WebEngine Viper NT WebEngine Roadster USER...

78
25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 www.networkengines.com WebEngine ViperNT and WebEngine RoadsterNT USER GUIDE Software Version 1.0 P/N 510-1007-01 REV 0A

Transcript of WebEngine Viper NT WebEngine Roadster USER...

Page 1: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

WebEngine Viper™ NTand

WebEngine Roadster™ NT

USER GUIDESoftware Version 1.0

P/N 510-1007-01REV 0A

25 Dan Road, Canton, MA 02021-2817(781) 332-1900 Fax: (781) 770-2000

www.networkengines.com

Page 2: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Copyright © 2000 Network Engines, Inc.

WebEngine Viper NT and WebEngine Roadster NT User Guide

Printed July, 2000

All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of Network Engines, Inc.

TrademarksIntel® and Celeron® are trademarks of Intel Corporation, Inc.

Microsoft®, Internet Explorer®, Windows®, and Windows NT® are registered trademarks of Microsoft Corporation.

Netscape® is a registered trademark of Netscape Communications Corporation.

The Network Engines logo, WebEngine Viper™, WebEngine Roadster™, and AdminEngine™ are trademarks of Network Engines, Inc.

Other brand and product names may be registered trademarks or trademarks of their respective companies.

Product WarrantyWARRANTY: Network Engines, Inc. (NEI) warrants its Products for a period of one (1) year from the date of shipment to be free from defects in material and workmanship, provided that the Products are installed, operated and maintained in accordance with NEI specifications. Product purchased under this Agreement will be newly manufactured by NEI from new parts and serviceable used parts, which are equivalent to new in performance. During the warranty period, NEI will, at its option repair or replace any Product it deems to be defective. Warranty service is return-to-factory and a Return Material Authorization (RMA) number must be obtained from NEI Customer Support before any Product may be returned. Standard warranty repair turn-around time is approximately ten (10) business days after receipt of the defective Product, FOB Canton, MA 02021. Repaired or replaced Products will be warranted for the remainder of the standard warranty period.

EXCLUSIONS, DISCLAIMERS AND LIMITS ON WARRANTY:a. No representation or other affirmation of fact, oral or written, including but

not limited to statements regarding capacity, suitability for use or performance of Products, whether made by NEI employees or otherwise, shall be deemed to be a warranty by NEI or its licensors for any purpose, or give rise to any liability of NEI or its licensors whatsoever, unless contained in this Agreement. The express warranty stated in the section above entitled “Warranty” is the only warranty given. THERE ARE NO OTHER

Viper NT and Roadster NT User Guideii

Page 3: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, FOR PRODUCTS OR SERVICES FURNISHED IN CONNECTION WITH THIS AGREEMENT. NEI AND ITS LICENSORS DISCLAIM ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT.

b. Should NEI be unable to correct a defect covered under the section entitled “Warranty” after the expenditure of reasonable efforts and time, “reasonable” to be defined by the nature of the defect when encountered, Buyer shall be entitled to return the Product and receive a refund at the net purchase price paid for the returned Product, and such refund shall constitute NEI’s and its licensors’ maximum aggregate liability for breach of warranty.

LIMITATION OF REMEDY AND LIABILITY: IN NO EVENT SHALL NEI OR ITS LICENSORS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES WHATSOEVER, INCLUDING BUT NOT LIMITED TO LOST PROFITS AND DAMAGES RESULTING FROM LOSS OF USE OR LOST DATA EVEN IF NEI OR ITS LICENSORS HAVE BEEN ADVISED, KNEW OR SHOULD HAVE KNOWN OF THE POSSIBILITY THEREOF, OR FOR ANY CLAIM BY ANY THIRD PARTY EXCEPT TO THE EXTENT PROVIDED IN THE SECTION ENTITLED “INDEMNITY.” Any action against NEI must be commenced within one (1) year after the cause of action accrues.

NEI shall not be liable for any errors of fact or omissions of fact contained herein, or for incidental, indirect, special or consequential damages in connection with the furnishing, performance, or use of this and related documentation.

Viper NT and Roadster NT User Guide iii

Page 4: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Viper NT and Roadster NT User Guideiv

Page 5: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Contents

Preface ...................................................................................ix

1 OverviewHardware Features .....................................................................2Software Features ......................................................................3Front and Rear Panels ................................................................3

Front Control Panel .............................................................4LCD Panel ...........................................................................6Rear Panel ...........................................................................9

2 Installing an NT AppliancePre-Installation .........................................................................11

Tools Required ..................................................................11Site Preparation .................................................................11Unpacking .........................................................................12

Installing NT Appliance on a Desktop ....................................12Installing NT Appliance in a Telco Rack ................................13Installing NT Appliance in a Standard 19-inch Rack ..............14

3 Cabling an NT ApplianceConnecting the Power Cable ...................................................17Connecting Ethernet Cables ....................................................17Connecting the CMBus Cable .................................................18Connecting the Console Cable Adapter ...................................18

Viper NT and Roadster NT User Guide v

Page 6: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Identifying Cabling Configurations .........................................18Cabling for a Viper NT Cluster ........................................19Cabling for a Roadster NT Cluster ...................................20Cabling for Mixed Cluster Viper NT and Roadster NT ...20

4 Configuring an NT ApplianceNIC Interfaces .........................................................................23Configuring NIC Interfaces .....................................................24

Powering On the NT Appliance .......................................24Selecting DHCP for IP Addressing ..................................25

Using the Engine Configuration Screen ..................................31Setting Up Your Web Browser ..........................................31Powering Up the NT Appliance .......................................32Engine Configuration Screen ............................................33Navigation .........................................................................35Screen Descriptions ..........................................................35

Configuring Internet Information Server (IIS) ........................37

5 Operating an NT ApplianceShutting Down .........................................................................40Rebooting ................................................................................41Redirecting a Reboot ...............................................................42Powering Off ...........................................................................43Resetting .................................................................................44Displaying the Unique ID ........................................................45Displaying MAC Addresses ....................................................46Providing Automatic Focus to Viper NT .................................47Setting the Power-up Mode .....................................................48

6 Removing and Replacing an NT ApplianceReplacing a Standalone NT Appliance ....................................51Replacing a Clustered NT Appliance ......................................51

Viper NT and Roadster NT User Guidevi

Page 7: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

A Specifications

Index .....................................................................................63

Viper NT and Roadster NT User Guide vii

Page 8: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Viper NT and Roadster NT User Guideviii

Page 9: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Preface

AudienceThis guide is intended for Information Technology professionals who install, configure, and maintain a Network Engines clustered Viper NT or Roadster NT web server appliance, also called NT appliance.

ScopeThis guide describes how to install, configure, and operate a Viper NT or Roadster NT as a standalone or clustered NT appliance.

Chapter 1, Overview, provides a hardware overview.

Chapter 2, Installing an NT Appliance, describes how to install and connect an NT appliance as standalone or in a cluster of appliances.

Chapter 3, Cabling an NT Appliance, describes how to cable an NT appliance.

Chapter 4, Configuring an NT Appliance, describes how to configure an NT appliance using the LCD panel and the Engine Configuration screen.

Chapter 5, Operating an NT Appliance, describes how to operate an NT appliance including tasks such as resetting and powering off.

Chapter 6, Removing and Replacing an NT Appliance, describes how to remove and replace an NT appliance that is already installed in an operational cluster.

Appendix A, Specifications, describes specifications for the NT appliance.

Viper NT and Roadster NT User Guide ix

Page 10: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Conventions Used in this ManualThe following conventions are used for notes, cautions, warnings, and danger notices:

A note presents information that is important, but not hazard-related.

CAUTION!

A caution contains information essential to avoid damage to the system or equipment. The caution may apply to hardware or software.

WARNING

A warning contains information essential to avoid a hazard that can cause severe personal injury, death, or substantial property damage if you ignore the warning.

