts 1530
to 1
630
880
540
340
150/※
220
Pas
s he
ight
150
※22
0
280※230
271
500
800
390
Detection area
600
to 7
00※
610
to 7
10
Units:mm
KD7416DWHKD7417DWH *
High DefinitionKD74-h series
High DefinitionKD74-h series
KD7416DWH
For Packaged Products
KD
74-h
seriesK
D74 series
KD
74-f series
For Specific ApplicationsD
ualX
KD7405DWH Maximum width Maximum height
Detection area: 240 mm × 120 mm
KD7416DWH Maximum width Maximum height
Detection area: 390 mm × 150 mm
KD7417DWH Maximum width Maximum height
Detection area: 390 mm × 220 mm
X-ray Inspection System
10
■ Specifications
Model KD7405KP KD7405KDP KD7405KCPDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 50 kV, tube current 0.3 to 4.0 mA, output 7.5 to 100 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 240 mm, maximum height 120 mm Maximum width 240 mm, maximum height 50 mmBelt width 270 mmPreset memory Maximum 100
Belt speed 4
Maximum product weight 5
5 to 60 m/min, maximum 3 kg 5 to 50 m/min, maximum 3 kg61 to 80 m/min, maximum 2 kg 5 to 35 m/min, maximum 6 kg (optional)5 to 35 m/min, maximum 6 kg (optional) ー
Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 700 VA, rush current 80 A (typ.) (5 ms or less)Mass 200 kg 205 kg 220 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP40, tool free belt removalExterior Stainless steel (SUS304)
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 72 dB(A).
External Dimensions
120
240
160
Detection area
270
Bel
t wid
th
(470
)
(425
)
465
715
250
(195º)
(175º)
60 dia.
450Leg spacing
605Leg spacing
33.5 dia.Roller
700
to 8
00Li
ne h
eigh
ts
500
195
710
800/※1000
120
Pas
s he
ight
(90º)
1360
to 1
460
580
to 6
80 (240)
240Effective detection width
Units:mm
KD7405KPKD7405KDP *
(175º)
(265)
195
(90º)
(425
)
250
50465
715
270
Bel
t wid
th
33.5 dia.Roller
60 dia.450
Leg spacing 605
Leg spacing
240Effective detection width
(195º)
(470
)
1340 to 1355
10 to 15º
760
to 8
90
610
to 7
401420
to 1
550
700
to 8
00Li
ne h
eigh
ts
30 to
50
Pas
s he
ight
1268
500
240
200
Detection area
Units:mm
KD7405KCP
EntryKD74-f series
KD7405KP
For Packaged Products
KD
74-f series
KD
74 seriesK
D74
-h series
For Specific ApplicationsD
ualX
KD7405KP/KDP Maximum width Maximum height
Detection area: 240 mm × 120 mm
KD7405KCP Maximum width Maximum height
Detection area: 240 mm × 50 mm
For Lightweight Products and Those in Small Bags
X-ray Inspection System
11
External Dimensions
150
390
280
Detection area
880
540
340
420
Bel
t wid
th15
30 to
163
0
33.5 dia.Roller
60 dia.
450Leg spacing
700
to 8
00Li
ne h
eigh
ts
800/※1000
500
(280)271
(80º)
755Leg spacing
390Effective detection width
150
Pas
s he
ight
600
to 7
00
Units:mm
KD7416AWZEKD7416ADWZE *
EntryKD74-f series
DualXKD74 series
KD7416AWZE
For Packaged Products
KD
74 seriesK
D74
-h series
KD
74-f series
Du
alXFor Specific Applications
Detection area
50
355
390
880
540
340
420
Bel
t wid
th500
1268
1340 to 1355
1590
to 1
720
760
to 8
90
755Leg spacing
271
390Effective detection width
700
to 8
00Li
ne h
eigh
ts
60 dia.450
Leg spacing
10 to 15º 30 to
50
Pas
s he
ight
Units:mm
KD7416ACWZE
■ Specifications
Model KD7416AWZE KD7416ADWZE KD7416ACWZEX-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 1, 2 Maximum width 390 mm, maximum height 150 mm Maximum width 390 mm, maximum height 50 mmBelt width 420 mmPreset memory Maximum 100
Belt speed 3
Maximum product weight 410 to 60 m/min, maximum 5 kg 10 to 50 m/min, maximum 5 kg10 to 40 m/min, maximum 10 kg (optional) 10 to 40 m/min, maximum 10 kg (optional)
Power requirements 5, 6, 7 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 255 kg 260 kg 285 kgEnvironmental conditions 8 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)
1: The product size should fall below the detection area. 2: The entrance and exit may require covers depending on the length of a product. 3: Variable depending on Product No. 4: Sum total of product weight on the conveyor. 5: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 6: Allowable power fluctuation range is ±10%. 7: Installing the air-conditioner option changes the displayed power consumption. 8: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems does not exceed 70 dB(A).
