WOOD FRAME TYPE CONSTRUCTION

2
WOOD FRAME TYPE CONSTRUCTION Building & Fire Safety Division – Yakima County Public Services UNHEATED SCALE: 1/2" = 1'-0" (EXAMPLE ONLY) PROVIDE COPY OF TRUSS SHEET FROM TRUSS MANUFACTURER ____ " O.C. _____ _____ PROVIDE MIN. 22" X 30" ATTIC ACCESS IF ANY PORTION OF ATTIC IS GREATER THAN 30" IN HEIGHT SPECIFY HOW ATTIC VENTILATION IF USING MANUFACTURED TRUSSES INSULATION IF HEATED SPECIFY INSULATION WALL SECTION - MONOLITHIC SLAB Monolithic Footing @ Slab (Unheated) Roofing: _______________________ Sheathing: ___________________ Roof pitch TYPICAL WALL SECTION Headers: _____”x_____” Grade: _____________ Species: ____________ Wall Sheathing: ___________________ Studs: 2”x__________” @ ______” on center Grade: _____________ Species: ____________ Anchor Bolts: ½” x 10” J-bolt @ (maximum) 6’ on center, (1) within 12” to ends of each sill plate. SILL PLATE 2”x______” (pressure treated) 6” Minimum wood/earth separation FOOTINGS: Bottom of footing 12” below finished grade Minimum width 12” Maximum wall height (stud length) 10’ or engineering may be required OFFICE USE ONLY: BLD USE OF BUILDING: ______________________________________ Fill in ____ below as to how you propose to build your structure. Select footing. Submit 2 sets of plans ROOF FRAMING: Rafter: 2”x_____” @ ____” on center Grade: _____________ Specie: ____________ Ridge board: (Minimum 2” deeper than rafter) 2”x_____ Ceiling Joist or Collar Tie: 2”x_____” @ ____” on center Grade: _____________ Species: ____________ OR Manufactured Truss @ _______” on center Provide 2 sets of truss sheets and truss layout. (Engineer stamp is required on truss sheets) Wall Height: Stemwall & Footings Unheated Monolithic Footing @ Slab *Heated Structure [*Bottom of footings must be 24” below finished grade] Finished grade Rigid insulation Minimum R-10 Stemwall & Footings *Heated Structure [*Bottom of footings must be 24” below finished grade] Solid Blocking 2” x _______” 6” Minimum Minimum R – 10 Rigid insulation 6” Minimum Concrete slab (4” Minimum) 6” 24” 6” 12” 24” 6” 12” 12” 12” 12” 12 612”

description

civil

Transcript of WOOD FRAME TYPE CONSTRUCTION

Page 1: WOOD FRAME TYPE CONSTRUCTION

G:DSCFORMSPERMITSERVICESWOODFRAMEACCESSORY 1

WOOD FRAME TYPE CONSTRUCTION

Building & Fire Safety Division – Yakima County Public Services

UNHEATED

ROOFING:

4

12

SHEATHING:

SCALE: 1/2" = 1'-0"

HEATEDSCALE: 1/2" = 1'-0"

UNHEATED SCALE: 1/2" = 1'-0"

(TYP.)

WALL SHEATH:

HEADERS:

2 X ___ STUDS @ ____" O.C.

GRADE:

SPECIE:

HEATED SCALE: 1/2" = 1'-0"

FIN. GRADE

DETACHED GARAGE(EXAMPLE ONLY)

ROOF FRAMING:

PROVIDE COPY OF TRUSS SHEETFROM TRUSS MANUFACTURER

2 X ___ RAFTERS @ ____ " O.C.SPECIE _____, GRADE _____

SPECIE _____, GRADE _____2 X ___ CEILING JOISTS @ ____ " O.C.

GRADE:

SPECIE:

2 X __ P.T. SILL PLATE

1/2" X 10" ANCHOR BOLT

WITHIN 12" OF ENDS OFEACH PIECE OF SILL

IF INTERIOR IS FINISHED

NOTES:

1.SPECIFY FINISH MATERIALPROVIDE MIN. 22" X 30" ATTICACCESS IF ANY PORTION OF ATTICIS GREATER THAN 30" IN HEIGHT

WILL BE PROVIDEDSPECIFY HOW ATTIC VENTILATION

**

*

IF USING MANUFACTURED TRUSSES

OR SPECIFY:

6" MIN.

FIN. GRADE

6" MIN.

FIN. GRADE

6" MIN.

FIN. GRADE

6" MIN.

2 X __ SOLIDBLOCKING

SLAB THICKNESS ___"

R-10 RIGIDINSULATION

R-10 RIGIDINSULATION

IF HEATED SPECIFY INSULATION2.MATERIAL AND R-VALUE

6" MIN.

6" MIN.

O@ 6'-0" O.C. MAX. W/ (1)

MONOLITHIC SLAB

STEMWALL FOOTING

STEMWALL FOOTINGWALL SECTION - MONOLITHIC SLAB

Monolithic Footing @ Slab (Unheated)

Roofing: _______________________

Sheathing: ___________________

Roof pitch

TYPICAL WALL SECTION Headers: _____”x_____”

Grade: _____________ Species: ____________

Wall Sheathing: ___________________

Studs: 2”x__________” @ ______” on center Grade: _____________ Species: ____________

Anchor Bolts: ½” x 10” J-bolt @ (maximum) 6’ on center, (1) within 12” to ends of each sill plate.