DANGER

A danger notice contains information essential to avoid a hazard that will cause severe personal injury, death, or substantial property damage if you ignore the warning.

The following style conventions are used in this guide.

Convention Example

Angle brackets separate single keys that you press from surrounding text.

Press <Ctrl>

Boldface identifies numbers and characters that you type.

Type reset (dio) AC-OK-2

Courier indicates code lines and screen displays.

On IPport-1 = S

Italics emphasize file names and variable information.

See the multitsk.cfg file

Viper NT and Roadster NT User Guidex

Page 11: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Where to Get HelpUse the following telephone numbers to contact Network Engines:

• For technical support, telephone (781) 332-1900

• For sales and general information, telephone (781) 332-1000

• To send a fax, use (781) 770-2000

You can also contact us by using the following e-mail and Internet addresses:

Email Support:

Information:

[email protected]

[email protected]

Web Information: http://www.networkengines.com

Viper NT and Roadster NT User Guide xi

Page 12: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Viper NT and Roadster NT User Guidexii

Page 13: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

CHAPTER 1

This chapter describes the NT web server appliance including Viper NT and Roadster NT. Included are general descriptions of the NT appliance features, and detailed descriptions of the front and rear panels of these devices.

The NT appliance is a Windows NT-based enterprise-class web server appliance that operates stand-alone or can be added to an existing cluster. You can connect an NT appliance to a network using a hub or a switch, and manage it using AdminEngine™. AdminEngine is a management server appliance that manages a cluster of NT appliances through the Cluster Maintenance Bus (CMBus).

Figure 1 shows the front view of Viper NT.

Figure 1. Viper NT

Overview

Reset

Focus

Viper

Menu

Overview 1

Page 14: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Overview1

Figure 2 shows the front view of Roadster NT.

Figure 2. Roadster NT

Use the LCD panel on the front panel of either appliance (Viper NT or Roadster NT) to configure the system.

Hardware FeaturesThe NT appliance is a single 1 U (1.75 inch) rack-mounted chassis with hardware features that can vary between the Viper NT and Roadster NT. Table 1 lists the differences and similarities between Viper NT and Roadster NT.

Table 1. Hardware Features for Viper NT and Roadster NT

Viper NT Roadster NT

Processor Single or dual Intel®

Pentium® III processors

Single Intel Celeron processor

DRAM Up to 2GB DRAM Up to 512 MB DRAM

Other Hardware Features

Dual 10/100 Mbps Ethernet interfaces

√ √

Two serial ports √ √

Reset

ON

Roadst

er NT

Menu

Viper NT and Roadster NT User Guide2

Page 15: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Overview 1

Software FeaturesThe software features include:

• Windows NT operating system• Web browser interface

Front and Rear PanelsThe following sections describe the NT appliance’s LEDs, navigation buttons, and LCD panel on the front panel, and the external connectors on the back panel.

LCD panel for easy configuration

√ √

Stand-alone or clustered configurations

√ √

Remote management capabilities

√ √

One or two Integrated Device Electronics (IDE) or Small Computer System Interface (SCSI) disk drives

√ √

System Maintenance Bus for out-of-band management

√ √

Cluster Maintenance Bus (CMBus) external connection for easy integration with a Network Engines cluster

√ √

Optional CD-ROM drive √ N/A

Optional floppy disk drive √ N/A

Table 1. Hardware Features for Viper NT and Roadster NT

Viper NT Roadster NT

Software Features 3

Page 16: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Overview1

▼ Front Control PanelThe front control panels of the Viper NT vary slightly from the Roadster NT due to the focus feature that is part of Viper NT.

Figure 3 shows the front control panel of Viper NT.

Figure 3. Viper NT Front Control Panel

Figure 4 shows the front control panel of Roadster NT.

Figure 4. Roadster NT Front Control Panel

*FocusViper

Menu Reset

Navigation Buttons

Watch DogTemperature

Power

HDDLAN2LAN1

Indicator LEDs

Left-Select

Toggle-BackReset

Toggle-Forward

Right-Select

ONRoadster

Menu Reset

Navigation Buttons

Watch DogTemperature

Power

HDDLAN2LAN1

Indicator LEDs

Left-Select

Toggle-BackReset

Toggle-Forward

Right-Select

Viper NT and Roadster NT User Guide4

Page 17: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Overview 1

Table 2 describes the front panel LEDs, which are the same for Viper NT and Roadster NT.

Table 2. Front Panel LED s

LED Name Description

LAN1 Amber - Indicates Ethernet activity on LAN1.

LAN2 Amber - Indicates Ethernet activity on LAN2.

HDD Amber - Indicates activity on hard drive(s).

WatchDog Amber - Flashes when the operating system is running properly. Is solid when the operating system is not running properly. You may have to restart the appliance if the LED remains solid amber.

Temperature Red - Indicates an over-temperature (alarm) condition. Call Technical Support. You may be asked to use the LCD panel to obtain the Alert ID number.

Power Green - Indicates that the power is on. When you press the Right-Select button on the LCD panel, the appliance powers up.

Front and Rear Panels 5

Page 18: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Overview1

Table 3 describes the front panel buttons, which are the same for Viper NT and Roadster NT.

Table 3. Front Panel Buttons

▼ LCD PanelUse the LCD panel to perform configuration and operational tasks on the NT appliance. You do not need a keyboard, monitor, and mouse. Using the LCD panel you can configure the NT appliance before installing it in the network, and then perform operational tasks once it is installed.

If the LCD panel displays error messages, contact Technical Support.

Button Description

Toggle-Back When you press this button, it moves backward through the menu items on the front panel.

Left-Select When you press this button, it selects the lower left field on the panel.

Toggle-Forward When you press this button, it moves forward through the menu items on the front panel.

Reset When you press this button, it performs a standard PC reset, causing the system to reboot.

Right-Select When you press this button, it selects the lower right field on the panel.

Viper NT and Roadster NT User Guide6

Page 19: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Overview 1

Table 4 describes the LCD configuration and operational tasks for the NT appliance. These features are the same for Viper NT and Roadster NT, except for the Auto Focus feature on Viper NT.

Table 4. LCD Configuration and Operational Tasks

Menu Selection Description

Power On/Off Powers the NT appliance on and off. This mode performs a hard (immediate) power-off. It is not an orderly shutdown.

NIC Setup Allows you to configure network ports:• Select DHCP to assign an IP address, subnet

mask, and default gateway

or

• Configure a static IP address and subnet mask for each network port.

Default Gateway Sets the default gateway address.You do not need to configure a default gateway if you select DHCP for IP addressing – DHCP automatically configures it.

Auto Focus If selected, when you power on Viper NT, the system turns on the device and gives it focus. An NT appliance has focus when the video monitor, mouse, and keyboard connections are enabled through its CMBus.This menu selection applies only to Viper NT. It does not apply to Roadster NT.

Default Power Sets the start-up mode:

• If set to On (hard start), when the appliance is powered on using the switch on the rear panel (AC power), the operating system boots.

• If set to Off (soft start), when the appliance is powered on using the switch on the rear panel, it enters idle mode (LCD panel displays On). Press the Right-Select button to power up the appliance and boot the operating system (default mode).

Front and Rear Panels 7

Page 20: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Overview1

Clean Shutdown Shuts down all processes and the operating system in an orderly fashion.

Clean Reboot Shuts down all processes and the operating system, and then reboots the NT appliance.

Boot Redirect When enabled, the NT appliance boots from a Preboot Execution Environment (PXE) server the next time it boots. You can use this feature to install a new operating system image or fix a corrupted operating system.

Reset Performs a hard reset. The NT appliance reboots the operating system without shutting down the processes.

Show Unique ID Displays the NT appliance unique address (serial number and vendor ID) in hexadecimal format.

Show MAC Address Displays the MAC addresses of the two Ethernet ports on the NT appliance.

CAUTION!

The following menu items are for information only. Do not make any changes to these menu items unless directed to do so by Technical Support.

