Features:
• engine• Leroy Somer Alternator, Class H• Genset Canopy IP44 protection, Control panelIP56 protection• Control module PLC-920• Breaker: ABB 3200A• Speed governor: governor• Excitation system: Brushless• A.V.R model: R449• 50℃ radiator• Fire extinguisher• Oil pump on the engine• ATS receptacle• Lockable battery isolator switch• Vibration isolators between the engine/Alternatorand base frame• Integrated wiring design• High water temperature protection• Steel base frame with forkslots• Big daily fuel tank
Output Ratings
Generator Set
Model
Prime Power Standby Power
kVA kW kVA kW
WPS1750S 1750 1400 1925 1540
Ratings at 0.8 power factor
Dimensions and Weights
Model L × W × H-mmDry Weight-
kg
WPS1750S 12192× 2438× 2896 18950
Ratings and Performance Data
Engine Brand
Engine Model
Alternator Brand Leroy Somer
Alternator Model LSA52.3S5
Control System PLC-920
Circuit Breaker Type ABB 3200A
Frequency / Phase 50Hz/3Phase
Engine Speed((RPM))
Fuel Tank Capacity((L)) 2500
Fuel Consumption((L/h))(100%load)
Model Type Containerized
Standard Package Plastic
Noise Level@7m((dBA)) 92.6
Generator set Manufacture PowerLink
Oil Consumption((L/h))
Volatage((V)) 380/400/415/440
Silencer Noise
Reduction((dBA))
Notes:*Prime Power Continuous duty operation, under variable load 24/24h-10%over load permissible 1 hour/12 hours; **Standby Power Standby duty, operation under variable load, without overload; Standard Reference Conditions Note: Standard reference conditions25°C (77°F) Air Inlet Temp, 100m(328 ft) A.S.L. 30% relative humidity.
WPS1750S/ 10000211901750kVA, Containerized, LSA52.3S5, 3phase, AutoGen
1/7www.multiphase-power.com
Engine Model:
Engine Technical Data
Engine Model
Engine Brand
Number of Cylinders
Cylinders Arrangement
Bore/Stroke((mm)) /
Speed((RPM))
Displacement((L))
Compression Ratio
Air Intake system
Cooling Method
Coolant Capacity((L))
Prime Power((kWm))
Standby Power((kWm))
Governing Type
Back Pressure((mmhg))
Battery((V))
Exhaust and silencer System
Exhaust Air Flow((m³/hr))
Exhaust Air Temp.((°C))
Maximum Allowable Back
Pressure((mmhg))
NOx((mg/Nm³))
Silencer Quantity
Silencer Type
Cooling System
Radiator 50
Coolant Capacity((L))
Coolant Change Time((Year/h))
Coolant Intake Temp.((°C))
Coolant Output Temp.((°C))
Designed to operate in ambient conditions up to 50°C (122°F).
Fuel System
Fuel Tank steel
Fuel Tank Capacity((L)) 2500
Fuel tank type Double-layer
Recommended Fuel Type 0# or ASTM2
Injection System Direct injection
Fuel Consumption:
WPS1750S 100%Load
75%Load
50%Load
25%Load
L/h
(Based on diesel fuel with a specific gravity of 0.85 and conforming toBS2869,Class A2)
Air Intake system
Air Filter Type
Intake Air Flow((m³/h))
Intake System
Intake Air Temp.((°C))
Lubrication System
Lube oil label
Maximum Oil Temp.((°C))
Oil capacity((L))
Conditions
Altitude((m))
Ambient Temp.((°C)) -5℃-50℃Barometric Pressure((kpa)) 100
Relative Humidity <80%
WPS1750S/ 10000211901750kVA, Containerized, LSA52.3S5, 3phase, AutoGen
2/7www.multiphase-power.com
Alternator Model:LSA52.3S5
Alternator Physical Data
AVR Model R449
Alternator Brand Leroy Somer
Alternator Model LSA52.3S5
Excitation System Brushless
Housing Protection IP23
Power Factor 0.8
Rated Stator Temp. rise((℃)) 125
Rotor Insulation Class H
Voltage Fluctuation(no load to
full load)±0.5%
Winding Pitch 2/3
Wiring Connection Series Star
Alternator Operating Data
Overspeed((rpm)) 2250
Voltage Reguation(Steady state) ± 1.0 %
THF(BS EN60034-1) <50
TIF(NEMA MG 1-22) <2%
Air Flow((m³/s))-Alternator
50Hz/60Hz2.69
Altitude-Alternator((m)) 1000
Performance Data
Time constants/400V((Ms))
T’d 0.149s
T’’d 0.02s
T’do 2.46s
Ta 0.02s
Short-circuit current (3 IN / 10 s) 300 % (3 IN) : 10s
