WESTSIDE PUMP STATION ARTIST SELECTION PANEL
MEETING 1 SUMMARY
MEETING DATE February 8, 2017 VOTING SELECTION PANELISTS Ashley Summers, Community Representative Regina Almaguer, Arts Professional Weston Teruya, Arts Professional JD Beltran, Arts Commissioner Blair Randall, Client Representative PROCESS Round One: Arts Commission staff presented the qualifications of 11 artists selected from the 2015/16 Prequalified Artist Pool for the Westside Pump Station public art opportunity. “Yes/No” majority votes based on the criteria of Artistic Excellence and Appropriate to Project Goals yielded 6 artists to move to Round Two. Round Two: The Artist Selection Panel discussed the qualifications of the semi-finalists and scored each artist on the following criteria (1= low score):
• Artistic Excellence (1-10) • Appropriate to Project Goals (1-10)
Round Two voting yielded three finalists and one alternate to recommend to the Arts Commission. RESULTS The following artists received the highest scores: Finalists: Jet Martinez 95 Jovi Schnell 86 Aileen Barr 84 t.w. five 71 ARTS COMMISSION APPROVAL| Motion: Motion to approve the following finalists for the Westside Pump Station Reliability Improvements Project Selection Panel as recommended by the Westside Pump Station Reliability Improvements Project Selection Panel: Jet Martinez, Jovi Schnell, Aileen Barr, and alternate t.w. five.
RELIABILITY IMPROVEMENTSPUBLIC UTILITIES COMMISSIONCIVIC DESIGN REVIEW - PHASE 1 - OCTOBER 17, 2016
WESTSIDE PUMP STATIONCITY & COUNTY OF SAN FRANCISCO
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 2
Project Background and Objective
PROJECT BACKGROUND AND OBJECTIVE
The Westside Pump Station has been in service for over 30 years since 1985. It is the SFPUC’s main wastewater pump station servicing the west side of the City of San Francisco therefore its continued service and reliability is critical. The objective of the Westside Pump Station Reliability Improvements Project is to increase reliability of its operations to comply with the current maximum permitted level of Combined Sewage Discharges.
SCOPE OF WORK
• Construction of a below-grade channel and a vertical shaft with connection to existing facility• Renovation/reconstruction of a portion of the existing pump station to accommodate construction of new
channel/shaft and installation of new mechanical equipment• Construction of a new electrical building to provide a redundant power feed and increase the power
capacity• Providing a new driveway for improved access and other site improvements
VICENTE STREET
LINCOLN WAY
RICHMOND WATERSHED
SUNSET WATERSHED
LAKE MERCED WATERSHED
PACIFIC OCEAN
RICHMOND TRANSPORT
TUNNEL
LAKE MERCED
TRANSPORT TUNNEL
WESTSIDE PUMP STATION
WES
TSID
E T/
S
OSP
LAKE MERCED OUTFALL
VICENTEOUTFALL
LINCOLNOUTFALL
PUMP STATION
COMBINED SEWER DISCHARGE (CSD)
WATERSHED INPUT
FORCE MAIN / PRESSURIZED FLOW
TUNNEL
TRANSPORT / STORAGE STRUCTURE
OCEANSIDE WATER POLLUTION CONTROL PLANT
SOUTHWEST OCEAN OUTFALL
SWOO
SWOO
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 3
Project Location
SLOAT BOULEVARD
GREAT H
IGH
WAY
SAN FRANCISCO ZOO
WAWONA STREET
VICENTE STREET
OC
EAN
BEACH
SKYL
INE B
OUL
EVAR
D
SOUTH SUNSET PLAYGROUND
ULLOAELEMENTARYSCHOOL
PROJECT SITE
PROJECT LOCATION
O 150’ 300’ 600’
SUN
SET BOU
LEVARD
n
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 4
Street Views
SLOAT BOULEVARD LOOKING WEST
SLOAT BOULEVARD LOOKING EAST
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 5
Street Views
GREAT HIGHWAY LOOKING SOUTH
GREAT HIGHWAY LOOKING NORTH
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 6
Existing Site Plan
GREAT HIGHWAY
SAN FRANCISCO ZOO PARKING LOT
SLOAT BO
ULEVARD
OCEAN BEACH
ACCESS DRIVE
SOUTHYARD
NORTHYARD
WESTSIDE PUMP STATION MAIN BUILDING
CONCRETE RETAINING WALL
FENCE
FENCE
SCULPTURESPLANTER, TYP.
