X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model...

20
X-ray Inspection System KD74 KD74-h KD74-f DualX For Specific Applications May 2017

Transcript of X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model...

Page 1: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

KD74

KD74-h

KD74-f

DualX

For Specific Applications

May 2017

Page 2: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

Product Catalog

L i n e u p

StandardKD74 series

Products Dry products Wet products

Protection class IP40 IP66

X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)

Product range ●Size variations

Highly versatile system with a proven track record suits a wide range of packaged products.

Simultaneous inspection including shape analysis, missing item and package integrity inspection

are available.

EntryKD74-f series

Products Dry products Wet products

Protection class IP40 IP66

X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)

Product range ●Size variations

With low X-ray output and simple construction, this series are suitable for dry products.

DualX

Products Dry products Wet products

Protection class IP40 IP66

X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)

Product range ● High power ● Low power

Analyzing two different x-ray energy signals, it clearly distinguishes contaminants from products.

Performs accurate inspection of low density bones in meat and overlapping products.

For Specific Applications

●Large bags and cartons ●Tall products ●Pharmaceutical

●Sanitary design ●Pipe type

X-ray systems in a variety of configurations offered to fit specific inspection requirements.

High DefinitionKD74-h series

Products Dry products Wet products

Protection class IP40 IP66

X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)

Product range ●For metal particles ●For low density contaminants ●Size variations

High accuracy detection technology detects a 0.2 diameter metal sphere. Suitable for soft

contaminants that are of low-density, such as bone and plastics, as well as for minute metal

particles.

2

Page 3: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

Product Catalog

L i n e u p

StandardKD74 series

Products Dry products Wet products

Protection class IP40 IP66

X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)

Product range ●Size variations

Highly versatile system with a proven track record suits a wide range of packaged products.

Simultaneous inspection including shape analysis, missing item and package integrity inspection

are available.

EntryKD74-f series

Products Dry products Wet products

Protection class IP40 IP66

X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)

Product range ●Size variations

With low X-ray output and simple construction, this series are suitable for dry products.

DualX

Products Dry products Wet products

Protection class IP40 IP66

X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)

Product range ● High power ● Low power

Analyzing two different x-ray energy signals, it clearly distinguishes contaminants from products.

Performs accurate inspection of low density bones in meat and overlapping products.

For Specific Applications

●Large bags and cartons ●Tall products ●Pharmaceutical

●Sanitary design ●Pipe type

X-ray systems in a variety of configurations offered to fit specific inspection requirements.

High DefinitionKD74-h series

Products Dry products Wet products

Protection class IP40 IP66

X-ray output Low (max. 100W) Middle to High (max. 210W) High (max. 350W)

Product range ●For metal particles ●For low density contaminants ●Size variations

High accuracy detection technology detects a 0.2 diameter metal sphere. Suitable for soft

contaminants that are of low-density, such as bone and plastics, as well as for minute metal

particles.

Note: Any one of the pass heights can be selected.

Model Detection area (Units:mm) Page

KD7405AWH/ADWH /BWH/BDWH W2 (160)

W1 (240)

H (

120)

Effective detection width = 240 –

80×Hp120

Effective detection height=120×(240–Wp)

80

4

KD7405CWT/DWTKD7405DWH 8, 9

KD7405KP/KDP 10

KD7405ABWH

W2 (200)

W1 (240)

H(50

)

Effective detection width = 240 –

40×Hp50

Effective detection height=50×(240–Wp)

40

6

KD7405ACWH 7

KD7405KCP 10

KD7416AWH/ADWH /BWH/BDWH W2 (280)

W1 (390)

H (

150)

Effective detection width= 390 –

110×Hp150

Effective detection height=150×(390–Wp)

110

5

KD7416DWH 9

KD7416AWZE/ADWZEKD7416DWZ 11, 12

KD7416ABWH

W2 (355)

W1 (390)

H (50) Effective detection width= 390 –

35×Hp50

Effective detection height=50×(390–Wp)

35

6

KD7416ACWH 7

KD7416ACWZE 11

KD7417BWH W2 (230)

W1 (390)H

(22

0)

Effective detection width= 390 –

160×Hp220

Effective detection height=220×(390–Wp)

160

5

KD7417DWH9

KD7447DWKD7447DWEKD7447FWE

W2 (410)

W1 (590)

H (

250)

Effective detection width= 590 –

180×Hp250

Effective detection height=250×(590–Wp)

180

13●Pass height: 350 mm (Optional)

H (

350)

W2 (335)

W1 (590)

Effective detection width= 590 –255×Hp

350

Effective detection height=350×(590–Wp)