SHORT CIRCUIT RATIO 1/Xd
Reactances((Per Unit))
Xd
X'd
X"d
Voltage Technical Data
VoltagePrime Standby
kVA kW kVA kW
380V@50Hz 1860 1488 2046 1636
400V@50Hz 1860 1488 2046 1636
415V@50Hz 1860 1488 2046 1636
415V@60Hz 1933 1546.4 2126 1701
440V@60Hz 2042 1633.6 2246 1796
480V@60Hz 2230 1784 2453 1962
WPS1750S/ 10000211901750kVA, Containerized, LSA52.3S5, 3phase, AutoGen
3/7www.multiphase-power.com
Overall Dimensions
WPS1750S/ 10000211901750kVA, Containerized, LSA52.3S5, 3phase, AutoGen
4/7www.multiphase-power.com
Control System
WPS1750S/ 10000211901750kVA, Containerized, LSA52.3S5, 3phase, AutoGen
5/7www.multiphase-power.com
Product Standard Configuration
Alternator
AlternatorA.V.R
Control System
PLC-7420 ControlSystemObservation Window andControl DoorAir BreakerExternal CableConnectionCable Line Slot
Fuel System
Inbuilt Fuel TankWater Separator FuelPrefilterFuel Tank DrainFuel Level Control PanelDisplayOil Pan
Lubrication System
Lube Oil Drain PumpLube Oil TemperatureSensor
Cooling System
50℃ RadiatorExternal Water InletProtection Mesh for Fanand Revolving Parts
Air intake system
Air FilterIntake Air Filter ScreenIntake Air Silencer
Exhaust system
Industrial SilencerHeat InsulationProtective SleeveExhaust Outlet withFlexibleHeat Hand Protection
Shipment and Installation
Forklift Lifting PointsLifting LugDragging HoleSide Collision AvoidanceDesignBase Mounting Hole
Safety protection devices
Earth ProtectionOil PressureWarning/DowntimeOil LevelWarning/DowntimeWater TemperatureWarning/DowntimeWater LevelWarning/DowntimeSpeedWarning/DowntimeAnti-lightning InstallationSecure TransportationExternal Emergency StopExtinguisherExplosion-proof LampNo-skid Floor
Technical documents
Genset OperationManualEngine Operation ManualAlternator OperationManualGenset Test ReportGanset Circuit DiagramGenset InstallationDrawingsMaintenance ManualMaintenance Records
Engine
Water-Cooled EngineBatteryBattery SwitchDraining Oil PumpStandard Air FilterElectronic GovernorRadiator Core GuardAir Filter withReplaceable CartridgeBattery Charger
Machine Body
LadderSilence Cotton InsideCanopyCentral Lifting PointSimple BaseplateForklifts
- - -
WPS1750S/ 10000211901750kVA, Containerized, LSA52.3S5, 3phase, AutoGen
6/7www.multiphase-power.com
Optional Configuration
Alternator
PMGAnti-condensationHeaterWinding TemperatureMeasurement
Control System
PLC-920 Control SystemPLC-8610 ControlSystemLeak Protection Device
Fuel System
External Fuel FillingDeviceFuel Level GaugeFuel Three-Way ValueAuto Refilling DieselSystem
Lubrication System
Auto Refilling Oil SystemLube Oil Preheater
Cooling System
45℃ Radiator40℃ RadiatorSupplied with Coolant
Air intake system
Forced Air Inlet SystemIntake Air PreheatingSystem
Exhaust system
Residential Silencer
Voltage
415/240V400/230V380/220V220-240V-SINGLEPHASE220/127V480/277V440/254V
Wheel Braking System
Trailer-Roadside TypeTrailer-Off-Road TypeTrailer SuspensionSystem
Safety protection devices
RCD ProtectionImbalanced Three-phaseWarning/DowntimeSpark-extinguishingDeviceOpen the Door ShutdownProtectionRest Area
High-tech configuration
Remote ControlRemote Communicationand DiagnosisRemote MonitorAuto Start-Stop SystemAlert MessageNotificationMaintenance CycleNotification
Optional configuration
Three-way CatalyticConverterEngine Triple PaintedGenset ParallelInstallationExternal Fuel TankSECC Base FrameStainless Steel ExhaustSystem4 Poles Circuit BreakerATSQuick ConnectorFuel Leaking Protection
Technical documents
Genset Parts ManualEngine Parts ManualGenset Tools Package
Engine
Jacket Water Heater220/240VOil HeaterBlock HeaterHeavy Duty Air Filter
-
WPS1750S/ 10000211901750kVA, Containerized, LSA52.3S5, 3phase, AutoGen
7/7www.multiphase-power.com