KD7416AWZE/ADWZE Maximum width Maximum height
Detection area: 390 mm × 150 mm
KD7416ACWZE Maximum width Maximum height
Detection area: 390 mm × 50 mm
For Lightweight Products and Those in Small Bags
X-ray Inspection System
12
For Specific ApplicationsK
D74 series
KD
74-h
seriesK
D74
-f seriesD
ualX
■ Specifications
Model KD7416DWZX-ray output Tube voltage 25 to 80 kV, tube current 0.4 to 10.0 mA, output 10 to 350 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesSafety 15-inch color TFT LCD (unified image monitoring screen and operation screen)Display Touch panel (with touch buzzer)Detection area 1, 2 Maximum width 390 mm, maximum height 150 mmBelt width 420 mmPreset memory Maximum 100
Belt speed 3
Maximum product weight 45 to 60 m/min, maximum 5 kg5 to 40 m/min, maximum 10 kg (optional)
Power requirements 5, 6, 7 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 280 kgEnvironmental conditions 8 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)
1: The product size should fall below the detection area. 2: The entrance and exit may require covers depending on the length of a product. 3: Variable depending on Product No. 4: Sum total of product weight on the conveyor. 5: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 6: Allowable power fluctuation range is ±10%. 7: Installing the air-conditioner option changes the displayed power consumption. 8: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).
External Dimensions
150
390
280
Detection area
880
540
340
420
Bel
t wid
th15
30 to
163
0
33.5 dia.Roller
60 dia.
450Leg spacing
700
to 8
00Li
ne h
eigh
ts
800
500
(280)271
(80º)
755Leg spacing
390Effective detection width
150
Pas
s he
ight
600
to 7
00
Units:mm
KD7416DWZ
DualXKD74 series
KD7416DWZ
For Packaged Products
KD7416DWZ Maximum width Maximum height
Detection area: 390 mm × 150 mm
X-ray Inspection System
13
■ Specifications
Model KD7447DW KD7447DWE KD7447FWEDetection sensitivity 1 Fe sphere and SUS sphere 0.4 mm dia. Fe sphere and SUS sphere 0.5 mm dia. Fe sphere and SUS sphere 0.8 mm dia.X-ray output Tube voltage 25 to 80 kV, tube current 0.3 to 10.0 mA, output 7.5 to 350 W Tube voltage 80 to 100 kV, tube current 0.5 to 4.3 mA, output 40 to 350 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 590 mm, maximum height 250 mmBelt width 620 mmPreset memory Maximum 100
Belt speed 4
Maximum product weight 5
10 to 35 m/min, maximum 50 kg 10 to 35 m/min, maximum 50 kg 7
36 to 40 m/min, maximum 30 kg 6 36 to 40 m/min, maximum 30 kg 7
25 to 50 m/min, maximum 20 kg (optional) 25 to 50 m/min, maximum 20 kg (optional) 7
Power requirements 8, 9, 10 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)
200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)
Mass 450 kg 650 kgEnvironmental conditions 11 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The entrance and exit may require covers depending on the length of a product. 3: Pass height of 350 mm is available as an option. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: In an environment where water or oil regularly splashes the equipment, the maximum is 20 kg. 7: Can decrease if the conveyor is exposed to water or oil. 8: Allowable power fluctuation range is ±10%. 9: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 10: Installing the air-conditioner option changes the displayed power consumption. 11: The air-conditioner option may be required depending on the operating environment. Note: The noise level of KD7447DW/KD7447DWE does not exceed 70 dB(A). The noise level of KD7447FWE is 72 dB (A).