255

KD7416AM W2 (255)

W1 (365)

H (

150)

Effective detection width= 365 –

110×Hp150

Effective detection height=150×(365–Wp)

110

14

KD7416ACMW2 (330)

W1 (365)

H (50) Effective detection width= 365 –

35×Hp50

Effective detection height=50×(365–Wp)

35

14

KD7478AWHKD7478BWH

W (150)

H1

(307

)

H2

(237

) Effective detection width=150×(307–Hp)

70

Effective detection height= 307–70×Wp

150

15

KD7490LYN

W(100)H(30)

Effective detection width =100

Effective detection height= 3017

Model Selection List

Products

3

● When Hp ≦ 237: Effective detection width = 150

● When 237 < Hp ≦ 307:

Page 4: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

4

■ Specifications

Model KD7405AWH KD7405ADWH KD7405BWH KD7405BDWHDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 W Tube voltage 25 to 80 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 240 mm, maximum height 120 mmBelt width 270 mmPreset memory Maximum 100

Belt speed 4

Maximum product weight 5

5 to 60 m/min, maximum 5 kg61 to 90 m/min, maximum 2 kg5 to 40 m/min, maximum 10 kg (optional)

Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 210 kg 215 kg 220 kg 225 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)

1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).

External Dimensions

240

590

to 6

90

196

(80º)

73046

526

513

60 to

146

0

270

Bel

t wid

th

33.5 dia.Roller

60 dia.

450Leg spacing

605Leg spacing

240Effective detection width

700

to 8

00Li

ne h

eigh

ts

120

Pas

s he

ight

800/※1000

500

120

240

160

Detection area

Units:mm

KD7405AWH KD7405ADWH *KD7405BWH KD7405BDWH *

StandardKD74 series 

KD7405AWH/ADWH/BWH/BDWH Maximum width Maximum height

Detection area: 240 mm × 120 mm

KD7405AWH

Enter the curtain in stable position

Become unstable at the joint

Become unstable by the curtain

Pass over the joint in stable position

KD7405ADWH / KD7405BDWH

The conveyor is lengthened from 800 to 1000 for smooth product transfer.

For Packaged Products

KD

74 seriesK

D74

-h series

KD

74-f series

For Specific ApplicationsD

ualX

Page 5: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

5

■ Specifications

Model KD7416AWH KD7416ADWH KD7416BWH KD7416BDWH KD7417BWHDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm long

X-ray outputTube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 W

Tube voltage 25 to 80 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 W

Safety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)

Detection area 2, 3 Maximum width 390 mm, maximum height 150 mmMaximum width 390 mm, maximum height 220 mm

Belt width 420 mmPreset memory Maximum 100

Belt speed 4

Maximum product weight 55 to 60 m/min, maximum 5 kg 5 to 40 m/min, maximum 10 kg5 to 40 m/min, maximum 10 kg (optional) ー

Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 255 kg 260 kg 265 kg 270 kg 265 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)

1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).

External Dimensions

150

390

280

Detection area

880

540

340

420

Bel

t wid

th15

30 to

163

0

33.5 dia.Roller

60 dia.

450Leg spacing

700

to 8

00Li

ne h

eigh

ts

800/※1000

500

(280)271

(80º)

755Leg spacing

390Effective detection width

150

Pas

s he

ight

600

to 7

00

Units:mm

KD7416AWH KD7416ADWH *KD7416BWH KD7416BDWH *

220

390

230

Detection area

880

540

340

420

Bel

t wid

th

1530

to 1

630

33.5 dia.Roller

60 dia.

450Leg spacing

700

to 8

00Li

ne h

eigh

ts

800

500

(345)271

(80º)

755Leg spacing

390Effective detection width

220

Pas

s he

ight

610

to 7

10

Units:mm

KD7417BWH

StandardKD74 series 

StandardKD74 series 

KD7416AWH

For Packaged Products

KD

74 seriesK

D74

-h series

KD

74-f series

For Specific ApplicationsD

ualX

KD7416AWH/ADWH/BWH/BDWH Maximum width Maximum height

Detection area: 390 mm × 150 mm

KD7417BWH Maximum width Maximum height

Detection area: 390 mm × 220 mm

Page 6: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

6

■ Specifications

Model KD7405ABWH KD7416ABWHDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 240 mm, maximum height 50 mm Maximum width 390 mm, maximum height 50 mmBelt width 270 mm 420 mmPreset memory Maximum 100

Belt speed 4

Maximum product weight 55 to 50 m/min, maximum 5 kg5 to 40 m/min, maximum 10 kg (optional)

Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 230 kg 280 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)

1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).

