Wireless Control Module - OSRAM SYLVANIA · The Wireless Control Module ... PoE Switch ENCELIUM...

3
Key Features & Benefits Control module for all of the following: – 0-10V dimmable luminaires – DALI ballasts – Occupancy sensors ENCELIUM GreenBus II ® connection available for GreenBus II devices Connects 0-10V dimmable luminaires to network for: – Customizing lighting scenes for tailored experiences/tasks – Adjusting light levels to respond to variable lighting requirements The Wireless Control Module (WCM) is a key component of the ENCELIUM Energy Management System (EMS). This device allows luminaires and occupancy sensors to communicate via a mesh network based on ZigBee ® standards. Individually addressable, the WCM enables each ballast or LED driver to be independently controlled and configured to best meet the needs of the facility. The WCM switches a fixture ON or OFF via a relay contained in the module as well as delivers a low voltage dimming signal to any 0-10V dimming ballast/driver. A WCM can be connected to LED drivers without isolation between the dimming section and the electrical output for added flexibility in LED driver options. OSRAM offers a special Damp-Rated (DR) WCM for installations subject to moderate degrees of moisture. The WCM is compatible to ENCELIUM hardwired products via the GreenBus II port on the device. This enhances the flexibility of the system to include phase-cut dimming, area lighting control and relay panel control. Wireless Control Module ENCELIUM ® Energy Management System – Hardware www.encelium.com LMS103R1 7-15 ENCELIUM Wireless and ENCELIUM GreenBus II ® Communication Networks ENCELIUM Wireless Energy Management System Architecture System Architecture This illustration shows how each component is easily integrated into the ENCELIUM Wireless Energy Management System (EMS). The ENCELIUM Wireless system commu- nicates via a mesh network based on ZigBee standards. The WCM is powered by incom- ing line voltage. Each WCM, sensor, and wallstation uses a wireless mesh network to relay data back to the Wireless Manager (WM). WMs typically control individual floors and are linked via an Ethernet Network back to the SSU. Internet or LAN connection allow floor plan based control software via Polaris 3D ® to be operated anywhere on the network. For reference, the component shown on this data sheet is highlighted. WCM Light Fixture Wireless Wall Station PoE Switch ENCELIUM Ethernet Network Low-Voltage Sensor Polaris 3D ® /PCS/PCW FLOOR 1 FLOOR 2 Light Fixture SSU WCM Router WM WM Polaris 3D ® Tenant Ethernet Network SIM GreenBus II ® Line Power & Dimming to switch leg AC Phase Cut Dimming Fixtures WCM WCM Relay Panel PCDM ALC Wireless Sensor Line Power U L US C

Transcript of Wireless Control Module - OSRAM SYLVANIA · The Wireless Control Module ... PoE Switch ENCELIUM...

Page 1: Wireless Control Module - OSRAM SYLVANIA · The Wireless Control Module ... PoE Switch ENCELIUM Ethernet Network Low-Voltage ... 45583 EN-WCM-ZB ZigBee Wireless Specifications

Key Features & Benefits

— Control module for all of the following: – 0-10V dimmable luminaires – DALI ballasts – Occupancy sensors

— ENCELIUM GreenBus II® connection available for GreenBus II devices

— Connects 0-10V dimmable luminaires to network for: – Customizing lighting scenes for tailored experiences/tasks – Adjusting light levels to respond to variable lighting requirements

The Wireless Control Module (WCM) is a key component of the ENCELIUM Energy Management System (EMS). This device allows luminaires and occupancy sensors to communicate via a mesh network based on ZigBee® standards. Individually addressable, the WCM enables each ballast or LED driver to be independently controlled and configured to best meet the needs of the facility.

The WCM switches a fixture ON or OFF via a relay contained in the module as well as delivers a low voltage dimming signal to any 0-10V dimming ballast/driver. A WCM can be connected to LED drivers without isolation between the dimming section and the electrical output for added flexibility in LED driver options.

OSRAM offers a special Damp-Rated (DR) WCM for installations subject to moderate degrees of moisture.

