Weighing Terminals - Kemek · 2016. 7. 20. · weighing with METTLER TOLEDO's Drive-560 vehicle...
Transcript of Weighing Terminals - Kemek · 2016. 7. 20. · weighing with METTLER TOLEDO's Drive-560 vehicle...
IND560 PDX − Versatile technology for vehicle weighing applications
IND560 PDX weighing terminalThe IND560 PDX is unique because, unlike any other terminal, it immediately notifies your operator of cell failure or breach before inaccurate weight causes you to lose money.
Unlike conventional systems which can require hours of trouble-shooting when a failure occurs, the IND560 PDX interfaces with METTLER TOLEDO POWERCELL® PDX® load cells to provide real-world diagnostic infor-mation. This information allows a technician to ana-lyze your scale's health and, in the unlikely event of a failure, quickly find and replace the failed component, to get the system up and running in just minutes.
Complywith local and regional requirements. Cer-tification to globally recognized metrologi-cal and performance standards supports acceptance in local markets.
Weighwith confidence using POWERCELL® PDX® load cells. With absolutely no junc-tion box, these cells deliver accurate, secure and reliable weight to the IND560 PDX terminal. The system has been independently tested to survive lightning strikes – a leading cause of scale failure.
Controlsimple inbound and outbound vehicle weighing with METTLER TOLEDO's Drive-560 vehicle application software. Integrate material transfer operations into the vehicle weighing process using discrete I/O options with the built-in filling logic of the IND560 PDX.
Connecteasily to new and existing systems through two standard, electrically-isolated serial ports, or options such as Ethernet TCP/IP, USB and a variety of PLC interfaces. The IND560 PDX supports user-defined print ticket formats and reports.
Wei
ghin
g Te
rmin
als
www.mt.com/IND5xxFor more information
Technical data
IND560 PDX Vehicle Weighing TerminalTerminal interface for the most powerful load cell technology available
Features and Benefits• IND560PDXterminalwithPOWERCELL® PDX® load cells – provides the
industry's highest accuracy.• Proactivemonitoringofdiagnosticinformationfromindividualcells,withoutthe
need for maintenance-prone external analog-to-digital converter boxes.• Precisiondiagnosticsreducetechnicianrepairtimetominutesinsteadofhours.• Enjoyexcellentvisibilityatadistance.Alarge,brightvacuumfluorescentdisplay
provides visibility in both low light and bright sunlight.• Simultaneouslyinterfacewithmultipleperipheralsincludingprintersandlarge-
character remote displays.• OptionalMETTLERTOLEDODrive-560softwaresupportsbasicone-andtwo-pass
weighing and can store up to 100 truck IDs at a time.• OptionalUSBQWERTYkeyboardinterfacepermitsfastandeasydataentry.• Turnatruckscaleintoanaccuratefillingsystem:materialtransfermodecontrols
vehicle filling with less hardware.• Gettheexactperformanceyouneed.TaskExpert™programmingtoolenablesthe
creation of custom applications.• Customizeandstoreuptofiveprinttemplates.• Approvedalibimemoryfornon-corruptibleaccountingofallregisteredvehicles.• Fourlevelsofsecurityprovidevariedaccesstosystemandmetrologysetup.
Enclosure dimensions (LxWxD) Harshmodel:265x160x170.3mm(10.4x6.3x6.7in.)Panelmount:265x160x91.8mm(10.4x6.3x3.6in.)
Enclosure construction Harshmodel:Stainlesssteel,IP69KcertifiedPanelmountmodel:Stainlesssteelfrontpanel,certifiedtype4x/12protection
Shipping weight 3.5kg(7.7lbs)
Power Universalpowersupply,87to264VACat49to61Hz,600mAconsumption
Operating environment -10°Cto+40°C(14°Fto104°F),10%to95%relativehumidity,non-condensing
Display Vacuumfluorescent,21mmweightdisplay,graphiccapabilities;128x64dotmatrix.Maximumresolution100,000divisions
Keypad Clear,Tare,Print,Zero,navigationkeyset,fullnumericalkeypad,alphanumericcapability,5physicalsoftkeys(15totalassignments)
Supported scale types Powerupto14POWERCELL® PDX® load cells
Calibration options Flexiblecalibrationoptionsinclude:Traditionalcalibrationwithseparatezeroandspancaptures;5-pointlinearization;step-calibration;CalFREE™electroniccalibration(requiresnotestweights)fornon-approvedapplicationsProgramandstorearepeatablecalibrationsequence(upto20steps)Configurable calibration alerts and actions
Connectivity 2electricallyisolatedserialportsstandard(COM1:RS-232/RS-422/RS-485,COM4:RS-232)Optional10Base-TEthernetTCP/IPportwithtwoadditionalserialports(COM2:RS-232;COM3:RS-232/422/485)OptionalCOM3/USB/Ethernet:COM3withRS-232/RS-485,USBandEthernetTCP/IP
Interface options PLC(selectoneoption):Allen-Bradley® Remote I/O, PROFIBUS®DP,DeviceNet™,AnalogOutput(4-20mAor0-10VDC), EtherNet/IP™,ModbusTCPLocalandRemoteI/O(relay-based):Maximumof12inputsand18outputs
Agency approvals Weights and measuresUSA:ClassII100,000d,ClassIII/IIIL10,000d,CoC05-057A2Canada:ClassII100,000d,ClassIII10,000d,ClassIIIHD20,000d,AM-5593Europe:ClassIIdeterminedbyplatform,ClassIII10,000e,ClassIIII1000e.IncludesAlibiMemory,T2206,T2391Australia:ClassIII7500eor3x3000emultiplerange,NMIS483(pending)
Electrical SafetyPanel:ULRecognizedComponentI.T.E.202B;CEHarsh:cULusI.T.E.202B;CE
14001Mettler-Toledo, LLC1900PolarisParkwayColumbus,OH43240U.S.A.+18007860038
Subject to technical changes©06/2012Mettler-Toledo,LLCINDB0077.3E
Mettler-Toledo AGIndustrialIm Langacher8606GreifenseeSwitzerland+41449444545