Show CMB Addr Displays the CMBus address. In a new cluster installation, the first NT appliance powered on acquires a CMBus address of 2 by default. As each additional appliance in the cluster is powered on, it seeks its own unique CMBus address by polling the other appliances connected to the CMBus. It is important that appliances are powered on and complete their booting sequence, one at a time, to avoid potential address conflicts.Once an appliance initially determines its CMBus address, its identification number (CMBus ID) is stored in the EEPROM of its maintenance processor. Then, you can safely power the appliance on or off in any sequence without the possibility of address conflicts.

Clear Temp LED Clears the temperature LED (used for testing). It does not clear the alarm condition.

Table 4. LCD Configuration and Operational Tasks (continued)

Menu Selection Description

Viper NT and Roadster NT User Guide8

Page 21: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Overview 1

▼ Rear PanelThe rear panels of the Viper NT vary from the Roadster NT due to the different cabling configurations of each appliance.

Figure 5 shows the connectors on the Viper NT rear panel.

Figure 5. Viper NT Rear Panel Connectors

Show Alert ID Shows the temperature sensor’s address.

Default CMB Addr Changes the CMBus address (used for testing).

Disable Temp LED Permanently disables the temperature LED until you power off the appliance and then power it on again using the On/Off switch on the rear panel.

Table 4. LCD Configuration and Operational Tasks (continued)

Menu Selection Description

On/Off Switch

AC Power Outlet

Indicator LEDsPCI Option 1PCI Option 2

COM 1COM 2

CMBus OutCMBus In

USB ConnectorsNetworkConnectors

Front and Rear Panels 9

Page 22: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Overview1

Figure 6 shows the connectors on the Roadster NT rear panel.

Figure 6. Roadster NT Rear Panel Connectors

AC Power OutletOn/Off Switch

Serial ConnectorsCMBus ConnectorsConsole ConnectorPCI Option ConnectorPCI Adapter Expansion Slot

USB Connectors

SCSI OptionConnector

NetworkConnectors

Indicator LEDs

Viper NT and Roadster NT User Guide10

Page 23: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

CHAPTER 2

This chapter describes hardware installation procedures for the NT appliance, including Viper NT and Roadster NT. Included are procedures for installing the appliance on the desktop, in a Telco rack, or in a standard 19-inch rack.

Although diagrams and procedures in this chapter show the Roadster NT, these procedures also apply to the Viper NT.

Pre-InstallationEach NT appliance is shipped with chassis mounting hardware, power cable, Console Cable Adapter, and CMBus cable.

▼ Tools RequiredTo mount the chassis rails, you need a #2 Phillips screwdriver. You may also need a small, flathead screwdriver to secure the monitor connector.

▼ Site PreparationBefore you begin, review these safety precautions:

• Do not block the cooling vents or restrict air flow through the appliance chassis.

• Make sure that each rack used is securely mounted in place.

• When installing multiple units in a rack, make sure the overall loading for each branch circuit does not exceed the rated capacity. Refer to Appendix A, Specifications.

Installing an NTAppliance

Installing an NT Appliance 11

Page 24: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Installing an NT Appliance2

• Each rack system and each appliance requires a reliable ground. Appliances should be connected to an earth-ground connection through the AC line cord.

Also, install the appliance in or near:

• Controlled environments that meet Network Engines’ specifications for ambient temperature and humidity. Refer to Appendix A, Specifications.

• Areas with adequate support or floor loading capacity to support the current installation and possible future growth.

• AC outlets for each appliance and one for a monitor.

• Appropriate earth-ground connections for each rack and each appliance.

• Ethernet hubs or individual jacks (10/100 Base-T cables cannot be longer than 100 meters).

▼ Unpacking• Check the packing list provided with the appliance to verify that you

received all the equipment, software, and manuals. If any item is missing, contact:

Network Engines Customer SupportTel: (781) 332-1900Email: [email protected]: http://www.networkengines.com/supportmain.htm

• Remove all protective coverings and uncoil cables.

• Make copies of the packing slips and file the originals with your records. Keep the copies in a binder with this manual for future reference.

Installing NT Appliance on a DesktopTo avoid damage to the units, do not install more than six (6) NT appliances in a single stack on the desktop.

Viper NT and Roadster NT User Guide12

Page 25: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Installing an NT Appliance 2

Installing NT Appliance in a Telco RackBefore you install an NT appliance in a Telco rack, make sure that the rack is bolted securely to the floor.

To install an NT appliance:

1. Unpack the appliance, locate the chassis mounting hardware, and mount the two Telco brackets to the sides of the appliance chassis (Figure 7).

2. Align the bracket and appliance chassis with the Telco rack.

3. Secure with the four screws.

CAUTION!

To prevent equipment damage, support the appliance until all four fasteners are fastened securely to the Telco rack.

Figure 7. Telco Rack Installation

Reset

ON

Roadst

er NT

Menu

Reset

ON

Roadst

er NT

Menu

Screw

Telco Bracket

Screw

Telco Rack

Reset

ON

Roadst

er NT

Menu

Installing NT Appliance in a Telco Rack 13

Page 26: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Installing an NT Appliance2

Installing NT Appliance in a Standard 19-inch RackUnpack the NT appliance, and locate the mounting screws and end brackets. Then follow these steps:

1. Attach the end brackets to the inside rear of the stationary track (Figure 8).

Figure 8. Attaching End Brackets

2. Align the end bracket with the rack in the rear and secure with screws and bar nut (Figure 9).

Figure 9. Aligning End Brackets with Rack

ScrewEnd BracketStationary TrackBar Nut

Retainer NutScrew CollarScrew

ScrewEnd BracketRackBar Nut

Stationary Track

Viper NT and Roadster NT User Guide14

Page 27: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Installing an NT Appliance 2

3. Attach the stationary track rails to the rack. Secure with mounting screws, screw collar, and retainer nut (Figure 10). The smaller side of the retainer nut should face the rack from the rear (screw collar).

Figure 10. Attaching Stationary Track Rails to the Rack

4. Mount the two S-type chassis rails to the appliance chassis (Figure 11).

Figure 11. Mounting Chassis Rails to the NT Appliance

Retainer NutScrew CollarScrew

Reset

ON

Roadst

er NT

Menu

IntermediateChassis

ScrewS-Type Chassis

Installing NT Appliance in a Standard 19-inch Rack 15

Page 28: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Installing an NT Appliance2

5. Align the appliance chassis rails with the cabinet rails and slide the unit into the cabinet until the rails lock in place (Figure 12).

Figure 12. Aligning Rails and Sliding the NT Appliance in the Rack

6. Depress the lock/release button on each side of the rails and slide the chassis completely into the cabinet.

The intermediate rail has a lock/release button. Be sure to release this button if it is locked.

Reset

ON

Roadst

er NT

Menu

Lock/Release

Lock/Release

Viper NT and Roadster NT User Guide16

Page 29: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

CHAPTER 3

Before powering up and configuring an NT appliance for the first time, connect the appropriate cables. This chapter describes how to:

• Connect the power cable.

• Connect the Ethernet cables.

• Connect the CMBus cables.

• Connect the Console Cable Adapter (optional).

• Identify cabling configurations.

For detailed diagram information on these procedures, refer to the section Identifying Cabling Configurations on page 18.

Connecting the Power Cable Connect the power cable for the NT appliance to a grounded AC power outlet. Facing the rear of the appliance, (see t) the power cable is located on the far left side of each appliance.

Connecting Ethernet CablesEthernet cables connect NT appliances to internal and external networks. To connect an Ethernet cable, do the following and refer to Figure 14 on page 20:

1. Connect the Ethernet cable from the internal switch or hub to the top port.

2. Connect the Ethernet cable for external access from the appropriate switch or hub to the bottom port.

Cabling an NT Appliance

Cabling an NT Appliance 17

Page 30: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Cabling an NT Appliance3

Connecting the CMBus CableTo connect the CMBus cable, do the following and refer to Figure 14 on page 20:

1. Connect a CMBus cable to the left CMBus connector on the first appliance (typically an AdminEngine). Connect the other end to the right CMBus connector on the next appliance.