External Dimensions
690
1114
424
1200
500
700
to 8
00Li
ne h
eigh
ts
49.5 dia.Roller
836Leg spacing
975Leg spacing
80 dia.
350
590Effective detection width
1806
to 1
906
250
Pas
s he
ight
(484
)
(471
)62
0B
elt w
idth
590
410
250
Detection area
Units:mm
KD7447DWKD7447DWE
For Specific Applications Large Products and Cartons
KD74 series
KD7447DW
For Packaged Products
For Specific ApplicationsK
D74 series
KD
74-h
seriesK
D74
-f seriesD
ualX
620
300
690
463
1153
(471
)(8
00)
1200
Maintenancespace
Maintenancespace
49.5 dia.Roller
700
to 8
00
82580 dia.
250
590
388
1906
to 2
006
(150
0)
Bel
t wid
th
Line
hei
ghts
Leg spacing 1013
Leg spacing
Pas
s he
ight
Effective detection width
500
590
410
250
Detection area
Units:mm
KD7447FWE
DualXKD74 series
KD7447DW/DWE/FWE Maximum width Maximum height
Detection area: 590 mm × 250 mm
X-ray Inspection System
14
■ Specifications
Model KD7416AM KD7416ACMDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 365 mm, maximum height 150 mm Maximum width 365 mm, maximum height 50 mmBelt width 420 mmPreset memory Maximum 100
Belt speed 4
Maximum product weight 55 to 40 m/min, maximum 5 kg 5 to 50 m/min, maximum 3 kg5 to 35 m/min, maximum 10 kg (optional) 5 to 35 m/min, maximum 8 kg (optional)
Power requirements 6, 7 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.6 kVA, rush current 80 A (typ.) (5 ms or less)Mass 335 kg 355 kgEnvironmental conditions Temperature: 0º to 35ºC, relative humidity: 30% to 85%, non-condensingProtection class 8 IP69K (with all protection covers closed)Exterior Stainless steel (SUS304)Cooling system Air conditioner (standard equipped)
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Excluding air-conditioner ventilation hole. Note: The noise level of x-ray inspection systems is 82 dB(A).
External Dimensions
(610)
(420)
(410) 270
(365
)
(380
)42
0B
elt w
idth
60 dia.450
Leg spacing 755
Leg spacing
365Effective detection width
(590
)
(550
to 6
10)15
40 to
160
014
30
1380
480
900
540
360
720
to 7
80Li
ne h
eigh
ts
33.5 dia.Roller
33.5 dia.Roller
800
500
150
Pas
s he
ight
(90º
)
(200
º)
(105º)
(140º)
Air conditioner
150
365
255
Detection area
Units:mm
KD7416AM
(610)
(185)
(170)
(365
)
(380
)42
0B
elt w
idth
60 dia.450
Leg spacing
(410) 270
755Leg spacing
365Effective detection width
(590
)
610
to 7
00
780
to 8
70 1600
to 1
690
1430
1380
480
900
540
360
720
to 7
80Li
ne h
eigh
ts
33.5 dia.Roller
48 dia.Roller
5001270
1360 to 13751340 to 1355
30 to
50
Pas
s he
ight
(90°
)
120°
(200
º)
(105º)
(125º)
10 to 15º
Air conditioner
Detection area
50
330
365
Units:mm
KD7416ACM
For Specific Applications Sanitary Design
KD74 series
KD7416ACMAir conditioner is equipped as standard.
For Specific ApplicationsK
D74 series
KD
74-h
seriesK
D74
-f seriesD
ualX
KD7416AM Maximum width Maximum height
Detection area: 365 mm × 150 mm
KD7416ACM Maximum width Maximum height
Detection area: 365 mm × 50 mm
For Packaged Products
For Unpackaged Fresh Meat, Poultry and Fish
KD7416ADM (1000-mm long) and KD7416ABM (Hopper loading system) are also available. Contact our sales representatives for details.