The WCM is compatible to ENCELIUM hardwired products via the GreenBus II port on the device. This enhances the flexibility of the system to include phase-cut dimming, area lighting control and relay panel control.

Wireless Control ModuleENCELIUM® Energy Management System – Hardware

www.encelium.com

LMS103R1 7-15

ENCELIUM Wireless and ENCELIUM GreenBus II®

Communication Networks

ENCELIUM Wireless Energy Management System Architecture

System ArchitectureThis illustration shows how each component is easily integrated into the ENCELIUM Wireless Energy Management System (EMS). The ENCELIUM Wireless system commu-nicates via a mesh network based on ZigBee standards. The WCM is powered by incom-ing line voltage. Each WCM, sensor, and wallstation uses a wireless mesh network to relay data back to the Wireless Manager (WM). WMs typically control individual floors and are linked via an Ethernet Network back to the SSU. Internet or LAN connection allow floor plan based control software via Polaris 3D® to be operated anywhere on the network. For reference, the component shown on this data sheet is highlighted.

WCM

Light Fixture

WirelessWall Station

PoE Switch

ENC

ELIU

M E

ther

net N

etw

ork

Low-VoltageSensor

Polaris 3D®/PCS/PCW

FLO

OR

1FL

OO

R 2 Light Fixture

SSU

WCM

Router

WM

WM

Polaris 3D®

Tenant EthernetNetwork

SIM

GreenBus II®

Line Power & Dimming

to switch leg

Max ambient temperature +50ºCInput: Class 2 Only24V AC, 50/60Hz, min 40VA Relay Panel ModuleEN-RPM-24C-GB2

Install per installation instruction sheet and electrical & building codes. Connect to ENCELIUM GreenBusII System only.CAUTION - To Reduce the Risk of Fire or Electric Shock Do Not Interconnect The Outputs Of Different Class 2 Circuits85-116-DA

Item No 45268

Q1Q2Q3Q4Made in Canada2012201320142015Emergency Lightingand Power EquipmentEnergy Management Equipment Subassembly6NA8

AC Phase Cut

Dimming Fixtures

WCM

WCM

Relay Panel

PCDM

ALC

WirelessSensor

Line Power

UL USC

Page 2: Wireless Control Module - OSRAM SYLVANIA · The Wireless Control Module ... PoE Switch ENCELIUM Ethernet Network Low-Voltage ... 45583 EN-WCM-ZB ZigBee Wireless Specifications

Ordering Information

Item Number Ordering Description Communication Network Modifiers45572 EN-WCM-ZB-DR ZigBee® Wireless - Damp-Rated -DR 45583 EN-WCM-ZB ZigBee Wireless

Specifications

— 3.17" x 1.64" x 1.27" (80.42mm x 41.6mm x 32.31mm)

— Operating temperature range: -40°C (-40°F) to 60°C (140°F)

— Suitable for luminaire or junction box mounting in standard 1/2" knockout (7/8" dia.)

— Absolute Maximum Ratings 300W (all rated voltages have a tolerance of +/-10%): – 4.5A 120-347 Vac Ballast/LED Driver – 5.8A 120-347 Vac Tungsten – 9.0A 120-347 Vac General Purpose

— Single 0-10V dimming output (IEC 60929 Annex E). Capable of sinking 10mA (this is equivalent to 10 typical dimming ballasts/drivers)

— Standard units are for indoor use only or for mounting inside waterproof enclosure

— Damp-rated units may be used in damp locations

— Radio Properties - 2.4 GHz

— Wireless Range: 100' line of sight, 50' through standard walls when WCM is mounted exterior to the luminaire – Range decreases by 50% when mounted inside the luminaire

— Safety approvals: – Energy Management Equipment (UL 916) – Emergency Lighting Equipment (UL 924 cULus Listed) – Heat and Smoke Release for Air-Handling Spaces (UL 2043)

— 0-10V or DALI connectivity

— ENCELIUM GreenBus II connection port for GreenBus II devices

— Complies with the following electromagnetic requirements: – EN 61000-4-2 – EN 61000-4-4 – EN 61000-4-5

— FCC Part 15/ICES-003

Installation Diagram

Dimensions

The mechanical construction allows for simple installation of the WCM to an available 1/2 inch knock-out on the side or on top of a fixture (as shown below). All necessary wiring for the electronic dimming ballast or LED driver is available on the inside.

