WIDE-ANGLE PACKAGED X-RAY TUBE
Transcript of WIDE-ANGLE PACKAGED X-RAY TUBE
WIDE-ANGLE PACKAGED X-RAY TUBE
Ideally suited for end users wanting a plug and play
solution. Our packaged tubes are fully radiation shielded,
high voltage isolated and include a high voltage cable
and a low voltage cable. Our packaging has been
designed to provide maximum thermal properties
enabling continuous operation, without compromise.
The control of the high voltage and the filament current as well
as the design of the cooling system and the radiation
protection are the responsibility of the original equipment
manufacturer (OEM). Careful selection of power supply should
assure that the X-Ray tube will be protected against
overcurrent, overvoltage and lack of cooling. Otherwise the
tube and/or the radiation protection may be damaged and
become a hazard.
When installing the X-ray tube assembly into X-ray equipment
and/or operating X-ray equipment, the responsibility for
radiation protection from the X-ray window is with the user.
Compliance with local regulatory requirements and limit values
must be assured.
SPECIFICATIONS GENERAL
RADIATION PROTECTION
MICRO X-RAY INC, SANTA CRUZ, CA MICROXRAY.COM +1 831 207 4900
Polarity Grounded Cathode
Flange Type (6) 8-32 thread
High Voltage Range 4-60 kV 1
Anode current 1 mA (3 mA maximum) 1
Continuous rating 50 W (higher on request) 1,2
Focal spot 33-50 µm, 100 µm
Filament current, max. 1.7 A
Filament voltage, (nominal) 2.5 V
Inherent filtration 127 µm Be
Target materials Mo, W, Rh, Cr, Ag, Cu, Co
Target Angle 20°
Radiation coverage 40°
Radiation leakage <2 µSv/hr @50mm (60kv, 1mA)
1 Interrelationship between voltage, current and power will affect specs2 Up to 150 W with external cooling module
WIDE-ANGLE PACKAGED X-RAY TUBE
Ideally suited for end users wanting a plug and play
solution. These tubes are fully radiation shielded, high
voltage isolated and include a high voltage cable and low
voltage cable. The bronze packaging provides radiation
shielding as well as excellent thermal properties, enabling
continuous operation, without compromise.
The control of the high voltage and the filament current as well
as the design of the cooling system and the radiation
protection are the responsibility of the original equipment
manufacturer (OEM). Careful selection of power supply should
assure that the X-Ray tube will be protected against
overcurrent, overvoltage and lack of cooling. Otherwise the
tube and/or the radiation protection may be damaged and
become a hazard.
When installing the X-ray tube assembly into X-ray equipment
and/or operating X-ray equipment, the responsibility for
radiation protection from the X-ray window is with the user.
Compliance with local regulatory requirements and limit values
must be assured.
SPECIFICATIONS GENERAL
RADIATION PROTECTION
MICRO X-RAY INC, SANTA CRUZ, CA MICROXRAY.COM +1 831 207 4900
Polarity Grounded Cathode
Flange Type (6) 8-32 thread
High Voltage Range 4-60 kV
Anode current, maximum 3.0mA *
Continuous rating 75 W *
Focal spot from 30 µm up to 1000 µm
Filament current, max. 1.7 A
Filament voltage, (nominal) 2.5 V
Inherent filtration 127 µm Be
Target materials Mo, W, Rh, Cr, Ag, Cu, Co
Target Angle 20°
Radiation coverage 40°
Radiation leakage <2 µSv/hr @50mm (60kv, 1mA)
* Up to 150 W with external cooling module
mA
MAX
MAX