SFPUCFACILITY
SFPUC FACILITY
O 20’ 40’ 80’ n
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 7
Photos of Existing Site
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 8
Proposed Site Plan
GREAT HIGHWAY
SAN FRANCISCO ZOO PARKING LOT
SLOAT BO
ULEVARD
OCEAN BEACH
(E) DRIVEWAY
(E) SOUTHYARD
(E) NORTHYARD
(E) PUMP STATION SCULPTURES
(P) ELECTRICALBUILDING
(P) LOW PLANTING
(P) BAR SCREEN SHAFT
SFPUCFACILITY
SFPUC FACILITY
O 20’ 40’ 80’ n
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 9
Program Area / Equipment Layout
BAR SCREEN SHAFT
SWITCHGEAR ROOM
VARIABLE FREQUENCY DRIVE ROOM
BATTERY ROOM
10’ MIN
.5’ M
IN.
8’ MIN. 8’ MIN.
ELECTRICAL ROOM W/ AIR HANDLING UNIT ABOVE
OPENING ABOVE FOR DISCHARGE POINT
EXISTING TO REMAINEXISTING TO BE MODIFIED / RECONSTRUCTED
PROPOSED ADDITIONS
O 8’ 16’ 32’ n
10’ MIN
.
SOUTHYARD
NORTH YARD
(E) PUMP STATION
8’ MIN
.
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 10
Proposed Program
WEST PUMP CHAMBER EXPANSION
NEW BAR SCREEN SHAFT
NEW ELECTRICAL BUILDING
EXISTING TO REMAINEXISTING TO BE MODIFIED / RECONSTRUCTED*
PROPOSED ADDITIONS
NEW REDUNDANT CHANNEL
* RECONSTRUCTION NECESSITATED MAINLY BY EXCAVATION FOR WORK BELOW GRADE
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 11
Program Location and Form
NEW REDUNDANT CHANNEL
WEST PUMP CHAMBER EXPANSION
(E) STAIR TO REMAINNEW OPENING IN (E) WALL FOR DISCHARGE POINT NEW BAR SCREEN SHAFT
AND HYDRAULIC POWER UNITELECTRICAL ROOM W/ AIR HANDLING UNIT ABOVE
SWITCHGEAR ROOM
VARIABLE FREQUENCY DRIVE ROOM
BATTERY ROOM
EXISTING TO REMAINEXISTING TO BE MODIFIED / RECONSTRUCTED
PROPOSED ADDITIONS
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 12
Concept Site Plan - Planting
Building Design & Construction Westside Pump Station| Team Progress Review | 09.01.2016
Concept Site Plan - Planting
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 13
Planting Palette
Building Design & Construction Westside Pump Station| Team Progress Review | 09.01.2016
Planting Palette
new zealand flaxPhormium ‘margaret Jones’infrequent
lion’s earLeonotis Leonurus
spring-fall
angelina stonecropsedum ruPestre ‘angeLina’summer
blue chalk stickssenecio mandraLiscae
summer
rock purslanecaLindrinia grandifLora
summer
blue oat grassheLictotrichon semPervirens
summer
little sur manzanitaarctostaPhyLos edmundsii
winter-spring
sea lavenderLimonium caLifornicum
late summer-early winter
coral aloeaLoe striata
winter-spring
WES
T PL
AN
TIN
G
NO
RTH
PLA
NTI
NGtaller (aBOVe 2ft)
miD (1 tO 2ft)
lOw (BelOw 1ft) lOw (BelOw 1ft)
miD (1 tO 2ft)
taller (aBOVe 2ft)
blue oat grassheLictotrichon semPervirens
summer
angelina stonecropsedum ruPestre ‘angeLina’summer
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 14
Floor Plan
AA
B B
A
A
GREAT HIGHWAY
SLOAT BO
ULEVARD
SOUTHYARD
NORTHYARD
(E) PUMP STATION
SCULPTURES
SWITCHGEARROOM
V.F.D. ROOM
BATTERY ROOMBAR SCREEN / HPU ROOM
CONTROL ROOM
ELECTRICALROOM
O 10’ 20’ 40’ n
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 15
Scheme A - Imagery
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 16
Scheme A - Great Highway - Southbound
Building Design & Construction
Westside Pump Station Reliability Improvements
CDR Views | 10.17.2016 | Page 6
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 17
Scheme A - Great Highway - Northbound
Building Design & Construction
Westside Pump Station Reliability Improvements
CDR Views | 10.17.2016 | Page 7