External Dimensions

50

200※355

730

※88

0465

※54

026

5※

34023

2※

382

240※390

Detection area

270/※

420

Bel

t wid

th

132

1430

1360

1000

435

33.5 dia.Roller

Hopper

Interlock

915

to 1

015

※95

5 to

105

5

1360

to 1

460

※15

30 to

163

0

700

to 8

00Li

ne h

eigh

ts

650

to 7

50

60 dia.

450Leg spacing 605/※755

Leg spacing

196※271

50 Pas

s he

ight

240/※390Effective detection width

Units:mm

KD7405ABWH KD7416ABWH *

StandardKD74 series 

KD7405ABWH

Enter the curtain in stable position

Become unstable at the joint

Become unstable by the curtain

Pass over the joint in stable position

KD7405ADWH / KD7405BDWH

A shield plate and a x-ray leakage prevention cover prevent x-ray leakage.

For Bulk Flow of Unpacked Fresh Food

KD

74 seriesK

D74

-h series

KD

74-f series

For Specific ApplicationsD

ualX

KD7405ABWH Maximum width Maximum height

Detection area: 240 mm × 50 mm

KD7416ABWH Maximum width Maximum height

Detection area: 390 mm × 50 mm

Page 7: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

7

■ Specifications

Model KD7405ACWH KD7416ACWHDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 240 mm, maximum height 50 mm Maximum width 390 mm, maximum height 50 mmBelt width 270 mm 420 mmPreset memory Maximum 100

Belt speed 4

Maximum product weight 55 to 50 m/min, maximum 5 kg5 to 40 m/min, maximum 10 kg (optional)

Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 230 kg 285 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)

1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).

External Dimensions

Detection area

50

200※355

240※390

730

※88

0465

※54

026

5※

340

270/※

420

Bel

t wid

th

500

1268

1340 to 1355

1420

to 1

550

※15

90 to

172

0

760

to 8

90

605/※755Leg spacing

196※271

240/※390Effective detection width

700

to 8

00Li

ne h

eigh

ts

60 dia.450

Leg spacing

10 to 15º 30 to

50

Pas

s he

ight

Units:mm

KD7405ACWHKD7416ACWH *

StandardKD74 series 

StandardKD74 series 

KD7405ACWHEnter the curtain in stable position

Become unstable at the joint

Become unstable by the curtain

Pass over the joint in stable position

KD7405ADWH / KD7405BDWH

Instead of x-ray protection curtains that could disrupt product flow, an inclined conveyor with covers is equipped for stable conveyance.

For Lightweight Products and Those in Small Bags

KD

74 seriesK

D74

-h series

KD

74-f series

For Specific ApplicationsD

ualX

KD7405ACWH Maximum width Maximum height

Detection area: 240 mm × 50 mm

KD7416ACWH Maximum width Maximum height

Detection area: 390 mm × 50 mm

Page 8: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

8

■ Specifications

Model KD7405CWT KD7405DWTDetection sensitivity 1 Fe sphere and SUS sphere 0.2 mm dia. 2, SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 300 W Tube voltage 25 to 80 kV, tube current 0.3 to 10.0 mA, output 7.5 to 350 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 3, 4 Maximum width 240 mm, maximum height 120 mmBelt width 270 mmPreset memory Maximum 100

Belt speed 5

Maximum product weight 6

10 to 60 m/min, maximum 5 kg61 to 90 m/min, maximum 2 kg5 to 40 m/min, maximum 10 kg (optional)

Power requirements 7, 8, 9 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 230 kgEnvironmental conditions 10 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)

1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: Reference value using Anritsu test piece. 3: The product size should fall below the detection area. 4: The entrance and exit may require covers depending on the length of a product. 5: Variable depending on Product No. 6: Sum total of product weight on the conveyor. 7: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 8: Allowable power fluctuation range is ±10%. 9: Installing the air-conditioner option changes the displayed power consumption. 10: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).

External Dimensions

120

240

160

Detection area

270

Bel

t wid

th

730

265

465

33.5 dia.Roller

605Leg spacing

450Leg spacing

196

240Effective detection width

(240)

120

Pas

s he

ight

(80º)

700

to 8

00Li

ne h

eigh

ts 1360

to 1

460

500

800

590

to 6

90

60 dia.