SILL PLATE 2”x______” (pressure treated)

6” Minimum wood/earth separation

FOOTINGS: Bottom of footing 12” below finished grade Minimum width 12”

Maximum wall height (stud length) 10’ or engineering may be required

OFFICE USE ONLY:

BLD USE OF BUILDING: ______________________________________

Fill in ____ below as to how you propose to build your structure.

Select footing. Submit 2 sets of plans

ROOF FRAMING: Rafter:

2”x_____” @ ____” on center Grade: _____________ Specie: ____________

Ridge board: (Minimum 2” deeper than rafter) 2”x_____

Ceiling Joist or Collar Tie: 2”x_____” @ ____” on center Grade: _____________ Species: ____________

OR Manufactured Truss

@ _______” on center Provide 2 sets of truss sheets and truss layout. (Engineer stamp is required on truss sheets) Wall Height: Minimum 4” concrete slab

Stemwall & Footings Unheated

Monolithic Footing @ Slab *Heated Structure

[*Bottom of footings must be 24” below finished grade]

Finished grade

Rigid insulation Minimum R-10

Stemwall & Footings *Heated Structure

[*Bottom of footings must be 24” below finished grade]

Solid Blocking 2” x _______”

6” Minimum

Minimum R – 10 Rigid insulation

6” Minimum

Concrete slab (4” Minimum)

6”

24”

6”

12”

24”

6”

12”

12”

12”

12”

12

6”

12”

Page 2: WOOD FRAME TYPE CONSTRUCTION

4’ x

4’ w

ind

ow

(sl

ider

)

Hea

der

__

___

____

__

1.

Use

of

Stru

ctu

re. _

___

____

____

____

____

____

____

____

____

____

___

2.

Dim

ensi

on

flo

or

pla

n: S

pec

ify

ove

rall

size

an

d t

ota

l sq

uar

e fo

ota

ge o

f st

ruct

ure

.

3.

Pro

vid

e ri

dge

lin

e o

r d

irec

tio

n o

f ra

fter

/ t

russ

to

ind

icat

e b

ear

ing

wal

l.

4.

Loca

te e

xter

ior

op

enin

gs (

do

ors

an

d w

ind

ow

s).

a.

Spec

ify

size

of

op

enin

gs (

wid

th a

nd

hei

ght)

.

b.

Dim

ensi

on

s b

etw

een

all

op

enin

gs a

nd

co

rner

s o

f st

ruct

ure

.

5.

Spec

ify

all h

ead

ers

ove

r o

pen

ings

: Si

ze, g

rad

e, a

nd

sp

eci

e o

f lu

mb

er.

6.

Will

th

e st

ruct

ure

be

hea

ted

?

a.

If s

o, p

rovi

de

typ

e o

f eq

uip

me

nt

and

loca

tio

n. (

Sep

arat

e m

ech

anic

al p

erm

it is

req

uir

ed).

3’ x

6’8

” m

an d

oo

r H

ead

er _

___

___

_

Ove

rhea

d D

oo

r 1

0’ x

8’

Ove

rhea

d D

oo

r 1

0’ x

8’

10

’ 2

’ 4

’ 1

0’

10

3’ 3’

18

16

’ 4

’ 1

6’

36

24

This

is a

flo

or

pla

n e

xam

ple

o

f a

wo

od

fra

me

stru

ctu

re.

Yo

u

mu

st

sub

mit

yo

ur

ow

n

dra

win

g o

f yo

ur

ove

rall

flo

or

pla

n w

ith

det

ails

as

sho

wn

in

th

e ex

amp

le t

o t

he

righ

t.

The

cro

ss

wal

l se

ctio

n

det

ail

may

be

fille

d i

n a

nd

su

bm

itte

d

for

pla

n

revi

ew

pro

vid

ing

the

fram

ed

wal

l h

eigh

t (s

tud

le

ngt

h)

is 1

0’ o

r le

ss.

On

yo

ur

pla

ns,

ple

ase

ind

icat

e if

th

e st

ruct

ure

will

be

:

Hea

ted

No

n-h

eate

d

Sele

ct

wh

ich

ty

pe

of

foo

tin

g yo

u w

ill u

se,

Mo

no

lith

ic p

ou

r

Foo

tin

g/fo

un

dat

ion

36

” x

36

Co

ncr

ete

Lan

din

g

Alt

ern

ate

bra

ce p

anel

s ar

e re

qu

ired

fo

r w

alls

le

ss t

han

4’ i

n w

idth

WIN

DO

WS:

P

leas

e sp

eci

fy if

win

do

ws

are:

Si

ngl

e h

un

g, S

lidin

g, o

r Fi

xed

. Sa

fety

gla

zed

.

Hea

der

__

___

___

Man

ufa

ctu

red

tr

uss

@ 2

’ o.c

.