Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration...

14
Weight Report Reference: LCR 56 Client: 20 Ten Show Support Ltd 27 Elbut Lane Bury BL9 7TU Show: Jersey Boys Report Date: 11 th September 2014. Load Cell Rental Limited Registered Office - 5 Harley Place, Harley Street, London, W1G 8QD Registration Number – 08260954, Director - R J Young

Transcript of Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration...

Page 1: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED

Weight Report Reference:

LCR 56

Client:

20 Ten Show Support Ltd 27 Elbut Lane

Bury BL9 7TU

Show: Jersey Boys

Report Date: 11th September 2014.

Load Cell Rental Limited Registered Office - 5 Harley Place, Harley Street, London, W1G 8QD

Registration Number – 08260954, Director - R J Young

Page 2: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED

Contents

3. About 4. Notes 5-6. Combined Insurance

Certificate 7. Weight Quick Reference 8-13. Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document.

Load Cell Rental Limited Registered Office - 5 Harley Place, Harley Street, London, W1G 8QD

Registration Number – 08260954, Director - R J Young

Page 3: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED

About

This report has been completed on behalf of the client. The measurements have been taken using electronic suspended load measuring devices that display the data to the nearest 10 units on a real time digital display. This information is then manually transferred to a computer generated form.

The stock number(s) of the equipment used have been recorded, and can be matched to the manufactures serial number. All load cells have a calibration report of less than 12 months old

The weights recorded are of the suspended load on the day of measurement. A brief description of the load is included, but this data must only be accepted with a drawing of the load, and a plan of the suspension points.

A load suspended on multiple points must be placed in a static position as expected in a normal operating environment. Readings of all suspension points must be recorded at the same time. It should be noted that the load can shift between points without obvious change in elevation. Care should be taken when using independently controlled lifting equipment to level the load.

The client accepts that changes in the load, either addition, subtraction or positional changes of equipment will change the weights present on each suspension point. Significant changes should result in the whole load being reweighed.

The recorded weight shown in this report is for the load below the load cell. The weight of rigging above the Load Cell has not been included in this report.

Every effort has been taken to ensure the accurate transfer of information from the display to the form. The client has verified the data recorded at the time of transferring. Load Cell Rental or its employees and agents shall not be held responsible for the accuracy of any drawings or plans submitted with this report.

Signed: Richard Young, Director

Load Cell Rental Limited November 2012

Load Cell Rental Limited Registered Office - 5 Harley Place, Harley Street, London, W1G 8QD

Registration Number – 08260954, Director - R J Young

Page 4: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED

Notes Reference:

LCR 56

The following specifics apply to this report.

1 The cell position for all recorded weights in this report are positioned above the motor.

2 No allowance has been made for the bridle which is positioned above the Load Cell therefore the Recorded and total for plot weights are the same.

3 The weights have been recorded by Load Cell Rental Staff on a day that the client was not available to witness the weights.

Load Cell Rental Limited Registered Office - 5 Harley Place, Harley Street, London, W1G 8QD

Registration Number – 08260954, Director - R J Young

Page 5: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED
Page 6: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED

23-33-0036 (5/05) AIGPROFCONS 170506

ii

Construction Professional Liability AIG Europe Limited The AIG Building 58 Fenchurch Street London EC3M 4AB

Schedule

Policy Number: 0034643142

Form: AIGPROFCONS1 – 170506

Item 1. Policyholder Load Cell Rental

Address Woodside Glyn Morlas Shropshire SY11 3EE

Item 2. Policy Period From: 09/10/2013

To: 08/10/2014

Both days inclusive

Item 3. Limit of Liability (all Claims in the aggregate, including Defence Costs)

GBP 1,000,000 but limited to

i) GBP250,000 in the annual aggregate in respect of Estate Agents and Health & Safety Legislation and

ii) GBP100,000 in the annual aggregate in respect of Loss of Documents

Item 4. Retention (each and every Claim, applicable to Defence Costs)

GBP 5,000

Item 5. Professional Services Construction Professional Services Item 6. Retroactive Date 09/10/2012

Item 7. Premium excluding applicable taxes

GBP 650

Item 8. Date Proposal and Declaration Signed by Policyholder

10/10/2013

DATE: 10/10/2013 AIG Europe Limited This insurance is underwritten by AIG Europe Limited which is authorised and regulated by the Financial

Services Authority (FSA number 202628). This information can be checked by visiting the FSA website

(www.fsa.gov.uk/register). AIG Europe Limited is a member of the Association of British Insurers. Registered

in England: company number 1486260. Registered address: The AIG Building, 58 Fenchurch Street, London,

EC3M 4AB.