Units:mm

KD7405CWTKD7405DWT

High DefinitionKD74-h series 

KD7405DWT

For Packaged Products

KD

74-h

seriesK

D74 series

KD

74-f series

For Specific ApplicationsD

ualX

KD7405CWT/DWT Maximum width Maximum height

Detection area: 240 mm × 120 mm

Page 9: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

9

■ Specifications

Model KD7405DWH KD7416DWH KD7417DWHDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 80 kV, tube current 0.3 to 10.0 mA, output 7.5 to 350 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 240 mm, maximum height 120 mm Maximum width 390 mm, maximum height 150 mm Maximum width 390 mm, maximum height 220 mmBelt width 270 mm 420 mmPreset memory Maximum 100

Belt speed 4

Maximum product weight 5

10 to 60 m/min, maximum 5 kg 5 to 60 m/min, maximum 5 kg 5 to 40 m/min, maximum 10 kg61 to 90 m/min, maximum 2 kg 5 to 40 m/min, maximum 10 kg (optional) ー5 to 40 m/min, maximum 10 kg (optional) ー ー

Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 230 kg 280 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)

1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).

External Dimensions

120

240

160

Detection area

270

Bel

t wid

th

730

265

465

33.5 dia.Roller

605Leg spacing

450Leg spacing

196

240Effective detection width

(240)

120

Pas

s he

ight

(80º)

700

to 8

00Li

ne h

eigh

ts 1360

to 1

460

500

800

590

to 6

90

60 dia.

Units:mm

KD7405DWH

(80º)

420

Bel

t wid

th

33.5 dia.Roller

60 dia.

450Leg spacing

755Leg spacing

(280)※(345)

390Effective detection width

700

to 8

00Li

ne h

eigh

ts 1530

to 1

630

880

540

340

150/※

220

Pas

s he

ight

150

※22

0

280※230

271

500

800

390

Detection area

600

to 7

00※

610

to 7

10

Units:mm

KD7416DWHKD7417DWH *

High DefinitionKD74-h series 

High DefinitionKD74-h series 

KD7416DWH

For Packaged Products

KD

74-h

seriesK

D74 series

KD

74-f series

For Specific ApplicationsD

ualX

KD7405DWH Maximum width Maximum height

Detection area: 240 mm × 120 mm

KD7416DWH Maximum width Maximum height

Detection area: 390 mm × 150 mm

KD7417DWH Maximum width Maximum height

Detection area: 390 mm × 220 mm

Page 10: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

10

■ Specifications

Model KD7405KP KD7405KDP KD7405KCPDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 50 kV, tube current 0.3 to 4.0 mA, output 7.5 to 100 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 240 mm, maximum height 120 mm Maximum width 240 mm, maximum height 50 mmBelt width 270 mmPreset memory Maximum 100

Belt speed 4

Maximum product weight 5

5 to 60 m/min, maximum 3 kg 5 to 50 m/min, maximum 3 kg61 to 80 m/min, maximum 2 kg 5 to 35 m/min, maximum 6 kg (optional)5 to 35 m/min, maximum 6 kg (optional) ー

Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 700 VA, rush current 80 A (typ.) (5 ms or less)Mass 200 kg 205 kg 220 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP40, tool free belt removalExterior Stainless steel (SUS304)

1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 72 dB(A).

External Dimensions

120

240

160

Detection area

270

Bel

t wid

th

(470

)

(425

)

465

715

250

(195º)

(175º)

60 dia.

450Leg spacing

605Leg spacing

33.5 dia.Roller

700

to 8

00Li

ne h

eigh

ts

500

195

710

800/※1000

120

Pas

s he

ight

(90º)

1360

to 1

460

580

to 6

80 (240)

240Effective detection width

Units:mm

KD7405KPKD7405KDP *

(175º)

(265)

195

(90º)

(425

)

250

50465

715

270

Bel

t wid

th

33.5 dia.Roller

60 dia.450

Leg spacing 605

Leg spacing

240Effective detection width

(195º)

(470

)

1340 to 1355

10 to 15º

760

to 8

90

610

to 7

401420

to 1

550

700

to 8

00Li

ne h

eigh

ts

30 to

50

Pas

s he

ight

1268

500

240

200

Detection area

Units:mm

KD7405KCP

EntryKD74-f series 

KD7405KP

For Packaged Products

KD

74-f series

KD

74 seriesK

D74

-h series

For Specific ApplicationsD

ualX

KD7405KP/KDP Maximum width Maximum height

Detection area: 240 mm × 120 mm

KD7405KCP Maximum width Maximum height

Detection area: 240 mm × 50 mm

For Lightweight Products and Those in Small Bags

Page 11: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

11

External Dimensions

150

390

280

Detection area

880

540

340

420

Bel

t wid

th15

30 to

163

0

33.5 dia.Roller

60 dia.

450Leg spacing

700

to 8

00Li

ne h

eigh

ts

800/※1000

500

(280)271

(80º)

755Leg spacing

390Effective detection width

150

Pas

s he

ight

600

to 7

00

Units:mm

KD7416AWZEKD7416ADWZE *

EntryKD74-f series 

DualXKD74 series 

KD7416AWZE

For Packaged Products

KD

74 seriesK

D74

-h series

KD

74-f series

Du

alXFor Specific Applications

Detection area

50

355

390

880

540

340

420

Bel

t wid

th500

1268

1340 to 1355

1590

to 1

720

760

to 8

90

755Leg spacing

271

390Effective detection width

700

to 8

00Li

ne h

eigh

ts

60 dia.450

Leg spacing

10 to 15º 30 to

50

Pas

s he

ight

Units:mm

KD7416ACWZE

■ Specifications

Model KD7416AWZE KD7416ADWZE KD7416ACWZEX-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 1, 2 Maximum width 390 mm, maximum height 150 mm Maximum width 390 mm, maximum height 50 mmBelt width 420 mmPreset memory Maximum 100

Belt speed 3

Maximum product weight 410 to 60 m/min, maximum 5 kg 10 to 50 m/min, maximum 5 kg10 to 40 m/min, maximum 10 kg (optional) 10 to 40 m/min, maximum 10 kg (optional)

Power requirements 5, 6, 7 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 255 kg 260 kg 285 kgEnvironmental conditions 8 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)

1: The product size should fall below the detection area. 2: The entrance and exit may require covers depending on the length of a product. 3: Variable depending on Product No. 4: Sum total of product weight on the conveyor. 5: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 6: Allowable power fluctuation range is ±10%. 7: Installing the air-conditioner option changes the displayed power consumption. 8: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems does not exceed 70 dB(A).

KD7416AWZE/ADWZE Maximum width Maximum height

Detection area: 390 mm × 150 mm

KD7416ACWZE Maximum width Maximum height

Detection area: 390 mm × 50 mm

For Lightweight Products and Those in Small Bags

Page 12: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

12

For Specific ApplicationsK

D74 series

KD

74-h

seriesK

D74

-f seriesD

ualX

■ Specifications

Model KD7416DWZX-ray output Tube voltage 25 to 80 kV, tube current 0.4 to 10.0 mA, output 10 to 350 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesSafety 15-inch color TFT LCD (unified image monitoring screen and operation screen)Display Touch panel (with touch buzzer)Detection area 1, 2 Maximum width 390 mm, maximum height 150 mmBelt width 420 mmPreset memory Maximum 100

Belt speed 3

Maximum product weight 45 to 60 m/min, maximum 5 kg5 to 40 m/min, maximum 10 kg (optional)

Power requirements 5, 6, 7 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 280 kgEnvironmental conditions 8 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)

1: The product size should fall below the detection area. 2: The entrance and exit may require covers depending on the length of a product. 3: Variable depending on Product No. 4: Sum total of product weight on the conveyor. 5: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 6: Allowable power fluctuation range is ±10%. 7: Installing the air-conditioner option changes the displayed power consumption. 8: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).

External Dimensions

150

390

280

Detection area

880

540

340

420

Bel

t wid

th15

30 to

163

0

33.5 dia.Roller

60 dia.

450Leg spacing

700

to 8

00Li

ne h

eigh

ts

800

500

(280)271

(80º)

755Leg spacing

390Effective detection width

150

Pas

s he

ight

600

to 7

00

Units:mm

KD7416DWZ

DualXKD74 series 

KD7416DWZ

For Packaged Products

KD7416DWZ Maximum width Maximum height

Detection area: 390 mm × 150 mm

Page 13: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

13

■ Specifications

Model KD7447DW KD7447DWE KD7447FWEDetection sensitivity 1 Fe sphere and SUS sphere 0.4 mm dia. Fe sphere and SUS sphere 0.5 mm dia. Fe sphere and SUS sphere 0.8 mm dia.X-ray output Tube voltage 25 to 80 kV, tube current 0.3 to 10.0 mA, output 7.5 to 350 W Tube voltage 80 to 100 kV, tube current 0.5 to 4.3 mA, output 40 to 350 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 590 mm, maximum height 250 mmBelt width 620 mmPreset memory Maximum 100

Belt speed 4

Maximum product weight 5

10 to 35 m/min, maximum 50 kg 10 to 35 m/min, maximum 50 kg 7

36 to 40 m/min, maximum 30 kg 6 36 to 40 m/min, maximum 30 kg 7

25 to 50 m/min, maximum 20 kg (optional) 25 to 50 m/min, maximum 20 kg (optional) 7