For some installations, a junction box may be required. It is recommended to securely mount the WCM to the junction box (as shown below) using an available 1/2 inch knock-out and a retainer nut.

WCM

(32.

31m

m)

1.27

0.96

”(2

4.31

mm

)

(31.

31m

m)

1.23

1.64

”(4

1.60

mm

)

3.17”(80.42mm)

Fixture

WCM

J Box MountingFixture Mounting

Page 3: Wireless Control Module - OSRAM SYLVANIA · The Wireless Control Module ... PoE Switch ENCELIUM Ethernet Network Low-Voltage ... 45583 EN-WCM-ZB ZigBee Wireless Specifications

OSRAM is a registered trademark of OSRAM GmbH. ENCELIUM, GreenBus II and Polaris 3D are registered trademarks. ZigBee is a registered trademark of ZigBee Alliance. Specifications subject to change without notice.

Americas Headquarters

OSRAM SYLVANIA Inc.

100 Endicott Street

Danvers, MA 01923 USA

Phone 1-888-531-7571

www.encelium.com

© 2015 OSRAM

Wire Table

Wire Color Wiring to Luminaire Wiring to Low Voltage Sensor Wiring Using GreenBus II Port Only Wire LengthBLACK Line In - Relay Contact Line In - Relay Contact Line In 9.84" (250mm)RED Line Out - Relay Contact Not Used Not Used 9.84" (250mm)WHITE Neutral Neutral (WCM Input Only) Neutral 9.84" (250mm)VIOLET Class 2, Low Voltage, 0-10Vdc, 10mA max. Power Not Used 23.62" (600mm)GREY Class 2, Low Voltage Return/Common Common Not Used 23.62" (600mm)BLUE Not Used Signal Not Used 7.09" (180mm) Note: GreenBus II port can also be used when wiring to a luminaire.

Wiring Diagrams

Power Feed

BLACK

ENIL

LARTUEN

RED

GREY GREY/ -VIOLET VIOLET/ + 0-10V ELECTRONIC

BALLAST/DRIVER

LARTUEN

BLUE BLUE NOT USED

Wiring to Luminaire Wiring to Low Voltage Sensor

Power Feed

BLACK

ENIL

LARTUEN

RED

GREY GREY/ -VIOLET VIOLET/ + POWER

LARTUEN

BLUE BLUE SIGNAL

NOT USED

COMMON

Power Feed

BLACK

LINE

NEUT

RAL

RED

GREY GREY/ -VIOLET VIOLET/ + NOT USED

NOT USEDBLUE BLUE NOT USED

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

BLUE

INP

UT

RED

OU

TPU

T

41

Relays Relays

2

3

1

2

3

Power supply input24V AC, 60Hz, 1.6A (40VA)Class 2 only

Power fail input

GreenBusII . Connect to Energy Management System only.

Manual Toggle Button

TM

blue

red

WRRelays

blackbluered

GERelays

Depress with tool to unlock

1 23 45 67 89 1011 1213 1415 1617 1819 2021 2223 24

4

TMLED Always On -> 24V and GreenBusII PresentLED Single Blink -> Only GreenBusII PresentLED Double Blink -> Only 24 VAC Present

TM

Max ambient temperature +50ºC

Input: Class 2 Only24V AC, 50/60Hz, min 40VA

Relay Panel ModuleEN-RPM-24C-GB2

Install per installation instruction sheet and electrical & building codes. Connect to ENCELIUM

GreenBusII System only.

CAUTION - To Reduce the Risk of Fire or Electric Shock Do Not

Interconnect The Outputs Of Different Class 2 Circuits 85

-116

-DA

Item No 45268

Q1 Q2 Q3 Q4

Made in Canada

2012 2013 2014 2015

Emergency Lightingand Power Equipment

Energy Management Equipment Subassembly

6NA8

or or

PCDM

Relay Panel

ALC WCM

NEUTRAL

Wiring Using GreenBus II Port Only