Client/Single station Server

x xx xx xx xx xx xx xx xx x

Server *7, 8) x *9) xClient xServer *7, 8) x *9) xClient x

OPC Historical Data Access (HDA) V1.20 Server *8, 10) x *9) x

OPC Alarms and Events (A&E) V1.10 Server *8, 10) x *9) x

Server *10) x *9) xClient xServer *10, 11) x *9) xClient *12) x

WinCC version SIMATIC WinCC V7.2

Software

V7.2

Microsoft Windows(32-bit)

Windows 7 SP1 *1)

XP Professional SP3Server 2003 SP2 *2)

Server 2003 R2 SP2 *2)

Server 2008 SP2 *2, 3, 4)

Microsoft Windows(64-bit)

Windows 7 SP1 *1)

Server 2008 R2 SP1 *2, 4)

VirtualizationVMware ESXi 5.0

Windows Server 2008 R2 Hyper-V

Microsoft Internet ExplorerV7.0 xV8.0 xV9.0 x

Virus Scanners

Trend Micro OfficeScan V10.6 *5) xMcAfee VirusScan Enterprise V8.8 x

Symantec Endpoint Protection V12.0 SP1 (Norton Antivirus) x

Remote Software Remote Desktop Connection (RDC) *6) x

OPC

OPC Data Access V2.05a (DA)

OPC Data Access V3.00 (DA)

OPC XML Data Access V1.00

Unified Architecture V1.01

Automation License Manager V5.2 x

WinCC Smart Tools

WinCC Configuration Tool x *13)

WinCC Archive Configuration Tool x *13)

WinCC Cross Reference Assistant xWinCC Communication Configurator xVariables Export/Import xVariable Simulator xDynamic Wizard Editor xDocumentation Viewer x

em3588
Text Box
This entry was updated last time 24th of April 2013. You will find the newest list for download at our Compatibility Tool. http://support.automation.siemens.com/WW/view/en/64847782 Use the upper navigation after starting the Compatibility Tool and click at "Tools" for downloading the lists.
Page 2: WinCC V72 Compatibility List e

s With what are SIMATIC WinCC V7.x, V 6.x and V5.x compatible? Entry-ID: 21927773

Changedate: 29.04.2013

This entry is from the Service2upport portal of Siemens AG,Sector Industry, Industry Automation and Drive Technologies.

The general terms of use (http://www.siemens.com/terms_of_use) apply.Page: 2/2

Client/Single station Server

WinCC version SIMATIC WinCC V7.2

Software

V7.2

*1)*2)*3)

*4)

*5)

*6)*7)*8)

*9)

*10)

*11)*12)*13)

*14)*15)*16)*17)*18)

STEP 7 *14) V5.5 SP2 xV5.5 SP3 x

SIMATIC NET *15, 16) V7.1.6 xV8.2 SP1 x

WinCC Connectivity Pack / Station V7.2 x

WinCC/DataMonitor V7.2 xSIMATIC Information Server

2013 V7.2 x *18)

SIMATIC Process Historian 2013 V7.2 x *17)

WinCC/ODK V7.2 x

V1.5 SP1 Upd2

WinCC/Redundancy V7.2 xWinCC/Server V7.2 x

WinCC/User Archives V7.2 xWinCC/WebNavigator V7.2 x

Note operating system, Entry 8250891.

x

Ultimate / Professional / EnterpriseStandard EditionFor the Windows Server 2008 R2 operating refer to the following link for a downgrade that might be required: http://www.microsoft.com/oem/de/licensing/sblicensing/pages/downgrade_rights.aspx#fbid=6JJWdlSJszu

Access to WinCC systems with RDC is only possible through a console session.OPC DA can also be used in WinCC Demo mode.

Windows Server 2008 Enterprise without Hyper-V and Windows Server 2008 Standard without Hyper-V are not system-tested.With WinCC only the "Corporate Edition" of the Trend Micro OfficeScan virus scanner is released.

SIMATIC Logon

Note operating system, Entry 9859007.SIMATIC NET Softnet-S7 Lean supplied with WinCCReleased only with Windows 2008 R2 SP1 64-bit Standard Edition.

OPC DA, OPC A&E and OPC HDA are also supported by the Connectivity Station. WinCC Demo mode is not possible for Connectivity Station.The WinCC OPC Server can only be used on a WinCC Client with its own project.

The SIMATIC Information Server is not released with Windows XP SP3.

OPC HDA, OPC A&E and OPC XML DA cannot be used in WinCC Demo mode. A WinCC Connectivity Pack license is required.OPC UA DA as client, OPC UA DA as server and OPC UA HDA as server.OPC UA DA as client and OPC UA HDA as server.It is not absolutely necessary to have WinCC installed. In this case you cannot read/write data from/to WinCC. However, MS Excel 2003 / 2007 /2010 must be installed.