![Page 1: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/1.jpg)
WLSACONVERGENCE SUMMIT
“SMARTPHONE PLATFORM SURVEY-SCALE HEART RATE COLLECTION – A PERFORMANCE EVALUATION IN ETHIOPIA”
JAMES A. J. HEATHERSPH.D., UNIVERSITY OF SYDNEY
![Page 2: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/2.jpg)
Ph.D., University of SydneyJAMES A. J. HEATHERS
“Smartphone Platform Survey-Scale Heart Rate Collection – a Performance Evaluation in Ethiopia”
![Page 3: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/3.jpg)
3
WHAT IS HRV?
![Page 4: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/4.jpg)
4
PROBLEMS WITH HRV
![Page 5: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/5.jpg)
5
PROBLEMS WITH HRV
HRV NOW:
• POORLY CONTROLLED• SMALL SAMPLE SIZE
![Page 6: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/6.jpg)
6
TWO BETTER MODELS:
1. CAREFUL EXPERIMENTAL CONTROL
2. MASSIVELY INCREASED SAMPLE SIZE
PROBLEMS WITH HRV
![Page 7: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/7.jpg)
7
TWO BETTER MODELS:
1. CAREFUL EXPERIMENTAL CONTROL
2. MASSIVELY INCREASED SAMPLE SIZE
PROBLEMS WITH HRV
![Page 8: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/8.jpg)
8
IDEAL MASS COLLECTION:
• Accurate• Robust• Cheap• Components
• Off shelf• Swappable
THE NEW SYSTEM
![Page 9: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/9.jpg)
9
THE NEW SYSTEM
• iOS device (iPod, iPad etc.)
• Hardware switching box
• Optical finger sensor (PPG)
• www.myithlete.com
A/DBandpassfilter
d/dtPeak
detectTime
stamp
Sensor
iPod/iPhone
Logfile
HRV
![Page 10: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/10.jpg)
10
HEATHERS et al (2012); HEATHERS (2014b)
Is pulse rate accurate enough to measure HRV?
Yes.
PROBLEMS WITH HRV
![Page 11: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/11.jpg)
11
HEATHERS (2013);HEATHERS (2014a)
Is this system accurate enough to support HRV?
Yes.
PROBLEMS WITH HRV
![Page 12: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/12.jpg)
12
“The International Food Policy Research Institute (IFPRI) seeks sustainable solutions
for ending hunger and poverty.”
THE IFPRI
![Page 13: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/13.jpg)
13
HRV in Development Economics
• HRV as stress correlate (in realistic sample)
• HRV as predictor of program success or covariate
• HRV as control against response bias
THE IFPRI
![Page 14: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/14.jpg)
14
TWO PURPOSES
1. FIELD TRIAL, IN CONTEXT
2. PROPERTIES OF MASSIVELY INCREASING SAMPLE SIZE
EXPERIMENT
![Page 15: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/15.jpg)
15
PARAMETERS• 17 enumerators (locals, no research experience)
EXPERIMENT
![Page 16: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/16.jpg)
16
PARAMETERS• 20 iPod Touch + extra sensors
EXPERIMENT
![Page 17: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/17.jpg)
17
PARAMETERS• 6 supervisors
EXPERIMENT
![Page 18: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/18.jpg)
18
PARAMETERS• Animated indicators on phone
EXPERIMENT
![Page 19: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/19.jpg)
19
SAMPLE
• N=679• n=1205 recordings• 91.7% usability (93.3% in new sample)
RESULTS
![Page 20: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/20.jpg)
20
OUTCOMES
• Age/gender relationships as expected
• Relationship with alcohol consumption (analogue of self-control?)
RESULTS
![Page 21: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/21.jpg)
21
ONGOING:
• Correlate of food-aid program (n=1142), still analysing
• Largest HRV study ever… (presently n=3408)
RESULTS
![Page 22: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/22.jpg)
22
PAPER
![Page 23: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia](https://reader035.fdocuments.net/reader035/viewer/2022070319/55842cfad8b42a79568b4f98/html5/thumbnails/23.jpg)
WLSACONVERGENCE SUMMIT
www.wirelesshealth2014.org