Why BoldPlay ?

30

description

Why BoldPlay ?. Brilliant Design. Intuitive Engineering Innovation + Design = Performance Serious Energy Savings Ideal direct/indirect distribution maximum row spacing Exceptional Ceiling Uniformity Low peak candela angle = close-to-ceiling installation. - PowerPoint PPT Presentation

Transcript of Why BoldPlay ?

Page 1: Why  BoldPlay ?
Page 2: Why  BoldPlay ?
Page 3: Why  BoldPlay ?

Why BoldPlay?

Brilliant Design. Intuitive EngineeringInnovation + Design = Performance

Serious Energy SavingsIdeal direct/indirect distribution maximum row spacing

Exceptional Ceiling UniformityLow peak candela angle = close-to-ceiling installation

Page 4: Why  BoldPlay ?

Fearless Innovation in Architectural LED Lighting

LED Light Guide Technology

MesoOpticsNanotechnology

High performance LED luminaire

Page 5: Why  BoldPlay ?

Truly harnessing the true potential of LED technology

1.67”

9.4”

Page 6: Why  BoldPlay ?

Serious Performance

True D/I performance allows:

o Lower power densities

o Maximum visual comfort

o Wider fixture spacing

o Unparalleled uniformity

o No direct view of light source

Peak candela angle is 112.5° and 3.8:1 Peak-to-zenith.

55° brightness control meets RP1 for intensive spaces.

27.5° peak angle minimizes veiling reflections.

70% up/30% down

Page 7: Why  BoldPlay ?

Applications

Page 8: Why  BoldPlay ?

Light SourceRoom SizeSpacingLight LevelEnergy DensityCeiling UniformityLuminaire Efficacy

LED 4800 lm48’Lx26’Wx10’H12’ o.c.39 fc0.60W/ft2

1.94:1102 lm/W

Design for success.

Page 9: Why  BoldPlay ?

Make a lasting impression.

Light SourceRoom SizeLight LevelEnergy DensityLuminaire Efficacy

LED 4800 lm18’Lx12’Wx9’H23 fc0.43W/ft2

102 lm/W

Page 10: Why  BoldPlay ?

Polished appearance,unrivaled performance.

Light SourceRoom SizeSpacingLight LevelEnergy DensityCeiling UniformityLuminaire Efficacy

LED 3400 lm15’Lx12’Wx9’H7.5’ o.c.34 fc0.72W/ft2

1.06:1 106 lm/W

Page 11: Why  BoldPlay ?

In a class of its own.

Light SourceRoom SizeSpacingLight LevelEnergy DensityCeiling UniformityLuminaire Efficacy

LED 4800 lm40’Lx24’Wx16’H12’ o.c.37 fc0.78W/ft2

1.07:1102 lm/W

Page 12: Why  BoldPlay ?

Adding distinction to extraordinary spaces.

Light SourceRoom SizeSpacingLight LevelEnergy DensityCeiling UniformityLuminaire Efficacy

LED 4800 lm60’Lx10’Wx9’H10’ o.c.20 fc0.47W/ft2

3.81:1102 lm/W

Page 13: Why  BoldPlay ?

Make a bold statement.

Light SourceRoom SizeSpacingLight LevelEnergy DensityLuminaire Efficacy

LED 3400 lm60’Lx32’Wx12’H12’ o.c.37 fc0.60W/ft2

106 lm/W

Page 14: Why  BoldPlay ?

Product options

Page 15: Why  BoldPlay ?

Flexible Distributions

20% Up / 80% Down

100% Down

80% Down Variable Optics Kit

100% Down Variable Optics Kit

Page 16: Why  BoldPlay ?

ComplementaryWall Mount

60% Up / 40% Down

Page 17: Why  BoldPlay ?

Color conscious

Page 18: Why  BoldPlay ?

Application Guide

Lighting power density and illuminance information are average maintained values based on predictive engineering analyses in an open plan area measuring 60'W x 60'L x 9’0"H; with room reflectances of ρc 80/ρw 50/ρf 20; and LLF of 0.85 in all cases. Lumen outputs based on 4ft nominal. Changes to fixture mounting and/or workplane heights affect uniformity and to a lower extent light levels, but have no significant impact on energy performance. Ceiling uniformity values are calculated using a statistical area of exitance values, using as a reference, a plane located between a point on the ceiling above a luminaire's photometric center, and the mid-point between two rows of luminaires. All application results have been calculated using real luminaire photometric test data and OEM published system specifications for Philips Ledalite factory standard components at the time of publication. Modifications to architectural conditions, luminaire components, and calculation parameters will yield different results.

Page 19: Why  BoldPlay ?

Technologies

Page 20: Why  BoldPlay ?

Family of Technologies

Page 21: Why  BoldPlay ?
Page 22: Why  BoldPlay ?
Page 23: Why  BoldPlay ?

Example label. For current U.S. DOE Lighting Facts verified data, please visit ledalite.com/boldplay

Lighting FactsPartners & Products*

Manufacturers 556

Retailers & Distributors 294

Lighting Pros 267

EE Sponsors 88

Products 7,818

*Data correct as of 01.29.2013

Page 24: Why  BoldPlay ?

Fixture photometry has been conducted by a NVLAP accredited testing laboratory in accordance with IESNA LM-79-08. Lumen maintenance of the LEDs used in this fixture has been tested by the LED manufacturer in accordance with IESNA LM-80-08.

Page 25: Why  BoldPlay ?

Lumen maintenance:

• TM-21-11: L85 (6K) >36,000 hours*• L80 > 60,000 hours

*IES TM-21-11 only allows lumen maintenance projections up to 6 times the test duration (in hours) of LM-80-08 measured data.

L80

Page 26: Why  BoldPlay ?

Fixture LEDs Driver

Page 27: Why  BoldPlay ?

Optional Integrated Technologies

Page 28: Why  BoldPlay ?

Solar powered photosensorThe solar powered photosensor harnesses energy from natural light via integrated miniature photovoltaic cells and constantly monitors illumination levels.

Kinetic energy switchKinetic handheld remoteThe wireless and battery-free Airwave wall switch and remote handheld control are powered by the simple motion of pushing the switch; creating just enough kinetic energy to send a wireless signal to the transceiver.

Solar powered occupancy sensorThe solar powered occupancy sensor significantly enhances energy savings by automatically dimming down and then turning off when the space is vacant.

Intelligent TransceiverAs the hub of system intelligence, the Airwave transceiver receives wireless signals from each device and commands the associated light fixtures to turn on, turn off or dim.

Page 29: Why  BoldPlay ?

Energy savings of up to 35%

Free. Response Daylight Harvesting Sensors

Page 30: Why  BoldPlay ?