2. Continue cabling the remaining appliances in a similar cross-over manner.

Connecting the Console Cable AdapterThe Console Cable Adapter allows you to (optionally) access AdminEngine through a directly connected VGA monitor, keyboard, and mouse. To connect the Console Cable Adapter, do the following and refer to Figure 15 on page 21:

1. Connect a Console Cable Adapter to the console connector.

2. Attach the Console Cable Adapter to the other end of the cable.

3. Connect the keyboard, mouse, and VGA cables to the Console Adapter.

Identifying Cabling ConfigurationsThis section includes diagrams that show cabling configurations for:

• Viper NT cluster

• Roadster NT cluster

• Mixed cluster of Viper NT and Roadster NT

Viper NT and Roadster NT User Guide18

Page 31: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Cabling an NT Appliance 3

▼ Cabling for a Viper NT ClusterThe cable connections for a Viper NT cluster are shown in the following diagram.

Figure 13. Cabling for a Viper NT Cluster

VGA CableKeyboard CableMouse Cable

Console Cable Adapter

Network Engines, Inc.Console Cable Adapter ADP-CMBUS-000

Mouse Keyboard VGA

CMB Console Cable

CMBus/Console Cable

CMBus In CMBus Out

Identifying Cabling Configurations 19

Page 32: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Cabling an NT Appliance3

▼ Cabling for a Roadster NT ClusterFigure 14 shows cable connections for a Roadster NT cluster.

Figure 14. Cabling for a Roadster NT Cluster

▼ Cabling for Mixed Cluster Viper NT and Roadster NTFigure 15 on page 21 shows cable connections for a mixed cluster of Roadster NT and Viper NT appliances.

Console Cable Adapter

Network Engines, Inc.Console Cable Adapter ADP-CMBUS-000

Mouse Keyboard VGA

CMB Console Cable

CMBus Cable

CMBusCables

EthernetCables

Viper NT and Roadster NT User Guide20

Page 33: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Cabling an NT Appliance 3

Figure 15. Cabling for Mixed Cluster Viper NT and Roadster NT

10

10

10

VGA CableKeyboard CableMouse Cable

Console Cable Adapter

Network Engines, Inc.Console Cable Adapter ADP-CMBUS-000

Mouse Keyboard VGA

CMB Console Cable

CMBus/Console Cable

CMBus Cable

Identifying Cabling Configurations 21

Page 34: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Cabling an NT Appliance3

Viper NT and Roadster NT User Guide22

Page 35: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

CHAPTER 4

After you complete the cable connections on the NT appliance, power on the appliance and configure the following:

• Network Interface Card (NIC) interfaces and default gateway

• Settings such as computer name, and time and date found in the Engine Configuration screen

• Internet Information Server (IIS)

Configure the appliance through the LCD panel or through the Engine Configuration screen using a web browser. For initial configuration, use both methods.

Although diagrams and procedures in this chapter show the Roadster NT, these procedures also apply to the Viper NT.

NIC InterfacesThe NT appliance has two NIC interfaces configured with default IP addresses that correspond to Ethernet ports on the back panel shown in Figure 16.

Figure 16. Ethernet Ports

Configuring an NT Appliance

E100B2NIC1

E100B1NIC2

10.10.10.10

192.168.30.2

Configuring an NT Appliance 23

Page 36: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance4

Table 5 shows the default IP addresses and subnet masks for the appliance’s two NIC interfaces.

You must configure these interfaces so that they do not conflict with addresses on existing devices in the network. If the appliance’s address 10.10.10.10 on subnet 255.0.0.0 conflicts with a system on your network, you must change the appliance’s IP address while connected to a private network.

If the appliance’s address 192.168.30.2 on subnet 255.255.255.0 conflicts with another system on your network, you must change the IP address. Each address must be unique.

Configuring NIC InterfacesBefore configuring the NIC interfaces, obtain an IP address from your network administrator. Then use the LCD panel on the NT appliance and the procedures in the following sections to:

• Select DHCP for IP addressing

or

• Configure static IP addresses

You can configure one Ethernet port with DHCP and the second Ethernet port with a static IP address.

▼ Powering On the NT ApplianceTo power on the NT appliance:

1. Power on (AC) the appliance using the On/Off switch on the rear panel.

Table 5. Default NIC Parameters

Interface/NIC IP Address Subnet Mask Location

E100B2 (NIC 1)(internal address) 192.168.30.2 255.255.255.0 Top port

E100B1 (NIC 2)(external address)

10.10.10.10 255.0.0.0Bottom port

Viper NT and Roadster NT User Guide24

Page 37: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance 4

2. Press the Right-Select button on the front panel to turn on the appliance.

3. Wait until the Watchdog LED starts flashing or Ready appears on the LCD panel.

▼ Selecting DHCP for IP AddressingYou can use the Microsoft DHCP Server Services on AdminEngine to automatically configure IP addresses, subnet masks, and a default gateway. If you configure the interface for DHCP, the netmask (subnet mask), and the default gateway are automatically set.

To select DHCP for IP addressing for both Ethernet ports:

1. Press the Left-Select button on the front panel to access the menu items.

2. Press the Right-Select button to select the NIC Setup menu item. Use the Toggle-Forward button until NIC ID: E100B2 (interface for internal IP address) appears.

3. Press the Right-Select button to set up NIC ID: E100B2 configuration.

4. At the DHCP menu item, press the Right-Select button to select it.

5. Press the Toggle-Forward button to switch DHCP from Off to On.

6. Press the Left-Select button to confirm that DHCP is on and will assign the IP address, subnet mask, and default gateway.

RoadsterMenu Ready

SelectNIC SetupExit

SetupDoneNIC ID:E100B2

SelectDHCPExit

CancelDHCP=OffOK

CancelOKDHCP=On

Configuring NIC Interfaces 25

Page 38: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance4

7. Press the Left-Select button to exit DHCP.

8. Press the Toggle-Forward button to access the NIC ID: E100B1 configuration. Press the Right-Select button to select setup for NIC ID: E100B1 configuration. Repeat Steps 4, 5, 6, and 7 to configure DHCP for NIC ID: E100B1.

9. Press the Left-Select button to complete configuration for NIC ID: E100B1; press the Left-Select button to reboot the appliance.

Configuring a Static IP AddressIf you configure static IP addresses, you need to configure the IP address and subnet mask for Ethernet ports and a default gateway. Be sure that the DHCP menu item is set to Off before you configure a static IP address.

To configure a static IP address for an Ethernet port:

1. Press the Left-Select button on the front panel to access the menu items.

2. Press the Toggle Forward or Toggle-Back button until the NIC Setup menu item appears, then use the Right-Select button to select the menu item.

3. Press the Right-Select button to select setup for the NIC ID: E100B2 configuration.

SelectDHCPExit

SetupNIC ID:E100B1Back

NoReboot?Yes

RoadsterMenu Ready

SelectNIC SetupExit

SetupNIC ID:E100B2Back

Viper NT and Roadster NT User Guide26

Page 39: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance 4

4. Press the Toggle-Forward button until the IP Address menu item appears, then press the Right-Select button to select the menu item.

5. Press the Left-Select button to change the number incrementally. Press the Toggle-Forward button to move the cursor to the next field. Repeat this step until you have configured all the fields of the IP address. Then press the Right-Select button at Done.