X-ray Inspection System
15
For Specific Applications Sanitary Design
KD74 series
For Specific ApplicationsK
D74 series
KD
74-h
seriesK
D74
-f seriesD
ualX
■ Specifications
Model KD7478AWH KD7478BWHDetection sensitivity 1 Fe sphere and SUS sphere 0.4 mm dia.X-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 W Tube voltage 25 to 80 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 120 mm, maximum height 350 mmBelt width 120 mmPreset memory Maximum 100
Belt speed 4
Maximum product weight 5 5 to 60 m/min, maximum 5 kg
Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 310 kg 315 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems does not exceed 70 dB(A).
External Dimensions
55
905
520
385
1455
1400
500
120
Bel
t wid
th
350
Pass
hei
ght
712Leg spacing
382
150Effective detection width
60 dia.
450Leg spacing
700
to 8
00Li
ne h
eigh
ts15
05 to
160
5
33.5 dia.Roller
IN OUT
150
307
237
Detection area
Units:mm
KD7478AWHKD7478BWH
Flow direction can be changed.
For Specific Applications Tall Products
KD74 series
KD7478AWH
For Packaged Products
KD7478AWH/BWH Maximum width Maximum height
Detection area: 120 mm × 350 mm
Note: Not usable for glass containers.
X-ray Inspection System
16
■ Specifications
Model KD7483AFWHDetection sensitivity 1 Fe sphere and SUS sphere 0.6 mm dia. (when only water is conveyed)X-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)
Product sizeProduct: solids in fluid
12 mm or smaller (less than 1/3 of the minimum height of the inspection section)
Transfer pipe dimension 3-inch (76.2 mm) dia.Inspection section pass height 35 mm (fixed)Position change at sensitivity adjustment Main unit position change (pipe position fixed)Preset memory Maximum 100Processing capacity (flow) 11.0 kℓ/hPower requirements 2, 3 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.6 kVA, rush current 80 A (typ.) (5 ms or less)Mass 340 kgEnvironmental conditions Temperature: 0ºC to 40ºC, relative humidity: 30% to 85%, non-condensingProtection class Product transfer pipe IP66, other parts IP40Exterior Stainless steel (SUS304)Cooling system Air conditioner (standard equipped)
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: Allowable power fluctuation range is ±10%. 3: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. Note: The noise level of x-ray inspection systems is 71 dB(A).
External Dimensions
(170º)
(170º)
880
to 9
80Li
ne h
eigh
ts
990
to 1
090
Join
t hei
ghts
770
to 8
70Jo
int h
eigh
ts
560Leg spacing
1280Leg spacing
Clamp Union Fittings 3.0 S
80 dia.
165
124
226100
1400
1074
165
890
379 901
(250
)
(470
)
(80º
)
130Stroke width
350Stroke width
Air conditioner
110
1480
to 1
580
Units:mm
KD7483AFWH
For Specific Applications Pipe type
KD74 series
KD7483AFWH Solids in fluid
Product size: 12 mm (Less than 1/3 of the minimum height of the inspection section)
KD7483AFWHAir conditioner is equipped as standard.
For Pumped Products
KD
74 seriesK
D74
-h series
KD
74-f series
For Specific ApplicationsD
ualX
17
X-ray Inspection System
160
Bel
t wid
th40
5
700
to 8
00Li
ne h
eigh
ts
1310
to 1
410
1140
to 1
240
1580
to 1
680
Tower light
290
695
475
260
460
550
Leg spacing
520
Leg spacing
Detection area
100
30
For Specific Applications Pipe type
KD74 series
For Specific ApplicationsK
D74 series
KD
74-h
seriesK
D74
-f seriesD
ualX
■ Specifications
Model KD7490LYNApplication size 1 Width: maximum 100 mm, Height: maximum 30 mm, Length: maximum 230 mmSafety X-ray leakage: Max 1μSv/h or less, Prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with buzzer)Preset memory Maximum 100
Belt speed 2
Maximum product weight 3 10 to 40 m/min, Maximum 0.5 kg
Power requirement 4 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 300 VAMass 160 kgEnvironmental conditions Temperature: 10ºC to 30ºC, relative humidity: 30% to 85%, air pressure: 700 to 1060 hPa, non-condensingProtection class IP30Exterior Stainless steel (SUS304)
1: Width of 160 mm is available as an option. 2: Variable depending on Product No. 3: Sum total of product weight on the conveyor. 4: Allowable power fluctuation range is ±10%. Note: Noise level does not exceed 70 dB(A).