Power requirements 8, 9, 10 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)

200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)

Mass 450 kg 650 kgEnvironmental conditions 11 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)

1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The entrance and exit may require covers depending on the length of a product. 3: Pass height of 350 mm is available as an option. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: In an environment where water or oil regularly splashes the equipment, the maximum is 20 kg. 7: Can decrease if the conveyor is exposed to water or oil. 8: Allowable power fluctuation range is ±10%. 9: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 10: Installing the air-conditioner option changes the displayed power consumption. 11: The air-conditioner option may be required depending on the operating environment. Note: The noise level of KD7447DW/KD7447DWE does not exceed 70 dB(A). The noise level of KD7447FWE is 72 dB (A).

External Dimensions

690

1114

424

1200

500

700

to 8

00Li

ne h

eigh

ts

49.5 dia.Roller

836Leg spacing

975Leg spacing

80 dia.

350

590Effective detection width

1806

to 1

906

250

Pas

s he

ight

(484

)

(471

)62

0B

elt w

idth

590

410

250

Detection area

Units:mm

KD7447DWKD7447DWE

For Specific Applications Large Products and Cartons

KD74 series 

KD7447DW

For Packaged Products

For Specific ApplicationsK

D74 series

KD

74-h

seriesK

D74

-f seriesD

ualX

620

300

690

463

1153

(471

)(8

00)

1200

Maintenancespace

Maintenancespace

49.5 dia.Roller

700

to 8

00

82580 dia.

250

590

388

1906

to 2

006

(150

0)

Bel

t wid

th

Line

hei

ghts

Leg spacing 1013

Leg spacing

Pas

s he

ight

Effective detection width

500

590

410

250

Detection area

Units:mm

KD7447FWE

DualXKD74 series 

KD7447DW/DWE/FWE Maximum width Maximum height

Detection area: 590 mm × 250 mm

Page 14: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

14

■ Specifications

Model KD7416AM KD7416ACMDetection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm longX-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 365 mm, maximum height 150 mm Maximum width 365 mm, maximum height 50 mmBelt width 420 mmPreset memory Maximum 100

Belt speed 4

Maximum product weight 55 to 40 m/min, maximum 5 kg 5 to 50 m/min, maximum 3 kg5 to 35 m/min, maximum 10 kg (optional) 5 to 35 m/min, maximum 8 kg (optional)

Power requirements 6, 7 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.6 kVA, rush current 80 A (typ.) (5 ms or less)Mass 335 kg 355 kgEnvironmental conditions Temperature: 0º to 35ºC, relative humidity: 30% to 85%, non-condensingProtection class 8 IP69K (with all protection covers closed)Exterior Stainless steel (SUS304)Cooling system Air conditioner (standard equipped)

1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Excluding air-conditioner ventilation hole. Note: The noise level of x-ray inspection systems is 82 dB(A).

External Dimensions

(610)

(420)

(410) 270

(365

)

(380

)42

0B

elt w

idth

60 dia.450

Leg spacing 755

Leg spacing

365Effective detection width

(590

)

(550

to 6

10)15

40 to

160

014

30

1380

480

900

540

360

720

to 7

80Li

ne h

eigh

ts

33.5 dia.Roller

33.5 dia.Roller

800

500

150

Pas

s he

ight

(90º

)

(200

º)

(105º)

(140º)

Air conditioner

150

365

255

Detection area

Units:mm

KD7416AM

(610)

(185)

(170)

(365

)

(380

)42

0B

elt w

idth

60 dia.450

Leg spacing

(410) 270

755Leg spacing

365Effective detection width

(590

)

610

to 7

00

780

to 8

70 1600

to 1

690

1430

1380

480

900

540

360

720

to 7

80Li

ne h

eigh

ts

33.5 dia.Roller

48 dia.Roller

5001270

1360 to 13751340 to 1355

30 to

50

Pas

s he

ight

(90°

)

120°

(200

º)

(105º)

(125º)

10 to 15º

Air conditioner

Detection area

50

330

365

Units:mm

KD7416ACM

For Specific Applications Sanitary Design

KD74 series 

KD7416ACMAir conditioner is equipped as standard.

For Specific ApplicationsK

D74 series

KD

74-h

seriesK

D74

-f seriesD

ualX

KD7416AM Maximum width Maximum height

Detection area: 365 mm × 150 mm

KD7416ACM Maximum width Maximum height

Detection area: 365 mm × 50 mm

For Packaged Products

For Unpackaged Fresh Meat, Poultry and Fish

KD7416ADM (1000-mm long) and KD7416ABM (Hopper loading system) are also available. Contact our sales representatives for details.