6. Press the Left-Select button to confirm changes.

7. Follow the steps in the next section, Configuring the NetMask.

IP AddressSelectExit

SelectDHCPExit

Back_

Done100.000.000.000

Done

Done

_

000.000.000.000 +

+

+

+100.000.000.000

110.000.000.000

Accept RejectConfirm Changes

Configuring NIC Interfaces 27

Page 40: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance4

Configuring the NetMaskTo configure the netmask for the port configured in the previous section:

1. Press the Toggle-Forward button until the Netmask menu item appears, then press the Right-Select button to select it.

2. Press the Toggle-Forward button to move the cursor to the next field. Press the Left-Select button to change the number incrementally. Repeat this step until you have configured the netmask, then press the Right-Select button to complete the netmask configuration.

3. Press the Left-Select button to accept changes.

IP AddressSelectExit

SelectNetmaskExit

Back

Done255.100.000.000

Done255.100.000.000

Done255.110.000.000

255.000.000.000

Back255.000.000.000

+

+

+

+

+

Accept RejectConfirm Changes

Viper NT and Roadster NT User Guide28

Page 41: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance 4

4. Press the Left-Select button to exit the Netmask configuration.

5. You can configure NIC ID: E100B1 by pressing the Toggle-Forward button and by following Steps 4, 5, and 6 in Configuring a Static IP Address and then the procedure in Configuring the NetMask on page 28, or you can press the Left-Select button to complete the procedure.

6. Although you are prompted to reboot the appliance, press the Right-Select button. Configure the default gateway before you reboot. Follow the steps in the next section, Configuring an IP Address for a Default Gateway.

Configuring an IP Address for a Default GatewayTo configure an IP address for a default gateway:

1. At the Default Gateway menu item, press the Right-Select button.

SelectNetmaskExit

SetupNIC ID: E100B1Done

NoReboot?Yes

SelectDefault GatewayExit

Configuring NIC Interfaces 29

Page 42: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance4

2. Press the Left-Select button to change the number incrementally. Press the Toggle-Forward button to move the cursor to the next field. Repeat this step until you have configured the IP address, then press the Right-Select button (Done).

3. Press the Left-Select button to accept the IP address if it is correct.

4. Press the Left-Select button to reboot the system. The Default Gateway menu item appears when rebooting has completed.

Back_

Done100.000.000.000

000.000.000.000 +

+

Done100.000.000.000

Done110.000.000.000

+

+

Back

Accept RejectConfirm Changes

NoReboot?Yes

Rebooting...

SelectDefault GatewayExit

Viper NT and Roadster NT User Guide30

Page 43: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance 4

Using the Engine Configuration ScreenWith the Engine Configuration screen and a web browser, you can configure other settings, for example, the computer name, host name, domain name, and regional settings on the NT appliance.

This section includes:

• Steps to set up your web browser

• Steps to power up the NT appliance.

• Steps to complete the Engine Configuration screen

• Information about the Engine Configuration screen

▼ Setting Up Your Web BrowserThe Engine Configuration screen supports these web browsers:

• Netscape 4.x

• Internet Explorer 4.x/5.x with Java plug-in (1.2.2) installed.

If you are using a Windows 2000 system, NEI recommends that you use a Netscape browser.

Configure the browser to update the page information each time the page is browsed. Follow the steps in the next section.

NetscapeAfter opening the browser:

1. Click Edit Preferences. Go to the Advanced menu item.

2. Click + to display the Advanced pull-down menu, and click Cache.

3. Under the field, Document in cache is compared to documentation on network, select Every time and OK.

Using the Engine Configuration Screen 31

Page 44: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance4

Internet ExplorerAfter opening the browser:

1. Click View Internet Options. (version 4.x) or Tools Internet Options (version 5.x).

2. From the General tab under the Temporary Internet Files field, select Settings...

3. Under the field, Check for newer versions of stored pages, click Automatically, and click OK.

▼ Powering Up the NT ApplianceTo power up the NT appliance:

1. Log on at the Windows NT screen:

Username: administrator

Password: password

After the NT operating system loads, wait about one and a half minutes for all NEI services to start before using the Engine Configuration screen. If you receive an error message, refresh the screen and try the setup procedure again.

2. After the NT operating system loads and services start, depending on the environment, perform one of the following tasks:

• If this is an initial setup, log on at the initial screen: (entries are case-sensitive – use lowercase text)

Username: neiadmin

Password: password

A web browser is launched and the Engine Configuration screen is displayed (see Figure 17).

Viper NT and Roadster NT User Guide32

Page 45: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance 4

• If this is not an initial setup, launch your browser using one of these addresses: http://localhost:3160—for direct (local) connection

or:

http://XXX.XXX.XXX.XX:3160 —using your IP address for network connection

Then log on at the initial screen: (entries are case-sensitive – use lowercase text)

Username: neiadminPassword: password

The Engine Configuration screen appears.

3. Enter the configuration settings, select Submit, and reboot the appliance. Refer to Figure 17 and the Screen Descriptions on page 35.

If you need to re-enter configuration screen information and select Back on the browser, make sure you also Refresh/Reload the screen before changing the information and clicking Submit.

You have completed the configuration procedure. When the appliance has completely rebooted, configure the remaining appliances in your cluster.

If you need to access the configuration screen after setting the IP address, enter the new IP address following by the socket number (:3160).

▼ Engine Configuration ScreenThis section describes the button functions and selections on the Engine Configuration screen (Figure 17). You can view online help by clicking ? at the top of the configuration screen.

Using the Engine Configuration Screen 33

Page 46: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance4

Figure 17. Engine Configuration Screen

Network EnginesHomePage IIS Support

NEI TechnicalSupport

Help

10 10 10 10

255 0 0 0 255 255 255 0

192 168 30 2

neiadmin

Viper NT and Roadster NT User Guide34

Page 47: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance 4

▼ NavigationUse the arrow “<<” and “>>” buttons to scroll forward or back through existing addresses associated with that service.

Use the “+” button to add a new address. Click this button, add the address, and click Submit. If this button is not used, the address is not saved.

Use the “—” button to delete an existing address. Click this button to delete the address and click Submit.

▼ Screen DescriptionsThis section describes fields in the Engine Configuration screen.

Network Settings

Computername Enter an alphanumeric name up to 15 characters.

WINS Resolution Press Enable or Disable depending on whether you are using Window Internet Naming Services (WINS) in your network to manage the association of workstation names and their IP addresses.

Hostname Enter an alphanumeric name.

Domain Enter your domain name. If you do not have one, keep the default name.

DNS Enter the IP address of the Domain Name Server (DNS).

NIC 2 E100B1

DHCP Press the Enabled button if you want the DHCP services on AdminEngine to configure the IP address and subnet mask for NIC 2 and the default gateway.

IP Address If you disabled DHCP, enter an IP address for NIC 2.

Using the Engine Configuration Screen 35

Page 48: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance4

Subnet If you disabled DHCP, enter a subnet mask for NIC 2.

Gateway If you disabled DHCP, enter an IP address for the default gateway.

WINS If you enabled WINS Resolution, enter the IP address of the WINS server.

WINS 2 Enter the IP address of the second WINS server.

NIC 1 E100B2

DHCP Press the Enabled button if you want DHCP to configure IP address and subnet mask for NIC 1 and the default gateway.

IP Address If you disabled DHCP, enter an IP address for NIC 1.

Subnet If you disabled DHCP, enter a subnet mask for NIC 1.

Gateway If you disabled DHCP, enter an IP address for the default gateway.

WINS If you enabled WINS Resolution, enter the IP address of the WINS server.

WINS 2 Enter the IP address of the second WINS server.

Engine Configuration Access

New Password If you want to change the password to access the Engine Configuration screen, enter a new password.

Confirm Password Enter the password again for confirmation.

Automatic Service Startup

SNMP Press Enabled if you want appliance management through an SNMP-based console.

Viper NT and Roadster NT User Guide36

Page 49: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance 4

Record all configuration settings for future reference.

Configuring Internet Information Server (IIS)Once you have configured the NT appliance, you can configure IIS through the web browser.

1. Enter the appliance’s IP address in the address field in the web browser, then click on IIS (located at the top of the Engine Configuration screen).