Page 7: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED

Weights Quick Reference LCR 56

Plot

Reference Total for

plot Kgs

Weight Report

Reference

Plot Reference

Total for plot

Weight Report

Reference Adv Truss

SR 660 WR1 MS 730 WR1 SL 700 WR1

LX1 Truss SR 360 WR2 MS 400 WR2 SL 340 WR2

LX2 Truss SR 290 WR3 MS 260 WR3 SL 280 WR3

LX3 Truss SR 260 WR4 MR 200 WR4 ML 190 WR4 SL 270 WR4

LX4 Truss SR 250 WR5 SL 240 WR5

Towers SR 300 WR6 SL 310 WR6

Load Cell Rental Limited Registered Office - 5 Harley Place, Harley Street, London, W1G 8QD

Registration Number – 08260954, Director - R J Young

Page 8: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED
Page 9: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED
Page 10: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED
Page 11: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED
Page 12: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED
Page 13: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED
Page 14: Weight Report - 20 Ten Show Support Report... · Weight Report Sheet 14. Rigging Plot Calibration Certificates in separate document. ... std steel wire rope or hoseREELER WRAPPED

LX BAR

LX BAR

LX BAR

LX BAR

PB

SHOW FLOOR SET 337mm D/S OF IRON LINE

SHOW PORTAL

STREET LAMP

SHOW CHAIN LINK

BORDER

BORDER

SIDE CHAIN PANELS

CADILLAC

BRILL DOOR

BORDER

RECORDING

BORDER

HALF CHAIN

CENTRE CHAIN

BLACKOUT

MIRRORS BAR

BLACKOUT

STADIUM

FIXED LEDS

LX BAR 1

LX BAR 2

LX BAR 3

LX BAR 4

TOWER PICKUP

TOWER PICKUP

POLICE BULB

LX CROSSOVER

LX CROSSOVER

LX CROSSOVER

SETTING LINE

PORTAL 2

RP

RP

RP

RP =RIGGING POINT FOR SET / LX

RE

ELE

R

DRAG CHAIN SECTIONLOOSE CABLE SECTION

DR

AG

C

HA

IN

S

EC

TIO

N

L

O

O

S

E

C

A

B

L

E

S

E

C

T

IO

N

std steel wire rope or hoseREELER

WRAPPED CABLE SECTION

RP RP

RP

RP

RP

RPRP RP

RPRP

RPRP

RPRP

FLYING WIEGHTS LIMITED TO 900lbs

ON ALTERNATE BARS & 450lbs ON

CONSECUTIVE BARS

53

48

47

46

51

50

49

52

56

55

54

28

12

11

7

6

10

9

8

19

16

15

14

13

18

17

24

23

22

21

20

27

26

25

35

31

30

29

34

33

32

40

39

38

37

36

41

44

43

42

45

4

1 - HOUSE TABS

3

2

5

C

B

A

3 DOUBLE

PURCHASE

SETS

C

B

A

DOUBLE PURCHASE

DOUBLE PURCHASE

DOUBLE PURCHASE

53

48

47

46

51

50

49

52

57

56

55

54

RU

NW

AY

B

EA

M (I T

ON

NE

H

OIS

T)

OP SIDE UP AND

DOWN BAR

LX SUPPLY

CURTAIN

CONTROL

LX SUPPLY

LX SUPPLYLX SUPPLY

28

12

11

4

1

3

2

7

6

5

10

9

8

19

16

15

14

13

18

17

24

23

22

21

20

27

26

25

EX

TE

NT

O

F F

LY

BA

RS

BR

AILIN

G G

ALLE

RY

FLY

F

LO

OR

A

BO

VE

35

31

30

29

34

33

32

40

39

38

37

36

41

44

43

42

45

BRAILING GALLERY

EX

TE

NT

O

F F

LY

BA

RS

PROMPT SIDE UP AND

DOWN BAR

FIRE

EXIT

STADIUM

FIXED LEDS

FLOWN LEDS

FLOWN LEDS

FLOWN LEDS

LX BAR 4

LX BAR 3

SHOW PORTAL

SHOW FLOOR SETTING OUT LINE IS 1912mm U/S OF IRON LINE

RP

RP

RP

RP

RP

RP

DATE:

PRODUCTION:

SCALE:

VENUE:

DRAWN BY:

NOTES:

1:50 @ A2

S GOODING

MANCHESTER V6

24th JULY 2014

JERSEY BOYS