Page 15: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

15

For Specific Applications Sanitary Design

KD74 series 

For Specific ApplicationsK

D74 series

KD

74-h

seriesK

D74

-f seriesD

ualX

■ Specifications

Model KD7478AWH KD7478BWHDetection sensitivity 1 Fe sphere and SUS sphere 0.4 mm dia.X-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 W Tube voltage 25 to 80 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)Detection area 2, 3 Maximum width 120 mm, maximum height 350 mmBelt width 120 mmPreset memory Maximum 100

Belt speed 4

Maximum product weight 5 5 to 60 m/min, maximum 5 kg

Power requirements 6, 7, 8 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)Mass 310 kg 315 kgEnvironmental conditions 9 Temperature: 0ºC to 35ºC (0ºC to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensingProtection class Conveyor IP66, other parts IP40, tool free belt removalExterior Stainless steel (SUS304)

1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The product size should fall below the detection area. 3: The entrance and exit may require covers depending on the length of a product. 4: Variable depending on Product No. 5: Sum total of product weight on the conveyor. 6: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 7: Allowable power fluctuation range is ±10%. 8: Installing the air-conditioner option changes the displayed power consumption. 9: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems does not exceed 70 dB(A).

External Dimensions

55

905

520

385

1455

1400

500

120

Bel

t wid

th

350

Pass

hei

ght

712Leg spacing

382

150Effective detection width

60 dia.

450Leg spacing

700

to 8

00Li

ne h

eigh

ts15

05 to

160

5

33.5 dia.Roller

IN OUT

150

307

237

Detection area

Units:mm

KD7478AWHKD7478BWH

Flow direction can be changed.

For Specific Applications Tall Products

KD74 series 

KD7478AWH

For Packaged Products

KD7478AWH/BWH Maximum width Maximum height

Detection area: 120 mm × 350 mm

Note: Not usable for glass containers.

Page 16: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

16

■ Specifications

Model KD7483AFWHDetection sensitivity 1 Fe sphere and SUS sphere 0.6 mm dia. (when only water is conveyed)X-ray output Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 WSafety X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with touch buzzer)

Product sizeProduct: solids in fluid

12 mm or smaller (less than 1/3 of the minimum height of the inspection section)

Transfer pipe dimension 3-inch (76.2 mm) dia.Inspection section pass height 35 mm (fixed)Position change at sensitivity adjustment Main unit position change (pipe position fixed)Preset memory Maximum 100Processing capacity (flow) 11.0 kℓ/hPower requirements 2, 3 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 1.6 kVA, rush current 80 A (typ.) (5 ms or less)Mass 340 kgEnvironmental conditions Temperature: 0ºC to 40ºC, relative humidity: 30% to 85%, non-condensingProtection class Product transfer pipe IP66, other parts IP40Exterior Stainless steel (SUS304)Cooling system Air conditioner (standard equipped)

1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: Allowable power fluctuation range is ±10%. 3: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. Note: The noise level of x-ray inspection systems is 71 dB(A).

External Dimensions

(170º)

(170º)

880

to 9

80Li

ne h

eigh

ts

990

to 1

090

Join

t hei

ghts

770

to 8

70Jo

int h

eigh

ts

560Leg spacing

1280Leg spacing

Clamp Union Fittings 3.0 S

80 dia.

165

124

226100

1400

1074

165

890

379 901

(250

)

(470

)

(80º

)

130Stroke width

350Stroke width

Air conditioner

110

1480

to 1

580

Units:mm

KD7483AFWH

For Specific Applications Pipe type

KD74 series 

KD7483AFWH Solids in fluid

Product size: 12 mm (Less than 1/3 of the minimum height of the inspection section)

KD7483AFWHAir conditioner is equipped as standard.

For Pumped Products

KD

74 seriesK

D74

-h series

KD

74-f series

For Specific ApplicationsD

ualX

Page 17: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

17

X-ray Inspection System

160

Bel

t wid

th40

5

700

to 8

00Li

ne h

eigh

ts

1310

to 1

410

1140

to 1

240

1580

to 1

680

Tower light

290

695

475

260

460

550

Leg spacing

520

Leg spacing

Detection area

100

30

For Specific Applications Pipe type

KD74 series 

For Specific ApplicationsK

D74 series

KD

74-h

seriesK

D74

-f seriesD

ualX

■ Specifications

Model KD7490LYNApplication size 1 Width: maximum 100 mm, Height: maximum 30 mm, Length: maximum 230 mmSafety X-ray leakage: Max 1μSv/h or less, Prevention of x-ray leakage by safety devicesDisplay 15-inch color TFT LCD (unified image monitoring screen and operation screen)Operation method Touch panel (with buzzer)Preset memory Maximum 100

Belt speed 2

Maximum product weight 3 10 to 40 m/min, Maximum 0.5 kg

Power requirement 4 100 to 120 Vac or 200 to 240 Vac, single phase, 50/60 Hz, 300 VAMass 160 kgEnvironmental conditions Temperature: 10ºC to 30ºC, relative humidity: 30% to 85%, air pressure: 700 to 1060 hPa, non-condensingProtection class IP30Exterior Stainless steel (SUS304)

1: Width of 160 mm is available as an option. 2: Variable depending on Product No. 3: Sum total of product weight on the conveyor. 4: Allowable power fluctuation range is ±10%. Note: Noise level does not exceed 70 dB(A).

External Dimensions

Units:mm

KD7490LYN

For Specific Applications Pharmaceutical

KD74 series 

KD7490LYN

For Pharmaceutical Products

KD7490LYN Maximum width Maximum height

Detection area: 100 mm × 30 mm

Safety management

It is your responsibility to check and ensure that you comply with all applicable laws and regulations of your country or region regarding the effect of x-ray exposure on pharmaceutical products. Anritsu conducted a research with the Nagoya City University about the effect of x-rays on the pharmaceutical quality of drug tablets and found that exposure to x-rays did not affect pharmaceutical quality of the drug content.

We exposed comercially available non-steroidal anti-inflammatory drugs (acetaminophen, loxoprofen and mefenamic acid) to x-rays of various doses from 0.34 mGy to 300 Gy, and evaluated the quality of the tablets using pharmaceutical tests. We found the samples exposed to x-rays exhibited almost the same profile in the tests as control samples (0 Gy). We also investigated the influences of heat and humidity on drug tablets after x-ray exposure, and confirmed that the combination of x-ray exposure with accelerated temperature and humidity tests (40ºC, relative humidity 75%) also did not affect the phermaceutical quality. For more details, refer to the full report at http://informahealthcare.com/ddi

Page 18: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

18

X-ray Inspection System

Anritsu believes customer safety is of utmost importance.

Anritsu safety mechanism

Safety management

Safety of inspected products

Emergency stop switchCuts power to x-ray and drive circuits, stops the conveyor and x-ray radiation.

X-ray irradiation displayThe lamp is lit during x-ray radiation.

Leakage prevention curtainPrevents x-ray leakage. For unpackaged or bulk products, the standard lead impregnated curtains are replaced with SUS covers - preventing direct food contact with the curtains.

Hand insertion sensorInterrupting the sensor for a certain period of time stops x-ray radiation.

X-ray ON/OFF keyTurning the key to OFF stops x-ray radiation completely.

X-ray shield cover open/close sensorOpening the cover stops x-ray radiation.

X-ray shield coverOpened/Closed using x-ray Irradiation ON/OFF Key. Opening the cover stops x-ray radiation due to the x-ray Shield Cover Open/Close Sensor.

X-ray Inspection System has been designed to fully satisfy the safe operation. However, to ensure even higher safety, use the safety procedures outlined below.

1

3

Periodic measurement and recording of x-ray leakage data

Additional safety measuresCovers may need to be mounted on upstream and downstream conveyors instead of the shield curtains, depending on the shape, weight, and package of products.

2

4

Management of operator working hours

No disassembly or modificationNEVER modify or disassemble the main unit, covers, x-ray leakage prevention curtains, safety covers, safety interlocks, etc., otherwise the x-ray leak-proof design may no longer be functional.

WHO concluded in 1980 that the “irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard and introduces no special nutritional or microbiological problems.”The maximum dose of x-ray irradiation to the products to be inspected by our x-ray inspection systems is 0.002 Gy, which is much lower than the value described above. Even if a product stops inside, the x-ray dose is always kept to 0.1 Gy or less.

Note: Follow the local laws and regulations regarding the installation and use of the x-ray inspection systems.

Safety in design

Page 19: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

19

Note

Page 20: X-ray Inspection System - dl.cdn-anritsu.com · X-ray Inspection System 6 Specifications Model KD7405ABWH KD7416ABWH Detection sensitivity 1 Fe sphere and SUS sphere 0.3 mm dia.,

X-ray Inspection System

KD74

KD74-h

KD74-f

DualX

For Specific Applications

May 2017

2017-5 10 (ddc) Printed in JapanCAT. NO. K3175-E-1

2014