Welcome to the New World of EstheticsThe crown can be either screw-retained to the single-unit...

Welcome to the New World of Esthetics

Transcript of Welcome to the New World of EstheticsThe crown can be either screw-retained to the single-unit...

Page 1: Welcome to the New World of EstheticsThe crown can be either screw-retained to the single-unit abutment or cemented over an abutment that is screw retained to the single unit. *Geramipanah

Welcome to the New World of

Esthetics

Page 2: Welcome to the New World of EstheticsThe crown can be either screw-retained to the single-unit abutment or cemented over an abutment that is screw retained to the single unit. *Geramipanah

The PALTOP Concepts of EstheticsCONCAVE - High Esthetic LineProsthetic Emergence Profile

High AestheticsThe unique concave design enables the soft tissue to form a dense layer surrounding the trans-gingival component. This results in reduced tissue transparency and visibility of the abutment. Enhanced Gingival HealingThis innovative design creates an optimal emergence profile, enabling replacement of temporary prosthetics with fixed prosthetics without harming the newly formed tissue structure. This reduces the trauma to the implantation site and accelerates the healing process *.

*NItzan Bichacho, Eric Van Dooren, Mauro Fradeani, Galit Talmor; Tissue management and prosthetic considerations with immediateimplantation in the anterior maxilla;

Page 3: Welcome to the New World of EstheticsThe crown can be either screw-retained to the single-unit abutment or cemented over an abutment that is screw retained to the single unit. *Geramipanah

C O N C AV EF R O M B E G I N N I N G TO E N D

Normally doctors have to perform manual modifications to prosthetic parts during treatment to make them suitable for esthetic cases.

PALTOP offers prefabricated esthetic designed parts suitable for all restorative applications, all teeth position and for all treatment stages, including the healing period, impression taking, provisional restoration (using Peek) and final restoration, cemented and screw-retained.

All parts have an identical concave profile allowing the replacement of parts according to the treatment stage without causing additional trauma to the gingiva.

Page 4: Welcome to the New World of EstheticsThe crown can be either screw-retained to the single-unit abutment or cemented over an abutment that is screw retained to the single unit. *Geramipanah

S INGLEUNITA unique system for asingle implant

restorationSystem Benefits

S.U.A connected to implant

System components: Paltop implant, S.U.A and titanium cylinder screwed together

e.max crown bonded to titanium cylinder and screw-retained on the Single Unit Abutment

An implant with two screw-retainedprosthetic components

1 2

3 4

5 76

The single-unit abutment is connected to the implant immediately after implant placement or implant uncovering. The single-unit abutment’s size is chosen according to the transgingival height. Once connected, the single-unit abutment and the implant function as one integrated unit (One Abutment - One Time) *

All the prosthetic steps are carried out at tissue level. This is a significant advantage both to patient and dentist.

The concave profile of the single-unit abutment enables maturation of the soft tissue in a thicker and stable form.

As the single-unit abutment is a solid piece (no screw hole), it eliminates penteration of any bacteria and other contaminants to the implant-abutment interface.

The crown can be either screw-retained to the single-unit abutment or cemented over an abutment that is screw retained to the single unit.

*Geramipanah F, Sahebi M, Davari M, Hajimahmoudi M,, Rakhshan V. Effects of impression levels and trays on the accuracy of impressions taken from angulated implants. Clin Oral Implants Res. 2015;26(9):1098-105

http://www.ncbi.nlm.nih.gov/pubmed/24934081

Page 5: Welcome to the New World of EstheticsThe crown can be either screw-retained to the single-unit abutment or cemented over an abutment that is screw retained to the single unit. *Geramipanah

SINGLE UNIT SYSTEMclose tray

56-70023

open tray

castable

1mm 2mm 3mm 4mm

titanium

standard platform

56-70021

80-70005

55-7001741-70057

41-70051 41-70052 41-70053 41-70054

41-70151 41-70152 41-70153 41-70154

41-70056

abutment analog

56-70022

narrow platform

Page 6: Welcome to the New World of EstheticsThe crown can be either screw-retained to the single-unit abutment or cemented over an abutment that is screw retained to the single unit. *Geramipanah

PALT

OP

Esth

etic

s Li

ne B

roch

ure

US

| Cat

No.

85-

7007

5 Re

v_03

Feb

ruar

y 20

16

ISO 13485 | ISO 9001FDA, CE Approved

www.paltopdental.com [email protected]

For More Information about PALTOP Company and Products: