What’s New in ZWCAD+ 2012 SP1? ZWCAD Technical Support Team.

11
What’s New in ZWCAD+ 2012 SP1? ZWCAD Technical Support Team

Transcript of What’s New in ZWCAD+ 2012 SP1? ZWCAD Technical Support Team.

What’s New in ZWCAD+ 2012 SP1?

ZWCAD Technical Support Team

What’s new in ZWCAD+ SP1?

New features (20+) Enhancement

Bug fixed Stability

What’s new in ZWCAD+ SP1?

New features

• SmartPeek for multiple documents

switching and preview (CTRL+TAB )

• ARCTEXT: Arc-aligned text

What’s new in ZWCAD+ SP1?

New features

• ALIASEDIT: Dialog box for command aliases editing

• APP+ shows partner products

What’s new in ZWCAD+ SP1?

New features

• SPELL for text spell checking

• OVERKILL: cleanup overlapping geometry

What’s new in ZWCAD+ SP1?

New features

• Hatch

Now supports Origin Point

Setting

What’s new in ZWCAD+ SP1?

New features

• Multileader and Mleader style (Command: MLEADER, MLEADEREDIT, MLEADERSTYLE)

• MVSETUP for setting up one or more viewports in layout

• EATTEXT for enhanced attribute extraction

• VSLIDE for viewing slide (.sld) files

• STATUS for viewing current drawing status

• TEXTSCR for opening command window (F2)

• DELDUPL: Delete Duplicate Lines, Circles and Arcs

• LOCKUP & UNLOCK: Lock and unlock drawing with password

• ANGDIV: Create bisector of angle

• JOINL: Join lines or arcs

• ARCCOMP: Generate complementary arc of selected one

• EXSCALE: Extended scale

What’s new in ZWCAD+ SP1?

New featuresEnhancement

• Export: supports WMF file format

• Layer manager: supports to search for layer by initial letter

• Ray: now supports sub-commands including Bisect/Horizontal/Vertical/Angle/Offset

• PEDIT command can be triggered by double click on any polyline object

• Installation:

- Run & activate in win8

- Developer Help

- Localized commands

- Deployment

What’s new in ZWCAD+ SP1?

New featuresBug fixed

• Fixed 76 block issue

• Dealt with more than 300 crash report

Stability

What’s new in ZWCAD+ SP1?

New featuresBug fixed

• 3501/T5863, 3999/T6071: Some objects cannot be exploded

• 3482: Error prompted when starting ZWCAD+ under non-Administrator account

• 3711/T6002: When in REFEDIT mode, objects outside working set can be edited through

Ribbon

• 3045/T5587, 3716/T6008: Multi-line text malposition error

• 2865/T5425: Table object displaying error

• 3411/T5807, 3631/T5978: SELECTIONAREA and SELECTIONAREAOPACITY always

reset themselves to default after restart

• 3766/T6030, 3321/T5743: Error when printing OLE objects

• 1092: Cannot switch plot unit between Inch and Millimeter when ploting