External Dimensions
Units:mm
KD7490LYN
For Specific Applications Pharmaceutical
KD74 series
KD7490LYN
For Pharmaceutical Products
KD7490LYN Maximum width Maximum height
Detection area: 100 mm × 30 mm
Safety management
It is your responsibility to check and ensure that you comply with all applicable laws and regulations of your country or region regarding the effect of x-ray exposure on pharmaceutical products. Anritsu conducted a research with the Nagoya City University about the effect of x-rays on the pharmaceutical quality of drug tablets and found that exposure to x-rays did not affect pharmaceutical quality of the drug content.
We exposed comercially available non-steroidal anti-inflammatory drugs (acetaminophen, loxoprofen and mefenamic acid) to x-rays of various doses from 0.34 mGy to 300 Gy, and evaluated the quality of the tablets using pharmaceutical tests. We found the samples exposed to x-rays exhibited almost the same profile in the tests as control samples (0 Gy). We also investigated the influences of heat and humidity on drug tablets after x-ray exposure, and confirmed that the combination of x-ray exposure with accelerated temperature and humidity tests (40ºC, relative humidity 75%) also did not affect the phermaceutical quality. For more details, refer to the full report at http://informahealthcare.com/ddi
18
X-ray Inspection System
Anritsu believes customer safety is of utmost importance.
Anritsu safety mechanism
Safety management
Safety of inspected products
Emergency stop switchCuts power to x-ray and drive circuits, stops the conveyor and x-ray radiation.
X-ray irradiation displayThe lamp is lit during x-ray radiation.
Leakage prevention curtainPrevents x-ray leakage. For unpackaged or bulk products, the standard lead impregnated curtains are replaced with SUS covers - preventing direct food contact with the curtains.
Hand insertion sensorInterrupting the sensor for a certain period of time stops x-ray radiation.
X-ray ON/OFF keyTurning the key to OFF stops x-ray radiation completely.
X-ray shield cover open/close sensorOpening the cover stops x-ray radiation.
X-ray shield coverOpened/Closed using x-ray Irradiation ON/OFF Key. Opening the cover stops x-ray radiation due to the x-ray Shield Cover Open/Close Sensor.
X-ray Inspection System has been designed to fully satisfy the safe operation. However, to ensure even higher safety, use the safety procedures outlined below.
1
3
Periodic measurement and recording of x-ray leakage data
Additional safety measuresCovers may need to be mounted on upstream and downstream conveyors instead of the shield curtains, depending on the shape, weight, and package of products.
2
4
Management of operator working hours
No disassembly or modificationNEVER modify or disassemble the main unit, covers, x-ray leakage prevention curtains, safety covers, safety interlocks, etc., otherwise the x-ray leak-proof design may no longer be functional.
WHO concluded in 1980 that the “irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard and introduces no special nutritional or microbiological problems.”The maximum dose of x-ray irradiation to the products to be inspected by our x-ray inspection systems is 0.002 Gy, which is much lower than the value described above. Even if a product stops inside, the x-ray dose is always kept to 0.1 Gy or less.
Note: Follow the local laws and regulations regarding the installation and use of the x-ray inspection systems.
Safety in design
19
Note
X-ray Inspection System
KD74
KD74-h
KD74-f
DualX
For Specific Applications
May 2017
2017-5 10 (ddc) Printed in JapanCAT. NO. K3175-E-1
2014