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 18
Scheme A - Sloat Boulevard - Eastbound
Building Design & Construction
Westside Pump Station Reliability Improvements
CDR Views | 10.17.2016 | Page 8
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 19
Scheme A - Sloat Boulevard - Westbound
Building Design & Construction
Westside Pump Station Reliability Improvements
CDR Views | 10.17.2016 | Page 9
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 20Building Design & Construction
Westside Pump Station Reliability Improvements
CDR Views | 10.17.2016 | Page 10
Scheme A - Overall Perspectival Elevation
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 21
Scheme A - Electrical Building Elevations
O 8’ 16’ 32’
EAST ELEVATION NORTH ELEVATION
SOUTH ELEVATION WEST ELEVATION
ROOF20’-2”
LEVEL 10’-0”
+10’-6”
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 22
Scheme A - Main Building Elevations
WEST ELEVATION
SOUTH ELEVATION NORTH ELEVATION
LEVEL 10’-0”
+9’-0”+10’-6”
+12’-0”
+18’-6”
+31’-0”
+12’-0”+10’-6”
O 8’ 16’ 32’
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 23
Scheme A - Building Sections
O 8’ 16’ 32’
MAIN BUILDING SECTION A-A
ELECTRICAL BUILDING SECTION B-B ELECTRICAL BUILDING SECTION A-A
ELECTRICAL ROOM
AIR HANDLING UNIT
VFD ROOM ELECTRICAL ROOM
AIR HANDLING UNIT SWITCHGEAR ROOM
BATTERY ROOM
CORRIDOR
BAR SCREEN / HPU ROOM
STORAGE
CONTROL ROOM
STORAGE
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 24
Scheme B - Imagery
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 25
Scheme B - Great Highway - Southbound
Building Design & Construction
Westside Pump Station Reliability Improvements
CDR Views | 10.17.2016 | Page 11
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 26
Scheme B - Great Highway - Northbound
Building Design & Construction
Westside Pump Station Reliability Improvements
CDR Views | 10.17.2016 | Page 12
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 27
Scheme B - Sloat Boulevard - Eastbound
Building Design & Construction
Westside Pump Station Reliability Improvements
CDR Views | 10.17.2016 | Page 13
Scheme D - Perspective View
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 28
Scheme B - Sloat Boulevard - Westbound
Building Design & Construction
Westside Pump Station Reliability Improvements
CDR Views | 10.17.2016 | Page 14
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 29
Scheme B - Overall Perspectival Elevation
Building Design & Construction
Westside Pump Station Reliability Improvements
CDR Views | 10.17.2016 | Page 15
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 30
Scheme B - Exterior Elevations
EAST ELEVATION NORTH ELEVATION
SOUTH ELEVATION WEST ELEVATION
O 8’ 16’ 32’
ROOF20’-2”
LEVEL 10’-0”
+10’-6”
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 31
Scheme B - Exterior Elevations
WEST ELEVATION
SOUTH ELEVATION NORTH ELEVATION
LEVEL 10’-0”
+9’-0”+10’-6”
+12’-0”
+18’-6”
+31’-0”
+12’-0”+10’-6”
O 8’ 16’ 32’
Building Design & Construction
Westside Pump Station - Reliability Improvements
Civic Design Review - Phase 1 | 10.17.2016 | Page 32
Scheme B - Building Sections
O 8’ 16’ 32’
MAIN BUILDING SECTION A-A
ELECTRICAL BUILDING SECTION B-B ELECTRICAL BUILDING SECTION A-A
ELECTRICAL ROOM
AIR HANDLING UNIT
VFD ROOM ELECTRICAL ROOM
AIR HANDLING UNIT SWITCHGEAR ROOM
BATTERY ROOM
CORRIDOR
BAR SCREEN / HPU ROOM
STORAGE
CONTROL ROOM
STORAGE
Jet Martinez
Jovi Schnell
Aileen Barr
t.w. five