2. Log on at the Windows NT screen:€

Username: administrator

Password: password

To enable network access to IIS on the appliance:

1. Select Start→Programs→Windows NT 4.0 Option Pack→Microsoft Internet Information Server→Internet Service Manager.

2. Select Internet Information Server from the Microsoft Management Console.

3. Select Administration Web Site, then click Properties.

4. Select Master Properties Edit.

5. Select the Directory Security tab and edit IP Address Domain Name Restrictions.

Remote Control Press Enabled if you want remote control capabilities through virtual network capabilities.

Regional Settings

Date Using the pull-down menus, enter today’s date.

Time Enter the current time.

Time Zone Using the pull-down menus, select a time zone.

Daylight Savings Enable or disable the Daylight Savings field.

Configuring Internet Information Server (IIS) 37

Page 50: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Configuring an NT Appliance4

6. Select Granted Access and click OK.

7. Record all configuration settings for future reference.

Viper NT and Roadster NT User Guide38

Page 51: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

CHAPTER 5

This chapter describes operations you can perform on an NT appliance using the LCD panel. From the panel you can:

• Shut down

• Reboot

• Redirect where to reboot

• Power off

• Reset

• Display the Unique ID

• Display MAC addresses of Ethernet ports

• Provide focus automatically (Viper NT only)

• Set the power-up mode

Although there are other menu selections available, do not use them unless directed to do so by Technical Support.

Although diagrams and procedures in this chapter show the Roadster NT, these procedures also apply to the Viper NT.

Operating an NTAppliance

Operating an NT Appliance 39

Page 52: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Operating an NT Appliance5

Shutting DownUse the shutdown procedures to shut down the NT appliance’s operating system and processes. Perform this task before you power off the appliance using the LCD panel or using the On/Off switch on the rear panel.

To shut down the NT appliance:

1. On the LCD panel, press the Left-Select button at Menu to access the menu items.

2. Press the Toggle Forward or Toggle-Back buttons until the Clean Shutdown menu item appears.

3. Press the Right-Select button to select the menu item.

4. Press the Left-Select button to confirm the shutdown. The message Shutting Down... appears.

5. When the Clean Shutdown menu item appears again, press the Left-Select button to exit the menu.

RoadsterMenu Ready

SelectNIC SetupExit

Yes NoConfirm

Shutting down...

Clean ShutdownExit Select

RoadsterMenu Ready

Viper NT and Roadster NT User Guide40

Page 53: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Operating an NT Appliance 5

RebootingReboot the NT appliance after you perform the initial configuration or when you want to shut down all services and reboot the operating system. To reboot:

1. On the LCD panel, press the Left-Select button at Menu to access the menu items.

2. Press the Toggle-Forward and Toggle-Back buttons until the Clean Reboot menu item appears.

3. Press the Right-Select button to select the menu item.

4. Press the Left-Select button to confirm the reboot. A message Rebooting... appears.

5. When the Clean Reboot menu item appears, press the Left-Select button to exit the menu. The Ready state appears after the operating system reboots. This may take several minutes.

RoadsterMenu Ready

SelectNIC SetupExit

Exit SelectClean Reboot

Yes NoConfirm

Rebooting...

Exit SelectClean Reboot

Menu FocusViper

Rebooting 41

Page 54: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Operating an NT Appliance5

Redirecting a RebootIf selected, instead of booting locally, the NT appliance looks for a PXE server the next time it boots. To redirect a reboot:

1. On the LCD panel, press the Left-Select button at Menu to access the menu items.

2. Press the Toggle-Forward and Toggle-Back buttons until the Boot Redirect menu item appears.

3. Press the Right-Select button to select the menu item.

4. Press the Toggle-Forward button to turn on boot redirect.

5. Press the Left Select button to confirm your action. The Boot Redirect menu item appears.

To activate Boot Redirect, reset or reboot the NT appliance. If you power off using the LCD panel or the On/Off switch on the rear panel, Boot Redirect does not occur.

Roadster NTMenu Ready

RoadsterMenu Ready

SelectNIC SetupExit SelectNIC SetupExit

SelectBoot RedirectExit

CancelBoot Redir=OffOk

CancelBoot Redir=OnOk

SelectBoot RedirectExit

Viper NT and Roadster NT User Guide42

Page 55: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Operating an NT Appliance 5

Powering OffWhen you power off the NT appliance, the DC power is turned off. The operating system and system services are immediately shut down if the operating system is running. To power off:

1. On the LCD panel, press the Left-Select button at Menu to access the menu items.

2. Press the Toggle-Forward and Toggle-Back buttons until the Power Off menu item appears.

3. Press the Right-Select button to select the menu item.

4. Press the Left-Select button to confirm. The Power On menu item appears.

5. Press the Left-Select button to exit the menu.

Roadster NTMenu Ready

RoadsterMenu Ready

SelectNIC SetupExit SelectNIC SetupExit

SelectNIC SetupExit SelectPower OffExit

SelectNIC SetupExit NoConfirmYes

SelectNIC SetupExit SelectPower OnExit

Powering Off 43

Page 56: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Operating an NT Appliance5

Resetting When you reset the NT appliance, it immediately stops the operating system if it is running, and initiates a reboot. To reset:

1. On the LCD panel, press the Left-Select button at Menu to access the menu items.

2. Press the Toggle-Forward or Toggle-Back buttons until the Reset menu item appears.

3. Press the Right-Select button to select the menu item.

4. Press the Left-Select button to confirm your action. The Reset menu item appears.

5. Press the Left-Select button to exit the menu.

Roadster NTMenu Ready

RoadsterMenu Ready

SelectNIC SetupExit SelectNIC SetupExit

SelectResetExit

Yes NoConfirm

SelectResetExit

Viper NT and Roadster NT User Guide44

Page 57: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Operating an NT Appliance 5

Displaying the Unique ID To display the unique ID (serial number and vendor ID) for the NT appliance:

1. On the LCD panel, press the Left-Select button at Menu to access the menu items.

2. Press the Toggle Forward button until the Show Unique ID menu item appears.

3. Press the Right-Select button to select the menu item.

4. Press the Left-Select button after you view the unique ID.

5. Press the Left-Select button to exit the menu item.

Roadster NTMenu Ready

RoadsterMenu Ready

SelectNIC SetupExit SelectNIC SetupExit

SelectShow Unique IDExit

Ok00A98AC9C3FF

SelectShow Unique IDExit

Displaying the Unique ID 45

Page 58: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Operating an NT Appliance5

Displaying MAC AddressesTo display the Media Access Control (MAC) address (a unique address) for each Ethernet port:

1. On the LCD panel, press the Left-Select button at Menu to access the menu items.

2. Press the Toggle Forward button until the Show MAC Addr menu item appears.

3. Press the Right-Select button to select the menu item.

4. Press the Right Select button to display the MAC address for NIC ID: E100B2.

5. Press the Left-Select button to exit the MAC address display.

6. Press the Left-Select button to exit the menu or press the Right-Select button at Show to display the MAC address for NIC ID: E100B1.

RoadsterMenu Ready

SelectNIC SetupExit

Exit SelectShow MAC Addr

Back ShowNIC ID:E100B1

Ok 00D0A800064C

Back ShowNIC ID:E100B2

Viper NT and Roadster NT User Guide46

Page 59: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Operating an NT Appliance 5

Providing Automatic Focus to Viper NTA Viper NT has focus when the video monitor, mouse, and keyboard connections are enabled through its CMBus. You can provide focus to Viper NT any time it is up and running by pressing the Right-Select button at Focus.

For a stand-alone appliance, you can set it to automatically have focus at start-up. This means that you set the Default Power menu item to On and the Auto Focus menu item to On.

If the Default Power menu item is set to Off and Auto Focus is set to On, the appliance will not have focus automatically. It will respond as though Auto Focus was not set to On. To give the appliance focus, manually press the Focus button.

If your Viper NT appliances are part of a cluster, do not use the automatic focus feature. In a cluster, only one appliance can have focus at a time. To provide automatic focus:

1. On the LCD panel, press the Left-Select button to access the menu items.

2. Press the Toggle Forward button until the Auto Focus menu item appears.

3. Press the Right-Select button to select the menu item.

4. Press the Toggle Forward button until the Auto Focus =On menu item appears.

ViperMenu Focus

SelectNIC SetupExit

Exit SelectAuto Focus

Auto Focus=OffCancelOk

Providing Automatic Focus to Viper NT 47

Page 60: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Operating an NT Appliance5

5. Press the Left-Select button at OK to confirm the Auto Focus = On setting. The Auto Focus menu item appears.

6. Press the Left-Select button to exit the menu item.

Setting the Power-up ModeWhen set to On, the NT appliance powers up and boots the operating system. When set to Off, it enters idle mode (LCD displays On). To set the power-up mode as On:

1. On the LCD panel, press the Left-Select button at Menu to access the menu items.

2. Press the Toggle-Forward or Toggle-Back buttons until the Default Power menu item appears.

3. Press the Right-Select button to select the menu item.

4. Press the Toggle Forward button until On appears.

CancelOkAuto Focus= On

Exit SelectAuto Focus

Roadster NTMenu Ready

RoadsterMenu Ready

SelectNIC SetupExit SelectNIC SetupExit

SelectNIC SetupExit SelectDefault Power Exit

Def Power = OffCancelOk

Viper NT and Roadster NT User Guide48

Page 61: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Operating an NT Appliance 5

5. Press the Left-Select button at OK to confirm the On setting. The Default Power menu item appears.

6. Press the Left-Select button to exit the menu item.

CancelOkDef Power = On

Exit SelectDefault Power

Setting the Power-up Mode 49

Page 62: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Operating an NT Appliance5

Viper NT and Roadster NT User Guide50

Page 63: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

CHAPTER 6

This chapter describes how to power off, remove, and replace an NT appliance. The procedures are the same for Viper NT and Roadster NT.

Replacing a Standalone NT ApplianceTo remove and replace a standalone NT appliance:

1. Record all network settings before starting these procedures.

2. Perform a Clean Shutdown from the LCD panel. Refer to Chapter 5, Operating an NT Appliance for information on shutdown procedures.

3. Disconnect the power cord and Ethernet cables from the appliance.

4. Install the new appliance using the procedures in Chapter 2, Installing an NT Appliance.

5. Configure the new appliance using the procedures in Chapter 4, Configuring an NT Appliance.

Replacing a Clustered NT ApplianceTo remove and replace an NT appliance in a cluster:

1. Perform a Clean Shutdown from the LCD panel. Refer to Chapter 5, Operating an NT Appliance for information on shutdown procedures.

2. Disconnect the power cord and Ethernet cables from the appliance.

Removing and Replacing anNT Appliance

Removing and Replacing an NT Appliance 51

Page 64: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Removing and Replacing an NT Appliance6

CAUTION!

Disconnect the CMBus cables from the NT appliance you are removing.

3. Disconnect the CMBus cables from the appliance you are removing but do not disconnect the cables from the adjacent appliances – connect the loose ends of the CMBus cables to the adjacent appliances as shown in Figure 18.

4. Carefully remove the disconnected appliance from the cluster. Figure 18 shows the removal of a Roadster NT appliance from a cluster.

Figure 18. Removing an NT Appliance from the Cluster

5. Install and cable the new appliance in the cluster using the procedures in Chapter 2, Installing an NT Appliance and in Chapter 3 Cabling an NT Appliance.

10

1

0

1

0

1

0

Viper NT and Roadster NT User Guide52

Page 65: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Removing and Replacing an NT Appliance 6

6. Reconnect the power cord, Ethernet cables, and CMBus cables using the procedures in Chapter 3, Cabling an NT Appliance. Reconnect the CMBus cables in the original configuration.

7. Power on (AC) and configure the appliance using the procedures in Chapter 4, Configuring an NT Appliance.

Replacing a Clustered NT Appliance 53

Page 66: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Removing and Replacing an NT Appliance6

Viper NT and Roadster NT User Guide54

Page 67: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

APPENDIX A

This appendix lists the following specifications for the NT appliances with separate descriptions for the Viper NT and Roadster NT.

• Hardware and software

• Physical

• Operational

Table 6 lists the hardware and software specifications for Viper NT.

Specifications

Table 6. Hardware and Software Specifications for Viper NT

Component Description

Processor One or two Intel Pentium III

Processor Internal Clock(subject to current capabilities of specific models)

400 through 1000 MHz

Memory • 4 DIMM sockets• 64 - 512MB DIMM; up to 2048 MB total

on board

Disk IDE or SCSI

IDE Bus Primary and secondary IDE; both connectors present on board, internal only.

PCI Bus • 2 PCI Connectors• 1 Mezzanine Connector• 32 bit/ 33MHz

Ethernet 2 10/100 Mbps RJ45

Specifications 55

Page 68: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

SpecificationsA

Table 7 lists the physical specifications for Viper NT.

Depending on the environment, the following temperature and humidity calculations may vary.

USB Dual USB connectors

Serial Ports 2 serial ports; COM1, COM2

SCSI PCI board option only

CM Bus Standard NEI Cluster Management Bus (CMBus)

SMBus Standard System Maintenance Bus (SMBus)

Power Supply 100-240VAC, 50-60 HzIEC 320 connector, switched from rear panel

Case 1U, 19” RETMA rack mountable, internally cooled by air flow

Operating System NT4

PC Compliance Microsoft HCT; HCT cases as appropriate for system configuration

Table 7. Physical Specifications for Viper NT

SpecificationLower Limit

Upper Limit Unit

Operating Temperature 5 35 Degrees Celsius

Non-Operating Temperature

-20 80 Degrees Celsius

Rate-of-change of temperature, operating

5 Degrees Celsius per minute

Operating humidity, non-condensing

10 90 %

Table 6. Hardware and Software Specifications for Viper NT (continued)

Component Description

Viper NT and Roadster NT User Guide56

Page 69: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

ASpecifications

Non-operating humidity,Non-condensing

5 95 %

Operating shock 5 G half sine, 2 mS

Non-operating shock 50 G half sine, 2 mS

Operating vibration 1 G, 5-500 Hz

Non-operating vibration 2 G, 5-500 Hz

Operating altitude • 10,000• 3,000

• Feet ASL• Meters ASL

Non-operating altitude • 40,000• 12,000

• Feet ASL• Meters ASL

AC line voltage(subject to current capabilities of specific models)

100 240 Volts AC, 50-60 Hz

Power • 150• 90

• Watts maximum• Watts typical

Line currentActual line current depends on actual line voltage, applications software, and product configuration

• 1.14• 1.40• 0.57• 0.70

• Amps, 120V line• Amps, 100V line• Amps, 240V line• Amps, 200V line

Heat 515310

• BTU/hr maximum• BTU/hr typical

Acoustic noiseMeasured in a free field over a hard floor, 1 meter from equipment face and 1 meter above floor

60 DBA

Weight 25 Lb

Table 7. Physical Specifications for Viper NT (continued)

Specifications 57

Page 70: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

SpecificationsA

Table 8 shows the AC current, real power, heat load, and number of branch circuits required for different numbers of Viper NT appliances. Actual numbers may vary depending on options and operating conditions, but these numbers represent fully-loaded systems running test software.

The rationale for the numbers is that a typical server draws approximately 1.14 Amperes from a nominal 120 Volt, 60 Hz line. A branch circuit with a 20-ampere breaker can be loaded with 15 amperes rated load. No limit is assumed on the amount of current that can be supplied to a single rack of servers; multiple independently protected branch circuits may be used when the capacity of a single branch circuit is not enough.

For units powered from 240 Volt AC mains, current will be half of the 120 Volt value shown.

Table 8. Operational Specifications for Viper NT

UnitsAC Current(Amperes)

Power(Watts)

Heat(BTU/hr) # 20A Circuits

5 5.70 450 1413 1

10 11.40 900 2826 1

15 17.10 1350 4239 2

20 22.80 1800 5652 2

25 28.50 2250 7065 2

30 34.20 2700 8478 3

35 39.90 3150 9891 3

40 45.60 3600 11304 4

42 47.88 3780 11869 4

Viper NT and Roadster NT User Guide58

Page 71: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

ASpecifications

Table 9 shows the hardware and software specifications for Roadster NT.

Table 9. Hardware and Software Specifications for Roadster NT

Component Description

Processor Intel Celeron

Processor Internal Clock 466 MHz or 533 MHz depending on model

Memory • 2 DIMM sockets• 64 - 256MB DIMM; up to 512 MB total onboard

IDE Bus • Primary and Secondary IDE• Both connectors present onboard, internal only.

PCI Bus • 1 PCI connector• 1 Mezzanine connector• 32 bit/ 33MHz

Ethernet 2 10/100 Mbps RJ45

USB Dual Universal Serial Bus (USB) connectors

Serial Ports 2 serial ports; COM1, COM2

SCSI • Ultra-2 SCSI • Internal connector plus external connector• External connector, ultra-high-density 68-pin.

CMBus Standard NEI CMBus

SMBus Standard System Maintenance Bus (SMBus)

Power Supply • 90-250VAC, 50-60 Hz• IEC 320 connector, switched from rear panel

Case 1U, 19” RETMA rack mountable, internally cooled by air flow

Specifications 59

Page 72: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

SpecificationsA

Table 10 shows the physical specifications for Roadster NT.

Depending on the environment, the following temperature and humidity calculations may vary.

Operating System NT4

Voltage Monitoring All power voltages +5, +3.3, +12, -12, VCCVID

Temperature Monitoring(depending on the environment, calculations may vary)

• Case internal temperature maximum ambient plus 10 degrees C, CPU maximum ambient plus 35 degrees C

Table 10. Physical Specifications for Roadster NT

SpecificationLower Limit

Upper Limit Unit

Operating Temperature 5 35 Degrees Celsius

Non-Operating Temperature

-20 80 Degrees Celsius

Rate-of-change of Temperature, operating

5 Degrees Celsius per minute

Operating Humidity, non-condensing

10 90 %

Non-operating Humidity,Non-condensing

5 95 %

Operating Shock 5 G half sine, 2 mS

Non-operating Shock 50 G half sine, 2 mS

Operating Vibration 1 G, 5-500 Hz

Non-operating Vibration 2 G, 5-500 Hz

Table 9. Hardware and Software Specifications for Roadster NT

Viper NT and Roadster NT User Guide60

Page 73: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

ASpecifications

Operating Altitude 10,0003,000

Feet ASLMeters ASL

Non-operating Altitude 40,00012,000

Feet ASLMeters ASL

AC Line Voltage(subject to current capabilities of specific models)

100 240 Volts AC, 50-60 Hz

Power 120 45

Watts maximumWatts typical

Line CurrentActual line current depends on line voltage, configuration, and activity

0.750.910.380.45

Amps, 120V lineAmps, 100V lineAmps, 240V lineAmps, 200V line

Heat 548154

BTU/hr MaximumBTU/hr typical

Acoustic NoiseMeasured 1 meter from front panel, 1 meter above hard floor, otherwise a free field

50 DBA

Weight 20 lb

Table 10. Physical Specifications for Roadster NT (continued)

Specifications 61

Page 74: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

SpecificationsA

Table 11 shows the AC current, real power, heat load, and number of branch circuits required for different numbers of Roadster NT appliances.

Table 11. Operational Specifications for Roadster NT

UnitsAC Current(Amperes)

Power(Watts)

Heat(BTU/hr) # 20A Circuits

5 2.05 225 707 1

10 4.10 450 1413 1

15 6.15 675 2120 1

20 8.20 900 2826 1

25 10.25 1125 3533 1

30 12.30 1350 4239 1

35 14.35 1575 4946 1

40 16.40 1800 5652 2

42 17.22 1890 5935 2

Viper NT and Roadster NT User Guide62

Page 75: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

Index

Numerics19-inch rack

installing appliances 14

Aaddress

MAC 46appliances

description 1features 2logging on 32, 33replacing 51

Auto Focus 4, 7, 39, 47menu selection 7

BBoot Redirect

menu selection 8browser

interface to Web 3buttons on front panel 6

Ccable

CMBus 52connecting CMBus 18Ethernet 17

for mixed cluster 20power connection 17

Clean Rebootmenu selection 8

Clean Shutdownmenu selection 8

Clear Temp LEDmenu selection 8

clustered appliancesmixed appliances 20replacing 51Roadster NT 20Viper NT 19

CMBus 3cable connection 18cables 52connectors 10

configurationdefault 24Engine Configuration screen 33IIS 37

connectionCMBus cable 18Console Cable Adapter 18power cable 17

connector 10

63Viper NT and Roadster NT User Guide

Page 76: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

connectorsrear panel 9

DDate and Time

configuration 37regional settings 37

Default CMB Addrmenu selection 9

Default Gateway 29configuration 29menu selection 7

Default IP addresses 24Default Power

menu selection 7desktop

installing appliances 12DHCP 25, 35

configuration 35Disable Temp LED

menu selection 9DNS configuration 35domain name 35

configuration 35

EEngine Configuration screen 31,

33changing access 36

Ethernet ports 23, 24configuration 24

Ffeatures of appliances 2focus 4, 7, 39, 47front panel

buttons 6

LEDs 5

GGateway settings 36

HHDD

front panel LEDs 5Hostname 35

in setup screen 35

IIDE disk 3IIS configuration 37installation cabling

mixed cluster 20Roadster NT 20Viper NT 19

installing appliances19-inch rack 14booting sequence 8desktop 12Telco rack 13

Internet Information Service 37IP address

static configuration 35

Kkeyboard and mouse

connections 18

LLAN1 and LAN2

front panel LEDs 5LCD panel 6, 24LEDs on front panel 5logging on

Viper NT and Roadster NT User Guide64

Page 77: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

IIS 37NT 32to NT appliance 32, 33

MMAC address 46

Nnetworks 17

Ethernet 17external 17

NIC interface 24NIC Setup

menu selection 7

Ppassword changes

Engine Configuration screen 36

Powercables 17front panel LEDs 5off 43

Power On/Offmenu selection 7

processors 2PXE 42

Rrear panel 9rebooting 41

redirecting reboot 42regional settings

configuration 37replacing appliances 51Reset

menu selection 8

resetting appliances 44Roadster NT

cluster and cabling 20

Sscreen

Engine Configuration 31, 33SCSI disk 3serial ports 10settings

default power-up mode 48regional 37

setup for configuration 31Show Alert ID

menu selection 9Show CMB Addr

menu selection 8Show MAC Address

menu selection 8Show Unique ID

menu selection 8SNMP management 36

configuration 36standalone appliance

replacement 51static IP addressing 26, 35subnet mask 24, 28, 36

configuration 28, 36

TTelco rack

installing appliances 13Temperature

front panel LEDs 5

Uunique ID 45

Viper NT and Roadster NT User Guide 65

Page 78: WebEngine Viper NT WebEngine Roadster USER …effeng.com/nei/manuals/vipernt/ViperRoadsterNT1.5.pdf25 Dan Road, Canton, MA 02021-2817 (781) 332-1900 Fax: (781) 770-2000 WebEngine Viper

USB connectors 10

VViper NT

automatic focus 47cluster and cabling 19

WWatchDog

front panel LEDs 5Web browser 3

requirementsfor Netscape 31Internet Explorer 32

WINS server and configuration 36

Viper NT and Roadster NT User Guide66